WorkWrite-Up and Bid DocumentlBy Trade Suzanne Duncan 428 Amanda Lynn Lane Stilwell, OK 7-496 (918) 458-7810 Contractor Name: Contractor Signature: This document must be signed to be a valid bid. PROJECT TYPE: Rehabilitation Bid Due Date: Appliances 1 Area: KTCHEN Oishwasherllnstall new. nstall new Energy Star certified dishwasher. Div.# 10.F. 2 Area: KTCHEN Div.# 10.F Oven/Range/Gas/30"/Free Standing. nstall new 30" free standing gas range/oven with clock, oven window and one-year manufacturer's warranty. 3 Area: KTCHEN Div.# 10.F Refrigerator/Top Freezer/Energy Star/18.2 C.F. Mirnium Size/lnstall new. nstall new 18.2 C.F. (minimum size) refrigerator with top freezer. Must be Energy Star compliant. 4 Area: KTCHEN Div.# 10.0. 3.0 Vent-A-Hood/30"/Ext. Vented/lnstall new kitchen vent-a-hood (ext.vent)/30" Carpentry 5 Area: KTCHEN Div.# 6.0.2 8 LF Base Cabinets/Replace/Oak. Replace base cabinets with new cabinets, pre-finished oak. Print Date: Monday, December 18,2017 428 Amanda Lynn Lane Stilwell, OK 7-4960 Page 10/8
Carpentry 6 Area: NTEROR Div.# 6.Z.2. Closet Shelf/Metal Wire Grid/12" x 5'. nstall new wire grid shelving/12" depth x 5' long. Shelves shall have free-sliding rail for hangers. Use Closet Maid or written approved equal. nstall a shelf over washer and dryer. 7 Area: KTCHEN Countertop/New/Post Form Top. nstall new countertop and backsplash. Div.# 6.0.4. 8 Area: EXTEROR Div.# 8.A. Door/Exterior/6-Panel SteelPre-Hung/Replace. Replace exterior entrance door with new pre-hung-steel six panel door. Work shall include paint-both sides, lockset, dead bolt & peephole. 9 Area: GARAGE Div.# 8.C Garage Vehicle Door/Steel/8' x T/Replace. Replace existing garage vehicle door with new steel overhead garage vehicle door--8' X T. 10 Area: BATHROOM #2 Div.# 11.2.Z Medicine Cabinet/Oak with Tri-View Mirror. nstall new medicine cabinetltri-view Mirror/Oak frarne-su" x 32". nstall in both bathrooms. 11 Area: BATHROOM #2 Div.# 10.E. 2. Paper Holder/Replace replace in both bathrooms. paper holder 8lF 4Ea 1 1 1 Print Date: Monday, December 18,2017 428 Amanda Lynn Lane Stilwell, OK 7-4960 Page 2 of8
Carpentry 12 Area: NTEROR Div.# 8.A Passage Door, Jamb & Trim/Pre-Hung/6-Panel/Replace passage door & lockset with new pre-hung 6-Panel. Work shall include paint both sides. 14 Ea 13 Area: EXTEROR Div.# 8.B 4Ea Storm Door/Aluminum/Mill finish/replace. Replace storm/screen door with new aluminum storm door (self storing)/mill finish. 14 Area: BATHROOM #2 Div.# 10.E. 2. Towel Bar/Replace. Replace exising towell bar with new towel bar. Match existing size or as specified in Comments below. Replace in both bathrooms. 15 Area: KTCHEN Div.# 6.0.2 Wall Hung Cabinets/Replace/Pre-Finished pre-finished oak cabinet(s). Oak. Replace wall hung cabinet(s) with new 10 LF Drywall & Finish 16 Area: ENTRE STRUCTURE Div.# 9.D. Drywall/Ceiling Or Wall/Small Area/Replace 1/2". Replace small area of drywall with new 1/2" drywall. Work shall include tape, bed, texture and paint to match existing as closely as possible. replace and patch sheet rock as needed. 96SF Electrical Print Date: Monday, December 18, 2017 428 Amanda Lynn Lane Stilwell, OK 7-4960 Page30J8
Electrical 17 Area: ENTRE STRUCTURE Div.# 13.0. 5Ea 9.B Ceiling Fan, Light Kit & Circuit Wiring/52". nstall new ceiling fan (52" wllifetime warranty) with light kit, switch, cover plate and wiring. nstall in kitchen, living room and all bedrooms. 18 Area: ENTRE STRUCTURE Div.# 13.0. 6. Cover Plate/Switchllnstall new switch cover plate. 15 Ea 19 Area: ENTRE STRUCTURE Oryer Outletl220v. Replace 220 dryer outlet & cover. Div.# 13.0. 20 Area: BATHROOM #1 Div.# 13.0. Light Fixture & SwitchlWet Area/Replace. Replace existing light fixture and switch with new wet-area approved light fixture and switch. 21 Area: GARAGE Div.# 13.0. 9. Light Fixture, Fluorescent/4 Bulb/Replace. Replace existing ceiling fixture with new 4 bulb (32 watt T8 lamps), decorative fluourescant light fixture with oak ends. Fixture allowance $60.00. 22 Area: ENTRE STRUCTURE Div.# 13.0. Outletl110v Single Receptacle/20 Amp/Grounded/Replace. Replace existing 110 duplex outlet and cover with new single receptacle outlet and cover plate. 24Ea Print Date: Monday, December 18,2017 428 Amanda Lynn Lane Stilwell, OK 7-4960 Page 4 0/8
