Innovative Technology for Traditional and Challenging Applications

Similar documents
Improving Quality and Productivity with Non-Contact Temperature

PRO SERIES NONCONTACT TEMPERATURE SENSORS

ARE ALL SINGLE-WAVELENGTH INFRARED THERMOMETERS ALIKE?

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Infrared Temperature Sensor

optris TM Temperature Monitor for Infrared Sensors Operators manual

Raytek /Ircon Solutions Guide

RS Pro Infrared Temperature Sensor

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Address: 2857 Sherwood Heights Dr. Unit 2, Oakville, ON, Canada. L6J 7J9 Toll free: LOGIKA

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

SS-100. Pyrometer. Temperature Range: 800~2400

Williamson Pro Series Pyrometer

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

INSTALLATION AND OPERATION MANUAL FOR THE PILOTEYE 2000

Raytek /Ircon Solutions Guide. The Worldwide Leader in Noncontact Temperature Measurement

Maxline 2 Thermal Imaging Solutions for Manufacturing

INSTALLATION AND OPERATION MANUAL FOR THE PYROSIGHT SERIES

IRT2 Dual Laser IR Thermometer - User Guide

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Dual Laser InfraRed (IR) Thermometer

Dräger Flame 2500 Flame Detection

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

More Precision. thermometer // Non-contact IR temperature sensors

Using the DewTrak II Dew Point/ Humidity Transmitter

A New Standard of Excellence

Dual Laser InfraRed (IR) Thermometer

Open-area Smoke Imaging Detection (OSID)

INSTALLATION AND OPERATION MANUAL FOR. The Flame Intensity Monitor

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Infrared Sensors for Industrial Automation. Raytek The Worldwide Leader in Noncontact Temperature Measurement

PUV, PIR and PFO Series BROCHURE

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Model D12-IR. Digital Gas Transmitter...

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

UDC100 Universal Digital Controller Specifications

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dräger Polytron Pulsar 2 Open Path Gas Detector

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

2 General Application Photoelectric Sensors

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Dräger Flame 2100 Flame Detection

R2310. Infrared Thermometer. Instruction Manual

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

ADPRO PRO Series by Xtralis

INSTALLATION AND OPERATION MANUAL FOR. The Flare Monitor

An FT-NIR Primer. NR800-A-006

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Sitron s CF Line of Flow Switch Monitors

Dräger Polytron 7000 Fixed gas detector

Advantages / Characteristics

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Temperature Sensors & Compression Seal Fittings

I/A Series 716C 1/16 DIN Temperature Controller

Principles of Noncontacting Infrared Temperature Measurement. Making Sense of Smart Infrared Temperature Sensors

THERMAL PROCESSING THEORY

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Open-area Smoke Imaging Detection (OSID)

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Using the Model 1500 Portable Chilled Mirror Hygrometer

Infrared Sensors for Industrial Automation. Raytek The Worldwide Leader in Noncontact Temperature Measurement

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Features and Benefits

Broadening IR applications through using spectral filters

More Precision. Innovative Sensor Technologies. Displacement Distance Position. Dimension Temperature Colour

SENSORS AND SYSTEMS FOR THE STEEL INDUSTRY

More Precision. thermometer // Non-contact infrared temperature sensors

Precision Infrared Thermometer. Users Manual

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

INFRARED HEATERS APPLICATIONS INFRARED HEATING

Lamp Supply (Recommended)

EC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

GAS PLUS ALARM SYSTEM

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

AS950 REFRIGERATED SAMPLERS

High Temperature InfraRed Thermometer with Laser Pointer

Danfoss gas detection unit Type GD Heavy Duty

Recalibrate the way you look at gas detection

Dräger Flame 2500 (IR3) Flame Detection

Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

Laser Level Measurement Products. Introducing the New LLT100

Distributed By: M&M Control Service, Inc Building Technologies

Dräger X-am 7000 Multi-Gas Detection

-REOTEMP s TC/RTD Background - Field Solutions - Product Overview -The REOTEMP difference

Transcription:

