Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Similar documents
Lodam Heat Pump Controller. User manual. Version 5.0. LMC320

Lodam Condensing Unit Controller. Modbus Interface. Version 2.0 LMC341 DIWE

DTA. Motor thermistor relay. Benefits. Description

DTA04. Motor thermistor relay. Benefits. Description

Instructions for the fan motor control system with integrated wiring terminals SILVER C

I/O ZONE 560/583 AND OPERATION MANUAL

Instructions for the fan motor control system, SILVER C

Part 3 Troubleshooting

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Operating Manual MS220KA and MSR220KA

Trouble Shooting Guide FAA, 3-phase (D3631)

Trouble Shooting Guide PWA, 3-phase (D10571)

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

ISIS SAFETY SYSTEM Installation guide

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

MBCE-110/230UV Flame Sensor Module

Process Alarm Module RTA 421

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Operator: Save these instructions for future use!

REPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

ACS-30-EU-EMDR- 10-MOD

USER-MANUAL Tamson Cool Cube Immersion Cooler

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Operator: Save these instructions for future use!

LGA... Gas Burner Controls. Building Technologies Division

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET-2000 Hi Level/Oil

SITESTAR CABINET DESCRIPTION

Monitoring Devices 11/1

Wiring Diagrams Units Produced After April 20, 2009

SET Installation and Operating Instructions. Level switch for one sensor

Power Supply Display Module PSDM. Installation and Operation Manual

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Trouble Shooting Guide RAA, 1-phase (D3627)

C Note! LGI16... Burner Controls. Building Technologies

Trouble Shooting Guide PAA, 1-phase (D3731)

03.03.mmm REV.2 09/01

Room thermostats with LCD for wall mounting

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

1. Instruction. 1.5 Warranty Comar Condensatori S.p.A. guarantees its own products for twelve months from purchase

Operating Manual MS220DA

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Operating Instructions. For. Alarm Control Module. Model SSR 500

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Flame Safeguards LFE10. Building Technologies HVAC Products

BasicTroubleshooting Information and Guidelines

Hydra Negative Pressure, Closed-Loop Mold Temperature Controllers INSTRUCTION MANUAL

Door Release Power Supply

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

User Manual 120/240/300 Outdoor Motion Detector

OilSET-1000 (12 VDC)

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to

02/11/2015

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Operator: Save these instructions for future use!

MODEL B2 INSTALLATION MANUAL

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Pneumatic Heat Press. Revision: 3 Operators Manual

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

SCHMIDT LED Measured Value Display MD Instructions for Use

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Heat Pump Defrost Board Replacement Kit

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

User Guide

Installation, operating and servicing instructions

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

WaterFurnace FX10 Application Guide Reversible Chiller

EARTH FAULT METER MD-08

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

KIT IOM

RE-PR3-E-27 3-Phase Panel Mount 27kW

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Transcription:

Lodam Compressor Protection Module Technical manual Version 3.0 SE-G1

Contents 1. Read this first... 4 1.1. Reading instructions... 4 1.2. User manual... 4 1.3. Safety... 4 2. General... 5 3. Definitions... 5 4. How to...... 6 5. Functions... 7 5.1. Temperature monitoring... 7 5.2. Rotation direction monitoring... 7 5.3. Phase failure monitoring... 7 6. Examples of application use... 8 6.1. Connection... 8 6.2. Compressor with soft starter... 9 6.3. Legend for the schematic diagrams... 10 6.4. Technical data... 11 7. Drawings... 12 8. Standards... 13 9. Trouble shooting... 13 10. Index... 14 11. Notes... 15 Page 2

Technical manual SE-G1 Page 3

1. Read this first The contents of this manual are subject to change without notice. Lodam electronics holds the copyright to this user s manual. The user shall follow any instructions given in this user manual entirely and not only partly. Any non-following of this user manual result in exclusion of all warranties, guarantees, and liabilities. Copyright 2014 by Lodam electronics a/s. All Rights Reserved. Disposing of the parts of the controller: INFORMATION FOR USERS ON THE CORRECT HANDLING OF WASTE ELECTRI- CAL AND ELECTRONIC EQUIPMENT (WEEE) In reference to European Union directive 2002/96/ EC issued on 27 January 2003 and the related national legislation, please note that: 1. WEEE cannot be disposed of as municipal waste and such waste must be collected and disposed of separately; 2. The public or private waste collection systems defined by local legislation must be used. In addition, the equipment can be returned to the distributor at the end of its working life when buying new equipment; 3. The equipment may contain hazardous substances: the improper use or incorrect disposal of such may have negative effects on human health and on the environment; 4. The symbol (crossed-out wheeled bin) shown on the product or on the packaging and on the instruction sheet indicates that the equipment has been introduced onto the market after 13 August 2005 and that it must be disposed of separately; 5. In the event of illegal disposal of electrical and electronic waste, the penalties are specified by local waste disposal legislation. 1.1. Reading instructions The following symbols are used to draw the reader s attention to different warning levels. Importan information. Danger!! General danger. Danger!! High voltage. Danger of electrical current or voltage. 1.2. User manual Before installation the user should be thoroughly familiarized with this user manual, especially with purposes, installation and operation. Special care should be taken when installing and connecting external equipment (PTC sensor, high voltage etc) and handling the modules correctly according to protection against ESD. Installation of the SE-G1 must be performed by authorized personnel only. All warranties are excluded in case installation is performed by unauthorized personnel or in case the SE-G1 has not been correctly installed. 1.3. Safety The SE-G1 is a protection device and not a safety component according to the Machinery Directive and can not be used in medical or life support equipment. Before plant commissioning the service technician shall ensure that personal safety requirements are met in conformity with the Machinery Directive on the basis of safety estimations. Electrical plant failures are to be immediately solved, even though no immediate danger exists; the SE-G1 and motor must be without power. Page 4

