VÄRMEBARONEN IS A UNIQUE COMPANY IN THE ENERGY INDUSTRY

Similar documents
VEDOLUX ROBUST GREEN WOOD-FIRED BOILERS

Distributed*and*installed*in*the*UK*by*

Wood pellets economical and environmentally friendly. Wood pellet heating

Combine. accumulators AQUALUX ACKTANK. Combine heat sources for cheap heating

Wood firing at its simplest

Pellet heating. Boilers & Burners.

Wood-firing at its simplest


Installation, operation and care. Pellmax UB. Burner not included Replaces:

Accumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU

Installation and maintenance Vedolux 450

Product catalogue. Our range of products for bungalows

Installation, operation and care Firewood boiler Vedolux 40 UB

Installation and maintenance Vedolux 350

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Solar heating. Free heat from the sun!

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

Installation and maintenance Viking Bio 35 - pellet burner

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

EKO Line Pellet Boiler Wood Pellet Storage Solutions And Pellet Dosage Systems

English. Heating with logs & wood pellets 20-40

Eco Angus Wood Pellet Boilers

Installation, operation and maintenance. Accumulator tank. Acc-tank 500 CU. Acc-tank 500 UB ver: Supersedes:

Biomass. Biomass solid fuel boiler range

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

HERZ ECO-Line Heating with logs or wood pellets

Easyfire Standalone biomass pellet boiler

Heating with log wood

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Efficient heating that won t cost the earth

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Installation and maintenance Viking Bio 35 - pellet burner

New opportunities to heat with wood pellets

Installation, operation and maintenance. Pellet burner 18/01/2011. Replaces:

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Solid biofuel solutions

Sweden s leading air source heat pump

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

Your guide to. Biomass Heating Systems

Heating with wood chips

Installation, operation and care. Pellet burner Replaces:

english GUNTAMATIC BIoMAss BoIler HeATING range

Log fired heating system

Heating with pellets kw

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

English. Heating with logs & wood pellets 20-40

Fully-automatic Wood Pellet central heating

Pioneers of heating with biomasses

Heating with wood pellets kw

S3 Turbo Firewood boiler. S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS.

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

INSTALLATION AND OPERATING INSTRUCTIONS

Flexible heating system without limits.

PELLET BURNER PV 350

BIOMASS BOILER DUAL THERM

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW. Pellet Boilers. Future of Ecological Heating

Biomass Pellet Boilers

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 1000 VEDEX 1000 M10527 LEK

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

modern heating devices

P4 Pellet. Pellet boiler. P4 Pellet.

Installation and maintenance Pellet burner

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

P4 Pellet. Pellet boiler. P4 Pellet.

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

Forward-looking and energy effi cient Biomass heating

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

Combined boiler. for solid fuel and pellets

WOOD FIRES 15 YEARS. LIMITED W A R R A N T Y

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

JÄSPI Solid Fuel Boiler

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Sirius FS. Working towards a cleaner future

PELLET STOVES & INSERTS. PELLET STOVES & INSERTS

Light oil / kerosene burner

USER MANUAL 9kW LILLY PELLET STOVE

NEW. Thermotank Quadroline. living full of energy. The new generation of plastic storage tanks. Energy systems

From a renowned company

S3 Turbo Firewood boiler. S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS.

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Sauna Heater. Installation and Manual

ENERGY TOP. Condensing boiler solutions

Clear Installation guide

WHE 2.24 / WHE 2.24 FF

Cleaner & More Efficient Heating Than Ever Before

KWB CLASSICFIRE Log-wood and pellet heating system 18/28 kw

Installation instruction

The finest fruit processing

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

AIEA Presentation. Wood pellets heating systems.

User friendly, compact, economical and safe

Transcription:

biomass range P1

P2

VÄRMEBARONEN IS A NIQE COMPANY IN THE ENERGY INDSTRY Founded in 1975, just north of Kristianstad in the south of Sweden, Värmebaronen, offers a broad range of products and with a solid reputation for quality. The company s positive development has been rewarded with awards such as Dagens Industri s Gasell Prize, which is given to companies that demonstrate strong growth and profitability. Värmebaronen has also won awards for efforts in developing and manufacturing eco-friendly products. The company s philosophy is not to be the biggest in the market but to always strive to be the best. We manufacture all of our products in our purpose built factory so that you can rest assured that when you buy a Varmebaronen product you are getting the finest Swedish engineering. Every single product is quality tested at every stage of manufacture to ensure that only the very best product leaves the factory. Our latest endeavour is to service the K market in partnership with AC Gold to bring our fantastic range of biomass boilers to heat properties just like yours. VÄRMEBARONEN BIOMASS RANGE MAINTENANCE-FRIENDLY AND EFFICIENT BOILERS MEAN CARBON DIOXIDE-NETRAL HEATING Wood is a biofuel which, when used in the right wood-fired boiler and fired in the right way, has minimal environmental impact. The carbon dioxide that is released during combustion is the same amount of carbon dioxide that the wood gives off when it dies and decomposes. NATRALLY, ALL OR WOOD-FIRED BOILERS ARE ENVIRONMENTALLY APPROVED All Värmebaronen s products intended for biofuel have been tested by the Technical Research Institute of Sweden (SP). Because they are so easy to maintain, it is easy to maintain the excellent characteristics. This saves both wood and the environment. P3

