PREPARED BY: Jeff Geraci, Environmental Scientist I. REVISED BY: Kristina Davis, Environmental Scientist III

Similar documents
HydroFlux Welder Torch System T0-102 / T0-103

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

STANDARD OPERATING PROCEDURE EQUIPMENT DECONTAMINATION PROCEDURES

CMU701/ 705 OPERATIONS & INSTRUCTION MANUAL

PFS SERIES. Foot Impulse Stamping Sealers. Operational Manual PFS-350 PFS-450 PFS-650

Centrifuge STANDARD OPERATING PROCEDURE

Fleck 7000 Sediment Filter Installation & Start-Up Guide

FL-1000 FLEC Air Control

Clean Water Made Easy

7800 Neutralizer Installation & Start-Up Guide

C Y T O - T H E R M III T

IQ/OQ Protocol Installation Qualification/ Operation Qualification

Set-up/Operating Manual for Model X5-CD

Fleck 2510 SXT Catalox Installation & Start Up Guide

Multi-Mode Electrode pro

Smart Water Heater Controller

DAVIS PACKAGING. TD-362 Dual Roll Console Reference Guide.

Dr. Infrared Heater Elite Series

Teaching Lab Headway Spinner SOP

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

Service Manual. Model Number: DWOP20R. UL Part Number

Clean Water Made Easy

26/06/2018 USER MANUAL OSMOSE HOBBY GPH. All rights reserved Les Équipements d Érablière CDL inc.

EcoSmart Troubleshooting Guide

Operating Instructions

Tap Master Artesian Hydro Gardener Series Installation & Service Manual

Laboratory Glassware Cleaning and Storage

Installation Instructions

Start the cleaning from Left and finish at Right. Always do the floor last, start from inside and finish at doors

5900e Neutralizer Installation & Start Up Guide

26/06/2018 USER MANUAL HOBBY 100 GPH REVERSE OSMOSIS. All Rights reserved Les Équipements d Érablière CDL inc.

Infrared Portable Space Heater

Centrifuge STANDARD OPERATING PROCEDURE

Rules for Safe Operation

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Fleck 5600 Carbon Filter Installation & Start Up Guide

5700-E Sediment Filter Installation & Start-Up Guide

Title: Glassware Cleaning Copy No: ## SOP No.: 3.02/2.6/S Effective Date: June 18, 2013 Location: ### Glassware Cleaning

CytoTherm-DR Plasma Thawing with Rocking Action

Super Elite Watch cleaning machine

Cleaning Procedures in ICP-MS Laboratories

phd Countertop UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized

KFC Delivery System. Vesture's DC System

EQUIPMENT CLEANING Indira Pindi Watershed Monitoring September 20, 2017

Heater for BRP Commander. Caution: Before using this product, read this manual and follow all safety instructions. Owner s Manual

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

INSTRUCTION MANUAL HAND MIXER 300

Quick start guide for Altrix Precision Temperature Management System

Electric Decoral (Thermalist) Radiators

MF90 Series Portable Filters (CE)

CER-1 & CER-2 Installation & Testing Instructions

Fleck 5600 SXT. Installation Guide. Make a list of all of the plumbing fittings needed to install; a typical list looks like this:

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

7500-S Sediment Backwash Filter Guide

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

MODEL 7000 SUCTION UNIT

Direct Heat Foot Sealers Models: W-220DT(S), W-300DT(S), W-450DT(S) Distributed By:

Parts & Material Included

Liftoff/Strip Solvent Bench SOP

Page: Page 1 of 9 Author: Kristin Smith MAL Director: Dr. Peggy Borum FSHN Chair: Dr. Neil Shay

LEAK DETECTION KIT. Your Leak Detection Kit should include the following items:

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Eccotemp L5 and L10 Comprehensive Troubleshooting Guide

PERFORM Operating Document

User Instructions. Visit us at us at RB5, RB10, RB15 Maple Sap Buckets

Water Softener Installation Guide Effective for all Softeners from our Range

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

Setup. Important. Texture Spraying (material supplied from unit)

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

14 Upright Vacuum with HEPA Filter & Dual Power

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

1/2011 V1. Puzer AINO USER MANUAL. Read this instruction before using the vacuum cleaner! Keep the instructions near the vacuum cleaner for later use!

