Vote for your Installer of the year at HEATSLAVE

Similar documents
DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

24CDi, 28CDi & 35CDi II COMBI

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32

Greenstar 12i/24i System

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

Greenstar 12i system / 24i system

GREENSTAR HIGHFLOW 440/550CDi

GREENSTAR HEATSLAVE II ErP+ 12/18, 18/25 & 25/32

Greenstar 24i junior / 28i junior


GREENSTAR HIGHFLOW 440/550CDi

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Baxi Maxflow Combi WM

GREENSTAR i SYSTEM USER MANUAL WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER FOR CENTRAL HEATING SYSTEMS UK/IE (2013/08)

WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER GREENSTAR 24i Junior/28i Junior

WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER

User's Instructions. Alpha CB50

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Baxi Maxflow Combi FS

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

USERS GUIDE 24, 30. For installation guide see reverse of book

Greenstar System Filter

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

GREENSTAR Ri USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER FOR CENTRAL HEATING SYSTEMS a (2010/10)

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

GREENSTAR Ri ErP. User instructions UK/IE. Wall hung RSF gas fired condensing regular boiler. For central heating systems

GREENSTAR i JUNIOR USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Logic+ Combi

Greenstar FS 30CDi ErP & 42CDi ErP Regular

GREENSTAR Ri ErP + User instructions UK/IE. Wall hung RSF gas fired condensing regular appliance. For central heating systems

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

USER GUIDE LOGIC HEAT H

USER GUIDE VOGUE MAX SYSTEM

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

GREENSTAR CDi CLASSIC REGULAR ErP

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Open Vented Condensing Boilers

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Osprey 2 CFL

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

Combi Eco Elite Range. User s Guide and Important Warranty Information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

Greenstar Si Compact ErP

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

iheat 25c iheat 30c iheat 35c

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

User s Operation Instructions & Important Warranty Information

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

GB24 & GB30. User Manual

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Alpha CombiMax 350 and 600

USER INSTRUCTION MANUAL. Autofill Water Boiler

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Grant Vortex. Boiler House Floor Standing Condensing Oil Boiler Range User Handbook. Model shown: VTXBH3646

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

E-COMBI EVO E-SYSTEM EVO

Avanta 12v - 15v - 18v - 24v - 30v

MURELLE EV HE 25/55-30/55

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Bosch Group. 24CDi OF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS

Mikrofill Ethos Condensing combination boiler

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

FITTING, OPERATION, INSTALLATION & SERVICING INSTRUCTIONS

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

These instructions are to be left with the user

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Alpha FlowSmart 25 and 50

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

kw Btu/h Metres Feet l/min. Gal/min C C

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

T550i power shower pump Installation and operating instructions

Transcription:

Vote for your Installer of the year at www.worcester-bosch.co.uk HEATSLAVE 12/14, 15/19, 20/25, 26/32 FLOOR-STANDING OIL-FIRED COMBINATION BOILERS FOR CENTRAL HEATING AND MAINS-FED DOMESTIC HOT WATER USER INSTRUCTIONS & CUSTOMER CARE GUIDE

EXCELLENCE COMES AS STANDARD Thank you for purchasing a Heatslave oil-fired central heating boiler. Heatslave oil boilers are made by Worcester and the strictest quality control standards ever demanded are applied throughout every stage of production. Indeed, Worcester, part of the Bosch Group have led the field in innovative boiler design and performance for more than 40 years. The result is that your new Heatslave boiler offers you the very best of everything quality, efficiency, economical running costs, proven reliability and value for money. What s more, you also have the assurance of our nononsense 1 year parts and labour guarantee. CONTENTS Page No. General Information... 3 Your Heatslave system controls... 5 How to operate your boiler... 8 Fault Finding Guide... 12 Maintenance and Extended Warranty... 13 The Heatslave Guarantee... 15 2

