Scientific Journal Impact Factor: (ISRA), Impact Factor: Methodology. [Yadav, 3(9): September, 2014] ISSN:

Similar documents
Performance Assessment of Water Cooled Condenser Refrigeration System

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Numerical Simulation of Window Air Conditioner

Experimental Investigations of Heat Pump for Domestic and Light Commercial Market.

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I


s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE

Performance Improvement of Window Air Conditioner by using Bottle Neck Arrangement

Economical and Energy Efficient Air Conditioner Using Calcium Liquid as a Secondary Refrigerant.

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Enhancement of COP in Vapour Compression Refrigeration System

Performance Optimization of the Evaporative Condenser Design

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Reheating Refrigeration System

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

R07. Answer any FIVE Questions All Questions carry equal marks *****

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

II. OBJECTIVE OF RESEARCH

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

Modified Air Cooler with Split Cooling Unit

Evaluation of Available Heat at the Exhaust of Automotive Engine for Air Conditioning by Vapor Absorption System

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

International Journal of Advanced Engineering Research and Science (IJAERS) Vol-3, Issue-2, Feb- 2016] ISSN:

Teaching and Examination Scheme PAPER HRS TH PR OR TW TOTAL TH TU PR

INSTITUTE OF AERONAUTICAL ENGINEERING

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Performance investigation of Air-conditioning system using ejector as expansion device

International Journal of Informative & Futuristic Research ISSN (Online):

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

HEATING AND COOLING EFFECT USING VAPOUR COMPRESSION CYCLE

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

A review on Efficient Technique of Air-Conditioning Rajesh Kumar, Pravesh Mishra, Ram Raja

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

ICMIEE-PI Design and Construction of a portable air cooler

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Design, Manufacturing of Chilled Water System for Process Cooling Application

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Performance of solid desiccant-based evaporative cooling system under the climatic zones of India

Design and Development of Combined Direct and Indirect Evaporative Cooling System

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

THERMAL OPERATING MACHINE GIUSEPPE VERDE. Student at Parthenope University of Naples, Italy

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Thermodynamics I. Refrigeration and Heat Pump Cycles

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

MODERN EVAPORATIVE COOLER

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

CHAPTER 1 INTRODUCTION

Refrigeration and Air Conditioning

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

[Mali*, 4.(12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

UNIT-1 Q.1 Draw P-V and T-s diagram of Reversed Carnot cycle (2M-Apr./May-2009) Q.2 Define Ton of refrigeration and COP. (2M- Nov/Dec-2009)

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Chapter 9. Refrigeration and Liquefaction

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

Superheat charging curves for technicians

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

EXPERIMENTAL INVESTIGATION ON RECOVERY OF WASTE HEAT FROM WINDOW AIR CONDITIONER

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

(Refer Slide Time: 00:00:40 min)

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Fabrication of A Prototype for Condensation of Water on Metal Surface Using Peltier Modules

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

Chapter 11. Refrigeration Cycles. Study Guide in PowerPoint

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Analysis of Vapour Compression Refrigeration System with Refrigerants R134a, R143a, R152a, R290 and R32

EXPERIMENTAL INVESTIGATION OF DIRECT EVAPORATIVE COOLER WITH HEMP AND ABACA COOLING PAD MATERIAL

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

ISSN Vol.08,Issue.21, November-2016, Pages:

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Transcription:

IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Effect of Evaporative Cooling on Air Conditioning Test Rig Mohit Yadav*, Prof. S.S Pawar *M.Tech (Thermal engineering) Bhabha Engineering & Research Institute, Bhopal, India Professor, Bhabha Engineering & Research Institute, Bhopal, India mohit.cseian@gmail.com Abstracts In this manuscript, we tries to prove that the size of air conditioner and power consumption by air conditioner can reduce by provide the effect of evaporative cooling on condenser. So, In our experiment we obtained the Coefficient of performance of air conditioning test rig and condition of air supplied by air conditioning test rig without evaporative then obtained the Co-efficient of performance of air conditioning test rig and condition of air supplied by air conditioning test rig. After find out the result in both cases, we compared both results and calculated the effect of evaporative cooling on air conditioning test rig with the help different parameters such temperature and pressure at different location, refrigerant flow rate, outlet air condition by D.B.T and W.B.T, wattmeter reading etc. We mentioned these results on P-h diagram and Psychrometric chart for better understanding. During our experiment we sprayed water on condenser at the rate of 500 ml/17 Minutes. Keywords: Co-efficient of performance (C.O.P), Evaporative cooling, Co-efficient of performance, Refrigerant flow rate, Power consumption Introduction increased by 39.04% which is great achievement. Air conditioner is used to provide cooling by Same if uses evaporative cooling effect on air the use of mainly four components Compressor, conditioning unit that will reduce the size and Condenser, expansion device and evaporator. These operating cost of air conditioning unit. four components are operate with a refrigerant which works as heat carrier in this system. It extracts the heat from evaporator in the form of latent heat and rejects that heat to atmosphere through the condenser [4]. Therefore heat rejection capacity depends on difference between refrigerant temperature at condenser and atmospheric temperature [5]. Quantity of heat rejection also affects the quantity of heat absorption through evaporator. It is clear that more heat rejection will result more heat absorption. Atmospheric temperature varies according to Environmental condition i.e. during the summer atmospheric temperature becomes higher which decreases the temperature difference between refrigerant and atmosphere, results less heat rejection which decreases the overall performance of refrigeration system[6]. In this paper, by experiment on Air conditioner test rig we proved that lower the condenser temperature means higher the performance of refrigeration system. Performance of refrigeration system can be improved by provide the evaporative cooling effect on condenser by spray of water on condenser which add the evaporative cooling effect on condenser. In last publication of December 2013 we have proved that by evaporative cooling on condenser the C.O.P is Methodology Fig.1. Refrigeration Test Rig [542]