Silver, Gold and Pro Series

Innovative Technology for Traditional and Challenging Applications Infrared thermometers Temperature is commonly measured in manufacturing operations to monitor and control product quality and process productivity. For many applications, contact devices like thermocouples and RTDs are used, but for applications where these devices are inaccurate, too slow, or difficult to use, infrared thermometers are the perfect solution because they measure a target s temperature without contact. This capability is ideal for applications involving: High Temperatures Moving Targets Hostile or Hazardous Environments Fast Response Times With the Silver, Gold, and Pro Series sensors, Williamson offers the optimal sensor for a wide range of applications. Each sensor can be used as a stand alone transmitter with a choice of inputs, outputs, and alarms. For more advanced capabilities, an interface module, PID Controller, or PC software program are available. To help simplify the installation of the sensor and to provide added protection for severe environments, Williamson also offers a wide selection of accessories including mounting brackets, flanges, water cooling, air purges, and hazardous area enclosures. A COMPLETE RANGE OF TEMPERATURE SENSORS With the Silver, Gold, and Pro Series sensors, Williamson offers a complete range of single-wavelength infrared thermometers featuring state-of-the-art technology to provide accurate and reliable measurements for virtually any application. The miniature, low cost Silver Series sensors can be easily integrated into a 4-2mA loop or used to replace thermocouples for most general purpose applications in light industrial environments. These sensors are ideal for measurement of most non-reflective materials where precise alignment is not required. The Gold and Pro Series sensors include a complete selection of wavelengths, optics, and configurations to enable measurements of both traditional and challenging applications in heavy-industrial environments. With advanced capabilities, Gold and Pro Series sensors provide highly accurate measurements involving: general purpose applications unique materials such as thin film plastics, glass, or painted/coated surfaces intervening media, such as steam, water vapor, flames, or combustion gases that have the potential to interfere with a sensor s measurement accuracy SILVER SERIES features Temperature limits of -4 to 1832 F / -4 to 1 C with 1% measurement accuracy Miniature sensors for easy installation. Emissivity settings are fixed or adjustable with a 4-2mA input or a USB connection 4-2mA and voltage outputs which are linear with temperature Thermocouple or USB temperature outputs Internal sensor and process ambient temperature output 8-14um wavelength A choice of D/2, D/15, and D/3 resolution optics 2-wire or 4-wire configurations Stainless steel NEMA 4X (IP65) enclosures SAMPLE Applications Ferrous and Nonferrous Metals Induction Heat Treating Boilers, Incinerators, Kilns, Flares, and Thermal Reactors Ceramics including Bricks, Cement, Glass, and Refractory Semiconductor and Engineered Materials Aggregate, Ores, Soil and Asphalt Pharmaceutical Food Paper and Paperboard Plastics and Rubber Painted Surfaces Liquids and Pastes Silver U Class sensors feature an innovative design with adjustable settings using a USB port and SilverView PC software which is included with each sensor. Silver C Class sensors feature fixed sensor settings including an emissivity of.95 or a configuration with a 4-2mA input for remote emissivity adjustment (optional emissivity adjuster module is available). Silver M Class sensors feature a two piece design and miniature sensing head with up to D/3 optical resolution. Fixed sensor settings include an emissivity of.95. 2

THE GOLD AND PRO SERIES The Gold and Pro Series sensors share a common architecture featuring state-of-the-art infrared technology. Standard sensor features include: Temperature limits -4 to 45 F / -4 to 25 C Line of sight, visual aiming, laser aiming, and fiber optic aim light alignment options A complete range of precisely selected short, long, and specialty wavelengths A choice of low and high resolution optics 4-2mA and voltage sensor outputs which may be programmed with a choice of up to 5 different measured parameters Bi-directional RS232 and RS485 communications Built-in human interface with an intuitive text-based menu for sensor adjustments Stand alone sensors feature a menu selectable alarm relay or an analog input for remote emissivity and alarm set point adjustments Optional remote interface module with a built in AC power supply and a wide selection of output and alarm options. Rugged NEMA 4X (IP65) and NEMA 7X (Ex II 2G) enclosures EASY TO INSTALL, OPERATE, AND MAINTAIN Gold and Pro Series sensors are configured using an intuitive text based menu accessed from the sensor, an optional interface module, or via a computer with ProView software. When in the stand alone mode, the local user interface is used to display the temperature and adjust sensor settings including a programmable output and alarm. They also include an optional analog input for remote emissivity and alarm adjustments. Gold 2 Class sensors feature standard resolution optics and optional integrated laser aiming for precise verification of alignment. Pro 4 Class sensors feature high resolution optics, through the lens aiming, and optional integrated laser aiming for precise verification of alignment. The optional interface module is ideal for installations requiring remote temperature display and/or multiple programmable outputs and alarms. Gold 3 Class sensors feature a fiber optic configuration with a rugged, compact design and an optional built-in aim light. Pro 5 Class sensors feature a fiber optic configuration with a heavy duty design and an optional built-in aim light while offering high resolution optics. ProView PC software is compatible with the Gold and PRO Series sensors. It may be used to log and analyze data and to make remote sensor adjustments. 3