GENERAL INFORMATION To ensure you get the very best from your new Worcester Heatslave oil boiler, please read these notes and instructions carefully. The Worcester Heatslave is a combination boiler which provides mains-fed domestic hot water and full central heating. It utilises a Heatslave tank and a heat exchanger, which ensure that whenever a tap is turned on there is an instantaneous output of hot water. The boilers control system gives priority to the domestic hot water supply. This means that during hot water draw-off and Heatslave tank recovery periods, the total output of the boiler is directed to the Heatslave tank. If the central heating is switched on during this period, the circulation of hot water to the radiators will be temporarily interrupted but will resume as soon as the Heatslave tank has been recharged to the temperature set on the hot water control thermostat. SERIAL NUMBER Your boiler serial number and model number should always be quoted in any contact with Worcester. This will help identify spare parts and also avoid confusion and delays during any service call-out. You will find these numbers on a label on top of the electrical control box cover plate, and access can be gained by removing the top panel of the boiler casing. FUEL Your Worcester Heatslave pressure jet boiler is set to burn 28- second kerosene fuel. Some models can be converted to burn 35- second gas oil. If this conversion has been made your installer will inform you. PLEASE NOTE: Appliances fitted with a low-level discharge flue MUST NOT be used with 35-second gas oil. OPEN-FLUED BOILERS Your installer will create airways (in walls or doors) to ensure an adequate supply of fresh air to the boiler for combustion. Do not block these airways, and never hang clothes or other combustible materials over the boiler or against the flue pipe. Never place anything on top of the boiler. 3

ROOM-SEALED BALANCED FLUE BOILERS Air for this type of boiler is supplied via the balanced flue terminal, and no other air supply is required, except for ventilation if the boiler is installed in a cupboard or compartment. ELECTRICAL SUPPLY The mains supply for your Heatslave boiler is 230/240 volts AC-50Hz. The internal fuse is a 3- amp, 20mm quick-blow fuse. ELECTRICAL CONNECTION A mains cable should be connected to a double pole isolator with a contact separation of 3 mm on all poles and supplying the appliance and controls only. Your boiler must be earthed and protected by a 5-amp fuse. ROUTINE MAINTENANCE It is essential that your boiler is installed and serviced by a competent heating engineer, and Worcester will be pleased to arrange regular servicing and a comprehensive maintenance contract. Alternatively, the Oil Firing Technical Association for the petroleum industry (OFTEC) will gladly advise you of engineers trained by and registered with OFTEC. Servicing should be carried out at least once a year for boilers which burn 28-second kerosene, and twice a year for boilers which burn 35-second gas oil. ADDITIONAL FITTINGS & CONTROLS When considering additional controls or fittings for your new Heatslave hot water and central heating system, please note the following: ROOM THERMOSTAT It is recommended that a mains voltage room thermostat is fitted, as this will improve your control of room temperatures. THERMOSTATIC RADIATOR VALVES Any thermostatic radiator valves fitted to your central heating system must conform to BS 2767/10. 4

SHOWERS, BIDETS, TAPS AND MIXERS Any taps and mixers used with your system must be suitable for operating at mains pressure. For a shower it is recommended that you fit a thermostatically-controlled shower valve, as this will give added safety by protecting against excessive water temperatures. Mains-fed hot and cold water can be supplied direct to an over-rim flushing bidet, subject to local water bye laws. If a loose shower head with a flexible hose is to be used over the bath, the hose must be fixed so that the head cannot fall closer than 25mm (1 inch) above the top edge of the bath, so preventing its immersion in bath water. Alternatively, the shower must incorporate or be fitted with an anti-syphonage device at the point of the flexible hose connections. HOT AND COLD FLOW The flow of water from your hot and cold taps depends on the mains water pressure, and in some homes it might not be possible to operate several taps simultaneously. To ensure an even distribution of water to all outlets in the home, you can fit individual flow regulators to the supply pipes. YOUR HEATSLAVE SYSTEM CONTROLS USER OPERATING SWITCH Your boiler facia panel is supplied with a user operating switch as standard, although this may have been replaced with the optional facia mounted electronic programmer or a remote programmer. If HOT WATER only is selected The boiler will keep the Heatslave tank at the temperature set on the hot water control thermostat. Whenever a tap or shower is turned on, the burner will ignite and water will be pumped through the water to water heat exchanger to provide hot water. 5