BENEFITS OF PELLET FEL ENVIRONMENTALLY FRIENDLY AND ECONOMICAL Wood pellets are a biofuel manufactured from sawdust. When you use wood pellets as a fuel, the substances released into the atmosphere are re-absorbed by growing plants and trees, creating a natural cycle unlike burning fossil fuels or generating electricity from oil or coal. The net emissions of carbon dioxide are zero. BENEFITS OF PELLET FEL Renewable energy source Minimal environmental impact Low price Easy to handle Available in sacks or as bulk loads Wide choice of supplier Locally produced Reduced electricity consumption An easy way to switch to biofuels Can be used in existing boilers LIVING WITH PELLETS Pellets are convenient. If you have space to chose a bulk store everything takes place automatically. The pellets are delivered by lorry so you don t need to handle them at all. If a more compact solution is needed smaller hoopers lasting 1-2 weeks which you fill with bags of pellets are the perfect solution. The pellet store 200 teamed with a pellmax is only 1 meter wide. This compact and versatile duo can fit into small spaces where required or be linked to a lager hopper for higher demand. LOW MAINTENENCE AND RELIABLE Värmebaronen has been Sweden s biggest supplier of domestic pellet boilers for years. Our range of boilers includes models designed for all needs. They are all low maintenence with automatic loading, have the same sturdy combustion chamber, developed for our reliable firewood boilers and a large ash bin means there is no need for constant emptying. P

PELLMAX PELLET BOILERS PELLMAX B PELLMAX C PELLMAX VX A TRIO FOR ALL HOME OWNERS VIKING BIO PELLET BRNERS VIKING BIO 200 VIKING BIO 35 MODERN PELLET FIRING P5

PELLMAX C HEATING WITH OTDOOR TEMPERATRE COMPENSATION The top-of-the-range pellet boiler. The C model has a digital control system for maximum efficiency and comfort. Smart functions can reduce running costs compared to other boilers on the market. The heating control system compensates for the outdoor temperature, ensuring that the house always gets enough heat even if the temperature changes quickly outside. The boiler stops producing heat in the summer, but runs all the vital functions every day so that everything runs smoothly when autumn arrives. Together, these functions will save you money every day. WOOD PELLETS & ELECTRICITY Water heater Dimensions: W:570 H:150 D:75 Wood pellets: 25 kw Electricity: 9 kw RSK 621 05 66 IN BILT DOMESTIC HOT WATER TANK The Pellmax C has a sturdy copper-lined water heater, serving up plenty of hot water and great for hard water areas. MAXIMM ECONOMY All these functions turn the Pellmax C into a real money saver. Outdoor temperature compensation plus intelligent control of the pellet burner will save you money while delivering maximum comfort. PELLMAX VX HOT WATER WITH HEAT EXCHANGER The Pellmax VX is a solid and compact pellet boiler, using a traditional control system with mechanical thermostats which switch on the pellet burner dependant on temperature. The control panel shows which energy source is being used. The heat exchanger produces hot water as it is needed. WOOD PELLETS & ELECTRICITY Heat exchanger Dimensions: W:570 H:1370 D:75 Wood pellets: 25 kw Electricity: 9 kw RSK 621 05 67 The water is heated as it passes through the heat exchanger on the way to the tap. The Pellmax VX is low in height, and is a good choice for low ceilings. All connections are easy to access. PELLMAX B COMPACT AND FLEXIBLE Whatever combination of heating you have, the Pellmax B pellet unit will complement it perfectly. All you need is a water-based heating system and a thermal store/accumulator tank. The B model is a heat source that works perfectly with solar collectors and heat pumps.the solar collector can heat the water and the building in spring, summer and autumn. The wood pellets then take over in winter.. The pellemax B is only 95 cm tall, and easy to find space for. PELLET NIT (No hot water) Dimensions: W:575 H:955 D:725 Wood pellets: 20 kw RSK 621 05 6 P6

VIKING BIO 200 MODERN BRNER MINIMM MAINTENANCE Viking Bio 200 is a modern auger-fed pellet burner. It operates automatically meaning minimum maintenance and maximum convenience. All the materials are carefully selected. For example, the new digital display, automatic ash removal and fuel hot parts are made of temperature resistant materials. The burner meets Europe s strictest environmental requirements with low CO emissions and minimum dust content. Tested by SP, the Technical Research Institute of Sweden, to EN 15270, Viking Bio 200 belongs to class 5, which is the highest class available. ATOMATIC ASH REMOVAL Ash removal at adjustable intervals, makes it virtually maintenance-free. In pellet boilers with spacious combustion chambers such as Värmebaronen's Pellmax series, the system can be operated for very long periods without maintenance. The rods push ash and soot out of the burner. In idle mode, they are withdrawn and well protected. The display can be used to set how often ash is to be removed. After ash removal the rods withdraw and are protected against any negative impact the firing might have. The rods run freely, independently of each other, and there is no risk of them getting stuck or making any noise. INFORMATIVE DISPLAY The informative display shows clearly what is going on and guides you through the entire operation. The display also gives the burner a number of other advantages such as: Memory Recall for troubleshooting, Reminders to clean the system and History of usage VIKING BIO 35 IF YO NEED MORE POWER For several years, there has been large demand for a bigger Viking Bio Pellet Burner. A pellet burner with tried and tested technology, the introduction of the Viking Bio 35 offers users a great alternative to heat larger properties using pellets. This simple, user-friendly class burner is a great solution provider and offers peace of mind in terms of relaibuility and quality. P7

