TOUCHSTONE Dual Variable Speed System. Installation & Operating Manual with Troubleshooting and Configuration Guide

Similar documents
THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Typical Installation Breaker Box Class A 50 amp, 120/240 volt, GFCI

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

AIR MASSAGE KIT INSTALLATION INSTRUCTIONS

ELLA HYDRO MASSAGE OUTWARD SWING DOOR WALK IN BATHS OWNERS MANUAL

U-CLASS SPA SYSTEMS. Dealer TechBook by Gecko Alliance. Technical Specifications, Programming, Installation & User's Instructions!

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Manifold Installation Controller MIC-180. Installation and Operation Instructions

16 OUTDOOR MISTING FAN

Warming Drawer Installation Guide

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

ELLA HYDRO MASSAGE WALK IN BATHS OWNERS MANUAL

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

ignored. Denotes content that may result in bodily injury and physical damage when ignored.

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Medical Equipment Washer Information & Setup

Diamond Whirlpool/Air pool INSTALLATION & OPERATION INSTRUCTION

Installation and Operation Manual MG-304. Please read this manual carefully before use.

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Important safety instructions

1-866-PENNERS

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

COLONY COLLECTION OWNER S MANUAL. For your installation, operation, and maintenance needs. Whirlpools Air Baths Combo Baths Soakers

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Premier Hazard STC Instructions

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

Downdraft Ventilation

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

L A signature series TA T N E RE O, A L L A T S IN

Factory Direct Walk-In Tubs WALK-IN TUB. Installation Manual. For Model Numbers VT2848, VT2853, VT3153 and VT3255

Access Tubs. Installation & operating instructions COSTCO MODEL # / RIGHT COSTCO MODEL # / LEFT

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Smart-Wall TV Kit - Installation & Operation Instructions -

AQ-4000 Series Information & Setup

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Installation & Operating Guide

Access Tubs 3238 DUAL ( AIR/HYDRO ) INSTALLATION & OPERATING INSTRUCTIONS MODEL INSTALLATION & OPERATING INSTRUCTIONS. Costco Item # /394831

Manuel Guide Lighting Fixtures

OWNER MANUAL PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE

Gen II Entree Bath - All Models

Access Tubs. Installation & operating instructions. Costco Item # /394831

OWNER MANUAL PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE

BLOWER ACCESSORY MODEL #FIB100 Español p. 17

STORM. Bottom-Load. Water Dispenser User Manual

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

RELAX. REVITALIZE. RESTORE. LUXURY SPA UNIT Installation Manual. English. For Model Numbers 2848, 2853, 3153 and 3255

Electric Fireplace Instruction Manual

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

UNIVERSAL TEE STYLE Hydromassage Bath Heater INSTALLATION INSTRUCTIONS

Model K 520 M Part No

Whirlpool Bathtub Model Number: MT618

DEHUMIDIFIER INSTRUCTION MANUAL

MARINE FAN COILS INSTALLATION MANUAL

Motion Sensor Oscillating Heater with Digital Control

ELECTRIC FIREPLACE OWNER S MANUAL

40 Built-in Electric Fireplace Operating and Installation Instructions

30 Misting/Oscillating Fan Model Number 01030

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

Installation, Operating, and Service Manual. Badu. EcoM3. Swimming Pool Pump

LEVENS STEAM SHOWER ENCLOSURE

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

K 3.97 M. Specifications or visit our website: In USA call: Part No

OWNER MANUAL. Mini Lavender

OPERATING INSTRUCTIONS. Dedicated Holding Bin DHB2-20CE & GB Series ELECTRICAL SPECIFICATIONS

Page 1 of 18. Part# /5/2013

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

EVAPORATIVE COOLER W

Installation & operating instructions

Manual update 2016 MC37/MFC3600

Mobile Evaporative Cooler. Use & Care Guide MC37 / MC61 INDEX

Menumaster. Commercial Microwave Oven Use and Care Manual FS-8EVP FS-11EVP FS-16EVP

OPERATOR S MODEL MPC-21L MPC-222 MULTIPURPOSE PASS-THRU HOLDING CABINET. Read instructions before operating the appliance

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

Instruction Manual. Bucket Oil Pump

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

WL380 QUICK START GUIDE

Advantage Series Bathing System Specifications

Model gffoz Process Ozone Sensor (In-Line)