If HEATING and HOT WATER are selected together The central heating will operate in response to any system controls, and hot water will be supplied when a tap or shower is turned on. The Heatslave tank will be kept at the pre-set temperature, as in the HOT WATER mode. If OFF is Selected Your central heating and hot water will remain off unless there is a demand via a frost thermostat (where fitted), in which case the boiler pump, diverter valve and burner will be activated until the demand is satisfied. The burner will remain inoperative in all other circumstances. If a demand for hot water is made at a tap or shower, primary water will be pumped from the Heatslave tank through the hot water heat exchanger. This will provide a limited supply of hot water, the output depending on the amount of heat stored in the Heatslave tank. This function could prove useful during periods when it might be undesirable or uneconomical to keep the Heatslave tank constantly hot, but when there might be a demand for small quantities of hot water, such as for hand washing. Such periods could include overnight and the summer months, when the demand for hot water is lowest. In these circumstances the Heatslave tank can be charged up to maximum temperature once or twice a day as required, with the programmer in the HOT WATER mode and the hot water control thermostat set to maximum. OPTIONAL PROGRAMMER Where a Worcester facia mounted programmer has been fitted to your appliance the additional Heating only setting is available. Full installation and operation instructions are included with the programmer kit. If HEATING only is selected The boiler will operate as a conventional oil-fired boiler, giving output to the central heating circuit in response to the system controls. A demand for hot water at a tap or shower will override the central heating for as long as the hot water is drawn off, allowing any residual heat in the Heatslave tank to be utilised. 6

EXTERNAL PROGRAMMER You may opt to have a programmer sited away from the boiler, in which case your installer will provide setting and operating instructions. CENTRAL HEATING TEMPERATURE CONTROL The central heating temperature control knob on the boiler facia panel enables you to control the temperature of the water in your radiators. A low temperature is indicated by a single horizontal bar, and the control knob can be set anywhere between this and the maximum temperature, which is indicated by five horizontal bars. (As shown in Fig. 1.) Fig. 1. TEMP Low Setting PLEASE NOTE: The control knob must not be set below the first indicating bar. HOT WATER TEMPERATURE CONTROL The hot water control temperature knob on the boiler facia panel controls the temperature of the primary hot water stored in the Heatslave tank. The temperature control settings are as for the central heating control thermostat (described above). A high setting will give higher hot water temperatures and greater quantities of hot water. The temperature of your hot water can also be controlled at the tap by varying the flow rate; increasing the flow rate will decrease the temperature, and vice versa. WARNING. Care should be taken when washing your hands as the combination of low water flow rate and a high setting of the hot water control thermostat can result in very hot water at the tap. High Setting The control knob has a range of adjustment as indicated by the symbols. 7

INDICATION LIGHTS There are two indicator lights on the facia panel POWER ON and LOCKOUT. The POWER ON light shows that there is an electrical power supply to the electrical control panel. This will remain on at all times provided there is an external electrical supply and the internal fuse has not blown. The LOCKOUT light illuminates if a burner ignition failure occurs. The burner can be reset after two minutes by pressing the illuminated lockout reset button located on the burner control box. PLEASE NOTE: Do not attempt to repeatedly restart the boiler as persistent lockout indicates a fault and you should consult a service engineer. OVERHEAT THERMOSTAT Your boiler is fitted with a manual reset overheat thermostat. If the burner fails to operate and the LOCKOUT indicator light is not illuminated, check the overheat thermostat by pressing the reset button. The thermostat is located on the underside of the electrical panel and is accessible by removing the boiler casing front panel. If the problem continues after pressing the reset button, consult a service engineer. Fig. 2. Control Facia HOW TO OPERATE YOUR BOILER If your boiler is being operated for the very first time following the installation your installer should have commissioned the system as specified in the Installation Instructions. Central Heating Temperature Control Knob Mains Power Indicator Light Optional programmer location 8 Domestic Hot Water Temperature Control Knob Overheat Thermostat Reset Button Lockout Indicator Light

