EFFISUS BRAZE MEMBRANE

Similar documents
Firestone GeoGard EPDM Review of Technical Performances

Firestone EPDM Geomembrane Review of technical performances

Leadax B.V. Covenant K93792/02. Leadax

Firestone Lining Systems. Dependable Performance in Demanding Environments

RG1,5SA Self Adhesive

FLAGON PVC FLAGON SV ROOFING SYNTHETIC MEMBRANES

SPIDER P SPIDER P mineral

Rhepanol hg. For more information on SIG Design & Technology visit A solid foundation for green roofs.

Geomembranes that work

Geomembranes that work

FIRST-CLASS IN TRAINS

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

FAÇADE FIRE TESTS Towards a new European standard method

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

3th International Conference in Warsaw "MODERN TRENDS OF FIRE PROTECTION IN ROLLING STOCK"

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Test Report: ICL/CR15/11/087

Technical Sheet. Hybrid concealed radiator System Insulated Rubber Pipe

The Laboratory is qualified to update standards identifying the test procedures.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Welcome to the world of EPDM roofing systems

Annex of the certificate (Page 1/5) Accreditation Scope

The Laboratory is qualified to update standards identifying the test procedures. Test procedure/ method identification

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

Table of contents. Introduction Design. 2. Installation. Attachments

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

Annex of the certificate (Page 1/7) Accreditation Scope

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Contents EN :2006+A2:2016 (E)

The Laboratory is qualified to update standards identifying the test procedures.

Q-Air evaluation by experiment

Firetect C. Fire protective products: Fire protective board

PRODUCT DATA SHEET (ver.04/ )

Scope of accreditation

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

STUDY ON THE REACTION TO FIRE OF MEDIUM VOLTAGE CABLES SYSTEMS

Contact person Date Reference Page Richard Johansson P (2) Fire Research

HRS Hand Rail System 1

STS Directory Accreditation number: STS 0030

ISO INTERNATIONAL STANDARD. Fluid power systems O-rings Part 5: Suitability of elastomeric materials for industrial applications

STS Directory Accreditation number: STS 0329

FLEXIBLE NON-METALLIC COVERING FOR INDUSTRIAL INSULATION. Specially developed for use in offshore and industrial environments

Development of a European approach to assess the fire performance of facades

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CLASSIFICATION REPORT

Classification report

Urban Drainage Geomembrane (UDG)

DRESS YOUR POOL IN COLOR WITH TEXPOOL TEXPOOL NG 11. Reinforced 1.5 mm waterproofing membrane, for that touch of elegance

European Technical Assessment ETA-14/0176

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Coatings for protection of FRP structures with heavy rain erosion loads

Engineering Specifications

TFI Report Classification

STOURFLEX. Technically Advanced Flexible Solutions. A Guide to the Selection of STOURFLEX Pump Connectors

CI/SfB. September MediCare range. MediCare Standard. MediCare Plus. MediCare Air

An Introduction to Soil Stabilization for Pavements

For more structural safety

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

For more structural safety

This document is a preview generated by EVS

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Wires, Cables, Cords and Adhesive Tapes

Centrum stavebního inženýrství a.s.

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

0014-L-16/1 2 March Test report. EPDM Quickgoot system

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

List of tests (2018)

CR A-F-A-E-HQQE 3x400/ HZ

Latin American Coatings Show 2017 WACKER Presents Silicones and Polymer Binders for High-Quality Paint and Coating Applications

SGG CONTRAFLAM LITE SAINT-GOBAIN GLASS PROTECT

CAPPING OF A GOLD MINE IN ROSIA MONTANA, ROMANIA

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Smoke extraction duct of sheet steel

ARIES. 3,9mín 0,5 ( ph < 4)

Visqueen Vapour Control Tapes

Centrum stavebního inženýrství a.s.

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CERTIFICATE OF APPROVAL No ME 5085

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

DUOPEX WATER MANUAL mm

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

KQ July 1, Evaluation Guideline

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Schueco Fire and Smoke Protection Systems

MAXI-VENT Air Admittance Valve

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Transcription:

Effisus Braze Membrane EFFISUS BRAZE MEMBRANE Elastomer sheets for facade sealing from Ethylen-Propylen-Dien-Terpolymer (EPDM), homogeneous, cured without fleece-backing. Elastomer sheets for facade waterproofing. Technical data Test Method Unit Value of result Fire Reaction (Building Facade ) EN 13501-1 - Class B, s1, d0 Pass Test Report: RI 63/LFF/10 of 25/09/2010 SBI Fire Tests of examination on the reaction to fire of facade prototype with Effisus Braze Membrane, glass and aluminium, in accordance with EN ISO 11925-2 and EN 13823, with direct flame exposure time of 1254s. Fig. 1 SBI Fire Test The material classification is in accordance with EN 13501-1:2009. It was verified a very limited contribuition to fire conflagration (B class ), a minimum smoke production (s1) and no flaming droplets/ particles (d0). Test Method Fire behaviour Smoke Production Flaming droplets B - S 1, d 0 Test Report RI 63/LFF/10 of 25/09/2010 1/2

Effisus Braze Membrane Watertightness EN 1928 (B) Passed MLV Joint peel resistance EN 12316-2 N/50mm 190 MLV Joint shear resistance EN 12317-2 N/50mm 250 MLV Tensile strength EN 12311-2 N/mm2 6 MLV Dimensional stability EN 1107-2 % 0.5 MLV Foldability at low temperature EN 495-5 ºC -40 MLV UV exposure EN 1297 - Passed Passed Water vapour properties µ EN 1931-90.000 30% MDV Reaction to fire EN 13501-1 - Class E Passed Ozon resistance EN 1844 - Passed Passed Exposure to bitumen EN 1548 - Passed Passed Total thickness Efective thickness Stand 02/11 V 1.1 AT 22/07/2011

Effisus Braze SA-Edge Membrane Standard DIN EN 13956 EFFISUS BRAZE SA-EDGE MEMBRANE Elastomer sheets for facade sealing from Ethylen-ropylen-Dien-Terpolymer (EPDM), homogeneous, cured, with self adhesive backing. Sheets for adhered or mechanically fastened facades. Total thickness: 2,0mm. Efective thickness: 1,2mm. Watertightness EN 1928 (B) - Passed MLV Joint peel resistance EN 12316-2 N/50 mm 50 MLV Joint shear resistance EN 12317-2 N/50 mm 175 MLV Tensile strength EN 12311-2 N/mm² 6 MLV Dimensional stability EN 1107-2 % 0,5 MLV Foldability at low temperature EN 495-5 ºC -40 MLV UV exposure EN 1297 - Passed Fulfilled Water vapour properties µ EN 1931-90.000 ± 30% MDV Reaction to fire EN 13501-1 - Class E Fulfilled Ozon resistance EN 1844 - Passed Fulfilled Exposure to bitumen EN 1548 - Passed Fulfilled Stand 02/09 V 1.1 AT 22/07/2011

Effisus Braze P-Fix Membrane EFFISUS BRAZE P-FIX MEMBRANE Elastomer sheets for facade sealing from Ethylen-Propylen-Dien-Terpolymer (EPDM), homogeneous, cured without fleece-backing with a EPDM clip-in profile for installation in receiveing slots without the use of adhesive or sealing material. Elastomer sheets for facade waterproofing. Technical data Test Method Unit Value of result Fire Reaction (Building Facade ) EN 13501-1 - Class B, s1, d0 Pass Test Report: RI 63/LFF/10 of 25/09/2010 SBI Fire Tests of examination on the reaction to fire of facade prototype with Effisus Braze Membrane, glass and aluminium, in accordance with EN ISO 11925-2 and EN 13823, with direct flame exposure time of 1254s. Fig. 1 SBI Fire Test The material classification is in accordance with EN 13501-1:2009. It was verified a very limited contribuition to fire conflagration (B class ), a minimum smoke production (s1) and no flaming droplets/ particles (d0). Test Method Fire behaviour Smoke Production Flaming droplets B - S 1, d 0 Test Report RI 63/LFF/10 of 25/09/2010 1/2

Effisus Braze P-Fix Membrane Watertightness EN 1928 (B) Passed MLV Joint peel resistance EN 12316-2 N/50mm 190 MLV Joint shear resistance EN 12317-2 N/50mm 250 MLV Tensile strength EN 12311-2 N/mm2 6 MLV Dimensional stability EN 1107-2 % 0.5 MLV Foldability at low temperature EN 495-5 ºC -40 MLV UV exposure EN 1297 - Passed Passed Water vapour properties µ EN 1931-90.000 30% MDV Reaction to fire EN 13501-1 - Class E Passed Ozon resistance EN 1844 - Passed Passed Exposure to bitumen EN 1548 - Passed Passed Total thickness Efective thickness Stand 02/11 V 1.1 AT 07/01/2013