Greater Accuracy, Reliability, and Repeatability MEASURING INFRARED ENERGY Infrared thermometers collect the infrared energy emitted by an object and convert it into a temperature value. The amount of energy collected by a sensor is a function of the emissivity characteristics of the target and the transmission characteristics of any intervening media between the sensor and the target. Emissivity is a term used to quantify a material s tendency to emit infrared energy. It is measured on a scale of to 1., and it is related to the reflective and transmission characteristics of the material. For example, a highly reflective surface like aluminum has a low emissivity of.1, while a dull surface like refractory brick has a higher emissivity of.9. Intervening media such as steam, water vapor, flames, or combustion gases have the potential to interfere with the amount of energy that is measured by the sensor. SELECTING THE OPTIMAL SENSOR FOR AN APPLICATION To ensure accurate and reliable temperature measurements, it is important to select the sensor features which optimize the collection of infrared energy. This includes A wavelength where the emissivity of the target is high and constant and any intervening media between the sensor and the target is highly transparent. Sensor wavelengths vary by model and temperature range. A field-of-view (FOV) where the target is larger than the area viewed by the sensor (i.e. a full FOV). Sensor optics vary from low resolution optics for large targets to high resolution optics for precise alignment on small targets or to view through sight tubes and narrow gaps within the sight path. A sensor configuration which enables verification of alignment to the target. Options include lineof-sight alignment, through-the-lens aiming, integrated laser aiming, and fiber optic alignment with an optional built in aim light. Intervening Media D Infrared Energy WHY WAVELENGTH MATTERS The emissivity characteristics of a target and the transmission characteristics of any intervening media can vary by infrared wavelength. Williamson s singlewavelength sensors optimize performance by offering the most appropriate wavelength for each application. Field of View Full Partial d Short-wavelengths of 1μm, 1.6μm, and 2.2μm are preferred for most applications because they are less sensitive to variations in surface emissivity, optical obstruction, and misalignment. Long-wavelengths between 8-14μm are preferred for measurements near or below ambient temperatures, measurements of non-reflective, high emissivity materials, or for applications where accuracy is less critical. Specialty-wavelengths are required to measure selective emitters like plastics, coatings, and glass or to measure through different types of intervening media. Field of View (FOV) The field-of-view determines a sensor s viewing area for measuring the energy emitted from a target. All Williamson single-wavelength sensors may be used at any distance as long as the measured target is larger than the area viewed by the sensor (i.e a full FOV). A sample calculation of the FOV is as follows, if a sensor is mounted with a focal distance (D) of 5 inches from the target and it has an optical resolution factor (F) of 1, then the viewed target diameter (d) is.5 inches (d=d/f). LOW TEMPERATURE MEASUREMENTS of METAL TARGETS For applications like cold rolled steel, low temperature induction heating, or calendering rolls, shortwavelength sensors are required to compensate for the low and varying emissivity of the target. As the figure below illustrates, if there is a 1% change in the energy measured by the sensor, the measurement error of a long-wavelength sensor can be 5 times greater than a short wavelength sensor. Williamson s innovative Auto Null Technology, only available in Pro 42 and 52 sensors, is ideal for these applications as they feature short 2.2μm and 2.8μm wavelengths and measurement capabilities down to 75 F / 25 C. Temperature Error ( F) 6 5 4 3 2 1 ERROR FROM A 1% CHANGE IN EMISSIVITY OR OPTICAL OBSTRUCTION Measured Temperature ( C) -17 33 83 133 183 233 283 333 383 433 483 58 7 1.6µm Sensor 2.2µm Sensor 8-14µm Sensor 4 36 32 28 24 2 16 12 8 4 Temperature Error ( C) 1 2 3 4 5 6 7 8 9 1 Measured Temperature ( F) 4

