Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual

Similar documents
COLD WEATHER START KIT Ceiling Mount 4000

MINI PLATINUM SPLIT VERSION 3 TECHNICIAN S MANUAL

CEILING MOUNT. VERSION 2 TECHNICIAN'S MANUAL 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

CEILING MOUNT TWIN TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

PLATINUM SPLIT TWIN TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

MINI CEILING MOUNT VERSION 2 TECHNICIAN S MANUAL

PLATINUM SPLIT TECHNICIAN S MANUAL PS The Coolest Thing In Wine Storage

MINI PLATINUM SPLIT VERSION 3 OWNER S MANUAL. 24V Thermostat Conversion Kit Option

HM&VM TWIN S OWNER S MANUAL TWS The Coolest Thing In Wine Storage

Ceiling Mount OWNER S MANUAL

CEILING MOUNT TWIN TECHNICIAN S MANUAL

MINI SPLIT OWNER S MANUAL. 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

PLATINUM SPLIT OWNER S MANUAL. 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

CEILING MOUNT. VERSION 2 OWNER S MANUAL 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

CM2500 VERSION 2 TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option

Platinum Split TECH MANUAL

MAGNUM SERIES OWNER S MANUAL. Magnum SS9000 Magnum SS12000 QS

RAIN COLLECTOR HEATER

CM2500 TECH/OWNER S MANUAL

QUANTUM SERIES VERSION 2 OWNER S MANUAL. 24V Thermostat Conversion Kit Option. Quantum SS9000 Quantum SS The Coolest Thing In Wine Storage

WINE CELLAR I N T E R N A T I O N A L. Exclusive dealer of. Mini Ceiling Mount OWNER S MANUAL. The Coolest Thing In Wine Storage MCM

QUANTUM SERIES VERSION 2 TECHNICIAN S MANUAL. Quantum SS9000 Quantum SS The Coolest Thing In Wine Storage

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

CM2500 OWNER S MANUAL. 24V Thermostat Conversion Kit Option

MINI PLATINUM SPLIT VERSION 3 OWNER S MANUAL

QUANTUM SERIES VERSION 4 TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option. Quantum SS9000 Quantum SS The Coolest Thing In Wine Storage

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

KIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.

PLATINUM SPLIT VERSION 3 OWNER'S MANUAL. The Coolest Thing In Wine Storage

THERMOSTAT RETROFIT INSTRUCTIONS

SERVICE MANUAL FOR MODEL RM-10

SERVICE NUMBER: SERV-351

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

CEILING MOUNT VERSION 2 OWNER S MANUAL

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST PLYMOUTH BELVEDERE

Mini Split OWNER S MANUAL MSP The Coolest Thing In Wine Storage

PLATINUM SPLIT OWNER S MANUAL

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment

Section 2 Safety, Tools and Equipment, Shop Practices Unit 5 Tools and Equipment. Unit Objectives 3/1/2012. General Hand Tools (1 of 6)

SERVICE MANUAL FOR MODEL RM-49

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

WALL-MOUNTED & FULLY DUCTED VERSION 3 OWNER S MANUAL

SERVICE MANUAL FOR MODEL RM-26

Installation Instructions

Platinum Split OWNER S MANUAL

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

Undercounter Refrigeration

Crown Boiler Company

ONTIME TIMER SPECIFICATION

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

1956 FORD F-100 TRUCK

QUANTUM SERIES VERSION 2 OWNER S MANUAL. Quantum SS9000 Quantum SS The Coolest Thing In Wine Storage

EXTREME SERIES OWNER S MANUAL

an ISO 9001:2015 Registered Company

SLIMLINE 2500 & 3300 OWNER S MANUAL

VSA Series Air Dryer. User s Guide

HE360 Humidifier Installation Kit

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

F AN-ASPIRATED RADIATION SHIELD

Platinum Split OWNER S MANUAL FOR SYSTEMS EQUIPPED WITH: WATER COOLED CONDENSING UNIT PSWC The Coolest Thing In Wine Storage

Platinum Split OWNER S MANUAL

ELSTON 52 CEILING FAN

Owner s Manual LIMITED WARRANTY INFORMATION OBTAINING WARRANTY SERVICE FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS REGISTRATION

