Polypro Acid Wet Bench UCLA Nanolab Yellow Room. Primary contacts: Max Ho, Wilson Lin. PREPARED BY: Steve Franz DATE Rev 2/01/12

Similar documents
Amerimade RCA Wet Bench SOP Page 1 of 13 Rev /22/2014

R I T Title: RCA Bench #2

Standard Operating Manual. Ultra Fab Wet Station F Non-standard Processing Station

Wet Bench Standard Operating Procedures

R I T Title: Manual Processing Bench #2 Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 08/05/2008

General Acids/Bases Bench Right and Left SOP

Operation Procedure for SMiF Wet Hoods (Solvent, Spin Coat, Acid, and Develop Hoods)

Standard Operating Manual. PEL Wet Station X Clean Organic Solvent Station

Standard Operating Manual. Ultra Fab Wet Station C Oxide/ Nitride Etch Station

DT968C C.T. BATH CONTROLLER

Liftoff/Strip Solvent Bench SOP

Acid / Base Bench Procedures and Operation Manual

Title: Nitride and Silicon Wet Etch Semiconductor & Microsystems Fabrication Laboratory Revision: I Rev Date: 01/20/2010

ROTOR COATING WET BENCH OPERATING PROCEDURE

Haz Waste Management

Standard Operating Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

CAREL IR33+ CONTROLLER

GENERAL WET BENCH SAFETY AND USES SOP. October 2013 GENERAL SAFETY RULES

DC200 Digital Dispenser Operating Manual

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

O PE R AT I ON HO851G REVOLVING TRAY OVEN. MODEL HO851G GAS ML Pan ML Pan ML Pan ML Pan

Follett Performance Plus

PDS 2010 Parylene Coater SOP

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

CA5000 Liquid CO 2 Freezer Backup System

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Installation, Operation & Maintenance Manual. Wash System

Revised: January 8, Goal: Deposit, expose, and develop standard positive photoresist films as an etch mask, liftoff mask, or sacrificial layer.

Experiment #6 Photolithography: Microprocessing Technology Fabrication of the microstructures with SPR photoresist

Operating instructions Page 12

Operation Guide 3408

Note: The oven function will not work if the time of day clock is not set. Pad- Used to to start all oven. Timer or Oven Light. Timer On/Off.

Safety In Chemistry. Identified Risks and Hazards

Contents. Manufacturing Inc.

Steamist Installation Guidelines

Operation Guide 5510

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

OPERATION MANUAL Model 800 Nanoimprint Controller

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Ultrasonic and Megasonic Cleaners

CSP-204 CSP-208 CSP-104 CSP-108

DYGIZONE GJD910 Lighting Controller & Enunciator

Clean Water Made Easy

CryoPod Carrier. Quick Start Guide. English Quick Start Guide, 2 Français Guide de démarrage rapide, 8 Deutsch Schnellstartanleitung, 14

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual

CORNELL Emergency Response Systems

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

Standard Operating Procedure Glovebox and Thermal Evaporator

Digital Precise Air Control - DPAC

PDMS Casting Station Supplies

Operating instructions Page 14

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

QD-ENG-68 Controller for Thermoelectric Thermal Management

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

1. Conduct yourself in a responsible manner at all times in the laboratory.

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

The University of Washington Nanofabrication Facility (WNF) at Fluke Hall 125 Fluke Hall Seattle, WA 98195

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

HARDWIRED CONTROL PANELS

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

INSTALLER S & OWNER S MANUAL

Lab Safety. Section 2L. Chemistry I & II

INSTALLER S & OWNER S MANUAL

Plasma-Therm 790 RIE (Reactive Ion Etcher) Basic Operation Guide

Hand Dryer Installation & User Manual

K 3.97 M. Specifications or visit our website: In USA call: Part No

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Summary of Keypad Main User Commands

Product Manual SZ1009

Summit 3208GLD USER MANUAL. Electronics Line

Product Manual SZ1022/SZ1031/SZ1035/

NX-148 LCD CODE PAD TABLE OF CONTENTS

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

1. Conduct yourself in a responsible manner at all times in the laboratory.

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

PORTABLE ENGINE HEATER AND EXTERNAL BATTERY CHARGER. Specifications: Benefits: IN: NC:

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

(Place Logo from Lab here)

16 and 16 plus User s Guide

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

leisure series manual YxtàâÜ ÇzAAA The Spirit The Oasis The Mirage The Wish relaxing your world

Operating instructions

TRUE INDUCTION DOUBLE BURNER TI-2C PORTABLE INDUCTION COOKTOP MANUAL

Instruction Manual for Bench-Top Cleaning Baths

Application Data Sheet

Transcription:

Polypro Acid Wet Bench UCLA Nanolab Yellow Room Primary contacts: Max Ho, Wilson Lin PREPARED BY: Steve Franz DATE Rev 2/01/12 1

PolyPro Acid Wet Bench 1.0 SCOPE This document establishes the procedures for using the polypro acid wet bench located in the Nanolab Yellow Room. Only trained users may use this bench. Additional hot plates, ultrasonic cleaners, plating tanks etc are NOT to be used at this fume hood without permission from the lab staff. Unused beakers are NOT to be stored at the sink. All baths should be covered when not in use. Chemical -proof visor, apron and gloves must be worn whenever pouring chemicals. All chemicals must be labeled with chemical name, user, phone #, date & time started and finished. 2.0 APPLICABLE DOCUMENTS Appropriate log books, MSDS sheets for chemicals used. Operating Instructions for Modutek Dump Rinsers, Controllers and Timers 3.0 MATERIALS AND EQUIPMENT Polypro wet bench, appropriate chemicals and chemical beakers (optional). 4.0 DECK LAYOUT The polypro wet bench located in the Nanolab Yellow Room, is designated for acid and base cleaning and etching. It is not intended for solvent cleans, HMDS or work with flammable chemicals. Use the stainless steel solvent sink for these operations. Observe all warnings and cautions when using this bench. The deck layout is shown in Fig 1 and is described below: Fig 1. Polypro Wet Bench for Acid Processing A, F 2 temperature controlled heated baths with drains, level sensors and over-temperature protection. Bath A is designated for organic clean eg piranha or ammonium hydroxide solutions. Bath F is designated for inorganic strips such as HCL/ peroxide cleans. Liquid levels must be filled past the white/black line and BOTH drains must be closed. A dedicated log book for each hot pot is kept at the fume hood and must be filled out for EACH use as well as dumps and fills. Always label the cover with pot s contents. 2

B, E 2 beaker tanks. Do NOT pour chemicals directly into tank. Tanks may be used for any unheated soaking in acids or bases. Do NOT use these tanks for solvents. C D G A time-controlled hot plate for etching or cleaning (No Solvents). Temperature is set at the hot plate and a magnetic stirrer control is also located at the hot plate. The cover MUST BE REMOVED during heating or it may melt. An integrated timer shuts off the hot plate after 4 hours. A set of 2 aspirators used only in emergency or for draining water after rinsing out tanks. City water is used to create suction and aspirate the solution to the drain therefore chemicals must NEVER be aspirated. Gooseneck sink for rinsing and filling with DI water. (Note that ALL water is DI except at the aspirator.) There are 2 valves for the gooseneck, one at the neck itself, which should be adjusted to get the desired flow and another on the front of the fume hood used as an on/off valve. H, N 2 Sets of N2 blow guns and DI rinse guns. Both guns should recoil back into the recessed wells when done. Note that DI water resistivity and temperature may be monitored from the headcase resistivity display (see later in spec). I, M 2-2 stage cascade DI water rinsers with N2 bubblers in the 1st stage. Substrates should always begin in the bubbler (dirty) tank and finish in the non-bubbler (clean) tank. The correct order is tank 1 and then tank 2. On/off for both the water flow and bubbler is located in the headcase. USE ONLY THE AMOUNT OF WATER ABSOLUTELY NEEDED. Using more than required or "forgetting to turn it off" can drain our storage tank and shut down the lab. Each cascade can accommodate up to a 6 inch wafer cassette. J, L A set of 2 DI water dump rinsers. Rinsers are preset to 5 cycles but are programmable. See lab staff for special applications requiring changes. Each rinser can hold up to one 6 inch cassette. K O Hydrofluoric acid etch tank. EXTREME CAUTION is required in using this tank which is unheated but connected to the HF drain. Always label the tank with the concentration being used ie 10:1, 6:1 etc. BOE may also be used in this tank and must be so labeled. MAKE SURE BOTH DRAIN VALVES ARE CLOSED BEFORE POURING CHEMICALS. The drain for this tank is controlled by the process controller (item A in Fig 3.). Fill out the log book after EACH use OR whenever refilling the tank. Set of 3 manual drain and waste bottles for hot bath 1 and 2 and the HF tank. Extreme caution must be exercised when draining chemicals ie empty bottle in place, solution cooled down and manual valve opened slowly. Use a prelabelled waste bottle (labels are provided in the yellow room) and always watch while draining and shut off all drain valves when done. 5.0 HEADCASE AND MODULE CONTROLS All of the controllers, timers and electronics are located in the head case above the fume hood. Additionally, the magnehelic gauge to verify fume hood exhaust is located at the extreme right of the headcase. You must always verify that the gauge's needle is in the safe zone BEFORE using the hood. 3