If T 1, T 2 temperature of surrounding and temperature of evaporator than co-efficient of performance of system with Carnot cycle is given by- T 2 (C.O.P) Ref. = ------------ (A) T 1 T 2 Equation (A) defines that C.O.P of refrigeration system depends on T 1 and T 2. It means C.O.P of refrigeration system will be higher if T 1 is lower or T 2 is higher. Since lower temperature of evaporator is desirable so we should not increase the temperature of evaporator i.e. T 2. On other hand, we cannot reduce the temperature of surrounding i.e. T 1. So evaporative cooling of condenser is best option of reduce the temperature of water up to wet bulb temperature of air. For analyses the effect of evaporative cooling we have used following steps Steps - 1) First of all measure the D.B.T and W.B.T of ambient air with the help of Sling Psychrometer. 2) Start the air conditioner test rig for 30 minutes. 3) After 30 minutes, read the temperatures after compressor, after condenser, after expansion, after evaporator, D.B.T of supplied air, W.B.T of supplied air, suction pressure and exhaust pressure. 3) Also read the time taken by wattmeter to utilize 0.1 KWh energy by test rig. 4) Now repeat above mentioned procedure for spray water of temperature 24 o C. Results Here Following abbreviations are used: P 1 = Discharge Pressure P 2 = Suction pressure T 1 = Temperature after compressor, o C T 2 = Temperature after condenser, o C T 3 = Temperature after expansion device, o C T 4 = Temperature after evaporator, o C DBT = Dry bulb temperature temperature, o C WBT =Wet bulb temperature o C A) Refrigeration effect with spray water temperature of 23 O C After Evaporative Properties Before cooling of condenser P 1 133 psi 133 psi P 2 2.2 psi 2.2 psi T 1 62 o C 52 o C T 2 37 o C 33 o C T 3 1 o C -3 o C T 4 32 o C 30 o C B) Inlet and Outlet condition of air Before evaporative cooling of condenser Inlet conditions - DBT =31 o C, WBT = 22 o C Outlet Conditions- DBT = 27 o C, WBT = 21 o C After evaporative cooling of condenser Inlet conditions - DBT =31 o C, WBT = 22 o C Outlet Conditions- DBT = 25 o C, WBT = 18 o C C) Flow rate of refrigerant and energy consumption Before Evaporative cooling Flow rate of refrigerant measured by flow-meter = 8 LPH Energy consumption measured by wattmeter = 0.1KWh/16 Minutes After Evaporative cooling Flow rate of refrigerant measured by flow-meter = 6 LPH Energy consumption measured by wattmeter = 0.1KWh/21 Minutes D) Moisture condensed rate Before Evaporative cooling, Moisture condensed rate = Nil After Evaporative cooling Moisture condensed rate = 70ml/minutes E) P-h diagrams P-h diagram Before Evaporative cooling of condenser [543]

Fig.2 P-h diagram for air conditioner test rig without evaporative cooling P-h diagrams with evaporative cooling [544]

Fig.3 P-h diagram for air conditioner test rig with evaporative cooling F) Psychrometric chart [545]

Fig:4 Psychrometric chart for air with evaporative cooling and without evaporative cooling References 1. A text book of Refrigeration and air conditioning by R.S Khurmi and J.K Gupta, Edition 2006, Page 43 2. Engineering Thermodynamics, Fourth Edition by P.K Nag, Page 583 3. Air conditioning and refrigeration by Rex Miller and Mark R. Miller, Page 56 4. Refrigeration and air conditioning by G.F Hundy, Page 16 5. Engineering Thermodynamics, Fourth Edition by P.K Nag, Page 583 6. A text book of Refrigeration and air conditioning by R.S Khurmi and J.K Gupta, Edition 2006, Page 44 7. Ngenharia Térmica (Thermal Engineering), Vol. 5 No 02 December 2006 p. 09-15 8. Effect of evaporative cooling on refrigeration system by Mohit Yadav, IJESRT Dec; 2013. [546]