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

WALL-MOUNTED & FULLY DUCTED 9000 TWIN-S OWNER S MANUAL

Horizontal/Side Discharge Condensing Units

Heat Exchanger Block Replacement Instructions

Installation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT

DRAIN WATER TEMPERING INSTALL

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

Installation Instructions 30 French Door Built-in Wall Ovens

TK-1001, 1101, 1201, 1301, 1601

PHANTOM SERIES OWNER S MANUAL. 24V Thermostat Conversion Kit. Phantom 3500 Phantom 5000 Phantom The Coolest Thing In Wine Storage

Data Sheet. Self regulating heating tapes. RS stock numbers

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

Vapor-logic 3 to Vapor-logic4

ST. KITTS CEILING FAN

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

DRAIN WATER TEMPERING INSTALL

Super Deluxe Controller Assembly AC2089 & Base Kit AC2055

INSTRUCTIONS! DO NOT DISCARD!

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

Model: EF34. Owner's Guide & Installation Manual

OWNERS MANUAL. DrugPress 100 Operation and Service. Bienfang EQUIPMENT

HE220, HE260 Humidifier Installation Kit

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Water Distiller Service Manual

INSTRUCTIONS! DO NOT DISCARD!

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

WhisperKOOL EXTREME OWNER S MANUAL

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

TOUCHDOWN 48 CEILING FAN

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Transcription:

Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual Cold Weather Start Kit: To be used in conjunction with Platinum Split 4000 & Platinum Split 4000 Fully Ducted cooling system. The Coolest Thing In Wine Storage CWSK.PS4000 081715

Conforms to ANSI/UL Std 427 Certified to CAN/CSA Std C22.2 No. 120 We manufacture, test and certify 100% of our wine cooling units in the USA. By sourcing the best components and closely controlling our manufacturing processes, we can assure the highest-quality, lowest defect manufacturing rates in the industry. Copyright 2012. WhisperKOOL. All rights reserved. WhisperKOOL copyrights this manual, the product design, and the design concepts, with all rights reserved. Your rights with regard to the hardware and manual are subject to the restrictions and limitations imposed by the copyright laws of the USA. Under copyright laws, this manual may not be copied, reproduced, translated, transmitted, or reduced to any printed or electronic medium or to any machine-readable form, for any purpose, in whole or in part, without the written consent of WhisperKOOL. Every effort has been made to ensure that the information in this manual is accurate. WhisperKOOL is not responsible for printing or clerical errors. WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time, without notice. Vinothèque and WhisperKOOL are registered trademarks, and ECE is a trademark of WhisperKOOL. All rights reserved. Mention of third-party products is for informational purposes only and constitutes neither an endorsement nor a recommendation. WhisperKOOL assumes no liability with regard to the performance or use of these products. REV 02 CWSK.PS4000 081715

TABLE OF CONTENTS Receiving & Inspecting the Kit... 3 Before You Start... 4 Condensing Unit Cold Weather Start Kit Installation Instructions... 5 Evaporator Unit Cold Weather Start Kit Installation Instructions... 21 www.whisperkool.com Page 1

