AIRFLOW SPECIFICATIONS

Similar documents
ALARM FOR SAFETY CABINETS SPECIFICATIONS

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Installation & Calibration Guide

Fume Hood Operating Display Panel

DMFPM-2R MULTIFUNCTIONAL

AFA 500 FUME HOOD ALARMS

Static Pressure Alarm For Hazardous Location Fume Hoods

FCCP 200: Fume-cupboard indicator and monitor

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

AFA1000/1 MK3 Airflow Monitor

Excellence in Level Measurement

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Door Release Power Supply

AirGard. Air Flow Monitors

RPM1600 Series Room Pressure Monitors

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Model 405 AIRGARD Fume Hood Monitor

Technical Catalogue laboratory furniture system

Laser Distance Sensor Type M Analog-Output

IP/Network Doorbell. Quick Installation Guide V3.1

Software Version 2.01 LEVEL MONITOR MODEL 220

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Analog Room Pressure Monitor RPC Series

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ANALOX 3000 Carbon Monoxide Monitor

Single Channel Heater Controller

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

METEOROLOGICAL INSTRUMENTS

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Technical Catalog laboratory furniture system

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Premier Hazard STC Instructions

KM300 Carbon Monoxide Detection System Installation Manual

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

METEOROLOGICAL INSTRUMENTS

LABCONCO 1000 GUARDIAN DIGITAL MONITOR Operating and Instruction Manual

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

TBR 40 1 GD Blood Refrigerator Instruction Manual. for BLOOD STORAGE REFRIGERATORS MODEL TBR 40 1 GD. (40 x 500ml Blood Bag Capacity)

FMH Range Hoods. Installation, Operation & Maintenance Instructions

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

FUME HOOD MONITOR ALNOR AIRGARD 335

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

RS Pro Infrared Temperature Sensor

S E R M A N U A L. Alarm. Module. Rooster Monitor100

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

HVAC Controls Laboratory. Model EVERWATCH Face Velocity Monitor. Operation and Service Manual. P/N , Revision E October 2002

A measured step forward

FUME HOOD MONITOR ALNOR AIRGARD 200

SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

Sintrol Snifter A1+ Manual. Version 1.2.2

Electronic Thermostat With RF

Pioneer-R16 Gas Monitor Operator s Manual

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Secuflow laboratory fume cupboards

ESSEX ENGINEERING CORPORATION

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS

ACCURATE ELECTRONICS INC

Central Temperature Monitoring/Control System (I IOT Cloud solution)

EDD61 & EDD91 Extractors

Secuflow laboratory fume cupboards

ATOMLAB XENON TRAP MONITOR OPERATION AND INSTALLATION MANUAL FN: /12

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

APM110 LOW AIR VELOCITY ALARM

Programmable Room Thermostat Installation Instructions

OPERATING INSTRUCTIONS

S304 and S305 Dust Emission Monitors. User Manual. Distributor

3M Benchtop Air Ionizer 963E. User s Guide

RF Programmable Room Thermostat Installation Instructions

WatchDog Wireless Crop Monitor Operation Manual

CIRCULAIRE LAMINAR AIR FLOW

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

RLD-H10P Refrigerant Leak Detector

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Poolsmart Plus Touchscreen Heating Controller. Installation & Operating Manual

Snifter. User Manual. Distributor

VF Series. User Manual. SKOPE Vertical Freezer. MAN10521 Rev. 3.3 Jun VF1000

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Installation and user manual for the BiWire / Conventional Repeater Panel

Figure 1-1 Furnace Front Elevation

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Transcription:

Specs Junior Version V.4 LABORATORY AIRFLOW MONITOR TYPE JUNIOR SPECIFICATIONS Parc Technologique Delta Sud * 09340 Verniolle * France Tel + 33 5 61 69 84 43 * fax + 33 5 61 67 86 03 info@seat-ventilation.com * www.seat-ventilation.com 1

GENERAL DESCRIPTION Benefits Safety: in accordance with latest EU laboratory standard EN 14175. Ease of installation and maintenance Stable and accurate sensor reading Attractive design Applications Principally adapted for chemical storage cabinets, general exhaust systems Features Audio alarm 1 Pushbutton: Mute 1 red LED 1 green LED Colors Plastic fascia is available in white standard color. Components Circuit board: Panel mounted circuit board to be installed vertically onto the exhaust system (storage cabinet for example) with 2x Ø 2.8mm screws. IP55 protection ensured by O ring seal. Face plate to be supplied with chemical resistant plastic sticker (vertical) with control/push buttons on fascia. Surface box mounting included. Sensor: To be installed inside the exhaust system (storage cabinet for example). Sensor measures air speed variations inside. Supplied with a 3.5m (5m optional) shielded cable with pin connections onto controller circuit board. Power supply: 230Vac to 12Vdc power transformer directly into controller circuit board. Comes with a Euro 2 pin plug/cord. Adaptor may be required to fit local power socket International Standards Compliance In accordance with: - European laboratory standard EN 14175-2 - Electromagnetic standards EN 61326:1997 / A1 : 1998 /A2 : 2001 / A3 : 2003 (Test report RC-05-42060-1) US FCC Part 15 Class B edition 2005 (Test report RC-05-42060-2- A). - European RoHS directive governing disposal and recycling of electronics - French laboratory standard XPX 15203 of Sept 1996 Packing Supplied in cardboard box which includes controller circuit board, surface box mounting, face plate, sensor and power transformer. 2

OPERATING PRINCIPLE When the fume extraction fan is running, it causes negative pressure inside the storage cabinet. In normal use (doors closed), the pressure is high, the air speed at the entry of the storage cabinet is constant. Conversely, since the door opening or a default of the ventilation system, the pressure decrease and air velocity reduces. SEAT Junior AirControl exploits this by the placing of a numerical sensor, or thermal anemometer, into a hole in the cupboard and sending the air velocity measurement obtained to a display on the fascia panel. The air velocity level is visualized on the fascia by LED illumination. All functioning anomaly activate an audible alarm. SENSOR SEAT JUNIOR AIRCONTROL 3

SCHEMATIC JUNIOR 230ac/12Vdc power supply Controller sensor SENSOR SIGNAL INPUT Sash High Alarm input Doors mouvement or extraction system default = Pressure decrease or increase 4

SPECIFICATIONS Junior AirControl Part Number 819699 Display-Visual Alarm Setpoint Alarm Indication Alarm Mute Mounting Calibration Power Requirement Orientation Monitor Dimensions 1 Green LED for normal air speed 1 Red LED flashing for alarm No digital display Standard : below 0.39m/s 1 red LED flashing and audible buzzer Flush or surface box Factory pre-calibrated @ 0.5m/s. Recalibration possible 12Vdc (power supply included) Vertical only Front fascia: 100L x 70W x 10D mm Surface box: 100L x 20W x 20D mm 5

SPECIFICATIONS Monitor + Mounting Box 20 70 100 9 0 100 Mounting Box 20 Vis Ø 2.8 Sensor 65 28 Cable L = 3.5m 40 Ø 22 NOTE: All dimensions in mm 6

OVERALL VIEW Front plate / fascia Chemical and pressure resistant sticker Alarm Mute push button Flashing red LED for alarm: air speed too low 1 green LED lit up: Airflow OK 7