EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Similar documents
ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

We Identify and S.T.O.P. Your Noise Problems

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

FUNDERMAX GMBH FIRE TEST REPORT

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

c. Oko-Tex (European environmental health standard)

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

~ 0."0... DESCRI PT ION OF TEST SAM PLE

SIGMADEK, LTD. FIRE TEST REPORT

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Report on Public Input June 2014 NFPA 101

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

ARCHITECT S SPECIFICATIONS

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

SHAW CONTRACT DESCRIPTION OF TEST SAMPLE

ARCHITECT S SPECIFICATIONS For Commercial Vinyl Wallcoverings

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

Wallpaper Hanging Instructions

Be inspired... hanging wallpaper. CONTACT US ON 0861 SHAVES OR VISIT OUR WEBSITE AT FOR A STORE NEAR YOU

Public Comment No. 2-NFPA [ Section No ]

Write Walls Dry Erase Specification Data (Section 09720)

GUARDIAN FIRE TESTING LABORATORIES, INC.

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

Report on First Revision June 2014 NFPA 101

mason What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

Materials Testing by Gregory Havel

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Fire Test Methods ASTM NFPA UL ISO IEC

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Wallpaper Buying Guide

Inc. PACE 1 of 2. Testing Laboratory. AA TCC Test Method Electrostatic Propensity of Carpets TEST M ET"ODCON D UCTED

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

STilE/DIVISION OF SHAW DESCRI.P TION 0 FT E STSAMP L E

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

STilE/DIVISION OF SHAW

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

(front cover) Tatami Nara, ashlar. (left) Tatami Straw and Rush, monolithic. (back cover) Tatami Zen.

STilE/DIVISION OF SHAW DESCRIPTION OF TEST SAMPLE

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

DESCRIPTIO NOFTESTSAMP

C-01 FIRE DECKS AND BULKHEADS

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Public Comment No. 1-NFPA [ Section No ]

chiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

PRODUCT INFORMATION FOR CHARLES RUPERT DESIGNS WALLPAPERS October 2007

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Acoustical Surfaces, Inc.

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

MagScapes Product Guide

Non Woven Wallcoverings with or without Crystals Installation and Maintenance Guidelines

Madagascar Sky Blue Wallpaper

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

venetian plaster exclusivewallcovering Low VOC LEED IEQ 4.2 CAL 1350 & CHPS certified VINYL WALLCOVERING Fire classification

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

Test Report: ICL/H18/9039 Rev 1

Report of Surface Burning Characteristics Test on Acoustical Panel

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

EXAMPLE SPECIFICATION ONLY

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Temporary LPG Heat for Construction Sites Information Packet

Porta Mural Wallpaper

RETAIL ENVIRONMENTS AND DISPLAYS FIXTURES WALLCOVERINGS SIGN. STAND OUT. Grab the attention of your customers with eye catching colors and textures.

Banda Cay Wallpaper. eskayel.com T South 6th Street Brooklyn, NY 11249

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

HP PVC-free Durable Wall Paper

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

Transcription:

by NEENAH EnviroScape Mural pre-pasted printable wallcovering material EnviroScape Mural is a PVC free wall, window or hard surface scaping product that is pre-pasted with a water activated adhesive backing system, making it easy to install and just as easy to remove, while supporting LEED credit certiication for green building applications. To achieve sustainable advantage over traditional pressure sensitive vinyl materials, this high performance and dimensionally stable product is iber based and incorporates 10% post-consumer waste in its construction. EnviroScape Mural is available in Smooth or Textured, for a unique embossed surface inish. Installation: Spray water to the back of the sheet until thoroughly saturated. Gently fold the sheet with adhesive parts facing each other to keep moist and allow adhesive paste to activate. Set aside for one minute. Unfold sheet and place onto a wall from top to bottom. Carefully smooth out bubbles and creases using a broad smoothing brush, not a squeegee, from the middle of the sheet out. If necessary, spray again with water around the edges during the entire process. Allow surface to dry to the touch and wipe of any excess adhesive using a damp cloth or sponge. Wait for mural to dry completely and trim if necessary using a straight knife with a fresh blade tip. Removal: Spray the surface with water to allow paste adhesive to relax for easier removal. Start from top to bottom, drawing the product back on itself at a 180 degree angle. Spray with more water if necessary. Use a wet cloth to remove any remaining adhesive from surface. APPLICATIONS Murals Wall décor Pole wrap POP signage Window signage PRODUCT SAFETY ASTM E-84 Fire Rating Printability: UV, Latex, Ofset, Screen Choose your GREEN resource from a leading solutions provider. 70 Front Street, West Springield, MA 01089 888-977-5050 naturally creative

EnviroScape Mural pre-pasted printable wallcovering material Technical Data Caliper Basis Weight (gsm) Smoothness / Sheield Brightness % Opacity 10 pt / 10 mil 280 < 30 88+ 97% These are typical values of the product as produced representing a manufacturing range. Slight variations may occur during the manufacturing process. Availability Size Core 50 x 150 / 127cm x 45.7m 3 50 x 300 / 127cm x 91.4m 3 Commercial sizes available upon request. Call for a quote. 70 Front Street, West Springield, MA 01089 US & CANADA: 888-977-5050 INTERNATIONAL: 413-533-0338 www.neenahpaper.com/ibermark naturally creative