M770 ph Controller Owner s Manual

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

PORTABLE AIR CONDITIONER MODEL NO: AC9000

SQUEEZEBOX PRESS OWNER S MANUAL

Clean Water Made Easy

Manual Parts Washer. Operating Instructions & Warranty Information

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

OPERATING AND MAINTENANCE MANUAL

O p e r a t i n g I n s t r u c t i o n s

VAC-THEN-STEAM MV2010UKL OWNER S GUIDE

Endoscope Reprocessor Installation Instructions Endoscope Reprocessing System

OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION

Operating Instructions

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

Infrared Portable Space Heater

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

AquaLiv Water System - Usage & Installation Instructions

SERVICE & TROUBLESHOOTING MANUAL FOR DISPLAY HOLD CABINETS DHC SERIES

1. WARNINGS FOR YOUR SAFETY 2. TECHNICAL SPECIFICATIONS. Allowable Ambient Temperatures: Maximum Film Quantities: 3. INTRODUCTION

Electric Cast Iron Radiators

Aasta Hansteen Topside EPC Project. 1 Accepted. Date : 20/08/2015. Issued for Construction. D.Y.Kang D.Y.Kang. Issued for Review.

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Sx-280. Squeezebox press California Road, Orchard Park, NY USA Fax:

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

Transcription:

DOCUMENT TYPE: TITLE: Standard Operating Procedure Redi-Flo Performance Pumps PREPARED BY: Jeff Geraci, Environmental Scientist I REVISED BY: Kristina Davis, Environmental Scientist III REVIEWED BY: Jan Kilduff, Environmental Scientist V APPROVED BY: Marshall K. Cheung, Ph.D., Laboratory Director Table of Contents 1. Scope and Application...5 2. Summary of Method...5 3. Equipment...5 4. Operating Conditions...6 5. Reagents...6 6. Procedure...6 7. Bibliography...8 Page 1 of 8

Page 2 of 8

Document No.: SP 0004 001 Copy provided to: Marshall K. Cheung Title: Laboratory Director 29 Palms Laboratory 47-250 Dillon Road Coachella, CA 92236 Copy provided by: Alison Millar Title: Environmental Technician II Date: July 28, 2004 Page 3 of 8

Page 4 of 8

1. Scope and Application 1.1. This procedure is to be followed when operating the Redi-Flo Variable Performance Pump. 2. Summary of Method 2.1. Start generator (See SOP #SP007 Generac EXL Generator Operation). 2.2. Connect Redi-Flo Variable Frequency Drive (RF-VFD) to pump and generator 2.3. Insert pump into water for cleaning in following order. 2.3.1. Distilled water (TDS less than 5 mg/l=acceptable) 2.3.2. Reagent water (TDS less than 2 mg/l=acceptable) 2.4. Start pump, RSR switch to Run, at slow rate and slowly increase pump rate. 2.5. Collect equipment blank samples 2.6. Stop pump by switching RSR switch to stop. 2.7. Repeat 2.1-2.2 at sampling site. 2.8. Insert pump into monitoring well for sampling. 2.9. Start pump for sampling. 2.10. Stop pump 2.11. Insert pump into tap water for cleaning before storing. 2.12. Start pump 2.13. Stop pump 3. Equipment 3.1. Redi-Flo 2 Variable Performance Pump (RF2) 3.2. Motor lead (tubing and spool) 3.3. Discharge hose 3.4. Redi-Flo Variable Frequency Drive (RF-VFD) 3.5. Redi-Flo Pump Logbook 3.6. Generac EXL Generator 3.7. 55 gallon drum 3.8. Two (2) pipette baskets (a little under 5 gallons) 3.9. Cleaning rags 3.10. Tool box 3.10.1. 2 ten inch wrenches 3.10.2. Stop watch or timer 3.10.3. Scissors 3.10.4. Plumbers/Teflon tape 3.10.5. Plastic bags 3.10.5.1. 1 for garbage, 3.10.5.2. 1 to cover pump after sampling and cleaning. 3.10.6. Plastic-tie to secure bag around pump head after use. 3.10.7. Pinch pliers to remove ring in pump head if necessary while cleaning. 3.10.8. Alternative power source for Volt meter, either batteries or AC adapter 3.10.9. Power surge protector 3.10.10. Volt meter Page 5 of 8