PELLMAX C RSK 621 05 66 Height 150 mm excl. flue pipe Width 570 mm excl. drain valve Depth 75 mm Pellmax C Ash bin 25 litres m, Chimney requirements Height 150 Ø min.100 mm excl. mm, flue height pipe min. 2m, draught max. 15 Pa Width 570 mm excl. drain valve Smoke outlet Depth to the rear 75 mm Output 25 kw Ash pellets bin 25 litres Chimney requirements min.100 mm, height min.2 m, Output 9 kw electricity draught max.15 Pa 59 Weight 300 kgsmoke outlet to the rear Water heater 100 Output litres 25 kw pellets Output 9 kw electricity Weight 300 kg ACCESSORIES Water INCLDED heater 100 litres 59 289 289 1629 1629 151 151 298 12 12 Automatic Accessories shunt valve included and outdoor temperature sensor Automatic shunt valve and outdoor temperature sensor Angled flue pipe with lockable draught regulator with lockable draught regulator Cleaning tool with bracket Cleaning tool with bracket Electronic flue gas thermometer Drain valve Drain valve Load guard Load including guard transformers including transformers 75 75 298 573 25 573 25 PELLMAX VX RSK 621 05 67 Pellmax VX Height 1370 mm excl. flue pipe Width 570 mm excl. drain valve Height 1370 mm excl. flue pipe Depth 75 mm Width 570 mm excl. drain valve Ash bin 25 litres Depth 75 mm Chimney requirements Ash bin 25 Ø litres min.100 mm, height min. 2m, draught max.15 Chimney Parequirements min.100 mm, height min. 2 m, draught max.15 Pa Smoke outlet to the rear Smoke outlet to the rear Output 25 kw Output pellets 25 Output kw pellets 9 kw electricity Weight 275 kgoutput 9 kw electricity Weight 275 kg 59 59 289 289 155 155 75 1368 1368 28 12 12 ACCESSORIES Accessories INCLDED included Angled flue pipe with lockable with lockable draught draught regulator regulator Cleaning tool Cleaning with bracket tool with bracket Drain valve Drain valve Load guard including transformers Load guard including transformers Dirt filter for heat exchanger Allowing for printing errors or errors on proofs P8 75 28 573 25 573 25

PELLMAX B Viking Pellmax PRO B RSK 621 05 6 Height 955 mm excl. flue pipe Width 575 mm excl. drain valve Depth Height 730 mm 955 mm excl. flue pipe Width 575 mm excl. drain valve Ash bin Depth 25 litres 730 mm Chimney Ash bin requirements 25 litres Ø min.100 mm, height min. Chimney 2m, requirements min.100 mm, height min. 2 m, draught draught max.15 max.15 Pa Pa Smoke outlet to the rear Smoke outlet to the rear Output 20 kw wood pellets Output Weight 20 kw 210 wood kgpellets Weight 210 kg Accessories Bakvy included with lockable draught ACCESSORIES INCLDED regulator Angled flue pipe with lockable draught Cleaning tool with bracket regulator Drain valve Cleaning tool with bracket Drain valve LEVERANSOM FATTNING Oljefi lter (20 micrometer ) Vakuummätar e Oljeslang (2 st ) Elkabel med europakontakt Insex nyckel TILLBEHÖ R Drifttidsmätar e Typ RSKn r V ikt Effekt (kw ) E ff.omr Munstycke (kg) 90% Vgrad (kg/h) vid leverans V iking Pro 27 639 07 55 9 17-27 1, -2,3 0,50/60 S V iking Pro 8 639 07 56 9 26-8 2,2 -,1 0,85/60 S V iking Pro 77 639 07 57 9 8-77,0-6,6 1,25/60 S V iking Pro 27L 639 07 59 9,5 17-27 1,-2,3 0,50/60 S Viking Pro 27L har förlängt brännrör, 190 mm jämfört med normala 90mm. VIKING BIO Viking BIO 59 Sidovy PRODCT LEVERANSOM CONTENTS FATTNING Viking Viking BIOBI O European Power Elkabel cable plug me with d European plugeuropakontakt Rökgaste Fluethermometer Askrak rake Ash a Insex key Hexnyckel SkScrewdriver ruvmejsel Type / RSK no. Output (kw) Combustion Required Voltage External dimensions of boiler (mm)weight (kg) Typ / RSK-n r Effekt (kw ) efficiency Förbrännings- Rek. draught drag * * E lspänning H uvudmått utanför pannan(mm) V i kt verkningsgrad Höjd Bredd DjuFlue p Längd gas thermometer Height Width Depth Length (kg) Viking BIO O 15-20 92% 5-10 5-10 Pa Pa 230 V 230 V 20 208 8 216 216 296 296 16 16 Allan key 639 07 6 Feed Matarskruv auger 1 500 1 50011 11 639 07 7 Feed Matarskruv auger 2 500 2 50020 20 639 07 8 Fuel Bränslerekommendationer: recommendations: Wood Träpellets, SS 18 71 20 Group Grupp 1, made tillverkade of sawdust, av sågspån, diameter diameter 8 mm, 8 mm, max. längd length max. 32 32 mm. mm. *Draught *Motdragslucka regulator skall must vara be fitted. monterad. Complete Komplett paket package Viking Viking BIO + matningsskruv BIO + feed auger 1,5 m RSK 1.5 m 639 RSK 07 6. 639 Komplett 07 6. Complete paket Viking package BIO + matningsskruv Viking BIO 2,5 + feed m RSK auger 639 07 2.565. m RSK 639 07 65. Allowing for printing errors or errors on proofs 1037 956 726 573 319 PRODCT CONTENTS VIKING BIO 35 Power cable with Flue gas thermometer Ash rake Allan key PRODCT CONTENTS LEVERANSOM FATTNING Feed auger Mata rsk ruv m pellet 1 hose 1 m pelletsslan g clips Hose Slangklämmo r Chain hanger pphängningskedja Hook hanger pphängningskrok PRODCT CONTENTS VIKING BIO 200 Power cable with European plug 83 25 P9 19