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Ducted air conditioner Operating Manual

1020 Industrial Drive, Orlinda, TN fax

INSTALLER: Save these instructions. for owner. owner s + operator s. manual

MP BB. ElEcTrIc FIrEplAcE HEATEr. INSTrUcTION MANUAl ATTENTION:

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Transcription:

TOUCHSTONE Dual Variable Speed System CIDU-315-03-02-01 Configuration #1 Dual Variable Speed Pump/Blower Configuration #2 Variable Speed Pump Configuration #3 Variable Speed Blower Installation & Operating Manual with Troubleshooting and Configuration Guide NuWhirl Systems Corp www.nuwhirl.com 951-817-5600 MAN315030201 REV A 4/10/2017 Page 1

Important Safety Instructions PLEASE READ CAREFULLY PRIOR TO Troubleshooting and Servicing Electrical Equipment Definitions: WARNING (May cause serious injuries or death) CAUTION (May cause property damage) For information on NuWhirl Instructions, see: www.nuwhirl.com/docs/product-instructions.html When installing and using this electrical equipment, basic safety precautions should always be followed, including: WARNING: Keep dry. Replace control if exposed to water, moisture or contamination. WARNING: Use and follow these instructions along with all instructions that have been provided with your whirlpool bathtub in order to fully enjoy the bathtub safely. WARNING: Electronic control system components should be installed as per local and national Electrical Codes, in a location not to be subjected to splashing or flooding. Exposure to water or splashing will void all product certifications and warranties. There are no user serviceable parts inside. Opening, modifying, or tampering with control system components will void all product certifications and warranties. WARNING: Risk of electric shock. Connect only to a ground type receptacle or power supply junction box protected by a Ground -Fault Circuit Interrupter (GFCI). Contact a qualified electrician if you cannot verify that the power supply is protected by a GFCI. The GFCI should be tested on a routine basis. Consult the GFCI manufacturer s instructions for correct testing and operation. Page 2 For electrical connections, see applicable wiring diagram. See www.nuwhirl.com/docs/productinstructions.html Do not use an extension cord to connect the product to the electric supply; provide a properly located receptacle or junction box. WARNING: Failure to install in strict accordance with each and every instruction above may compromise the system, which may cause injury to persons and/or property. The tub may be supplied from more than one power source. Before working on any electrical device, make sure all power to the control system is off. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. Any improper installation or misuse of the equipment may result in injury to the user and will void the warranty. Do not run unit dry. Always be certain that the pump casing is filled with water before starting the unit. If pump fails to prime within 30 seconds, turn it off. Check if there is an airlock, clogged plumbing, or closed valve. Save these instructions.

TOUCHSTONE Variable Speed Bath System Installation & Operating Manual Table of Contents Software Configuration..... P.4 Configuration 1 Pump/Blower Installation & Operations..... P.5 Configuration 2 Pump Installation & Operations..... P.7 Configuration 3 Blower Installation & Operations... P.9 System Troubleshooting..... P.11 All Installation Procedures in this manual are for use by Tub Manufacturers or Qualified Service Personnel ONLY. Page 3

Control Configuration Selection and Setting Guide This only needs to be performed on a newlyserviced system, or when the Keypad is replaced. The location of the Service Button is the Water Jet key shown above outlined in red (the appearance of your keypad may differ). After Power-Up, when this Service Button lights up, press and hold it until it begins displaying the Software number SFT-383 Rev A. The display will then show C01, and the Blower and + keys will light up (shown in blue circles). Pressing the Blower key will increase the Configuration Number, and the Speed + will decrease it. Once the Configuration Number is set to the required value, press and release the Service Button (red circle). The configuration number will now be permanently stored in memory. The keypad is now ready for use. The keypad is capable of being programmed to support various system configurations, features and options. These are the configurations currently available, as of April 2017: CIMC-315-03-02-01 Dual Variable Speed Pump/Blower Config #1: Electronic Keypad, Independent Timers, 10-Speed Blower, 10-Speed Pump, Multi-Color LED Tub Lights, Capacitive Water Detect. CIMC-315-03-02-01 Variable Speed Pump Config #2: Electronic Keypad, Independent Timers, 10-Speed Pump, Multi-Color LED Tub Lights, Capacitive Water Detect. CIMC-315-03-02-01 Variable Speed Blower Config #3: Electronic Keypad, Independent Timers, 10-Speed Blower, Multi-Color LED Tub Lights, Capacitive Water Detect. Page 4

