WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Similar documents
WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

Express Lavatory System SS-Series

LVQD1 Verge with WashBar Technology LVQ-Series

Express Lavatory System MG-Series

Express Lavatory System MG-Series

SS-1N Express Lavatory System SS-Series

SS-3N Express Lavatory System SS-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

SS-2N Express Lavatory System SS-Series

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

Installation Instructions

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

FL-1H, FL-1L Frequency Lavatory System FL-Series

Installation Instructions

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation Instructions

Installation Instructions

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

Installation Instructions

FL-3H, FL-3L Frequency Lavatory System FL-Series

AV60 Advocate Lavatory System AV-Series

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

AV30 Advocate Lavatory System AV-Series

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation Instructions

Washfountain Application Guide

1a Installing Optional Soap Dispenser for A/O Drain Units. A Place the upper tie bar on top of the. B Insert the tie rod assembly through the

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

AV60 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

FL-2H, FL-2L Frequency Lavatory System FL-Series

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

AV90 Advocate Lavatory System AV-Series

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

A. Section Joint Sealants: Seal fixtures to walls and floors.

Durability within reach

Willoughby Industries - Security Products

DUKE UNIVERSITY CONSTRUCTION STANDARDS

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

FAUCET PARTS - EXPLODED VIEW Model: K-59

School Solutions Ideabook

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Installation Instructions

SECTION PLUMBING

Front Load Washer FAFW3801L W

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

Refrigerated Air Dryer

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation Instructions OBSOLETE

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

7000BT Eye/Face Washes

Installation & Operation

Installation & Operation Manual

C O D E S & A M M E N D M E N T S

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

PAT BASIN MODEL 9121, 9131, & 9141

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

CL64T INDUSTRIAL TOTE WASHER

HL45, HL80 Thermostatic High-Low Valves

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

LA45 DISCONTINUED IMPORTANT!

Packaged Steam Fired Water Heater

Willoughby Industries - Security Products

Transcription:

cupertified Pre-ssembled owl and Pedestal vailable in 5 or 36" Diameter Semi-ircular or ircular owls 9" Deep owl, Designed for Heavy Duty Hand Washing Foot, ir Metering, Infrared or TouchTime ontrol Specifications Size and apacity Semi-circular models accommodate up to 3 users (36" models) or 4 users (5 models) at a time. ircular models accommodate up to 5 users (36" models) or 8 users (5 models) at a time. ll models utilize less water, energy and space than lavatories equipped with conventional faucets. The washfountain bowls, pedestals and valve sets are completely assembled. Only the support column and connections to the valve set and drain require assembly. The operating range is 20-80 PSI. Flow rate controlled by volume control valve. pproximate flow-rates for each model: 36" semi-circular: 1.25 GPM 5 semi-circular: 3 GPM 36" circular: 2 GPM 5 circular: 5 GPM onstruction radstone : n extremely durable plastic material made of reinforced thermosetting polyester resins, finely ground inorganic fillers and fade resistant pigments. Pedestals: onstructed of die-formed legs, upper braces, scuff bases and panels: legs are zinc chromate plated 14 gauge steel; upper braces are 16 gauge galvanized steel; and scuff bases are 300 series stainless steel with a #4 finish. radstone models have tapered, vacuum-formed plastic access panels. Standard Equipment Valves and Fittings In addition to the bowl and pedestal assembly, the following valves and fittings are standard: sprayhead with stainless steel support tube and bowl gasket; spud with domed strainer; sprayhead supply line; manual mixing valve; volume control valve; and (2) stop, strainer and check valves. ctivation ontrols Foot ontrol Each press of the foot rail mechanically actuates a hold-open valve, with slow closing upon release of foot pressure. ir Valve Hand ontrol Each push button pneumatically actuates a non-hold-open, air metering, single-temperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates a flow of tempered water from the non-sectional sprayhead. Push button requires less than five pounds of pressure. WF2804 Electronic Infrared ontrol Hands placed within the bowl are detected by an infrared sensor module which activates a flow of tempered water from the non-sectional sprayhead. Shut-off is automatic after hands are removed from the detection area. The infrared sensor uses a conical-shaped transmitting beam, having a detection area adapted to, but not exceeding, the bowl perimeter. The adaptive infrared sensor automatically adapts to the bowl after power is turned on. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low-voltage transformer as standard equipment: Solenoid 24V, 50/60 Hz, 3/ NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Transformer lass II UL/S listed, 110/24 V plug-in transformer. Plugs into a standard GFI protected electrical outlet. of transformer per local electrical code. TouchTime Hand ontrol Each low-voltage button actuates a non-hold-open, slow-closing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each push button activates a flow of tempered water from the non-sectional sprayhead. TouchTime controls water flow at each station through the use of solid state, digital circuitry. Timing is electronically controlled at 15 seconds. Push button requires less than five pounds of pressure. ode ompliance and ertifications cup pproval Pre-ssembled lassic Washfountains are Uniform Plumbing ode (UP), International Plumbing ode (IP) and National Plumbing ode of anada (NP) approved through the International ssociation of Plumbing and Mechanical Officials (IPMO). Manufactured in compliance with IG 156-2009, S 45 Series-2002 (R08) & SME 112.18.1-2005/ S 125.1-2005. Standard product selections contained within this document are third party ERTIFIED to NSF/NSI 372 meeting the Lead-Free content requirement. ny product configured with custom options will be OMPLINT with NSF/NSI 372 meeting the Lead-Free content requirement. Page 1 of 7 ertified to NSF/NSI 372