LOG BOILERS LARGE RANGE Värmebaronen has one of Scandinavia s largest range of wood-fired boilers. Our range of products offers models to suit all requirements. Common to them all is the high level of quality, the relaiability and the ease by which maintenance can be carried out. This results in a hassle free installation, an ongoing high degree of security and a happy End ser. VEDOLX LAMBDA 350, 50, 650 VEDOLX 30, 37 & 55 WOOD-FIRED BOILERS WITH A SCTION FAN THE CHEAPEST WAY OF HEATING YOR HOME Log wood is undoubtedly the cheapest way of heating your home. If you have your own source of wood or someone with a source of wood that you can help out, you can get free wood for little effort. Modern machinery enables your heating needs for the whole year to be met in just a few hours. It is common to get together with other wood-fired boiler owners and rent or buy machines together. For ultimate convenience, buy ready-chopped seasoned wood. Wood is still the cheapest method of heating. LOW MAINTENANCE COSTS Insurance companies regularly carry out surveys of the durability and reliability of heating boilers. Värmebaronen consistently comes out well in all these surveys. Careful material selection and many years of experience have resulted in robust products without any irritating minor faults. As in all wood-fired boilers, ceramic is a consumable item. In our boilers, the ceramic consists of a number of components and is cheap and easy to replace when necessary. A benefit that saves money. The simple but effective design of all our boilers mean that not only are they easy to operate and maintain but that any ongoing costs are lower. ALWAYS MAINTAIN EFFICIENCY The easy clean design of our boilers makes cleaning quick, maximising the boilers efficiency. The provision of a cleaning tool further enables the End ser the flexability to clean the system at any interval keeping the boiler at a high level of operating efficency at all times. P10

VEDOLX LAMBDA AWARD WINNING DESIGN FOR THE FTRE AND FOR THE ENVIRONMENT Vedolux 350, 50 and 650 all have Lambda control. Its timeless design has gained the award-winning Vedolux range a great deal of attention worldwide. But the Vedolux is not just a delight for the eye. Tests at SP, the Technical Research Institute of Sweden, and the German TÜV show that both the efficiency and environmental values of Vedolux boilers are in a class of their own. Vedolux Lambda holds the prestigious Design Plus award for innovative design, high efficiency, unique environmental values and quality in a class of its own. The design and construction of the boilers produce maximum efficiency and ensure that the wood lasts a long time with long intervals between firings. Vedolux is a genuine quality product in all respects. The information display tells you what is going on and the robust design means that you can rely on you Vedolux for many happy years to come. 93% EFFICIENCY: ENVIRONMENTAL CLASS 5 BEST CLASS ACCORDING TO STANDARD 303-5:2012. VEDOLX FAN ASSISTED Vedolux 30, 37 & 55 are all natural ventilation boilers with a firebox depth of no less than 57cm, with a good margin built-in for 50cm wood. Ceramic firebox with reverse combustion and solid and reliable hatches which last the lifetime of the boiler. The removable pellet hatch on the firebox makes it easy to fit the pellet burner at any stage. Thanks to the integrated fans, the Vedolux 30 and Vedolux 37 have some of the least demanding chimney requirements on the market. If you have a chimney with low suction, these boilers are an excellent choice. The fan is started with a single press of a button when you start firing. When the fire goes out, the fan will stop automatically. This is important to ensure that the boiler does not cool down, as this would reduce its efficiency. The fan also eliminates the risk of drawing smoke into the house. With a Värmebaronen system you will always have an even temperature in the house. The specially designed Aqualux tanks provide plenty of hot water and a future-proof system which can be connected to other heat sources such as solar panels, pellets or heat pumps. You will also be heating your house the environmentally friendly way! P11

This is how a good wood-fired boiler should be constructed Simple control panel. Cooling coil Flue is included in the delivery. sing the soot brush, the boiler can be swept from a single hatch. Good for your back and your knees! Hatches which remain tight throughout the lifetime of the boiler. Solid handles. sing the ash rake, you drag the ash and soot down into the ash box. The ash is then stored safely in the ash box. Ready-fitted suction fan. Soft rounded tubes without awkward corners makes the boiler easy to sweep. Spacious combustion chamber, takes 50cm wood. Fast ignition using the LPG igniter supplied. Made in Sweden of course! P12