INTRODUCTION Customer Service Thank you for purchasing a WhisperKOOL Cold Weather Start Kit. We strive to provide the highest quality products and the best possible customer service. If you have any questions about your system, please call us at 1-800-343-9463 or visit WhisperKOOL.com. Using the Manual This Installation Manual is intended to provide detailed instructions for the installation of the Cold Weather Start Kit on the Platinum Split 4000 cooling system. In order to ensure the proper longevity of your cooling unit, the equipment should be installed as outlined in this Installation Manual. It is also vital to establish a proper care and maintenance schedule. Please read and review this Installation Manual carefully and keep it for future reference. What is a Cold Weather Start Kit? The Cold Weather Start Kit is designed to ensure that your cooling system will start in low ambient temperature. The Cold Weather Start Kit uses temperature controlled heaters on the receiver, in conjunction with an electronic bypass, to maintain a pressure inside the system high enough for proper operation. How Does the Cold Weather Start Kit Work? The Cold Weather Start Kit provides heat to specific components in the condensing unit for proper operation when the condensing unit is located in environments where temperatures drop below freezing. The Cold Weather Start Kit comes equipped with sensors to enable an ideal temperature boost every time. WARRANTY REGISTRATION In order to activate the warranty of your system, the Verification and Operational Documentation must be completed by the certified refrigeration technician installing your system and submitted via mail, fax or e-mail. Mail to: WhisperKOOL ATTN: Warranty Registration 1738 E. Alpine Avenue Stockton, CA 95205-2505 USA OR Fax to: 209-466-4606 OR Scan and e-mail to: warranty@whisperkool.com For the equipment warranty to be valid, WhisperKOOL requires that the installation is performed by a certified HVAC-R technician (NATE certified technician is recommended) per the specifications outlined in this Technician s Manual. The technician shall be required to be equipped with the proper tools of the trade including: R-134a, brazing equipment, dry nitrogen, an accurate manifold gauge set (digital preferred), plus a 4 valve manifold set for evacuation, digital micron gauge, digital scale, deep vacuum pump and accurate digital thermometers. Without the proper equipment, a professional job cannot be accomplished. Evidence of the certified tech s NATE# or other certification is required. Page 2 1-800-343-9463 CWSK.PS4000 081715

RECEIVING & INSPECTING THE KIT Receiving and Inspecting the Kit Inspect the packaging for any obvious signs of damage or mishandling before opening the container. Note any discrepancies or visual damage on the Bill of Lading before signing. Review the Packing Slip to Verify Contents Check the model number to ensure it is correct. STEP 1: If any items listed on the packing slip do not match your order information, contact WhisperKOOL Customer Service immediately. 1. Inspect the Kit before installation. If damage is found, please contact your distributor or WhisperKOOL Customer Service at 1-800-343-9463. 2. Verify that you have received all of the items on the Components Provided list below and that the Kit corresponds with your specific WhisperKOOL cooling system. 3. The system is intended for use in properly designed and constructed wine cellars. Hire a professional wine storage consultant with a valid contractor s license to build your wine cellar. 4. WhisperKOOL requires that all Cold Weather Start Kit Kits be installed by a certified HVAC-R technician only. 5. Warranty is not active until a Warranty Checklist has been received, reviewed, and approved. Condensing Unit Components Provided: (1) Cold Weather Start Kit Electrical Box Assembly (1) Silicone Heater Assembly (1) Thermal Switch Assembly (1) H2 Assembly (1) Paper Template (2) Hose Clamps (2) Yellow Female Disconnects (1) Red Female Disconnect (2) ½ Hex Head Self Tapping Screws (20) Zip Ties (1) Bag of Thermal Paste Platinum Split 4000 Cold Weather Start Kit Installation Manual Evaporator Unit Components Provided: (4) Lever Connectors (1) 120v/24v Transformers (with double sided tape on bottom edge for mounting) (5) Zip Ties (3 for install and 2 additional) Tools Needed: #1 Philips Head Screw Driver #2 Philips Head Screw Driver 5/16 Nut Driver 1/4 Nut Driver Drill Wire Cutters Wire Strippers Crimpers Needle Nose Pliers Utility Knife Step Bit (up to 5/8 ) Components Needed (Not Included): 2 Wire T-Stat Wire 18-20 AWG (Note: Enough to route from evaporator unit to condensing unit) After verifying that you have received all of the correct components for your specific system, please keep the Cold Weather Start Kit in its original box until you are ready for installation. This will allow you to move the product safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions. TIP: Save your box and all packaging materials. They provide the only safe means of transporting/shipping the unit. www.whisperkool.com Page 3

STEP 2: BEFORE YOU START Shut Off Power going to the Evaporator and Condensing Unit. Disconnect both the evaporator unit (Air Handler) and the Condensing Unit from each power source. WARNING: Failure to do so may cause electrical shock which can result in injury or death. A 2 wire 18-20 awg thermostat wire will need to be ran from the evaporator unit to the condensing unit prior to installing the Cold Weather Start Kit. Review the Tools Needed and Components Provided document prior to starting. Page 4 1-800-343-9463 CWSK.PS4000 081715

