Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Similar documents
Operation and Maintenance Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Excel-EN Conventional Fire Control Panel

Installation, Operating and Maintenance Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual

Intelligent Security & Fire Ltd

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

SOLO Single Loop Addressable Fire Control Panel

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

An introduction to... Sigma

Conventional Fire Control Panel

user manual Document No , Revision 03 November 2015

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

Application, Installation, Operation & Maintenance Manual

ZSC100 Gas Detection and Alarm System Controller

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

ORION Mini-Rep INSTALLATION MANUAL

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

5000 INSTALLATION GUIDE

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Installation and user manual for the BiWire / Conventional Repeater Panel

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

USER MANUAL & MAINTENANCE GUIDE OG OO

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Conventional Fire Alarm System 2014 V1.2

User Operation Manual

Control Panel Engineering and Commissioning Instructions

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

SYSTEM 5000 USER MANUAL

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

The EN54 Part 2 & 4 Fire System

Document No Issue 4 user manual

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

PREMIER EVACS 1-16 INSTRUCTION MANUAL: 2-ZONE NETWORKED VOICE ALARM PANEL INSTALLATION MANUAL

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Flostop TS D7E and A8E. Operation Manual

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Flopurge TS. Operation Manual

Product Data Sheet. Remote Terminals. Features:

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

The EN54 Part 2, 4 and 13 Fire System

Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

System 800 Addressable Fire Detection & Alarm System

OPERATION AND INSTALLATION MANUAL

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

FIRE ALARM CONTROL PANEL FVC01-08

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Components Brochure DX CONNEXION

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Intelligent Security & Fire Ltd

Control Panel User Guide (TO BE RETAINED BY THE USER)

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Conventional Fire Control Panel with Extinguishant Control Unit. Operation and Maintenance Manual SIGMA-2-M3-ECU SIGMA-4-M3-ECU SIGMA-8-M3-ECU

Intelligent Security & Fire Ltd

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Loadstar AC/DC Systems

EXTINGUISHING AGENT RELEASE MODULE

Interface Modules for SENTRI

Conventional & Twin-wire Fire System

Precept Marine Control Panel Application Guide

ZXSe Range Data Sheet

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

FireNET Plus Wiring Instructions

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

MR-2602 Two Zone Fire Alarm Control Panel

Digital Electronic Thermostat With RF

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Fire Alarm Control Panel. System Maintenance and Log Book

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

Installation, Commissioning & Operating Manual

Transcription:

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Australia Issue 01 April 2012

Contents 1 Introduction 3 2 Safety 3 3 Installation 4 3.1 Mounting the Cabinet 4 4 Specifications 5 5 Common indications and controls 5 6 Connections 6 7 Addressing 7 8 Power requirements 8 9 Configuration 9 10 Changing or adding LED positions 13 11 Maintenance and testing 14 Syncro AS Matrix.docx Page 2 of 16

1 Introduction Syncro Matrix mimic panels provide a flexible and expandable solution for geographical fire alarm system mimic panels via a simple two wire data link connected to Syncro (with firmware version 5.90 or above) or Syncro AS (with firmware version V5.22 or above) fire alarm control panels. Mimic panels require Loop Explorer version 4.9 or above for configuration. The modular nature of Syncro Matrix Mimic panels, allows mimics with up to 500 indicators to be realised very simply and with the ability to add, remove or change the position of indicators with no wiring necessary by a unique method of flexible light pipes. 2 Safety Suppliers of articles for use at work are required to ensure as reasonably as is practical that the article will be safe and without risk to health when properly used. An article is not regarded as properly used if it is used without regard to any relevant information or advice relating to its use made available by the supplier. This product should be installed, commissioned and maintained by trained service personnel in accordance with the following: (i) (ii) (iii) (iv) Local regulations for electrical equipment in buildings Codes of practice Statutory requirements Any instructions specifically advised by the manufacturer As an installer you are requested to take such steps as are necessary to ensure that you make any appropriate information about this product available to anyone concerned with its use This equipment is designed to operate from 230V 50Hz mains supplies and is of class 1 construction. As such it must be connected to a protective earthing conductor in the fixed wiring of the installation. A readily accessible double pole disconnect device with a disconnect air gap of at least 3mm and conforming to AS3000, shall be incorporated in the fixed wiring. Failure to ensure that all conductive accessible parts of this equipment are adequately bonded to the protective earth will render the equipment unsafe. This equipment is designed for indoor use only and at temperatures between -5C (+/- 3) and +40C (+/- 2) and with a maximum relative humidity of 95%. The IP rating for the enclosure is IP30. Operation outside of these limits may render the equipment unsafe. Syncro AS Matrix.docx Page 3 of 16