Trade Work Description / Comments Gen. Spec. Qty Ullit tem Bid Electrical 23 Area: ENTRE STRUCTURE Div.# 13.D. 5 Ea 11 Smoke Detector!Battery Operated!lnstali new smoke detector, battery operated (10 year lithium battery). All bedrooms and hallways adjacent to bedrooms. Use Firex #4015 or written approved equal. Flooring 24 Area: ENTRE STRUCTURE Div.# 9.M Carpet & Pad!Level Loop!26 oz.llnstall new carpet (26 OZ., levelloop)and pad (15 oz.). nstall in livingroom, hallway and all bedrooms. 25 Area: ENTRE STRUCTURE Div.# 9.L Vinyl Floor Tile. Replace existing flooring with new vinyl floor tile!12" x 12" x 1!8". nstall in bathrooms, and kitchen. HVAC -- 26 Area: NTEROR Div.# 12 HVAC Equipment/Central/Cooling! Heating!3 TON!13 SEER. Replace existing HVAC equipment (13 SEER). NSDE FURNACE AND OUTSDE EQUPMENTNCLUDNG AR HANDLER, COPPER LNES, CONDENSOR COLS, EVAP. COLS. AND COMPRESSOR. Gas unit. Paint & Finish 27 Area: ENTRE STRUCTURE Div.# 9.N.4 Siding & Trim!Paint/Two Coats. Paint exterior siding & trim (two coats). Does include soffit & fascia. nclude cleaning, caulking and filling of small holes. NOTE:SF=WALL AREA. 75SY 255 SF 1000 SF 1_, Print Date: Monday, December 18,2017 428 Amanda Lynn Lane Stilwell, OK 7-4960 Page 5 0/8
Paint & Finish 28 Area: ENTRE STRUCTURE Div.# 9.N.3 1200 SF Walls & Ceiling/Drywali/PaintlTwo coats. Paint walls & ceiling in entire area. Work shall include minor repairs to surfaces. SF=ACTUAl SURFACE AREA OF WAllS & CELNG. Plumbing 29 Area: BATHROOM #1 Div.# 11.A Bathtub-Shower Combination/Acrylic fiberglass/pre-fab/2 Piece. Replace existing bathtub/shower combination with new 2 piece acrylic fiberglas tub/shower unit. 30 Area: BATHROOM #1 Div.# 11.A Commode & Seat/nstall new commode, seat, supply line, shutoff and wax seal. Use American Standard Cadet or written approved equal. nstall in both bathrooms. 31 Area: KTCHEN Div.# 11.A Faucet/Kitchen/Single Handle. Replace kitchen faucet with new single handle faucet, supply lines & shutoffs.. 32 Area: BATHROOM #1 Div.# 11.A 6lF lavatory-vanity Cabinet/Replace. Replace existing lavatory-vanity cabinet with new vanity cabinet (pre-finished oak). Match existing size. Replace in both bathrooms. 33 Area: BATHROOM #1 Div.# 11.A lavitory FauceWanityllnstall new vanity faucet, drains, supply lines & shutoffs. Replace in both bathrooms. Print Date: Monday, December 18,2017 428 Amanda Lynn Lane Stilwell, OK 7-4960 Page 60/8
Plumbing 34 Area: BATHROOM #2 Div.# 11.A Shower Faucet & Diverter/Single Lever/nstall new bath/shower faucet with diverter. Work shall include installation of pre-fab access panel or removal and replacement of wall materials on opposite wall to faucet. Replace in both bathrooms. 35 Area: BATHROOM #2 Div.# 11.A Shower Stall Replace/48" x 36" x 74-1/2- inch. nstall 5-Piece shower stall w/ base, 2- side walls & 1-shower back and a removable seat. nstall (3) grab bars (1)- 36" @ the back, and( 2)-24" one on each end.use: Sterling # 72280100-0 36 Area: KTCHEN Div.# 11.A Sink & Faucet/Kitchen. nstall new stainless stell kitchen sink (33" x 22" x 7") & Faucet (Use Delta single-handle model100-wf or written approved equal). Work shall include new drain lines, trap and shutoffs (2). 37 Area: NTEROR Div.# 11.A Water Heater/Gas/40 Gallon/Replace. Replace existing gas water heater with new 40 gal. gas water heater. Work shall include elevating to 18" (if in garage), replacement of TPR, all combustion air, gas & electrical hook-ups for code legal installation. Site Work 38 Area: ENTRE STRUCTURE Cleanup/Final. Final cleanup of entire Project. Remove debris from interior and exterior. Div.# 1200 SF Print Date: Monday, December 18,2017 428 Amanda Lynn Lane Stilwell, OK 7-4960 Page 7 of 8
Trade Work Description / Comments Gen. Spec. QtyUnit tem Bid All construction shall be in accordance with local codes, manufacturers' recommended installation procedures, good quality workmanship practices, General Specifications and Lead- Based Paint requirements when applicable. Conflicts between requirements will be resolved by compliance with the more stringent requirement. Contractor awarded the job will be responsible for conducting safe work practices that comply with OSHA Construction Standards for Asbestos Workers. Asbestos report, where required, will be attached if areas tested are 1% or greater. See attached Asbestos Sampling Report for location and testing of Planned Work Activities. Total: 1 1 Print Date: Monday, December 18,2017 428 Amanda Lynn Lane Stilwell, OK 7-4960 Page 8 of8
Suzanne Duncan-site directions: Take higway 51 west from Stilwell go past en and turn right onto Amanda Lane, it the 1ih house on the left.