TOUCHSTONE Variable Speed Bath System Installation & Operating Manual Dual Variable Speed Pump/Blower Configuration #1 System Identification: CIDU-315-03-02-01 Configuration #1 Dual Variable Speed Pump/Blower System features: Electronic Keypad, Independent Timers, 10- Speed Blower, 10-Speed Pump, Multi-Color LED Tub Lights, Capacitive Water Detect. Controller Installation: TO BLOWER Max 15 AMPS Load To 120V 15A GFCI Protected Receptacles TO PUMP 13.5 Amp Motor Nameplate Max CITW-209 CICL-297 CCBL 366 Female Cord Male Cords CILA-301 CCBL 168 CIDU-315 03-02-01 CIAU-214-01-03-01 CIMC-288-01-03-01 NOTES: 1. Use wire clips provided to retain cables. 2. CAUTION: Do not plug 8-pin cables into 6-pin ports or damage may result to system. 3. Connect cables to ports as shown. 4. Before assembling the two controllers together, remove the Blue Communication Window Plugs between them, and replace them with the supplied Clear Red Window Plugs for IR communication to occur between units. CIAU Unit is to be installed on the left of the CIMC unit as shown. CAUTION: Failure to connect cables to ports as shown, may damage the control box and its components. Pump Jets Blower Speed+ Tub Light Operation: When the Controller detects that there is sufficient water in the tub, all the buttons will light dim, and the Bath Temperature will display. Pump Wave Blower Wave Speed- User Set Page 5

Dual Variable Speed Pump/Blower Configuration #1 (continued) Pump Jets: Press and release the Pump Jets Button to turn it On. This Activates (brightens) the Pump Jets button, turns on the Pump at mid-level speed 5, and sets its 20 minute timer. The Speed+ and Speed buttons also Activate (brighten). To adjust the intensity of the Pump Jets: 1. Check that the Pump Button is Active (bright). 2. Press and hold the Speed+ or Speed- Button to slowly increase or decrease the respective speed (ranging from S10 to S1) until the desired intensity is reached. Press and release the Speed+ or Speed- Button to increase or decrease the respective intensity by one full speed. 3. Press the Pump Wave Mode Button to have it oscillate between the highest and lowest speeds. Pressing it again will cancel Wave Mode, and revert to Speed Mode. To turn the Pump Jets off: 1. Check that the Pump Button is Active (bright). 2. Press and release the Pump Jets Button again and the Pump will turn off, and the associated Buttons will De-Activate (dim). Blower: Press and release the Blower Button to turn it On. This Activates (brightens) the Blower button, turns on the Blower at mid-level speed 5, and sets its 20 minute timer. The Speed+ and Speed buttons also Activate (brighten). To adjust the intensity of the Blower: 1. Check that the Blower Button is Active (bright). 2. Press and hold the Speed+ or Speed- Button to slowly increase or decrease the respective speed (ranging from S10 to S1) until the desired intensity is reached. Press and release the Speed+ or Speed- Button to increase or decrease the respective intensity by one full speed. 3. Press the Blower Wave Mode Button to have it oscillate between the highest and lowest speeds. Pressing it again will cancel Wave Mode, and revert to Speed Mode. To turn the Blower off: 1. Check that the Blower Button is Active (bright). 2. Press and release the Blower Button. The Blower will turn off, and the associated Buttons will De -Activate (dim). Tub Light: To activate the Tub Light, and set its 30 minute Timer, press and release the Tub Light Button. The first press will put the light in a Rainbow mode, rotating through each of the color variations (displays Color C00). Subsequent press-and-release of the Light Button will illuminate one color in the following order: White, Blue, Aqua, Green, Yellow, Red, Magenta (Colors C01 C07). Press-and-releasing of the Light button after C07 or press-and-holding at any time will turn it off. Timers: Each function will turn off once its individual Timer has run out. If the bath empties during operation, the system will turn off, and it will flash NO H2O (No Water) three times, then go out. User Settings: To store your favorite bath setting in memory, press and hold the User Set Button until it displays STOR, then release. To recall it at a later time when the bath is running, press and release the button. Pump Jets Blower Speed+ Tub Light Purge Cycle: 30 minutes after the tub has been drained, the Keypad will show DRY, and the Blower will run for 1 minute to remove the water from the lines. Page 6 Pump Wave Blower Wave Speed- User Set