3 Installation Installation of the panel should be carried out by qualified personnel only. The electronic components within the mimic panel are vulnerable to physical damage and damage by electrostatic discharges. Hence, it is advisable to wear a wrist strap designed to prevent the build-up of static charges within the body, before handling any electronic circuit boards. Never insert or remove boards or components with the power on. 3.1 Mounting the Cabinet The site chosen for the location of the panel should be clean and dry and not subject to shock or vibration. The temperature should be in the range -5 to +40 C, the humidity should not exceed 95%. Syncro AS Matrix.docx Page 4 of 16

4 Specifications The information in the table below is for the standard range of Syncro Matrix Mimics with up to 56 LEDs in the standard 385mm X 520mm enclosure. Some details are common to all models of Syncro Matrix Mimics. Mains supply (230V Versions only) 230V AC +10% - 15% (100 Watts maximum) Mains supply fuse (230 V Versions only) T2A L250V Replace only with similar type Power supply rating (230 V Versions only) 4 Amps total including battery charge 28V +/ 2V Maximum ripple current (230 V Versions only) 200 millivolts Battery type (Yuasa NP) (230 V Versions only) Two 12 Volt sealed lead acid (7Ah maximum) Battery charge voltage (230 V Versions only) 27.6VDC nominal (temperature compensated) Battery charge current (230 V Versions only) 1.5A maximum Maximum current draw from batteries (230 V 3 Amps. With mains power source disconnected Versions only) Quiescent current See section 8 Supply voltage (24V versions) 21 to 30V DC Supply current See section 7 Terminal capacity 0.5mm2 to 2.5mm2 solid or stranded wire Enclosure Size 385W X 520H X 110D Mimic area 303W X 340H Construction 1.2mm mild steel epoxy powder coated BS 00A 05 midgrey fine texture (Mimic 3mm Perspex ) Controls (if fitted) Enable controls, Lamp Test, Buzzer Silence, Reset, Silence alarm Common indicators (if fitted) Fire (red), Power On (green), Fault (yellow), Disablement (yellow) Enable keyswitch Standard 901 key Cabinet locks Two, standard 801 key Communications interface RS485 Syncro/Syncro AS serial I/O bus protocol Number of indicators (standard models) up to 8, up to 24, up to 40 or up to 56 5 Common indications and controls Versions of Syncro Matrix Mimic panels are available with or without common indications and controls. Versions with common indicators have the following standard indicators: FIRE Lights whenever a fire condition is present on the panel to which the mimic panel is connected POWER ON Indicates that the mimic panel is supplied with power FAULT- Lights whenever a fault condition is present on the panel to which the mimic panel is connected DISABLEMENT - Lights whenever a disablement condition is present on the panel to which the mimic panel is connected Versions with controls have the following switches: ENABLE CONTROLS Keyswitch which enables the RESET and ALARM SILENCE controls LAMP TEST Illuminates all indicators when pressed for testing purposes BUZZER SILENCE Silence the mimic s internal buzzer RESET Resets the Syncro control panel to which the mimic panel is connected ALARM SILENCE Silences the sounders on the Syncro control panel to which the mimic panel is connected. Syncro AS Matrix.docx Page 5 of 16

6 Connections Syncro Matrix Mimics without a built in mains power supply and battery charger, require a four wire connection. Two wires are needed for 24V DC power which should be from a suitably rated source (see section 8) and two wires are required to connect to the COMMS terminals at the Syncro fire alarm control panel. Syncro Matrix mimic panels with a built in power supply require a 230V mains supply and a two wire data connection to the Syncro fire alarm control panel. The mains and data cables should be segregated by a distance of at least 50mm. Data cable connection Mains connection (if required) Syncro AS Matrix.docx Page 6 of 16

RS485 transmission lines need to be terminated for correct operation. All boards that connect to the Syncro serial bus have a jumper link which needs to be fitted to the last board on the RS485 transmission line only. If the Matrix Mimic panel is the last device on the Syncro serial bus, then the jumper link should be fitted as shown on the drawing below. Only one board (the last one connected to the serial bus) should be fitted with a jumper link. If there are additional Syncro I/O boards or View repeaters fitted further down the RS485 transmission line then no links should be fitted to the mimic boards and a link should be fitted to the last I/O board. See I/O board manuals for further information on this. 7 Addressing Each of the LED driver boards in the Syncro Matrix Mimic must be allocated a unique address number between 1 and 32. These addresses must be different to any other boards or Syncro View repeater panels connected to the Syncro panel RS485 transmission line. The address is set by a binary coded DIL switch on each board. This example shows addresses 1 to 4 set on a 56 way Mimic panel. Syncro AS Matrix.docx Page 7 of 16