ACCESSORIES ACK VA VARM Automatic hot tap water unit Complete unit for production of hot water. Connected to an accu-mulator tank or a heating boiler. RSK 652 5 91, Part No. 2952Flue Stand Vedolux 30 Art No. 2962 Stand Vedolux 37 Art No. 2960 LADDOMAT CONTROL 3 Part No. 2912 Automatic charger for boilers without hot water heater LADDOMAT CONTROL 11 Part No. 2923 Automatic charger for boilers with hot water heater FLE EXTENSION Part No. 2907 Black lacquered steel tube 1.0 metreflue FLE BACK/P Part No. 292 Vedolux 30/37 MODIFICATION KIT SMALL WOOD HATCH Part No. 3322 For pellet burners MODIFICATION KIT LARGE WOOD HATCH Part No. 3321 For pellet burners FLE DOWN/P Part No. 2909 (Contact chimney-sweep before downward installation) Inclusive of soot hatch SHNT PACK Part No. 2918 Aqualux Teknik PELLET HATCH CTC 1100/1200/2200RSK 621 05 57 Fits the Viking Bio. Complete kit with temperature sensor, spacer and hatch. (Outer burner tube not included). ATTACHMENT FOR EXTERNAL CONTROL VB product no.: 2956 Controls the Pellmax B in combination with a heat pump/solar collectors. BRNER HATCH for Viking Bio, hung on the left.vb product no.: 90280 Pellmax BVB product no.: 90283 Pellmax C and VXBurner BOILER TEMPERATRE SENSOR RSK 621 05 58 Controls the Viking Bio in boilers with heat exchangers or in firewood systems with accumulator tanks. 16 between on and off. Length 2.5m. INSTALLATION PLATE RSK 621 05 59 Plate, 300 x 300 x 3 mm, with predrilled holes to fit the Viking Bio. SPACER Viking Bio RSK 621 05 60 To extend the Viking Bio 105 mm from the hatch. sed if the combustion chamber is short or the hatches are narrow. Fits directly onto Värmebaronen firewood hatches. Ø 200 mm connection. AIR SEPARATOR Venting valve VALVE PACK Part No. 2927 Aqualux Teknik This is not an exhaustive list of accessories. For full list of accessories/replaceable parts please contact your dealer. P13

Vedolux 30 A 133 166 3 A 210 15 20 1 6 188 +20-0 2 21 33 +20-0 1167 1510 +20-0 1637 +20-0 115 +20-0 21 868 1265 5 5 181 876 89 5 95 +20-0 1209 Minimum distance 200mm between the rear of the boiler and the wall! Vedolux 30 Art No. 2206 Weight empty 290 kg 390 kg Volume 100 litres Design pressure 1.5 bar Max. operating temperature 110 C Power output wood: nominal 30, max. 33 kw pellet 0 kw Hearth volume 90 litres depth 550 mm Log length 500 mm Log hatch w x h 300 x 26 mm Chimney requirements height 3,5 m Ø 100 mm suction -10 / -20 Pa Voltage 230V~, 50Hz Fan 50 W Enclosure class P 21 1. Hot water outlet, riser, G32 int. 2. Hot water outlet, return, G32 int. 3. Flue, standard.. Connections for cooling coils,ø15mm C. 5. Lift, Expansion, Safety connection, G25 int. 6. Suction fan 20. Flue p, accessory. Art No. 292 21. Stand, accessory. Complete delivery Sweeping tool with bracket LPG igniter (bottle excluded) Flue gas thermometer Drainage valve Electrical wiring Accessories Flue Back/p (see sketch) Stand Art No. 2962 Pellet hatch kitart No. 2970 P1 No liability can be accepted for any printing or typographical errors

Vedolux 37 16 133 166 3 211 20 1 6 19 133 1536 +20, -0 2 21 327 +20, -0 1232 1559 +20, -0 1692 +20, -0 1209 +20, -0 930 868 1310 870 5 5 181 531 97 +20, -0 5 1202 Minimum distance 200mm between the rear of the boiler and the wall! Vedolux 37 Art No. 2202 Weight empty 320 kg 0 kg Volume 120 litres Design pressure 1.5 bar Max. operating temperature 110 C Power output wood: nominal 37, max. 2 kw pellet 2 kw Hearth volume 105 litres depth 550 mm Log length 500 mm Log hatch w x h 290 x 230 mm Chimney requirements height 3,5 m Ø 100 mm recommended chimney area: Ø15 mm suction -10 Pa Voltage 230V~, 50Hz Fan 50 W Enclosure class P 21 1. Hot water outlet, riser, G32 int. 2. Hot water outlet, return, G32 int. 3. Flue, standard.. Connections for cooling coils,ø15mm C. 5. Lift, Expansion, Safety connection, G25 int. 6. Suction fan 20. Flue p, accessory. Art No. 292 21. Stand, accessory. Complete delivery Sweeping tool with bracket LPG igniter (bottle excluded) Flue gas thermometer Drainage valve Electrical wiring Accessories Flue Back/p (see sketch) Stand RSK Art No. 2960 No liability can be accepted for any printing or typographical errors P15 22