CONDENSING UNIT COLD WEATHER START KIT INSTALLATION INSTRUCTIONS 3 Remove the electrical box cover. 4 Remove the sticker backing from the paper jig and stick to the side of the existing electrical box as shown. (The cross should be slightly offset to the right.) 5 Using a step bit, drill a 5/8 hole through the cross. (Be sure not to drill into the electrical components.) 6 Route the 4 wires from the Cold Weather Start Kit box into the existing electrical box as shown. www.whisperkool.com Page 5

7 Remove the backing on the double sided tape as shown. 8 Remove the backing on the double sided tape as shown. 9 Line up the back of both boxes and stick the Cold Weather Start Kit box to the condensing unit and existing electrical box. 10 Cut the 3 zip ties around the hot and neutral wires off as shown. Page 6 1-800-343-9463 CWSK.PS4000 081715

11 Reorganize the wires in the H lever connector as shown. 12 Reorganize the wires in the N lever connector as shown. 13 Secure the #6 wire into the H2 lever connector. 14 Secure the #7 wire into the H2 lever connector. www.whisperkool.com Page 7

15 Secure the #5 wire into the N lever connector. 16 Secure the #8 wire into the H lever connector. 17 Remove the blue flag connector from the #1 terminal on the Delay on Break Timer. 18 Cut the blue flag terminal off the black wire from the previous step. Page 8 1-800-343-9463 CWSK.PS4000 081715

19 Strip the end of the black wire from the previous step to a length of 3/8. 20 Crimp the yellow female disconnect labeled 1 onto the #11 wire and the black wire from the previous step. 21 Connect the yellow female disconnect labeled 1 to the #1 terminal on the Delay on Break Timer. 22 Disconnect the yellow female disconnect from the #3 terminal on the Delay on Break Timer. www.whisperkool.com Page 9

23 Cut the yellow female disconnect off of the two wires from the previous step. 24 Strip the ends of each of the two wires from the previous step to a length of 3/8. 25 Crimp the red female disconnect labeled 3 onto the black wire from the previous step. 26 Connect the red female disconnect labeled 3 to the #3 terminal on the Delay on Break Timer. Page 10 1-800-343-9463 CWSK.PS4000 081715

27 Twist the strands of the blue wire from Step 24 with the #10 wire. 28 Crimp the closed end terminal onto the #10 wire and the blue wire from the previous step. 29 Locate the silicone heater assembly. 30 Loosen the two screws on the cord squeeze on the existing electrical box. www.whisperkool.com Page 11

31 Route the two long white wires from the silicone heaters up into the electrical box. 32 Twist the strands of each heater wire together. 33 Secure the two heater wires into the N Lever connector. 34 Route the #9 wire with the red disconnect labeled T down through the cord squeeze. Page 12 1-800-343-9463 CWSK.PS4000 081715

35 Remove the backing from one silicone heater. 36 Stick the silicone heater to the receiver as shown. Line up silicone heater wires with the stud on the back of the fan motor. The top of the heater should be 2.5 from the top of the receiver. 2.5 37 Remove the backing from the other silicone heater. 38 Line up the back edge of the second heater with the back edge silicone heater already on the receiver and stick into place. www.whisperkool.com Page 13

39 Secure 2 hose clamps around the top and bottom of the silicone heaters as shown. 40 Slide the thermal switch assembly over the top of the receiver as shown. 41 Secure the blue female disconnect labeled T onto the bottom terminal of the thermal switch. 42 Secure the red female disconnect labeled T onto the top terminal of the thermal switch. Page 14 1-800-343-9463 CWSK.PS4000 081715

43 Zip tie thermal switch and heater wires as shown. (5x) 44 Zip tie wires in locations shown. 45 Route the 24v thermostat wires through the cord squeeze into the electrical box. 46 Remove the 4 Phillips head screws on the Cold Weather Start Kit Electrical Box. www.whisperkool.com Page 15

47 Remove the top cover from the Cold Weather Start Kit Electrical Box. 48 Route the 24v thermostat wire through the hole in the boxes into the Cold Weather Start Kit Electrical Box. 49 Connect one of the 24v thermostat wires to the #13 wire using the wire nut provided. 50 Connect the 24v thermostat wire to the #12 wire using the wire nut provided. Page 16 1-800-343-9463 CWSK.PS4000 081715