All 32 possible addresses are shown below. 8 Power requirements Versions of the Syncro Matrix Mimic without a power supply and battery back-up facility, need 24V DC power from a suitable, AS7240-4 approved battery backed power source. This must be sufficiently rated to provide power for the maximum number of LEDs and with batteries of a suitable size to provide power for the standby period required. The table below shows the power required in standby and full alarm condition for the range of Syncro Matrix Mimics with up to 56 indicators. NUMBER OF LEDs STANDBY CURRENT FULL ALARM CURRENT BATTERIES FOR 24 HOURS BATTERIES FOR 48 HOURS 24 0.026 0.09 0.88Ah 1.76Ah 56 0.052 0.18 1.75Ah 3.5Ah 88 0.078 0.36 2.8Ah 5.2Ah The battery size in Ampere hours is calculated as follows: (Standby period in hours x 1.25) x (Standby current + ((Full Alarm current/2) x 1.75) Versions of the Syncro Matrix Mimic that have an integral power supply require 230V AC mains power. Standby battery capacity is calculated as above. The power supply fitted to standard Syncro Matrix Mimic panels is approved to AS7240-4 model rated at 3 Amps. Syncro AS Matrix.docx Page 8 of 16

9 Configuration Mimic panels are configured using the Loop Explorer configuration programme (version 4.9 or above). All mimic panels consist of an 8 way LED board (which also contains the common LEDs and pushbuttons if fitted). If the mimic has more than 8 ways, additional 16 way LED boards up to a maximum total number of 32 boards may be fitted. To add the 8 way mimic LED board to a Loop Explorer configuration file, highlight the control panel icon on the left and then double click on the 8 way board icon as shown highlighted below. The 8 way mimic board will appear in the left hand column as 01- Mimic 08 zone. This board will automatically be addressed as number 1 and will have the default operation attribute (all outputs on continuously when activated). By right clicking the Mimic icon in the left hand column and selecting edit settings the board can be configured as required. It can be allocated a different address (this must match the address physically set on the DIL switch on the board). The board can also be given a more meaningful, 15 character name which matches the location of the mimic panel such as Ground floor etc and the way in which the LEDs behave can also be selected to suit the application. Four different modes of operation can be chosen here. Syncro AS Matrix.docx Page 9 of 16

All outputs continuous This is the default mode and is how the mimic will operate if no other option is chosen. In this mode, whenever an LED output operates, it will light continuously as will successive LEDs. All LEDs will remain lit irrespective of whether the alarm condition has been silenced either at the main control panel or on a mimic panel. Flash outputs until silenced Any LED operated in this mode will flash until the alarm silence button is pressed either at the main control panel or at a mimic panel. When an alarm silence button is pressed, the flashing LED will light continuously. Further alarms will flash the LEDs associated with them until the alarm is silenced again. If the re-sound alarm button is pressed at the main control panel, any LEDs that were flashing and have become steady will flash again. Continuous on first activated output and subsequent to flash When this mode is chosen, the first LED operated will light continuously and subsequent LEDs operated will flash. Pressing the silence alarm button will not have any effect on the LEDs. Flash first activated output and subsequent to continuous When this mode is chosen, the first LED activated will flash and subsequent LEDs operated will light continuously. Pressing the silence alarm button will not have any effect on the LEDs. If LED outputs are controlled by cause and effects then the LED operation will be either flashing or continuous as defined in the cause and effect. All of the above modes will be overridden. If outputs are configured to flash when operated by cause and effects, they will turn off when an alarm silence button is pressed and flash again when resound alarm is pressed. If outputs are configured to be continuous when operated by cause and effects, they will switch off when an alarm silence button is pressed and will switch on again if resound alarm is pressed. If the mimic has more than 8 LEDs, then one or more 16 way boards will be fitted and will need to be added to the configuration file. To add a 16 way mimic board, highlight the control panel in the left hand column as before and double click on the Mimic 16 Zone icon at the bottom. Syncro AS Matrix.docx Page 10 of 16