Models (Must select one) Model Size Users Material WF2803 36" Semi-ircular 3 radstone WF2804 WF2805 WF2808 5 Semi-ircular 36" ircular 5 ircular 4 5 8 radstone radstone radstone Standard Selections (Must select one from each category) Drain Type (select one) Off-line vent with supplies from below H O entrally rising vent with supplies from above entrally rising vent with supplies from below Off-line vent with supplies from above Pedestal Height (select one) STD Standard Height ontrols (select one) F Foot ontrol Valve IR Infrared ctivation Mixing Valve (select one) MMV Manual Mixing Valve Soap Dispenser (select one) PSD Powdered Soap Dispenser LSD Liquid Soap Dispenser radstone owl olor (select one) SOX Sandbox ON arbon TT ST NSD TouchTime Metering ir Valve Metering No Soap Dispenser Optional Selections Thermostatic Mixing Valve TM Thermostatic Mixing Valve (in lieu of manual mixing valve) Metal Soap Dispenser MLSD Metal-lad Liquid Soap Dispenser MPSD Metal-lad Powdered Soap Dispenser 1-1/2" Tie Pipe ssembly T Shroud SH Reinforces Support Tube Stainless Steel Shroud (onceals Overhead Piping) Paper Towel Dispensers TD (2) -Fold, Multi-Fold Dispenser SFTD (2) Single-Fold Dispenser *Non-cancelable, not-returnable Semi-ircular radstone WF2803 and WF2804, ircular radstone WF2805 and WF2808 WF2803 WF2804 WF2805 WF2808 Page 2 of 7

Dimensional Infromation H G D **dd 3-1/2" to Dimensions & D for Optional TouchTime (TT), Infrared Sensor (IR) or ir Valve (ST) E Semi-ircular F Model Size ** D** E F G H 2804 29-1/ (743) 37-1/2" (953) 46" (1168) 54-3/8" (1381) 35-1/ (895) 24-1/ (616) 35-1/ (895) 8-1/ (222) 2803 29-1/ (743) 3 (864) 42-1/2" (1080) 50- (1292) 35-1/ (895) 18-1/ (464) 25-3/ (654) 7-3/ (197) E D **dd 3-1/2" to Dimensions D & E for Optional TouchTime (TT), Infrared Sensor (IR) or ir Wave (ST) F ircular Model Size ** D** E F 2808 29-1/ (743) 37-1/2" (953) 46" (1168) 54-3/8" (1381) 54 (1372) 32 (813) 2805 29-1/ (743) 3 (864) 42-1/2" (1080) 50- (1292) 36 (914) 21 (533) ** dd 3-1/2" (89) for optional TouchTime (TT), infrared sensor (IR) or air valve (ST). Page 3 of 7