TOUCHSTONE Variable Speed Bath System Installation & Operating Manual Variable Speed Pump Configuration #2 System Identification: CIDU-315-03-02-01 Configuration #2 Variable Speed Pump System features: Electronic Keypad, Independent Timers, 10- Speed Pump, Multi-Color LED Tub Lights, Capacitive Water Detect. Controller Installation: To 120V GFCI Protected Receptacle Power Out TO PUMP 13.5 Amp Motor Nameplate Max CICL-297 CITW-209 Male Cord Female Cord CILA-301 CCBL-366 CCBL-168 CIDU-315-03-02-01 CIMC-288-01-03-01 NOTES: 1. Use wire clips provided to retain cables. 2. CAUTION: Do not plug 8-pin cables into 6-pin ports or damage may result to system. 3. Connect cables to ports as shown. CAUTION: Failure to connect cables to ports as shown, may damage the control box and its components. Operation: When the Controller detects that there is sufficient water in the tub, all the buttons will light dim, and the Bath Temperature will display. Pump Speed+ Speed+ Wave Mode Speed- Tub Light User Set Page 7

Variable Speed Pump Configuration #2 (continued) Pump: Press and release the Pump Button to turn it On. This Activates (brightens) the Pump Jets button, turns on the Pump at mid-level speed 5, and sets its 20 minute timer. The Speed+ and Speed buttons also Activate (brighten). Press and release at any time to turn it Off, and the associated Buttons will De- Activate (dim). Press and hold the Speed+ or Speed- Button to slowly increase or decrease the respective speed (ranging from S10 to S1) until the desired intensity is reached. Press and release the Speed+ or Speed- Button to increase or decrease the respective intensity by one full speed. To activate the Pump Wave Mode, press and release the Pump Wave Button and the Pump will oscillate between the highest and lowest speeds. Press and release the Button again to return to regular speed operation. Tub Light: To activate the Tub Light, and set its 30 minute Timer, press and release the Tub Light Button. The first press will put the light in a Rainbow mode, rotating through each of the color variations (displays Color C00). Subsequent press-and-release of the Light Button will illuminate one color in the following order: White, Blue, Aqua, Green, Yellow, Red, Magenta (Colors C01 C07). Press-and-releasing of the Light button after C07 or press-and-holding at any time will turn it off. Timers: Each function will turn off once its individual Timer has run out. If the bath empties during operation, the system will turn off, and it will flash NO H2O (No Water) three times, then go out. User Settings: To store your favorite bath setting in memory, press and hold the User Set Button until it displays STOR, then release. To recall it at a later time when the bath is running, press and release the button. Pump Speed+ Speed+ Tub Light Wave Mode Speed- User Set Page 8

TOUCHSTONE Variable Speed Bath System Installation & Operating Manual Variable Speed Blower Configuration #3 System Identification: CIDU-315-03-02-01 Configuration #3 (Variable Speed Blower) System features: Electronic Keypad, Independent Timers, 10- Speed Blower, Multi-Color LED Tub Lights, Capacitive Water Detect. Controller Operation: To 120V GFCI Protected Receptacle TO BLOWER Max 15 AMPS Load CICL-297 CITW-209 CILA-301 CCBL-366 CCBL-168 CIMC-213 01-03-01 CIDU-315-03-02-01 NOTES: 1. Use wire clips provided to retain cables. 2. CAUTION: Do not plug 8-pin cables into 6-pin ports or damage may result to system. 3. Connect cables to ports as shown. CAUTION: Failure to connect cables to ports as shown, may damage the control box and its components. Operation: When the Controller detects that there is sufficient water in the tub, all the buttons will light dim. Blower Speed+ Speed+ Tub Light Wave Mode Speed- User Set Page 9