Measurements through Steam, Flames and Combustion Gases The need to view a target inside a flame-fired heating chamber or to view a target through steam, flames, or combustion gasses is common. As the figure below illustrates, despite being highly transparent in the visible spectrum, carbon dioxide, and other gases that are naturally found in air are significantly opaque over a wide range of the infrared spectrum. For these measurements, Williamson s 1.6μm and 2.2μm sensors use unique narrow band filters that avoid interference from steam, flames, and combustion gases. Competitive sensors which use much wider infrared filters (1.-1.75μm and 2.-2.8μm respectively) cannot view clearly through these common gasses. Transmittance % 1 Measurement of Selective Emitters Materials such as thin film plastics and glass require precise sensor wavelength selection because these special materials, known as selective emitters, are highly opaque and non-reflective only at specific wavelengths. the figures below illustrate the different transmission characteristics of some materials where Williamson offers unique measurement capabilities. polyethylene film Williamson s 3.43μm narrow band wavelength enables measurements on polyethylene films as thin as.25 mil. Transmission through air and combustion gases H 2 O H 2O H 2O H 2 O H 2 O INTERFERENCE WILLIAMSON SENSOR Transmittance % CO 2.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 3. 1 75 5 25 CO 2 Wavelength µm 3 4 5 6 7 8 9 1 11 12 13 14 Wavelength µm H 2O CO 2 1 mil 1 mils FIBER OPTIC SENSORS The Gold 3 and Pro 5 Class utilize innovative fiber optic features for greater durability and flexibility when sensor installations involve confined spaces or severe environments. These sensors use a small, Teflon-sealed fiber optic cable to view the target while the sensor is mounted in a remote or more convenient location. While the sensor ambient limit is typically 14 F / 6 C, the fiber cables can withstand ambient temperatures as high as 4 F / 2 C. Teflon Sealed Fiber Optic Cable Lens Barrel Measured Target Field of View The fiber optic sensors feature cable lengths ranging 3 to 3 feet (1 to 9 meters) as well as a variety of unique mounting and protective accessories for hostile operating conditions. A few highlights include: polyester film Williamson s 7.9μm narrow band wavelength enables measurements on polyester films as thin as 1 mil. Glass Williamson offers a narrow band 7.9μm wavelength to measure the real surface temperature of the glass as well as a 5μm wavelength which can measure just below the surface of the glass. Transmittance % Transmission & Reflectance % 1 75 5 25 1 8 1 mils 3 4 5 6 7 8 9 1 11 12 13 14.9 Thick Wavelength µm 6.61 4 Reflectance 2.231 2.5 3 4 5 6 7 8 9 1 11 12 Wavelength µm WILLIAMSON SENSOR WAVELENGTHS 1 mil Rugged glass (G) and quartz (Q) fiber optic cables Heavy Duty ArmorGurard (AG) with built in Air Purge Flexible, light weight Stainless Steel Braid (SSB) with built in Air Purge 5