Technical manual SE-G1 2. General 3. Definitions The protection device SE-G1 is used for protection of scroll compressors equipped with softstarters. Its relay is used in the safety chain for the compressor and will open in case of a failure. Different scenarios can threaten the lifetime of the compressor where the SE-G1 can protect: Overheating: The SE-G1 will protect against overheating by monitoring motor temperature by means of PTC-sensors mounted in the motors windings or in the hotgas. In case of overheating, the module will lock out and open the relay. Product range Definitions ESD Electro Static Discharge HW Hardware/electronics NC Normally Closed (relay) NO Normally Open (relay) PTC Positive Temperature Coefficient (sensor element) Wrong rotation direction: The SE-G1 monitors the rotation direction of the phases at compressor start and will lock out and open the relay in case of wrong rotation direction. Phase failure: If a phase is missing at start up, SE-G1 opens the relay for 6 minutes. After this period a start is allowed again. Only a number of retries are allowed before a permanent lock out is performed. The SE-G1 first starts monitoring of the phases 5 seconds after start-up to allow the system with the softstarter to become stable. Page 5

4. How to... Use the SE-G1 with a Scroll compressor Terminal box Control External Safety 11 R Contactor coil 14 L Alarm lamp 12 2 Blue Brown Black 1 N Reset L SE - G1 Optional discharge gas temperature sensor L 2 M1 L 3 L1 M2 Page 6

Technical manual SE-G1 5. Functions If the measured PTC resistance is above 11,4 kω: The relay is not energized and the module is locked and must be powered off to be released. The SE-G1 has several monitoring functions which are listed in the following. 5.1. Temperature monitoring One of the functions of the SE-G1 is to work as a motor protection module. By monitoring the resistance in a PTC sensor, it will open its relay when the resistance of the PTC sensor increases above the limit as shown below. The PTC-sensor could for example be according to DIN 44081/82. The resistance of these PTC-sensors is not linear but give a well-defined steep rise in resistance when the threshold temperature of the PTC-sensor is reached. This is detected by the protective device and the relay is released and thereby cutting the control power as shown on the diagram below. 5.2. Rotation direction monitoring The SE-G1 waits 5 seconds after compressor start for the softstarter and then the 3 phases for the compressor are monitored for 5 to 10 seconds against wrong rotation direction (wrong phase sequence). In case of a wrong rotation direction, the relay is immediately de-energized and the SE-G1 locks. A manual reset must be done by removing power from the module for minimum 5 seconds and then applying it again. When the compressor is stopped, a pressure difference in the compressor can make it turn backwards and thereby generating a false phase sequence. Therefore the detection of phase sequence is disabled the first 10 seconds after a compressor stop to avoid a false alarm condition. Alarm On Lockout Relay 14 11 12 5.3. Phase failure monitoring Phase failure monitoring waits for the softstarter and is On started 5 seconds after compressor start. In case of a phase loss during the first 5 to 10 seconds of monitoring Relay the SE-G1 de-energizes the relay and thereby breaks the Off 14 11 12 security chain. PTC temperature 2.9 kohm 11.4 kohm RPTC Since the increase in resistance is so steep, from 1 up to 9 PTC-sensors can be coupled in series without raising the actual temperature threshold more than a few degrees Celsius. If the module is in the locked state, a manual reset must be done by removing power from the module for minimum 5 seconds and then applying it again. The count of the 4 events in sequence is reset when start is detected with no phase loss. There is a restart blocking function to prevent a motor from being started too soon after having been overheated. A manual reset must be done by removing power from the module for minimum 5 seconds and then applying it again. When power is turned on to the SE-G1 module, the PTC resistance is measured: If the measured PTC resistance is below 2,9 kω: The relay is energized immediately If the measured PTC resistance is between 2,9 kω and 11,4 kω: The relay is first energized when the resistance is below 2,9 kω - i.e.the compressor has cooled down. Page 7

6. Examples of application use 6.1. Connection 53 4,5 3,2 Terminal Description L Power supply N Neutral Unnamed PTC element two wires 11 Relay common 12 Relay NO Error condition 14 Relay NC Ok condition Page 8