Vedolux 350 RSK 622 20 03 160 620 1025 125 10 0/+20 23 815 152 0/+20 13 0/+20 1 8 7 7 2 2 3 5 6 Minimum distance between rear of boiler and wall is 250 mm. Flue pipe Standard 220 63 Flue pipe upwards, accessory 331 17 n17 inv. int. 175 12 535 625 626 15 15 38 127 220 205 P16

Overview 9 10 11 12 13 1 15 19 20 21 22 23 2 25 16 17 18 1. Flue pipe connection. 2. Cooling coil, DN 15. 3. Expansion connection/safety valve/rp 1.. Return from accumulator tank/drain, Rp 1 1/. 5. Connection, sensor for thermal valve (STW), Rp 1/2. 6. Flow line to accumulator tank, Rp 1 1/. Can be used as lifting sleeve. 7. Adjustable foot bolts. 8. Drain, Rp 1/2. 9. Boiler temperature sensor (inside electronics box). 10. Box with boiler's electronics. 11. pper flue gas tubes,, with turbulators. 12. Lower flue gas tubes,, with turbulators. 13. Resetting the max. temperature thermal relay (STB). 1. Bypass plate. 15. Air plates, detachable. 16. Wood store. 17. Grate. 18. Ceramics. 19. Rear cover plate, detachable. 20. Front cover plate, detachable. 21. Display/control panel. 22. Soot hatch. 23. Bypass damper. 2. Wood filling/soot hatch. 25. Latch, wood filling hatch. 26. Ash hatch. 27. Latch, ash hatch. 28. Opening for LPG ignition. 29. Back-pressure damper, primary. 30. Motor/damper, primary air. 31. Motor/damper, secondary air. 32. Back-pressure damper, secondary. 33. Flue gas temperature sensor. 3. O2 probe. 35. Mains connection, 230 V~. 36. Supply, 230 V~, flue gas fan. 37. Supply, 230 V~, charging pump. 38. Fan. 28 29 30 31 32 Weight empty 78 kg full of water 620 kg Water volume 10 litre Fuel: Wood length 500 mm 33 Wood store volume 100 litre depth 550 mm Filling hatch w x h 350 x 265 mm Power nominal 35.8 kw Chimney requirements height 5 m draught -0.15 mbar diameter 150 mm Accumulator volume min. 1500 litre Emissions - comply with EN-standard 303-5:2012. 3 35 36 37 38 26 27 P17

Vedolux 50 RSK 622 20 0 1652-0/+20 1633-0/+20 160 1639-0/+20 619 1025 1 233 8 7 7 2 2 3 815 5 6 Flue pipe Standard Flue pipe upwards, accessory 177.8 n177,8 3 20 70 125 Minimum distance between rear of boiler and wall is 250 mm. 220 63 175 12 535 625 626 257 285.5 285,5 P18 Subject to printing and proofreading errors

Overview 9 10 11 19 20 21 22 12 23 13 1 15 2 25 16 17 18 1. Flue pipe connection. 2. Cooling coil, DN 15. 3. Expansion connection/safety valve/rp 1.. Return from accumulator tank/drain, Rp 1 1/. 5. Connection, sensor for thermal valve (STW), Rp 1/2. 6. Flow line to accumulator tank, Rp 1 1/. Can be used as lifting sleeve. 7. Adjustable foot bolts. 8. Drain, Rp 1/2. 9. Boiler temperature sensor (inside electronics box). 10. Box with boiler's electronics. 11. pper flue gas tubes,, with turbulators. 12. Lower flue gas tubes,, with turbulators. 13. Resetting the max. temperature thermal relay (STB). 1. Bypass plate. 15. Air plates, detachable. 16. Wood store. 17. Grate. 18. Ceramics. 19. Rear cover plate, detachable. 20. Front cover plate, detachable. 21. Display/control panel. 22. Soot hatch. 23. Bypass damper. 2. Wood filling/soot hatch. 25. Latch, wood filling hatch. 26. Ash hatch. 27. Latch, ash hatch. 28. Opening for LPG ignition. 29. Back-pressure damper, primary. 30. Motor/damper, primary air. 31. Motor/damper, secondary air. 32. Back-pressure damper, secondary. 33. Flue gas temperature sensor. 3. O2 probe. 35. Mains connection, 230 V~. 36. Supply, 230 V~, flue gas fan. 37. Supply, 230 V~, charging pump. 38. Fan. Subject to printing and proofreading errors P19 28 29 30 31 32 33 3 35 36 37 Weight empty 560 kg full of water 730 kg Water volume 170 litre Fuel: Wood length 500 mm Wood store volume 10 litre depth 550 mm Filling hatch w x h 350 x 325 mm Power nominal 7 kw Chimney requirements height 5 m draught -0.15 mbar diameter 150 mm Accumulator volume min. 3000 litre Emissions - comply with EN-standard 303-5:2012. 38 26 27