5.1 Left Side Headcase (refer to Fig 2). Fig 2 Left Side Headcase and Controls for polypro acid sink A Emergency Power Shut Off: Turns off power to entire sink. B Power Light Indicator: Lit if power is active to the hood. C Independent programmable timer for timing various processes. Timer may be programmed up to 99 minutes and will give an audible alert when set point is reached. See more detailed explanation in timer section. D Temperature controller for heated tank (A in Fig 1). See separate section for its operation. An integrated timer will shut off the timer after 4 hours. Additionally a level sensor will shut down the power if the liquid level is too low. The tank may also be drained using the controller. ALWAYS TURN OFF POWER WHEN FINISHED PROCESSING. E Top is pneumatic cascade water switch (clockwise for on) and its indicator light above it. Bottom is a pneumatic bubbler switch with its indicator light above it. These controls are associated with the rinser/bubbler labeled I in Fig 1. Turn off DI water as soon as you finish. F Dump rinser controller for item J in Fig 1 pre-programmed for 5 dump cycles. See separate section for controller operation. G Light switch (top): Turns on yellow lights for entire fume hood. Turn lights off when not in use. Aspirator (bottom) (D in Fig 1): To be used only in emergency or for aspirating water eg rinsing tanks. 4

5.2 Center Headcase (refer to Fig 3). Fig 3 Center Headcase and Controls for Polypro sink A B C D E HF tank drain valve and indicator. Clockwise opens valve. Make sure HF-compatible labeled empty bottle is in place, and slowly open manual valve to drain liquid. DO NOT LEAVE UNTIL THE SOLUTION IS TRANSFERRED TO A PRELABELED WASTE BOTTLE AND CLOSE ALL DRAIN VALVES IMMEDIATELY AFTER FINISHING. Remove and store waste bottle in designated area. Hot plate timer (C in Fig 1) automatically shuts off after 4 hours. Controls time only, temperature is controlled directly at hot plate. Stirrer is also controlled directly at hot plate. CAUTION: KEEP POLYPRO COVER OFF WHEN USING HOT PLATE AND TURN OFF HOT PLATE WHEN FINISHED. Set of sonoalerts associated with various controllers. Press the appropriate silence button when alarm sounds. Set of 2 stand alone timers for timing various processes. Timers may be programmed up to 99 minutes and will give an audible alert when set point is reached. See more detailed explanation in timer section. 2nd dump rinse controller for rinser L in Fig 1. Dump rinser is pre-programmed for 5 cycles and can accommodate up to one 6 inch wafer cassette. 5

5.3 Right Side Headcase (refer to Fig 4). Fig 4 Right Side Headcase and Controls A B C D E F Right aspirator (D in Fig 1): To be used only in emergency or for aspirating water. Temperature controller for heated tank (F in Fig 1). See separate section for its operation. An integrated timer will shut off the timer after 4 hours. Additionally a level sensor will shut down the power if the liquid level is too low. The tank may also be drained using the controller. ALWAYS TURN OFF POWER WHEN FINISHED PROCESSING. Fill out the log book after each use and whenever the chemical is changed. Cascade water switch and indicator (top) and bubbler switch and indicator (bottom). Used to control cascade rinse, M in Fig 1. Turn off DI water as soon as you finish. DI temperature/resistivity water display. Press "Display" button to toggle display between temperature and resistivity. Typically resistivity should be greater than 8 M Ohm-cm. If it is too low let DI water run for no longer than 2 or 3 minutes. Our system has a single channel (measuring point) at the sink input so ignore channel 2. Press the bottom return/sil button if an alarm sounds. If alarm continues to sound, report problem to lab staff. Headcase nitrogen purge. This is not adjustable by sink users but should be reported to lab staff if flow is outside of indicated (mid-level) range. Magnehelic vacuum gauge. This gauge MUST be checked that the needle is in the acceptable range BEFORE each use of the fume hood. 6

6.0 SET UP AND OPERATION OF INDIVIDUAL CONTROLLERS AND MODULES The Modutek C1115a is used only to control the heated baths (A & F in Fig 1) in the acid wet bench. Refer to Fig 5 for the various control buttons. 6.1 Operation of Hot Bath Controller (Modutek C1115a) Fig 5 Heated Bath Controller 6.1.1 Setting up and using the bath: 1 Verify the drain valves are closed and that the bath is filled to the upper white region with the correct chemical: piranha or organic clean in bath A or inorganic clean (eg HCl/H2O2) in bath F (Fig 1). 2 Press and hold the "Power" key on the controller until the display light comes on. System comes up in the hold mode for safety reasons. 3 Press "Reset" key. System goes into normal mode unless there is an alarm condition. 4 If the stored temperature in memory is the desired temperature, the "Timer" key may be used to start the countdown, otherwise contact lab staff or superuser to make a change. 7