Improving Quality and Productivity with Non-Contact Temperature ADVANCED CAPABILITIES THAT ARE EASY TO USE With integrated processing electronics and an easy to use text based menu system, the Gold and Pro Series sensors can be configured for a variety of process monitoring and control capabilities. The Gold and Pro menu system can be accessed from the sensor, an optional interface module, or via ProView PC software. Programmable output and alarm parameters include: Filtered Temperature, Unfiltered Temperature, Ambient Temperature, Rate of Change, Cell Strength (Auto Null). Gold and Pro Menu system Signal Conditioning Average Time Peak/Valley Hold Temperature Scale ( F/ C) Emissivity Rate of Change Multiplier Configure Inputs and Outputs Select Measured Parameter Select Scale (4-2mA, -2mA) Configure the Output Range Configure Remote Input for Emissivity or Alarm Set Point Configure Alarms Select Measured Parameter Select Set Point Value Diagnostics System Test Analog Output Test Alarm Test Menu Lockout Status Messages Out of Temperature Range High Ambient Warning Aiming System Status Status of Digital Communications Interface Module specifications For installations requiring remote temperature display and advanced programming capabilities, the interface module offers the following: 2 programmable analog outputs 1 programmable analog input 2 programmable relay alarms Bi-directional digital communications (RS485/RS232) Built-in power supply with 9-26Vac input Sensors Designed for any requirements To help select the optimal sensor for an application, this table highlights the unique features of each series. Sensor Alignment Line of Sight Integrated Laser Aiming Through the Lens Visual Aiming Fiber Optic with optional integrated Aim Light Spectral Response Short Wavelengths (1, 1.6, and 2.2µm) Long Wavelength (8-14µm) Application Specific Wavelengths Field of View (FOV) Low Resolution Optics (D/2 to D/3) Standard Resolution Optics (D/15 to D/1) High Resolution Optics (D/1 to D/15) Human Interface and Signal Processing Integrated Sensor Menu System and Display Adjustable Sensor Settings via PC Application ma & Voltage Outputs J, K and T Thermocouple Outputs Sensor Based Relay Alarm or Analog Input Sensor specifications Silver Series Gold Series Pro Series C M U 2 3 4 5 This table is an overview of sensor specifications. All Williamson sensors include a 2 year warranty and CE Certification. See individual data sheets for complete details. Measured Temperature Limits Nominal Accuracy Repeatability Response Time Emissivity Input Power Analog Inputs / Outputs Digital Communications Ambient Temperature Limits Enclosure -4 to 1832 F / -4 to 1 C 1% of reading.5% of reading or +/-.5 C whichever greater Better than 1 C 24ms (9% of Response) C Series: Fixed at.95 or Adjustable.2 to 1. M Series: Fixed at.95 U Series: Adjustable.1 to 1. 6 to 28Vdc (2mA) 4-2mA, Linear Voltage or Thermocouple Outputs C Series: Optional 4-2mA Input to Adjust Emissivity U Series USB Silver Series 32-158 F / -7 C w/ Water Cooling Limit is 482 F / 25 C Stainless Steel Enclosures with NEMA 4X (IP65) Rating Gold and Pro Series -4 to 45 F / -4 to 25 C.25% to.5% of reading 24Vdc (3mA) 5 to 1ms (95% of Response) update time is 5 to 5ms Adjustable.1 to 1.5 4-2mA, -2mA, or voltage outputs, alarm, and analog input to adjust emissivity or alarm set point RS485 or RS232 to 14 F / -17 to 6 C to 12 F / -17 to 5 C (Auto Null models only) w/ Water Cooling limit is 35 F / 175 C Fiber Optic Assembly limit is 4 F / 2 C Stainless Steel and Aluminum Cast Enclosures with NEMA 4X (IP65) Ratings, optional NEMA 7X (Ex II 2G) are available 6

Measurement SENSOR WAVELENGTH SELECTION GUIDE Williamson s single-wavelength sensors optimize performance by offering the most appropriate wavelength for each application. The table below summarizes the options available. Typical Application Temperature Limits Sensor Model Nominal Wavelength SYSTEMS for industrial applications Williamson offers a complete range of infrared thermometers for a wide range of traditional and challenging applications. Sample industries include: Short - Wavelength Sensors - Best for Tolerating Emissivity Variation, Misalignment & Optical Obstruction Metals, Refractory, and Other High Temperature Applications Silicon Processing View through Water 1-45 F 54-2475 C 21, 31 41, 51 1µm Metals and General Purpose Applications Flame-Fired Processes Bulk Glass Temperatures View through Steam, Water Vapor, Flames, and Combustion Gasses 5-32 F 26-175 C 21, 31 41, 51 1.6µm Steel General Purpose Applications Low-Temperature, Low-Emissivity Metals Flame-Fired Processes View through Steam, Water Vapor, Flames, Combustion Gasses, Plasma, Thin Plastics and Oil 15-25 F 65-1375 C 22, 32 42, 52 2.2µm Specialty - Wavelength Sensors - Selected to Measure or View Through Specific Materials General Purpose Applications Chromate and Zinc-Coated Strip, Safety Glass Lamination Low-Emissivity Materials 75-8 F 25-8 C 42 2.8µm Industrial heating Thin Films of H-C-Based Plastics (e.g. Polyethylene and Polypropylene) 125-7 F 5-175 C 43 3.43µm Boiler Tubes Refractory Walls Glass Subsurface Views through Flames and Combustion Gasses Hot Combustion Gas CO or CO2 Producing Flames Glass Surfaces - Especially Inside Furnaces, Ovens and IR Heaters 4-4 F 2-22 C 6-4 F 3-22 C 2-4 F 1-22 C 24, 44 25, 45 25, 45 3.8µm 4.65µm 5µm petrochemical glass General Purpose Applications using Quartz Infrared Heaters Glass Surfaces Thin Plastics such as Polyester, Acrylic, and Teflon Epoxy and Painted Surfaces 85-25 F 3-1375 C 28, 48 7.9µm Semiconductor, Superconducting, Crystalline Materials, Zirconium and Alumina all Require Specific Wavelengths for Measurement Hot Slug Detector for Fiberglass Batting Hot Spot Detector for Rubber Conveyor Belt Protection Hot Metal Detector for Forging Plant, Rolling Mill and Caster operations Per customer requirements Per customer requirements Various Various Various Various Cement Long - Wavelength Sensors - Best for Measurement of Near-Ambient Targets and Non-Reflective Targets General Purpose Applications below 5 F / 25 C with Non-Reflective, High Emissivity Materials -4-2 F -4-11 C C9, M9, U9 29, 49 8-14µm 7