Vedolux 650 RSK 622 20 05 1800 0/+20 160 1790 0/+20 260 666 8 1025 7 7 1 2 2 81 125 3 5 6 Minimum distance between rear of boiler and wall is 250 mm. Flue pipe Standard 257 63 Flue pipe upwards, accessory 70 177.8 177,8 3 15 1 23 93 626 257 20 285.5 285,5 P20

Overview 9 10 11 12 13 1 15 19 20 21 22 23 2 25 16 17 18 1. Flue pipe connection. 2. Cooling coil, DN 15. 3. Expansion connection/safety valve/rp 1.. Return from accumulator tank/drain, Rp 1 1/. 5. Connection, sensor for thermal valve (STW), Rp 1/2. 6. Flow line to accumulator tank, Rp 1 1/. Can be used as lifting sleeve. 7. Adjustable foot bolts. 8. Drain, Rp 1/2. 9. Boiler temperature sensor (inside electronics box). 10. Box with boiler's electronics. 11. pper flue gas tubes,, with turbulators. 12. Lower flue gas tubes,, with turbulators. 13. Resetting the max. temperature thermal relay (STB). 1. Bypass plate. 15. Air plates, detachable. 16. Wood store. 17. Grate. 18. Ceramics. 19. Rear cover plate, detachable. 20. Front cover plate, detachable. 21. Display/control panel. 22. Soot hatch. 23. Bypass damper. 2. Wood filling/soot hatch. 25. Latch, wood filling hatch. 26. Ash hatch. 27. Latch, ash hatch. 28. Opening for LPG ignition. Weight empty 730 kg full of water 930 kg Water volume 200 litre Fuel: Wood length 500 mm Wood store volume 200 litre 29. Back-pressure damper, primary. depth 550 mm 30. Motor/damper, primary air. 31. Motor/damper, secondary air. Filling hatch w x h 00 x 20 mm 32. Back-pressure damper, secondary. Power nominal 65 kw 33. Flue gas temperature sensor. Chimney requirements height 5 m 3. O2 probe. draught -0.15 mbar 35. Mains connection, 230 V~. 36. Supply, 230 V~, flue gas fan. diameter 180 mm 37. Supply, 230 V~, charging pump. Accumulator volume min. 3500 litre 38. Fan. Emissions - comply with EN-standard 303-5:2012. P21 28 29 30 31 32 33 3 35 36 37 38 26 27

ACCMLATOR TANKS CHOOSE AN ACCMLATOR TANK CAREFLLY There are many different types of accumulator tank available on the market and when choosing an accumulator you should choose for maximum efficiency, ease of installation and flexability. We believe our Aqualux range offers the best and most flexible choice. The tanks are packed full of ingenious solutions to make heating as simple and efficient as possible. IT S THE TANK THAT CONTS FTRE-PROOF YOR HEATING SYSTEM! An accumulator tank contains water and its main task is to store energy from one or more heat sources. To work as economically as possible, the tank must be able to handle the heat sources connected so that the water moves in the right way in the tank, so-called stratification. The Aqualux Teknik is optimised to produce optimum stratification with several heat sources connected. Stratification plates and diffusers in the Aqualux range maintain flawless stratification within the tank meaning heat from different sources enerts at the perfect level optimising effieciency of every heat source. The space saving design means these tanks fit neatly into most spaces and reduce work during the installation. ADVANTAGES OF AQALX TEKNIK: COMBINE ENERGY SORCES EFFICIENTLY FLEXIBILITY FOR GOOD ECONOMy LOW ELECTRICITY DEMAND MAKES WOOD FIRING EASY AQALX TEKNIK TANK WITH HOT WATER COIL TANK WITH HOT WATER COIL Aqualux Teknik, solar panel, heat pump Tank without diffusers and stratification plates Aqualux Teknik has 15-20% higher buffer capacity than a good coil tank and produces hot water even when the tank is almost discharged. If you have a solar panel, the tank can cope with several cloudy days. If you fire with wood, this means you have to fire less frequently. The tank is also not sensitive to lime in the water. A standard tank fitted with a coil is less efficient meaning that the hot water temperature can fall quickly. As a result the tank requires heat to be supplied more frequently. In addition, depending on location, the coil is sensitive to water containing lime. P22

Aqualux Teknik A B C D E F G Q W X Y Q E G VARMZON B A H I J K L Q I J MELLANZON V M N O Q K M KALLZON P Z O Immersion heaters are accessories. A Hot water Ø 22 mm C I Flow restrictor Ø 22 mm B Cold water Ø 22 mm C J Lower immersion heater, accessory G C Safety valve G 20 int. 50 int. D Air vent G 15 int. K Flow restrictor Ø 22 mm E Flow restrictor G 32 int. L Connection G 20 int. F Connection G 20 int. M HW from solar panel, coil Ø 22 mm C G pper immersion heater, accessory G N Connection G 32 int. 50 int. O CW to solar panel, coil Ø 22 mm C H Connection G 20 int. P Drain/expansion G 15 int. Some connections may have different functions. See outline diagrams. Q Immersion pocket for temperature sensor 8 mm int. Cable openings V Service strip W Thermometer, hot zone X Thermometer, intermediate zone Y Thermometer, cold zone Z Solar coil The illustrations show Aqualux 750 Teknik Accessories For other accessories, see the Price List Immersion heaters; see Price List for different models and outputs Accumulator controller RSK 687 60 16 Valve pack RSK 622 19 60 Shunt package for Teknik tanks RSK 622 19 59 Aqualux 500 B RSK 687 60 20 Aqualux 750 B RSK 687 60 1 P23