5 Pressing the "Timer" key a 2nd time freezes the count and a 3rd press restarts it. The timer will start alarming a programmable prewarning and will keep counting past the set time so that the total elapsed time is monitored. 6 Superuser may change the temperature by pressing "Prog". "CODE" flashes on the display. Enter the access code by using the arrow keys and press "Prog" again. NOTE: only superusers or lab staff can perform this operation. 7 Each time the "Prog" key is pressed, a different parameter is displayed: CS-clock setpoint (time duration), PA-prewarn offset, and PS-Process Setpoint (temperature). The arrow keys are used to change the value of each and the range for each is: CS Clock Setpoint 00:00 to 99:59 Min:Sec PA Prewarn Offset 00:00 to 00:59 Seconds PS Process Setpoint 00.00 to 199.9 Degress C Press "Prog" after each value change to go to the next parameter. CAUTION: There are 12 other parameters which MUST NOT be changed as they can cause system failure. 8 Press "Reset" to return to the normal mode 9 Do NOT use the Save key as this will make your changes the default changes. Lab staff will put the appropriate default values in the EEPROM. In this way if a mistake is made, turning the power on and off will call up the default values. 10 To drain the solution from the tank, make sure an empty waste bottle is under the spigot and that the solution is adequately cooled (usually below 40 C). Press Drain twice to open the valve. Go to the manual valve and slowly open it. After the bath is drained close the manual and controller drain immediately. 11 Fill out the log book after each use OR whenever changing the bath solution. 6.1.2 Additional keys and their use: HOLD Timer freezes and the heater is disabled VIEW Displays process setpoint and timer preset SAVE/SIL Save works in the Program mode and is to be used ONLY by staff In normal mode, it silences the alarm DRAIN Works in conjunction with the manual valve at left side of sink and opens drain up if solution is below preprogrammed dr setting. 6.1.3 Alarms: SYSTEM A system malfunction such as the EEPROM save routine. SENSOR An open circuit for thermocouple is detected, the heater is shut off and the display flashes "OP" for open sensor. H LIMIT A dangerous overtemperature condition is detected and the heater is shut down. L TEMP Low temperature alarm. LO flashes on the display. L LEVEL Low liquid level sensor. LL is flashed and the heater is turned off. 6.2 Operation of Timers (Modutek T16a) There are 3 stand-alone timers (C & D in Figs 2 & 3). All are Modutek T16a in the acid wet bench. Refer to Fig 6 below. 8

Fig 6 Stand Alone Timers 6.2.1 Using and setting up the timers. 1 Press "start" to begin the timer countdown. The pre-programmed time is shown in the display. The timer goes into the run mode and the display counts down. 2 To change the time, enter the program mode by holding the "Stop/Reset" key and pressing "Start". The program indicator light should come on. While in the Program mode the "start" key is used to toggle between the time and pre-alarm setpoints: CS Clock Set point 0:00 to 99:59 Min:Sec PA Pre-alarm 0:00 to 0:59 Seconds 3 Use the arrow keys to adjust the desired times for each function 4 Press "Reset" key to exit the program mode. 6.2.2 Additional timer features. The "start" key may be used as an audio silencer without stopping the timer. The pre-alarm sounds an audio tone with a 50/50 duty cycle for a second; the setpoint alarm is a continuous tone which also causes the display to flash. 6.3 Operation of Dump Rinse Controllers (Modutek C15) Dump rinsers J & L in Fig 1 are controlled by dump rinse controllers F & E in Figs 2 & 3 and its operation is described below (refer to Fig 7). 9

6.3.1 Keypad Operation Start- Activates the rinser for the number of pre-programmed cycles shown in the display. It continues running the system if it is in the HOLD mode. Stop/Reset- Puts system in HOLD if it is still running; resets controller if it is in Hold; exits program mode and resets controller in PROGRAM mode. Prog- 1st key press places system in PROGRAM mode. An access code is needed to proceed. Only trained authorized users are given this code. After entering access code, pressing 'Prog" will scroll through the various parameters. Arrow keys are used to increase or decrease the displayed parameter. Open- This key is used to manually dump the tank. Press the "Reset" key twice to force the dump door closed again. 6.3.2 Programming Programming will be done by the lab staff or appropriate superuser. Adjustments to fill or dump time and the number of cycles should be referred to the lab staff. NOTE: WHEN USING DUMP RINSERS VERIFY THAT THE WAFER AND CASSETTE ARE COMPLETELY COVERED BY WATER BEFORE WATER IS DUMPED. Fig 7 Modutek C15 Dump Rinse Controllers 10