TO START YOUR BOILER First ensure that the oil supply is turned on. Now switch on the mains electricity and turn the hot water and central heating temperature control knobs to maximum. Set the user operating switch (or programmer) so that both HEATING & HOT WATER ARE ON. The burner should now ignite. Set the user operating switch (or programmer) to suit your own requirements, and if a room thermostat is fitted set the desired temperature. Similarly, set the hot water and central heating temperature control knobs to the desired temperature level. TO SWITCH YOUR BOILER OFF FOR SHORT PERIODS Set the programmer to OFF. TO SWITCH YOUR BOILER OFF FOR LONG PERIODS Set the user operating switch (or programmer) to OFF and switch off the mains electricity at the isolator switch. The faciamounted programmer (where fitted) will retain its settings for about four weeks, after which it will revert to the factory-set programme, but the display will disappear after approximately twelve hours. CENTRAL HEATING SYSTEM OPERATION During the first operation of the central heating system, check that all radiators are heated evenly. If the top of a radiator is at a lower temperature than the bottom, vent it by releasing air through the vent screw at the top of each radiator. Your installer should show you how to carry out this simple procedure, and give you the special key required to do it. Should you find any leaks in the system, or find that any radiator requires excessive venting, ask the installer or a service engineer to rectify the system. SEALED SYSTEM OPERATION If your boiler has been fitted to a sealed primary water system, a minimum water operating pressure must be maintained. This minimum pressure is indicated by the pre-set pointer located on the pressure gauge, which can be viewed by removing the front panel of the boiler casing. 9

If the pressure falls below this minimum level, the system must be re-pressurised using the method described by your installer. To ensure that the boiler and system are full of water and pressurised, check the pressure gauge indicator needle. Consult your installer or service engineer if the system continues to lose pressure, as this could indicate a leak. MAINS SERVICE INTERRUPTIONS In the event of mains water supply failure, no hot water will be available from the boiler. However, the central heating system will continue to operate. If the electricity supply fails, the boiler will not operate. When the supply is restored, the boiler will return to normal operation, but you should check that the programmer has maintained your required settings. LOOKING AFTER YOUR BOILER AND SYSTEM It is essential that your boiler is serviced by a competent engineer, as previously described on page 4. These notes will also be helpful in maintaining your boiler s efficiency and performance. CLEANING Use a damp cloth and a small amount of detergent to clean the boiler casing. Never use abrasive cleaners. FROST PRECAUTIONS To protect your central heating system from freezing, your installer may have fitted a mains voltage frost thermostat. If so, your boiler should only be switched OFF at the user operating switch (or programmer), otherwise the burner will not operate when there is a demand via the frost thermostat. If your boiler has not been fitted with a frost thermostat and is not to be used during a long period of cold weather, the boiler and the system should be drained to prevent freezing. If your boiler is not to be used during short periods of cold weather, leave it on a low temperature setting. 10

HARD-WATER AREAS If you live in an area where the mains water is exceptionally hard, it is recommended that an in-line scale inhibitor is used in your boiler and system, in strict accordance with the requirements of your local water company and bye laws. An isolating valve, to facilitate servicing, should also be incorporated. Water hardness can be determined by reference to your local water company. Further information can be obtained from Worcester. FAULTS & BREAKDOWNS Many calls made to our Contact Centre reporting boiler faults or breakdowns prove to be false alarms, as there is often a simple explanation for the apparent malfunction. So, to help you save time and money - not to mention frustration and inconvenience - a quick-reference fault finder is included on page 12. If, after checking through the points suggested, there is still a fault, you should call our Contact Centre. Arrangements will be made for an engineer to call as soon as possible. CALL-OUT CHARGES All of Worcesters field service engineers are factory trained. If you request a visit from an engineer and your boiler has been installed within the last 24 months, no charge will be made for parts and/or labour providing: The appliance was commissioned correctly on installation and a completed Guarantee Registration Card returned to Worcester. An appliance fault is found and the appliance has been installed within the past 24 months, provided that the first annual service has been carried out on a boiler which is more than 12 months old. Reasonable evidence of this must be supplied on request. A call-out charge will be made where: The appliance has been installed for over 24 months 11