51 Tuck wires in Cold Weather Start Kit Electrical box as shown. 52 Using the 2 provided ½ self tapping screws, secure the 24V coil relay to the Cold Weather Start Kit box through the predrilled holes. (Failing to use the provided screws and mounting locations may result in a punctured coil.) 53 Tuck wires in electrical box as shown. 54 Make sure that the Bypass Timer is set to 1000 seconds. www.whisperkool.com Page 17

55 Make sure that the Delay On Break relay is set to 5 minutes. 56 Secure the 2 screws on the cord squeeze. 57 Secure both tops back onto the electrical boxes using the removed screws. 58 Cut the corner of the bag off as shown. Page 18 1-800-343-9463 CWSK.PS4000 081715

59 Place thermal paste on the flat surface of the thermal switch. 60 Be sure the thermal switch is making good contact with the receiver under the ridge. The Cold Weather Start Kit has been successfully installed on the condensing unit, next proceed to the evaporator unit instructions. www.whisperkool.com Page 19

NOTES Page 20 1-800-343-9463 CWSK.PS4000 081715

EVAPORATOR UNIT COLD WEATHER START KIT INSTALLATION INSTRUCTIONS 1 See page 4 before continuing to the next step. 2 Before beginning the installation process, locate the Evaporator Unit Cold Weather Start Kit. All parts for the Evaporator Unit are located inside of this box. 3 Open box and remove the 24v transformer and the zip lock bag. 4 The kit will include five zip ties, four lever connectors, and one 120v/24v step down transformer. 5 Wall Mounted Units Using a Phillips head screw driver loosen the 2 Phillips head screws on the front panel. (Note: The screws do not come out of the panel.) www.whisperkool.com Page 21

6 Wall Mounted Units Pull front panel away from the unit to remove it. Set panel aside. 7 Ducted Units Using a Phillips Head Screw driver loosen the 4 screws on the ducting panel, make sure screw comes all the way out of the housing of the unit. (Note: The screws do not come out of the panel.) Pull ducting panel away from the unit to remove it. 8 Remove the panel. 9 Remove the thumbscrew by rotating it counter clockwise. (Set thumbscrew aside for later use.) Page 22 1-800-343-9463 CWSK.PS4000 081715

10 Pull electrical panel out and let hang as shown. 11 Remove the backing from the double sided tape on the bottom and side edges of the transformer. 12 Place flange of the transformer between the control box and the flange of the electrical panel, place the other flange underneath the grommet. Press transformer firmly in place. 13 Locate one of the white wires coming out of the push connector. Cut one white wire and strip both ends to a length of 3/8. www.whisperkool.com Page 23

14 Secure the two white wires from the unit and the white wire from the transformer into a lever connector. 15 Locate the blue wire coming out of the Molex connector. Cut the blue wire and strip each end to a length of 3/8. 16 Secure the blue wires from the unit and the black wire from the transformer into a lever connector. 17 Secure one of the t-stat wires and the blue wire coming from the 24v side of the transformer into a lever connector. Page 24 1-800-343-9463 CWSK.PS4000 081715

18 Secure the other t-stat wire and the yellow wire coming from the 24v side of the transformer into a lever connector. 19 Zip tie wires in locations shown. 20 Slide the electrical panel back into place and re-install the thumb screw. 21 Wall Mounted Units Push front panel back on the unit, and tighten the 2 Phillips head screws on the front panel to the unit. www.whisperkool.com Page 25

22 Ducted Units Push ducting panel back on unit and tighten the 4 screws on the ducting panel to the unit. The Cold Weather Start Kit has been successfully installed on the Evaporator Unit. If the installation process is complete on the condensing unit as well, plug both the condensing unit and evaporator units back into a power source. Page 26 1-800-343-9463 CWSK.PS4000 081715

NOTES CWSK.PS4000 081715

WhisperKOOL 1738 E. Alpine Ave Stockton, CA 95205 1-800-343-9463 www.whisperkool.com CWSK.PS4000 081715