Chemistry Instrumental Analysis Lecture 4. Chem 4631

Similar documents
高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Chemistry Instrumental Analysis Lecture 14. Chem 4631

SPECTRAL INSTRUMENTATION

DURIP: Fast Oscilloscope and Detectors for Air Laser Research

Medical Lasers and Laser Safety

Laser Diagnostics and Optical Measurement Techniques

EMITTER TECHNICAL DATA

Chemistry Instrumental Analysis Lecture 29. Chem 4631

An FT-NIR Primer. NR800-A-006

Current Research Topics in Optical Sensors and Laser Diagnostics

Heat Management Methodology

Propagation loss in optical fibers (01/29/2016)

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

Gaseous detectors. 1

The George Washington University. Laser Safety Manual

Laser Safety. The George Washington University Office of Laboratory Safety Ross Hall, Suite B

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

LECTURE 11. Dr. Teresa D. Golden University of North Texas Department of Chemistry

The University of Mississippi BASIC LASER SAFETY

MSA s Guide to Selecting the Right Flame Detector for Your Application

Laser Safety Training

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

Bernd Eichler Sales Manager

Remote flammable gas detection/measuring device

Variable Temperature Microprobe Systems

Exhaust Air Plenum Heated Supply Air. Direct Impingement Convection Dryer. Heated Drum. Typical Conduction Heating System.

NYC STEM Summer Institute: Climate To Go! Infrared detection of carbon dioxide

VM-3000 Mercury Vapor Monitor

North Dakota State University Laser Safety

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

TABLE OF CONTENTS 1.0 INTRODUCTION 2.0 PURPOSE 3.0 STATEM ENT OF COMPLIANCE 4.0 SCOPE 5.0 AUTHORITY 6.0 ADMI NISTRATION

VM-3000 Mercury Vapor Monitor

Laser Distance Sensor Type M Analog-Output

The incredible power of light Photonics-based solutions from ultraviolet to infrared

02/21/2003. Laser Radiation Safety

NanoReady. Micro UV-Vis Spectrophotometer

PG 990 Atomic Absorption

Specifications Wavelength Range: 190 nm to 800 nm continuous

Laser Safety Manual March 2011

Spot on Fraunhofer IAF

Laser Safety Training

o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

April, Solid State LED Based Lighting: High Power UV Light Sources for Industrial Applications

I. American National Standards for Safe Use of Lasers - ANSI Z

VS Glow Is the Newest and Most Technically Advanced Infrared Heater that Generates Instantaneous Heat

Mercury Vapor Monitor VM-3000

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

Light fright. Improper laser use poses real safety hazards

Laser Safety Training Guide

LASER SAFETY MANUAL Office of Environmental Health & Safety April 2003

Variable Temperature Options for Optical Experiments

Radiation and Laser Safety

Nexera-i Specifications Prominence-i Specifications

Exercise 1: IR Transmission and Reception

Heat Transfer: Conduction. Heat Transfer: Conduction

Staying Safely on Target! Laser Safety. Chuck Paulausky, CHMM, LSO

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Fourth Edition HEAT TRANSFER AND CHANGE OF PHASE

UVC Detection as a Potential for Alpha Particle Induced Air Fluorescence Localisation

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Who is GBC Scientific Equipment?

Customization of Optoelectronic Detectors Part Two in a Six-Part Series

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Lasers and Laser Safety

Lasers in Veterinary Practice. Safe Use Guidelines

INFRARED HEATERS APPLICATIONS INFRARED HEATING

LEARNING SPECIAL HAZARD DETECTION TYPES

Instrumental technique (MCP detectors) - Kamalesh ( )

SHENZHEN LAMPLIC TECH CO., LTD UV LED SPOT CURING SYSTEM TECHNICAL MANUAL

Diamond Windows & MCP Detectors for Synchrotron Applications

Curing with Electric Infrared

Pyroelectric Infrared Sensor PIR

Basic Laser Safety Training

VII(b). RADIATION SAFETY LASER

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Agilent 1200 Series Fluorescence Detector

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Instructions for use by laboratory personnel. laser. safety. Pôle Maîtrise des Risques Direction de la Protection et de la Sûreté Nucléaire

Fire Detection System: An Overview

IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

CCD and CID solid-state detectors

SP-3800AA Atomic Absorption Spectrophotometer

University of North Florida Laser Safety Manual. Environmental Health and Safety Department

GC DETECTORS Reduction Gas Detector - RGD. Overview

Indium Gallium Arsenide Detectors

Measuring Stokes shift. Easy, fast and reliable

ZERO 400 IP 54 stationary mercury-vapour UV lamp. irradiation intensity must be larger than 1,000 ambient illumination of less than 20 lx.