It is possible to have more than one mimic panel on a system and each one will have its own 8 way mimic board, so when 16 way boards are added, Loop Explorer will ask for the address of the common 8 way mimic board to which the 16 way board will be connected. In the example shown here, there is only one 8 way mimic board which is set to address 1 but if more 8 way boards are fitted the addresses of all of the 8 way boards will be shown in the drop down box allowing the appropriate 8 way board to be selected. The example now shows the configuration file for a mimic with one 8 way board and one 16 way board so this mimic is capable of having up to 24 LEDs. Syncro AS Matrix.docx Page 11 of 16

To make it clear that the 16 way board just added, is part of the same mimic panel as the 8 way board previously added, the 16 way board can also have a 15 character name allocated by right clicking the 16 way board icon on the left. The example below now shows the 8 way board and the 16 way board with the same name indicating that they are part of the same mimic panel. When mimic boards are added to a configuration file, the 8 channels of 8 way boards are set by default to operate upon a fire condition (Default ring mode) and allocated to zones 1 to 8 respectively. Similarly, when 16 way mimic boards are added, these are set to operate upon a fire condition and are allocated to zones 9 to 24 respectively. These default settings will enable a simple, zonal fire mimic panel with up to 24 LEDs which operate continuously upon any fire alarm, to be configured very simply using the default settings. When further 16 way mimic boards are added, these will also be allocated to zones 9 to 24 and will need to be configured to the correct zones. The simplest way to do this is to use Zone Manager in the Loop Explorer programme. Each mimic board added will default to starting at Zone 1. To ensure that each output is mapped to their required zone; Click on the Zone Mgr icon in the menu bar at the top of the window and select the list view, then click on each zone and drag each output into the required zone. By clicking in all of the zones, the channels of the second 16 way mimic board can be moved to the required zones with this simple drag and drop method. Syncro AS Matrix.docx Page 12 of 16

Double clicking one of the channels displays a dialogue box where attributes for the individual channels of the mimic board can be set. The default setting is default ring mode which means that the channel will operate upon a fire condition, no delay, zone number and location text (matches zone number). Changing the Default ringing mode in the panel settings (common, zonal or 2 stage) Most mimic panels will be used to indicate a zonal fire condition and in this case, if the indication required is zonal, there is no need to change any of the device output properties. A zone name may be allocated if required. Some mimic panels however may require LEDs to be operated by particular devices, inputs or groups of devices and inputs. In this case, it will be necessary to write a cause and effect in the Loop Explorer programme to control the output. IF THE OUTPUT IS TO BE CONTROLLED BY CAUSE AND EFFECTS Def.Ring Mode (Fire) SHOWN UNDER DEVICE OUTPUT PROPERTIES MUST BE UNTICKED. 10 Changing or adding LED positions The construction of Syncro Matrix Mimic panels is such that it is simple to add, remove or change the position of LED indicators without the need for special tools or wiring. The indicators are fitted to a steel plate which has a matrix of holes on a 6 millimetre grid. The steel plate is covered by the printed building plan which reveals only the areas of the plate where indicators are fitted. If changes or additions are made to the building plan, a new building plan can be produced and fitted to an existing Syncro Matrix mimic panel. Syncro AS Matrix.docx Page 13 of 16

To add or change the position of an indicator, follow the fours steps shown below: Parts required for adding or changing LED positions on Syncro Matrix Mimic panels: Acrylic Drawing with or without controls. Z10102 Additional 16 way LED board (RED) Z10103 Additional 16 way LED board (YELLOW) Z10105 Additional 16 way LED board (GREEN) Z10042 Fibre optic cable (1 metre length) Z10044 Lens Fibre optic cable cutting tool or sharp razor blade 11 Maintenance and testing The mimic panel should be periodically tested at the same time as the rest of the fire alarm system in a systematic manner which ensures that all indicators show the correct information. Mimic panels with controls, have a lamp test facility which can be used to verify that all indicators and the internal buzzer are working correctly. The silence buzzer, silence alarm and reset controls should also be tested periodically. The mimic panels require little or no maintenance other than to ensure that the fascia is clean and clear of obstructions. If required, the fascia can be wiped with a barely damp cloth. Cleaning solutions other than those specifically designed for plastics such as anti-static spray cleaners should not be used. Mains powered versions of the mimic panels contain sealed lead acid batteries which are float charged. The batteries can be expected to provide adequate service for 3 to 4 years and should be tested annually in accordance with the manufacturer s recommendations. Batteries should be replaced with the same type at the end of their useful life. Syncro AS Matrix.docx Page 14 of 16

This page intentionally left blank. Syncro AS Matrix.docx Page 15 of 16

Syncro AS Matrix.docx Page 16 of 16