Aqualux 1000 Teknik/B 760 1855 +20, -0 W X Y E F G H I J K L 1187 Aqualux 1000 Teknik 100 A B C D =Teknik =B See page 20 M V N O P 760 Aqualux 1000 B D Teknik B Teknik B Teknik / B Volume: casing water 80 1000 litre Test pressure: tank water 2.2 2.2 bar Minimum 1,990 mm heater 160 - litre heater 13 - bar lifting height: Weight: empty 325 250 kg Design tank water 110 110 C Manufactured full 1,285 1,20 kg temperature: heater 110 - to: PED 97/23/EC article 3.3 Design tank water 1.5 1.5 bar Solar coil: area 3 - m 2 1000 Teknik: RSK 687 60 0 pressure: heater 10 - length 12 - m 1000 B: RSK 687 60 05 1187 Aqualux 750 Teknik/B 760 W X Y E F G Aqualux 750 Teknik A B C =Teknik =B See page 20 1650 +20, -0 H I J K L M N P O V 1067 100 760 Aqualux 750 B D Teknik B Teknik B Teknik / B Volume: casing 590 750 litre Test pressure: tank water 2.2 2.2 bar Minimum 1,820 mm water heater 160 - litre heater 13 - bar lifting height: Weight: empty 260 190 kg Design tank water 110 110 C Manufactured full 1,010 90 kg temperature: heater 110 - to: PED 97/23/EC article 3.3 Design tank water 1.5 1.5 bar Solar coil: area 3 - m 2 750 Teknik: RSK: 687 60 6 pressure: heater 10 - length 12 - m 750 B: RSK: 687 60 1 1067 D P2

Aqualux 500 Teknik/B 760 1650 +20, -0 W X Y E F G H I J K L 760 Aqualux 500 Teknik 100 760 C B A D Volume: Weight: Design pressure: =Teknik =B See page 20 Teknik B Teknik B Teknik / B casing 30 500 litretest tank water 2.2 2.2 bar Minimum 1,820 mm water 160 - litrepressure: heater 13 - bar lifting height: heater empty 220 15 kg Design tank water 110 110 full 720 65 kg temperature: heater 110 - tank 1.5 1.5 bar Solar coil: area length 2.5 - m 2 500 Teknik: RSK 687 60 65 water 10-10 - m 500 B: RSK 687 60 20 heater Aqualux 750 C M O N P V 760 C Manufactured to: PED 97/23/EC article 3.3 Aqualux 500 B D W X Y E A B D 1 1652 +20, -0 G 1067 2 J N P 760 V Volume: casing water heater 120 litre heater 13 bar Aqualux 750 C: RSK 687 60 0 630 litre Test pressure: tank water 2.2 bar Manufactured to: PED 97/23/EC article 3.3 Weight: empty 225 kg Design temperature: tank water 110 C full 975 kg heater 110 C Design pressure: tank water heater 1.5 bar 10 bar Minimum lifting height: 1,820 mm P25

Acktank 500 B RSK 687 60 67 Height 1,616+23 mm Width 75 mm Depth 770 Lifting height 1,780 mm Weight approx. 135 kg Water volume 500 litres Casing of galvanised sheet metal. 9 1 80 1325 1616 23 Design pressure 1.5 bar 1. Docking socket G 25 int. 2. Drain valve G 15 int. 3. Adjustable foot bolts. Thermometers 5. Connection G 25 int. 9. Immersion pocket 8x50 mm 1 92 172+20 2 3 75 3 770 5 75 373 373 Acktank 500 C RSK 687 60 66 Height 1,616 + 51 mm Width 75 mm Depth 770 mm Lifting height 1,780 mm Weight approx. 170 kg 51 9 1 80 23 Water volume 500 litres, of which 120 litres water heater, copper-lined. Casing of galvanised sheet metal. Design pressure 1.5 bar Suitable immersion heaters: All of Värmebaronen's immersion heaters 1. Docking socket G 25 int. 2. Drain valve G 15 int. 3. Adjustable foot bolts. Thermometers 5. Connection G 25 int. 6. Incoming cold water 22mm Cu 7. Hot service water 22mm Cu 8. Socket for immersion heater 9. Immersion pocket 8x50 mm 1616 3 02+20 190 100 8 8 1 2 75 7 6 5 26 92+20 172+20 1325 322 371 75 3 770 23 28 P26

Your heating specialist will be happy to advise you: AC GOL D Web: www.varmebaronen.org Email: sales@varmebaronen.org Värmebaronen products are distributed in the K by: AC Gold Distribution, 11 Back O Hill, Stirling, FK8 1SH Tel: 01786 89 099 Subject to technical alterations To give you the benefit of ongoing development efforts, we reserve the right to make technical changes without prior notice. Printing and layout errors or changes that have been implemented in the meantime do not provide grounds for any claims. Individual configurations depicted or described P28here are only optionally available. In the event of discrepancies between individual documents regarding the scope of delivery, the information provided in our current price list shall prevail. All images are symbolic images and may contain options which are obtainable for an additional charge.