Technical manual SE-G1 6.2. Compressor with soft starter 1 2 3 4 5 6 7 8 9 10 11 12 L1 L2 L3 N PE F1 1 0 Q1 F4 F3 4A F2 0 1 S1 K1 8 K1 8 S2 B1 K2T 9 F13 8 F5 P> K1 8 K1 8 N1 B1 ϑ F6 P< L1 - Black L2 - Brown L3 - Blue M1 L1 L2 L3 1 2 L SE-G1 11 N 12 14 1 2 M3 3 ϑ R1..6 3 F13 2 4 R7 5 R8 6 7 H1 K1 K2T Y1 300s Page 9

6.3. Legend for the schematic diagrams Legend B1 Control unit F1 Main fuse F2 Compressor fuse F3 Control circuit fuse F4 Oil heater fuse F5 High pressure limiter F6 Low pressure limiter F13 Thermal motor overload relay H1 Signal light Compressor fault K1 Motor contactor K2T Time relay Short cycling delay M1 Compressor N3 Soft starter (ramp up time < 2s) Q1 Main switch R1-6 PTC sensors in motor windings R7 PTC Discharge gas temperature sensor R8 Oil heater S1 Control switch S2 Manual reset Y1 Liquid Line Solenoid Valve Page 10

Technical manual SE-G1 6.4. Technical data Technical specifications Operation voltage 110-277 VAC, 50-60Hz, 3VA Motor voltage Permitted ambient temp. 200...600V +/- 10%, 50/60 Hz -30 C ~ +60 C Relay Switch voltage 250V ~ Continuous current max. 2.5A Swiching capacity 300VA, C300 Relative humidity 5% - 95%RH, non condensing L1, L2 and L3 cable Length 300 mm Connector Ring connector for 1/4 stud L1 Black L2 Brown L3 Blue PTC measuring circuit Fuse required Enclosure class Sensor type: Thermistors according to DIN 44081/82, thermistor type: 1-9 in series R total < 1,8 kω Switching point: Relay off > 11,4 kω +/- 5% Relay on < 2,9 kω +/- 5% 4A quick blow Terminals IP00 Terminals Spade connectors 6,3 mm * 0,8 mm / 1/4 Field wiring markings Use 60 C copper conductors only Page 11

7. Drawings Mounting is for standard rail 35 mm according to DIN EN 60715 or with screws. 68,3 26 16 3,0 10,0 80,5 35,3 3,2 4,5 53 Page 12

Technical manual SE-G1 8. Standards 9. Trouble shooting The product is manufactured according to the following standards. RoHS 2002/95/EC Low voltage 206/95/EC 61010-1 Safety requirement for electrical equipment for measurement and control EMC 2004/108/EC Check if there is power to the unit according to specification. If the power is ok: Turn off the power for 5 seconds and see if the relay is energized after power on again. If not, turn off all the power to avoid risk of injury! 61000-6-x Generic EMC The following standards have been used EN 61010-1 Safety requirement for electrical equipment for measurement and control EN 61000-6-1 Immunity for domicil, profession and light industry EN 61000-6-3 Emission for domicil, profession and light industry UL 508 UL file number: E334756 Unmount one of the cables to the PTC element in the motor If the measured resistance is above 11,4 kω ±5%, the temperature of the PTC-sensor is above the threshold limit and the relay has been released to protect the motor or installation. If the measured resistance is more than 1 MΩ, there is a broken connection to the PTC-sensor and the relay will not be engaged. If the measured resistance is close to 0 Ω, there is a short circuit on the PTC-sensor cables and there is no overheat protection! If all three phases are within range and resistance is below 2.9 kω ±5%, the protection module may be defect and needs replacement. Page 13

10. Index C Compressor with soft starter 9 Connection 8 D Definitions 5 Drawings 12 F Functions 7 H How to... 6 M Motor voltage 11 Mounting 12 O Operation voltage 11 P Phase failure monitoring 7 R Rotation direction monitoring 7 S Standards 13 T Technical data 11 Temperature monitoring 7 Trouble shooting 13 Page 14

Technical manual SE-G1 11. Notes Page 15

Innovative and energy saving climate control When it comes to climate control Lodam is one of the most experienced you can turn to. For more than four decades we have developed, produced and implemented electronic solutions dedicated to optimising applications like: Compressors Condensing units Heat pumps Air conditioning Refrigerated truck and trailer Reefer containers We know the importance of reliable, energy-efficient operation and constantly push technological boundaries to bring you the most innovative and forward-thinking solutions. As part of the BITZER Group we are backed by one of the world s leading players in the refrigeration and air conditioning industry. This alliance provides us with extensive network and application knowhow and allows us to stay at the forefront of climate control innovation. And to help ensure comfortable surroundings for humans and reliable protection of valuable goods anywhere in the world. 23-01-2015 Contents are subject to change without notice. Lodam electronics a/s Kærvej 77 6400 Sønderborg Denmark Tel. +45 7342 3737 Fax +45 7342 3730 lodam@lodam.com For more information visit: www.lodam.com