Variable Speed Blower Configuration #3 (continued) Blower: Press and release the Blower Button to turn it On. This Activates (brightens) the Blower button, turns on the Blower at mid-level speed 5, and sets its 20 minute timer. The Speed+ and Speed buttons also Activate (brighten). This sets the 20 minute Blower Timer, and the Blower Speed to mid-level Speed 5. Press and release at any time to turn it Off, and the associated Buttons will De-Activate (dim). Once set, the Keypad will display the remaining Time. Press and hold the Speed+ or Speed- Button to slowly increase or decrease the respective speed (ranging from S10 to S1) until the desired intensity is reached. Press and release the Speed+ or Speed- Button to increase or decrease the respective intensity by one full speed. -To activate the Blower Wave Mode, press and release the Wave Mode Button. The Blower will oscillate between the highest and lowest speeds. Press and release the Button again to return to regular operation. Tub Light: To activate the Tub Light, and set its 30 minute Timer, press and release the Tub Light Button. The first press will put the light in a Rainbow mode, rotating through each of the color variations (displays Color C00). Subsequent press-and-release of the Light Button will illuminate one color in the following order: White, Blue, Aqua, Green, Yellow, Red, Magenta (Colors C01 C07). Press-and-releasing of the Light button after C07 or press-and-holding at any time will turn it off. Timers: Each function will turn off once its individual Timer has run out. If the bath empties during operation, the system will turn off, and it will flash NO H2O (No Water) three times, then go out. User Settings: To store your favorite bath setting in memory, press and hold the User Set Button until it displays STOR, then release. To recall it at a later time when the bath is running, press and release the button. Purge Cycle: 30 minutes after the tub has been drained, the Keypad will show DRY, and the Blower will run for 1 minute to remove the water from the lines. Blower Speed+ Tub Light Wave Mode Speed- User Set Page 10

TOUCHSTONE Variable Speed Bath System Installation & Operating Manual System Troubleshooting For the general troubleshooting issues related to TOUCHSTONE product, please refer to the TOUCHSTONE General Troubleshooting Guide. System Identification and Verification: The first step in troubleshooting is to verify that the hardware required for the system is complete and installed correctly. Each Control System is identified by the Keypad Part Number and the Configuration Number. Cable Verification: Verify that the cables are connected correctly, and that the pins are straight and free of damage. The Display Unit cable may have a Red Flag on the end, and is connected to the Controller s corresponding port, marked in Red. The Tub Light Accessory s cable may have a Yellow Flag on the end, and is connected to the Controller s corresponding port, marked in Yellow. NOTE: If these cables were cross-connected or forced-in at any point, irreparable damage may result, and any warranty will be void. Should this happen, replace all the affected components, ensuring that they are connected correctly. Power Verification: Each blue control box has a green power indicator light on the face where the Keypad plugs in. These should be constantly illuminated when power is on to the system. If it is not lit, use a meter or suitable device such as a drill motor or hairdryer to verify that there is power to the Control System at the receptacle under the tub. Verify and check that the circuit has GFCI protection, and that the GFCI is functioning properly. Configuration Verification: Each system is capable of operating a number of different configurations. In order to run the specific system at hand, the correct Configuration must be selected when components are replaced. To verify the Configuration that the Keypad is set to, simply cycle the power to the system and observe the Keypad. On Keypads with an Alphanumeric LED display, it will show Cxx after a few seconds, where xx is the Configuration number. NOTE: Once the Configuration is set it will not be affected by cycling the power, it needs only to be set initially. Load Verification (Pump, Blower, etc.): If a Load will not turn off: Unplug the Keypad. If the load is still on, there is a fault in the Control Box. Replace the Control Box. If a Load will not turn on: Referring to the Operating Instructions section, confirm that the Load is plugged into the correct Receptacle of the correct Control Box. If it still does not function, verify that the Load is operational by plugging it directly into a known-good wall receptacle. If not, replace the Control Box or Load accordingly. Non-Functional Keypad: If the Keypad is not functioning, check that the control box has power by observing the green power indicator LED on the control box is illuminated. Next, check the cable connecting the Keypad to the control box making sure that both connections are secure and the retaining clips (if present) are attached. Inspect each cable end to make sure that the pins are not bent or missing. If the Keypad is still non-functional, replace the Keypad and the Cable. Set the Keypad to the proper Configuration and test the system. Error Codes on the Keypad: The Alphanumeric LED Display registers hardware conflicts as error codes in the form of E##. Refer to the General TOUCHSTONE Troubleshooting Guide for list of error codes. Page 11

Retain this manual for future reference For your records and future reference please fill in data below: Manufacturer: Model: Serial: Date of Installation: Page 12 NuWhirl Systems Corp www.nuwhirl.com 951-817-5600 MAN315030201 REV A 4/10/2017