Troubleshooting & faults guide

Similar documents
Simplex Panel Interface Guide

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Rev B, 9/2/2009. Kodiak Chiller Overview

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Ness acomms Install & User Manual

Alarm description DECS Contents

heat interface units A BOILER WITHOUT A FLAME

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

CBI-064. User Manual. Caddx to KNX-BUS Interface

Security Escort Central Console Software SE2000 Series

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

Addressable Fire Alarm Control System 2100 series

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

Quickheat 30 weather compensated boiler control

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Alarm description DECS Contents

SSIC INSTALLATION, OPERATION & MAINTENANCE MANUAL

Added password for IP setup page : Password must be in IP format!

Lighting Xpert Insight User Manual

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

1.1 Controller General Information

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Intelligent alarm management

Dryer Master DM510 Users Guide

Manage Alarms. Before You Begin CHAPTER

SEE DISCLAIMER ON REVERSE

Manage Alarms. Before You Begin CHAPTER

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

COMP201: Software Engineering I. Assignment 1, Part 2 (2017/2018) (100% mark for Assignment 1 is 10% of COMP201 grade)

MicroTech Unit Ventilator

Quick start guide. English

Manage Alarms. Before You Begin CHAPTER

Monitoring Software for NPBC-V3M-1 User Manual

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

Portable Dryer Touch Screen Controls

Touchpad Exit Controller Administration Guide

1U ULTRA Compact System

Operating instructions V-ZUG-Home

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Alarm Getting Started

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

PBI Manual. Paradox to KNX-BUS Interface

WOOD CHIP HEATING HPK-RA

Boztek Solutions` PLAYSTATE

Introduction to Modular Programming. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

DESCRIPTION OF KEYPAD (Access module with segments)

WOOD CHIP HEATING HPK-RA

Manage Alarms. Before You Begin CHAPTER

Ademco Vista Alarm Panel

V10 Controller - BACnet lnterface Supplement 1

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Version 1.03 January-2002 USER S MANUAL

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Building Automation solutions

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

Alarms for the Cisco ISA 3000

ProCon Boiler Controller Commissioning Quick Reference Guide

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Bosch TCU Integration Module Administrator's Guide

Peacock Salt. Multisol Pro VA Operation & Training Manual

CONTENTS. Page. Contents 1. Introduction, features and benefits 2. PART ONE Overview of the softening process 4-5

Lyric T6 & T6R Smart Thermostat

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

BGH Series Hot Surface Ignition Control

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Installation, Configuration and User Manual

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Important safety information

INSTALLATION AND OPERATION MANUAL

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0

CS027 User Instructions

Daikin ENVi Thermostat installation overview

Zoning Solutions. Thermostats & Wiring Centers Designed to Maximize Indoor Comfort. A Watts Water Technologies Company

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

User Guide. Sky Muster service. Includes information about your nbn supplied equipment

725B Configuration Software Manual

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Your partner for intelligent street light systems

Fire Operator Workstation (Fire OWS) User s Guide

EQ-ROBO Programming : Cliff Check Robot

Operating manual. Wascator FOM71 CLS

MG & SG SERIES BOILERS

C-Stat 17-ZW User Instructions

nbn setup guide Fibre to the Curb (FTTC) Connecting to the nbn broadband access network 1

PROFIRE BMS Controller

Spectrolink Comfort Control. Home Owner's Manual Heating

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

DOMESTIC HOT WATER Follow operational sequence

Operation & Maintenance Manual

Transcription:

Troubleshooting & faults guide www.minibems.com

2 www.minibems.com Content Introduction 3 Internet goes down 4 Local area network fails 4 Sensors fail 4 Troubleshooting 5 Contact 7 Minibems is a registered trademark of Minibems Ltd.

3 www.minibems.com Introduction The Minibems solution is an intelligent control and monitoring system. Minibems allows communication across a complex heating network to provide the most efficient method for delivering heat. It also provides the capability to monitor a complex installation from anywhere in the world. The purpose of this manual is to provide an overview of the Minibems product and a guide to installation, operation and fault finding.

4 www.minibems.com What happens when things go wrong? The Minibems control system is designed to provide the most efficient heating possible. In order to deliver this it requires a lot of information from sensors and other units; this intercommunication is what makes Minibems so powerful. Iif this complex system fails, the system must continue to perform at least as well as a simple system. This section details the possible failure scenarios and what you should expect the system to do in these instances. Internet Goes Down This won t affect the system s performance or efficiency. The real time data will not be available via the internet and you won t be able to make any changes to your system on your computer, tablet or phone. The heating and hot water will continue to work as normal. Local Area Network Fails In this case, much of the Minibems intelligent control cannot work as it relies on communication between all the boards. However, the system will continue to work at least as well as a simple control system. The network export will revert to a fall back temperature of 70 C. Heat exchangers will open the control valves on the primary side and assume heat will arrive, then they will modulate, delivering heat to heating circuits as normal. Sensors Fail If the controller requires a particular sensor to function, such as a room sensor in a heating circuit, the controller will stop running. The status light on the box will go red, and the error will be reported via the UI. As this will mean that heat is no longer being delivered, the sensor will need to be fixed. If the sensor is only required for monitoring, the system will continue to run normally. A warning will displayed via the UI.

5 www.minibems.com Troubleshooting 1 Heating circuit has no heat Check the status light on board, if this shows red, go to section 5. If is showsyellow, go to section 6. Check the room control unit if fitted. Is the room shown as occupied? Check the last change message in the controller diagnostics. This should read On - in schedule period (21.00C) or similar. Act on message if different. Check the producer (i.e heat network export). If this is not hot, check the producer upstream. 2 Biomass boiler has not fired Check the device diagnostics and boiler Modbus data. Make sure no boiler errors are displayed. If you are unsure whether the boiler is ignited, check the O 2 content on the chart. A reading of 7-15% means there is a fire. 3 Heat interface unit not delivering heat to heat interface unit Is the primary flow temperature similar to, or lower than, the primary return temp? - Check that the flushing bypass is not open. Is the primary flow control valve open, but minimal heat is being delivered to the secondary side of plate? - Check the line strainers on the primary side of plate. - Check the plumbing is the heat main flow plumbed to the HIU primary return? 4 Hot water cylinder is too hot Check the flow control valve for the cylinder. If lights are flashing the valve is in error state - this may indicate thatthe valve is stuck open due to a blockage

6 www.minibems.com Troubleshooting 5 Orange/yellow status light This light indicates that the process is not running. Try pushing the configuration form the UI using the Generate Config button. If this fails, use the WSS-monitor send commands tool, clear the settings.json and configuration.json files to reboot the board. You can find further details in the WSS-monitor remote commands library. 6 Red status light This light indicates that the main process is running but there is an error. Check the device diagnostics devices in error will be highlighted red. Check the cabling, settings and voltage levels are as described in the hardware guide 7 No lights at all Look through the network port, you should see a blue light which may be flashing. If the light is not visible, check the power supply. If the blue light is on, check to see if the board is visible via the WSS-monitor, and try updating the Minibems software. If the board is not visible on WSS-monitor, try power cycling the board, (turn off, wait 30 seconds, turn on). The light should illuminate after a maximum of 5 minutes. If the above fails, you may need to change the board.

Contact Technical support - +44 (0)1392 249 110 support@zerocarbonfuture.com www.minibems.com