COMMERCIAL TESTING COMPANY 1215 South Hamilton Street Dalton, GA 30720 Telephone (706) 278 3935 Facsimile (706) 278 3936 Standard Method of Test for Surface Burning Characteristics of Building Materials ASTM E 84 10 EnviroScape Mural Plus! Report Number 11 02218 Test Number 4192 2104 0211R February 21, 2011 ConVerd East Longmeadow, Massachusetts Commercial Testing Company (Authorized Signature) This report is provided for the exclusive use of the client to whom it is addressed. It may be used in its entirety to gain product acceptance from duly constituted authorities. The test results presented in this report apply only to the samples tested and are not necessarily indicative of apparent identical or similar materials. Sample selection and identification were provided by the client. A sampling plan, if described in the referenced test procedure, was not necessarily followed. This report, or the name of Commercial Testing Company, shall not be used under any circumstance in advertising to the general public. TESTED TO BE SURE Since 1974

INTRODUCTION This report is a presentation of results of a surface flammability test on a material submitted by ConVerd, East Longmeadow, Massachusetts. The test was conducted in accordance with the ASTM International fire test response standard E 84 10, Surface Burning Characteristics of Building Materials, sometimes referred to as the Steiner tunnel test. This test is applicable to exposed surfaces such as walls and ceilings. The test is conducted with the specimen in the ceiling position with the surface to be evaluated exposed face down to the ignition source. The ASTM E 84 test method is the technical equivalent of NFPA No. 255 and UL No. 723. This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of materials, products, or assemblies under actual fire conditions. PURPOSE The purpose of the test is to provide only the comparative measurements of surface flame spread and smoke development of materials with that of select grade red oak and fiber reinforced cement board, Grade II, under specific fire exposure conditions. The test exposes a nominal 24-foot long by 20-inch wide test specimen to a controlled air flow and flaming fire adjusted to spread the flame along the entire length of a red oak specimen in 5.50 minutes. During the 10-minute test duration, flamespread over the specimen surface and density of the resulting smoke are measured and recorded. Test results are calculated relative to red oak, which has an arbitrary rating of 100, and fiber reinforced cement board, Grade II, which has a rating of 0. The test results are expressed as Flame Spread Index and Smoke Developed Index. The Flame Spread Index is defined in ASTM E 176 as a number or classification indicating a comparative measure derived from observations made during the progress of the boundary of a zone of flame under defined test conditions. The Smoke Developed Index, a term specific to ASTM E 84, is defined as a number or classification indicating a comparative measure derived from smoke obscuration data collected during the test for surface burning characteristics. There is not necessarily a relationship between the two measurements. The method does not provide for measurement of heat transmission through the surface tested, the effect of aggravated flame spread behavior of an assembly resulting from the proximity of combustible walls and ceilings, or classifying a material as noncombustible solely by means of a Flame Spread Index. The zero reference and other parameters critical to furnace operation are verified on the day of the test by conducting a 10 minute test using 1/4 inch fiber reinforced cement board, Grade II. Periodic tests using NOFMA certified 23/32 inch select grade red oak flooring provide data for the 100 reference. TEST SAMPLE The test sample, selected by the client, was identified as EnviroScape Mural Plus!, a water activated wallscaping material with a total weight of 4.9 ounces per square yard. Three test panels, each measuring two feet wide by eight feet in length, were prepared by adhering the material to 5/8 inch thick Type X gypsum wallboard. After soaking the wallcovering in water to activate the adhesive, the material was booked 5 to 7 minutes, then placed onto the face of the gypsum board and smoothed with a brush and roller. After dead-stacking overnight, the prepared panels were transferred to storage racks and conditioned to equilibrium in an atmosphere with the temperature maintained at 71 ± 2 F and the relative humidity at 50 ± 5 percent. For testing, the panels were placed end to end on the ledges of the tunnel furnace and tested with no auxiliary support mechanism. This method of sample preparation is described in Appendix X1 of the E 84 standard, Guide to Mounting Methods, Section X1.9.4. TEST RESULTS The test results, calculated on the basis of observed flame propagation and the integrated area under the recorded smoke density curve, are presented below. The Flame Spread Index obtained in E 84 is rounded to the nearest number divisible by five. Smoke Developed Indices are rounded to the nearest number

divisible by five unless the Index is greater than 200. In that case, the Smoke Developed Index is rounded to the nearest 50 points. The flame spread and smoke development data are presented graphically at the end of this report. Test Specimen Flame Spread Index Smoke Developed Index Fiber Reinforced Cement Board, Grade II 0 0 Red Oak Flooring 100 100 EnviroScape Mural Plus! 15 0 OBSERVATIONS Specimen ignition over the burners occurred at 0.18 minute. Surface flame spread was observed to a maximum distance of 3.61 feet beyond the zero point at 1.72 minutes. The maximum temperature recorded during the test was 557 F. CLASSIFICATION The Flame Spread Index and Smoke Developed Index values obtained by ASTM E 84 tests are frequently used by code officials and regulatory agencies in the acceptance of interior finish materials for various applications. The most widely accepted classification system is described in the National Fire Protection Association publication NFPA 101 Life Safety Code, where: Class A 0 25 Flame Spread Index 0 450 Smoke Developed Index Class B 26 75 Flame Spread Index 0 450 Smoke Developed Index Class C 76 200 Flame Spread Index 0 450 Smoke Developed Index Class A, B, and C correspond to Type I, II, and III respectively in other codes. They do not preclude a material being otherwise classified by the authority of jurisdiction.

ASTM E 84 TEST DATA Client: ConVerd Test Number: 4192-2104-0211R Material Tested: EnviroScape Mural Plus! Date: February 21, 2011 Test Results: Time to Ignition = 00.18 minutes Maximum Flamespread Distance = 03.61 feet Time to Maximum Spread = 01.72 minutes Flame Spread Index = 15 Smoke Developed Index = 0 20 18 16 14 Distance, feet 12 10 8 6 4 2 0 Time, minutes Transmittance, % 100 90 80 70 60 50 40 30 20 10 0 Time, minutes