Rough-In Notes 1. ll pipes and fittings not furnished by radley are shown in broken lines. 2. Supply lines for one to two washfountains should be 1"; for three washfountains 1-1/; for more than three washfountains, pipe sizes should be increased proportionately. 3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube. 4. heck valve inlets are 1/2" NPT. 5. Drain Types and H: For maximum rigidity of sprayhead/support tube assembly, use 1-1/2" NPT galvanized pipe for vent. Use of plastic or copper for vent is not recommended. Rough-Ins Semi-ircular Type 2" NPT Drain Through Floor (Stub Up 3" (76) bove Floor) Type O 1" NPT Supplies Through Wall 2" NPT Drain Through Wall (Stub Out to Suit Trap Dimension) Trap * old 3-1/ (83) See elow Washfountain owl 1" NPT Supplies Through Floor (Optional) Stub Up 2-1/2" (64) bove Floor enter Line of Drain to enter Line of Fixture Washfountain owl 1" NPT Supplies from bove Must Reduce to 1/2" Nom. opper Tube on These enters to Pass Thru Washfountain 2" NPT Drain Through Wall (Stub Out to Suit Trap Dimension) See elow * Trap (22) (22) 1-1/ (32) old 2" NPT Drain Through Floor (Stub Up 3" (76) bove Floor) Washfountain owl Washfountain owl enter Line of Drain to enter Line of Fixture Drain Through Wall Wall Trap for Wall Outlet Only Drain Through Wall Trap for Wall Outlet Only learance Hole learance Hole ** 12" (305) for Standard Height ** Wall Supplies Through Wall Floor Drain and Supplies Through Floor Trap Located elow Floor (Optional) Floor Drain and Supplies Through Floor Trap Located elow Floor (Optional) Installing Traps When installing trap with a coupling and nipple, see dimension D in the chart below. If trap is installed tight to bottom of bowl, dimension D depends on design of trap. Model owl Size * ** (Standard Height) WF2804 8-1/ (210) 6 to 11-5/8" (152 to 295) WF2803 7-3/ (197) 6 to 12" (152 to 305) * Wall to centerline of trap ** enterline of drain to floor Page 4 of 7

Rough-Ins Semi-ircular (continued) Type entrally rising vent with Type H entrally rising vent with old 1" NPT Supplies from bove Must Reduce to 1/2" Nom. opper Tube on These enters to Pass Thru Washfountain 1-1/2" NPT Vent to eiling (22) Washfountain owl 1" NPT Supplies Through Wall 1-1/2" NPT Vent to eiling old Washfountain owl Washfountain owl (22) 7-3/ (197) for radstone owl 8-1/ (210) for radstone owl 1-1/ (32) 2" NPT Drain Through Floor (Stub Up 3" (76) bove Floor) Washfountain owl 3-1/ (83) 7-3/ (197) for radstone owl 8-1/ (210) for radstone owl 2" NPT Drain Through Floor (Stub Up 3" (76) bove Floor) 1" NPT Supplies Through Floor (Optional) Stub Up 2-1/2" (63) bove Floor Wall Vent Vent 12" (305) for Standard Height Floor Drain Through Floor Supplies Through Floor (Optional) Drain Through Floor Dimensions Pedestal nchoring Model owl Size Standard Height WF2504 16-1/2" (419) 1 (356) 18-1/ (464) WF2503 11" (279) 8-5/8" (219) 18-1/ (464) nchoring Pedestals 1. Place pedestal assembly as shown. 2. nchor pedestal assembly to floor and wall with suitable wall fasteners. acking may be required in some types of wall construction. Page 5 of 7

Rough-Ins Semi-ircular (continued) Types and O Types and H Fixture enterline Fixture enterline Vented Trap 111-024 * D 11"* (279) Drain Through Floor (Optional) * Suggested location of 110V GFI electrical outlet. lways check local codes before installing. Outlet may be required to be in a remote location. Model owl Size (ll Types) (Types & O) (Types & H) D (Types & H) WF2804 8-1/ (210) 6 to 11-5/8" (152 to 295) 17" (432) 7" (178) WF2803 4-3/ (121) 6 to 13-1/ (152 to 337) 18-5/8" (473) 7" (178) Page 6 of 7

Rough-Ins ircular Type Type entrally rising vent with Stub Up 2-1/2" (64) bove Floor Must Reduce to 1/2 Nom. opper Tube on These enters to Pass Through Washfountain old 2-1/2" (64) 5"* (127) onduit old 1-1/ (32) 5"* (127) onduit 2" NPT Drain: Stub Up 3" (76) bove Floor 2" NPT Drain: Stub Up 3" (76) bove Floor 1-1/2" NPT Vent to eiling owl owl owl owl Type H entrally rising vent with Stub Up 2-1/2" (64) bove Floor Type O Must Reduce to 1/2 Nom. opper Tube on These enters to Pass Through Washfountain 2" NPT Drain: Stub Up 3" (76) bove Floor old 2-1/2" (64) 1-1/ (32) old 5"* (127) onduit 1-1/2" NPT Vent to eiling 5"* (127) onduit 2" NPT Drain: Stub Up 3" (76) bove Floor owl owl owl owl * Remote mounting of transformer with 24 V electrical supply to washfountain is recommended. See local electrical codes before roughing in. (This conduit location is only a recommendation.) Page 7 of 7