The appliance has been installed for more than 1 year but less than 2 years and has not had a first annual service by an approved company. OR Our Field Service Engineer finds no fault with the appliance (see note). OR The cause of breakdown is misuse or with other parts of your plumbing/heating system, or with equipment not supplied by Worcester. NOTE: Invoices for attendance and/or repair work carried out on your Worcester Heatslave boiler by any third party will not be accepted. FAULT FINDER If your boiler is not operating, it is suggested that you go through the following simple checks before either calling your installer or Worcester. SYMPTOM POSSIBLE CAUSE CHECK/REMEDY Red Power On There is no electricity supply Power supply is switched on. Indicator is not to the boiler. Check the fuse has not blown. illuminated. Boiler internal fuse has blown. Check Fuse F1 on boiler PCB Board. Power On Indicator There is no demand Check boiler thermostat is set on illuminated only. requiring the boiler to operate. medium to high. Boiler overheat thermostat has operated. Check operating switch (or programmer) is set for hot water and/or central heating and re-set if necessary. (If programmer is fitted see operating instructions). If the boiler is programmed for central heating, check the room thermostat is turned on. Check the pressure gauge indicator needle and re-pressurise if necessary. (See section Sealed System Operation.) Press overheat thermostat reset button. (See section Overheat Thermostat.) Power On & Lockout The boiler has attempted Check the level in your oil tank & indicators both to ignite, but has gone to replenish if necessary. illuminated. lockout. Remove the appliance front cover and depress the lockout reset button on the burner. (See section Indication Lights.) 12

MAINTAINING YOUR BOILER S EFFICIENCY & PERFORMANCE Your new Worcester Heatslave oil-fired boiler represents a long-term investment in a reliable, high quality product. In order to realise its maximum working life, and to ensure it continues to operate at peak efficiency and performance, it is essential that your boiler receives regular, competent servicing and annual maintenance checks beyond the initial 24 month guarantee period. Regular service contracts can be arranged with your installer however, if you have difficulty making a satisfactory arrangement simply call our Contact Centre on 08457 256206 for help. If you would like to know more about Worcester s extended warranty options please tick the appropriate box on your Guarantee Registration Card. 13

CONTACT CENTRES CONTACT NUMBERS: UK Contact Centre Tel. 08457 256 206 UK Contact Centre Fax. 01905 757536 Scotland only Fax. 01506 441 687 Eire Tel: 01 494 0099 OPERATING HOURS: Mon - Fri Sat Sun 7.00am to 8.00pm 8.00am to 5.00pm 9.00am to 12.00pm Please contact our UK Contact Centre number where our friendly operators will book your call with one of our team of nationwide engineers. NOTE: Please refer to our website for our bank holiday hours. www.worcester-bosch.co.uk 14

YOUR WORCESTER HEATSLAVE GUARANTEE This appliance is guaranteed from the date of installation subject to the following conditions & exceptions. 1. The appliance is guaranteed for a period of 24 calendar months subject to the return of the guarantee card within 30 days of installation and the first 12 months service and inspection having been carried out to the satisfaction of BBT Thermotechnology UK Ltd. Please note that this service is not covered under the terms & conditions of the warranty and would therefore incur a charge. 2. That during the period of this guarantee any components of the unit which are Proved to be faulty or defective in manufacture will be exchanged or repaired Free of material charges and free of labour charges if repaired directly by BBT Thermotechnology UK Ltd. Invoices for attendance and repair of this appliance by third parties will not be accepted for payment by BBT. 3. That the householder may be asked to prove the date of installation and that the appliance was correctly commissioned. This information must then be documented in the Benchmark Gas Boiler Commissioning Checklist. 4. That any product or part thereof returned for servicing under the guarantee must be accompanied by a claim stating the model, serial number and date of installation. 5. That BBT Thermotechnology UK Ltd will not accept responsibility for damage caused by faulty installation, neglect, misuse, accidental damage or the non-observance of the instructions contained in the Installation and Users instructions leaflets. 6. That the appliance has been used only for normal domestic purposes, for which it was designed. 7. That this guarantee applies only to equipment purchased and used in mainland Great Britain. This guarantee is given in addition to all your normal statutory rights. Worcester, Bosch Group is a trading name of BBT Thermotechnology UK Ltd. 15

GUARANTEE REGISTRATION You should complete and return the postpaid Guarantee Registration Card within 30 days of purchase. The card will register you as the owner of your new Worcester Danesmoor boiler and, while this will not affect your statutory rights in any way, it will assist us to maintain an effective and efficient customer service by establishing a reference and permanent record for your boiler. FOR YOUR OWN RECORD MODEL SERIAL NUMBER (See identity label inside appliance casing) TYPE/SIZE DATE OF INSTALLATION www.worcester-bosch.co.uk Worcester, Bosch Group. Cotswold Way, Warndon, Worcester WR4 9SW. Telephone: (01905) 754624. Fax: (01905) 753130. Technical Service Helpline 08705 266241. 8 716 114 752a (11/07)