detectors UltiMate 3000 Variable Wavelength Detectors

SUNSTAR 传感与控制 TEL: FAX: DATASHEET Lightingg Solutions 1100 Series High Stabi

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

Customized MCPs for Analytical Instruments. An MCP for every application

Developing UV LED Curing Processes for Converting Applications

Mechanism of audible sound generation during flash lamp operation. Tetsuya Kitagawa, Mitsuru Ikeuchi, Yukihiro Morimoto, Fumihiko Oda

Mark Farries. Gooch & Housego

E11 Tests of trace gas concentration multicomponent. monitoring system

Transcription:

Chemistry 4631 Instrumental Analysis Lecture 4

Atomic Spectroscopy

Atomic Spectroscopy

UV to IR Optical spectroscopy are based on: absorption fluorescence phosphorescence scattering emission chemiluminescence

UV to IR Basic components of spectroscopic instruments: stable source of radiant energy transparent container to hold sample device to isolate selected region of the spectrum for measurement detector to convert radiant energy to a signal signal processor and readout

Optical Glass - 335-2500 nm Special Optical Glass 320-2500 nm Quartz (Infrared) 220-3800 nm Quartz (Far-UV) 170-2700 nm

Sources of Radiation Continuum Sources Used for absorption and fluorescence spectroscopy. For UV, most common is the deuterium lamp. For vis, most common is the tungsten filament. For IR, most common are heated inert solids.

Sources of Radiation Continuum Sources Deuterium and Hydrogen Lamps Give continuum spectrum in UV region by electrical excitation of D 2 or H 2 to form an excited molecular species. The excited molecular species dissociates to two atomic species and a photon.

Deuterium and Hydrogen Lamps D 2 + E e D 2 * D' + D" + hu E e electrical energy absorbed by molecule.

Deuterium and Hydrogen Lamps The lamp has a heated filament which forms an arc with a metal electrode. Filament provides a direct current when 40 V is applied. Spectrum range 160 375 nm Must use quartz windows with these lamps since glass absorbs strongly at wavelengths below 350 nm.

Deuterium and Hydrogen Lamps

Sources of Radiation Continuum Sources Tungsten Filament Lamp Source for vis and near IR Wavelength range 350 2500 nm

Tungsten/halogen lamps Add a small amount of iodine Lifetime 2x of regular lamp I 2 reacts with gaseous W to form WI 2 WI 2 strikes the filament WI 2 decomposes W redeposits on the filament.

Tungsten/halogen lamps

Sources of Radiation Continuum Sources Xenon Arc Lamps Produces intense radiation by passing current through gaseous Xe. Gives continuum spectrum between 200-1000 nm

Xenon and Mercury Arc Lamps

Xenon and Mercury Arc Lamps The anode and cathode are made of tungsten and sealed in a clear quartz envelope. Arc lamps are filled with either rare gas at several atmospheres pressure, or a little rare gas and an exact amount of mercury. Xenon lamp better for scanning applications. Hg lamp better for a line source (discrete).

Sources of Radiation Continuum Sources Xenon Arc Lamps

Sources of Radiation Line Sources Emit a few discrete lines. Hg and Na vapor lamps have a few sharp lines in the UV and vis region.

Line Sources

Laser Sources Light Amplification by Stimulated Emission of Radiation High Intensities Narrow Bandwidths Coherent Outputs

Laser Sources in UV, vis, and IR Used for high resolution spectroscopy kinetic studies routine analysis

Laser Sources

Laser Sources Lasing Medium: solid crystal (ruby) semiconductor (gallium arsenide) solution (organic dye) gas (argon or krypton)

Laser Sources Lasing Medium must be activated or pumped using radiation from an external source. This can be a few photons of the correct energy to trigger a cascade of photons of the same energy. Or could be an electrical discharge into a gas.

Laser Sources Once the cascade begins the laser functions as a resonator, passing the radiation back and forth through the medium using mirrors. This generates even more photons amplification.

Laser Sources

Laser Sources Nonparallel radiation dissipates out the top and bottom of the medium and parallel or coherent radiation is left.

Laser Sources

Laser Sources Processes include: pumping spontaneous emission (fluorescence) stimulated emission adsorption population inversion

Read Chapter 6 Assignment HW1: Ch. 1: 11 and Appendix 1: 1, 2, 10, and 12 (extra credit) (Due Today) HW2: Ch. 6: 2-12, 14, 15, 18, 19 (extra credit) (Due 1-28-19) Read Chapter 7