Unequaled Performance in Temperature Measurement ACCURATE MEASUREMENT Of COMPLEX MATERIALS Infrared thermometers measure the amount of infrared energy emitted by an object s surface, and then convert this signal into a temperature value. While many factors affect the measurement accuracy, the most important consideration is the selection of the sensor that most effectively compensates for the emissivity characteristics of the measured surface. Emissivity is a term used to quantify a material s tendency to emit infrared energy. It is measured on a scale of to 1., and it is related to the reflective and transmission characteristics of the material. For example, a highly reflective surface like aluminum has a low emissivity of.1, while a dull surface like refractory brick has a higher emissivity of.9. Versatile systems to meet any requirement Williamson s advanced infrared thermometers feature state-of-the-art technology to provide accurate and reliable measurements for challenging applications in heavy-industrial environments. Surface Emissivity Characteristics Spectral Emissivity 1..8.6.4.2 Blackbody/Near Blackbody = High and constant emissivity Greybody = Lower and changing emissivity NonGreybody = Low and changing emissivity that varies by wavelength 1 2 3 4 5 6 7 8 9 1 Wavelength (µm) Typical Applications Single Wavelength Food Processing Paper, Rubber, Textile, Plastics, and Paint Ceramic, Glass, and Aggregate Flame Fired Processes Low Temperature Metals Dual Wavelength Casting, Forming, and Heat Treating of Metals Welding and Brazing Crystal Growing and CVD Multi Wavelength Alumininum, Copper, Brass and Other Nonferrous Metals Annealed, Galvannealed, and Stainless Steels Sensor Single Wavelength T > -4 F / -4 C Silver C,M,U (line of site) Gold 2 (Laser) Gold 3 (Fiberoptic) PRO 4 (Visual) PRO 5 (Fiberoptic) Dual Wavelength T > 3 F / 15 C PRO 8 (Visual) PRO 9 (Fiberoptic) Multi Wavelength T > 3 F / 15 C PRO 1 (Visual) PRO 2 (Fiberoptic) Williamson Sensor Selection Guide Application Characteristics Single-wavelength sensors provide an average temperature measurement of the measured target area, and short wavelengths are recommended to reduce or eliminate errors due to emissivity variation. The Patented Auto Null Design eliminates noise and calibration drift often associated with this type of sensor. Advanced signal processing techniques allow for broad temperature ranges, operation at low temperatures, and long term calibration stability. These sensor s are recommended for applications involving: A constant emissivity with an unobstructed view of the target (all temperatures) Low temperature measurements of low-emissivity materials Dual-wavelength sensors tend to measure the hottest temperature viewed in the target area, and they provide automatic compensation for emissivity variations of greybody materials. With a unique single-detector design and the industry s highest signal dilution factor, Williamson s dual-wavelength sensors outperform all other ratio sensors when demanding application issues exist. Typically difficult application issues include: Low or varying emissivity Intervening media such as dirty optics, scale, steam, dust, or water spray A partially filled field-of-view caused by a mechanical obstruction or a small or wandering target Multi-wavelength sensors utilize programmable ESP algorithms to provide aim and read capabilities for non-greybody materials that are not accurately measured by single and dual wavelength sensors. These sensor s are recommended for applications involving: Non-Greybody Materials such as aluminum, brass, chrome, copper, molybdenum, stainless steel, tin, titanium, tungsten, and zinc Intervening media such as dirty optics, scale, steam, dust, or water spray A partially filled field-of-view caused by a mechanical obstruction or a small or wandering target SW Rev. WILLIAMSON CORPORATION 7 Domino Drive, Concord, Massachusetts 1742 TEL: (978) 369-967 FAX: (978) 369-5485 (8) 3-8367 (USA) sales@williamsonir.com www.williamsonir.com