4. Operating Conditions 4.1. The RF2 pump must be installed vertically with the discharge end pointed upwards. 4.2. The electrical voltage supply to the RF-VFD must always be between 103 and 126 VAC from 120v outlet (See SOP #SP007 Generac EXL Generator Operation). 4.3. The pump and motor must always be completely submerged in fluid to ensure lubrication and cooling of the motor. 4.4. Ensure that the pump remains at least 3 feet below the well water level through frequent depth sounding at the beginning of well purge (See SOP #SP006 Static Water Level Determination). Never let the pump run dry! 4.5. The pump is not recommended for continuous operation applications. 4.6. When the pump is used to purge wells, start the pump at minimum speed and then gradually increase to the desired speed. 4.7. Do not stop the pump until the pumped fluid contains no visible particles (to avoid blockage within the pump). 5. Reagents 5.1. Tap water (40 gallons) 5.2. Distilled water (Bottled) (5 gallons) 5.3. Reagent water (deionized/nanopure water) (5 gallons) 5.4. 500 ml squirt bottle of reagent water 6. Procedure 6.1. Start pump 6.1.1. Start the generator and allow it to warm up (See SOP # SP007 Generac EXL Generator Operation). 6.1.2. Plug the RF-FD into the power surge protector that is plugged into generator. 6.1.3. Select RF2M with the mode selection knob. 6.1.4. Connect the motor lead to RF-VFD. 6.1.5. The Frequency Display on the RF-VFD should read 0.0. 6.1.5.1. If not, refer to Troubleshooting, pp 19-20 in manual. 6.1.5.2. Let the RF-VFD stay on for 5 minutes before starting pump 6.1.6. Submerge pump (RF2) must be placed in water source at least 3 feet below water level. 6.1.6.1. If pre-sampling cleaning refer to section 6.3. 6.1.6.2. If purging or sampling then refer to SOP SP 002 version 1.3. 6.1.6.3. If post sampling cleaning refer to section 6.7. 6.1.7. Switch RSR switch to Run. 6.1.8. Turn the speed dial (10-turn potentiometer) slowly at first until the desired performance is attained (200 Hz = 2 gallons/minute for cleaning pump). 6.1.9. Perform procedures 6.1.9.1. If pre-sampling cleaning refer to section 6.3. 6.1.9.2. If purging or sampling then refer to SOP SP 002 version 1.3. 6.2. Stop pump 6.2.1. Turn speed dial all the way down until it reaches 25 Hz 6.2.2. Switch RSR switch to Stop Page 6 of 8

6.2.3. Unplug the RF-VFD from the generator BEFORE removing the motor lead from the RF- VFD or turning off the generator. 6.2.4. Wipe down RF-VFD and put away. 6.3. Pre-sampling pump cleaning 6.3.1. Place pump in clean pipette basket and fill to top with distilled water (about 5 gallons). 6.3.2. Turn pump on according to 6.1 and again pump at 200 Hz (2 gallons/min), allowing the first gallon pumped to exit the basket and then allowing the remaining 4 gallons to recirculate through pump, hose, and basket for 15 minutes. 6.3.2.1. Take a sample every 5 minutes to test for conductivity and TDS. 6.3.2.1.1. If TDS is less than 5 mg/l then proceed with next step, otherwise repeat 6.3.5. with fresh distilled water (< 5mg/l = acceptable). Record results in Conductivity Log. 6.3.3. Turn pump off (Section 6.2). 6.3.4. Place pump in clean pipette basket and fill with 5 gallons of deionized water. 6.3.5. Start pump according to section 6.1 and pump rate to 200 Hz or 2 gallons/minute. 6.3.6. Check temperature, conductivity and TDS every 5 minutes for 15 minutes. Record results in Conductivity Log. 6.3.6.1. If after 15 minutes the TDS is not less than 2mg/l then repeat 6.3.8 with new deionized water. 6.3.7. Turn pump off (Section 6.2). 6.3.8. Use remaining distilled and deionized water from steps 6.3.5 and 6.3.8 to rinse hose and hose reel. 6.3.9. Gently clean RF-VFD housing and case with damp rag. 6.4. Purging monitoring well and Sampling 6.4.1. Place pump at desired depth 6.4.2. Refer to section 6.1 for starting pump operation 6.4.3. Purge well at high speed. 6.4.4. Sample monitoring well at low speed. 6.4.5. Section 6.2 for turning off pump 6.4.6. Cover pump with plastic bag and tie to protect clean pump head. 6.5. Post sampling pump cleaning back at office 6.5.1. Set pump in clean 55-gallon drum filled with clean tap water. 6.5.2. Start pump according to section 6.1 and run at an approximate 2 gallons per minute rate (RF-VFD setting of 200 Hz). 6.5.3. Pump tap water to ground or recycle it back into drum for 15 minutes. 6.5.3.1. Take sample every 5 minutes and test for conductivity and TDS, record in Conductivity log (SOP # PP002) 6.5.4. Turn off pump (Section 6.2) 6.5.5. Dissemble pump motor head for cleaning. 6.5.5.1. Use pinch ring pliers to remove ring inside top of casing. 6.5.5.2. Use ten-inch wrench to remove from encasing 6.5.5.3. Use ten-inch wrench to remove tubing from pump. 6.5.5.4. Clean all items with rag and water 6.5.6. Assemble pump to lead to reuse again 6.5.6.1. Wrap screws with Teflon tape before assembling. Page 7 of 8

6.5.6.2. insert diagram** 6.5.7. Cover pump with plastic bag and tie up for storage in sample receiving room. 6.5.8. Gently clean RF-VFD housing and case with damp rag. 7. Bibliography 7.1. Redi-Flo Variable Performance Pump Installation and Operation Instruction Manual. Customer service center: phone (800) 333-1366; fax (800) 333-1363. Page 8 of 8