Caice Attenuator Selector - Specifier Edition

Similar documents
Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Efficient Cooling and Heating. Flexibility Is The Key

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Air Handling Units. direct drive - belt drive - custom built

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Specification Data. General:

Panther Fan Coil Unit

air handling units AT THE LEADING EDGE OF AIR FLOW

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Air Handling Units. direct drive - belt drive - custom built

TOSHIBA AIR CONDITIONING

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

TopVent Design Handbook

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

CLIMACIAT AIR COMPACT

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

INDUSTRIAL AIR CURTAIN. IndAC 2

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Air Handling Units. Real HVACR people who understand your needs.

for fresher air Air Handling AIR VENT TECHNOLOGY Units DIRECT DRIVE - BELT DRIVE - CUSTOM BUILT Certificate No: GB9455

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

VERSO Air Handling Units

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

SIMPLICITY OR FULL MODULARITY?

SIMPLICITY FULL MODULARITY?

Air Handling Units. direct drive - belt drive - custom built

Installation, Operation and Maintenance Instructions Document Ref:

COOLSTREAM S T A R PRODUCT OVERVIEW COOLSTREAM S T A R

VERSO Air Handling Units

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

EC Motor Fan Coil Units. IMD-Y Series l/s

Denco has been producing and installing. equipment specifically designed for the precise. control of air temperature, humidity and quality

DF-IDF air handling units

SMOKE CONTROL - NEW DIRECTIONS

Gemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control

FAN COIL UNITS. The optimal solution for limited space

Panther Fan Coil Units

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

Installation, Operation and Maintenance Instructions Document Ref:

for fresher air Air Handling AIR VENT TECHNOLOGY Units DIRECT DRIVE - BELT DRIVE - CUSTOM BUILT Certificate No: GB9455

System architecture. Air treatment Index

... DF / IDF Gas fired combined heating and ventilation ...

CASSETTE UNIT. Comfort Circle

Systemair product news - Fans NEWS

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Operating Performance

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Closed Circuit Cooling Towers

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

LTV - LTV-N Air Handling Unit

Instruction Manual. Cheetah Fan Coil Unit. Installation Operation Maintenance

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Modular Supply Make-Up Air Unit

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Installation, Operation & Maintenance Instructions Document Ref:

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

INDUSTRIAL AIR CURTAIN. IndAC 2

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Centeral Station Air Handling Unit

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Mission Critical Air Conditioning Systems

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

VENTILATED CEILINGS PLENUM SPANTILE COMBINED ADVANTAGES

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Flexible & Innovative. Cooling Solutions

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

COMPACT AIR HANDLING UNIT

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

Installation and Maintenance

WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

UniTrane Ductable Units D-line and B-Line

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

HYBRID PLUS2 AIRCOOL VENTILATORS

EDPAC International Close Control Air Conditioning Products E

Optimal work climate with open doors. Industrial air curtains Model IndAC

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Energy-efficient heat source provides comfort in large rooms

Transcription:

Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Attenuation Auto Changeover Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Attenuation Auto Changeover Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Attenuation Auto Caice Attenuator Selector - Specifier Edition System Administrator s Guide Product Brochure

1 Caice Evolution Acoustic Fan Units Caice s Evolution fan unit range offers a competitively priced, high quality, air movement solution for supply, extract, transfer, or run & standby applications. Available in various sizes and offering an air volume range of up to 1.5m 3 /s, all units offer a versatile range of control options making them suitable for installation in a variety of building environments. Our heritage as a manufacturer of market leading attenuation products for more than 20 years is at the heart of the design, development & testing of our fan units. Each unit in the range combines robust and energy efficient fan technology with excellent acoustic properties ensuring that air movement performance will not compromise noise level requirements. 360 product tour available on-line www.caice.co.uk Our attention to detail means that our clients can be sure that the high levels of quality and reliability they have come to expect from Caice products are all naturally exhibited in this latest addition to the range.

2 Features & Benefits Guaranteed Acoustic Performance Our in-house acoustic design service will guarantee that our fan units will achieve your specified noise criteria. EC Fan Motors Electronically Commutated motors set the standard for energy efficiency and ensure that all of our units are compliant with Part L of the Building Regulations. Modular Design Optional integral attenuation modules with quick bolt and cleat assembly provide great flexibility and ease of installation. Flexible Control Options Our fan control packages offer maximum flexibility for BMS compatibility or standalone operation. Automatic Changeover and Duty Share Run & standby models include an automatic changeover controller offering redundancy in the event of fan failure. The duty share feature allows alternate operation of fans for extended unit longevity. Variable Air Volume Supported All units in the range support Variable Air Volume (VAV) operation for further efficiency gains when combined with a suitable control system. Slim Line Cabinet Design The slim line cabinet design allows easy installation into ceiling or floor voids making Caice Fan units ideal for internal installation within residential, hotel, office & school environments. Easy to Maintain Simplified access panels allow for fan assemblies to be replaced on-site with minimal disruption.

3 Acoustic Fan Unit We have brought together over 20 years experience in noise control and built this into the design and development of our fan units, enabling us to offer the best acoustic performance of any fan unit on the market. All units are manufactured with a double skinned galvanised sheet steel cabinet style casing. This method of construction makes for a more robust unit and offers a greater level of insulation and sound proofing from the noise of the unit in operation. Using a patented design, fan motors within the case are mounted on a floated deck which is isolated from the rest of the casing. This feature minimises transmission of vibration and acoustic energy through the unit s casing. Our thorough approach to noise control on the inside of the unit means that Caice supply a complete solution which is ready to install. This removes the need for ancillary vibration isolators or flexible connections which increase costs and the complexity of installation. Double skinned galvanised sheet steel cabinet style casing No need for ancillary vibration isolators or flexible connections Fan motors are mounted on a floated deck

4 Performance The Caice Evolution Acoustic Fan Unit range consists of nine duty fan configurations, and four run & standby units. Duty fan models handle air volumes of up to 1.5m³/s whilst run & standby models handle up to 0.75m³/s. Full details on the performance characteristics of the units in the range are available in our separate technical data brochure. Component Options The Evolution fan unit range also offers a number of supplementary component options. Heating, cooling and frost protection requirements can be catered for by adding CHW, LPHW or DX heat exchanger coils, or electric heating elements. To assist in maintaining air quality, we offer EU4 panel filters and EU6 bag filters, which will suit most applications. An EU2 wire framed filter option is also available for units operating in internal air recirculation applications. Shut-off dampers can be provided to assist in preventing unwanted draughts when the unit is not in operation. Supplementary Attenuation Helps Evolution Acoustic Fan Units achieve noise levels as low as NR25. Matching Attenuation The innovative product design extends to our range of supplementary attenuation. Rectangular attenuators with casing construction matching that of the fan box enables our units to meet stringent noise criteria as low as NR25. Rectangular attenuators have been optimised to balance the attenuation performance offered against the additional pressure loss imposed. Certain fan models are available with optional circular connections. Our circular attenuators with a straight through design provide attenuation without imposing additional resistance to airflow.

5 Efficient, Reliable & Compliant Caice Fan Units are designed and built for efficiency, reliability and full compliance with building regulations. All units comprise Electronically Commutated (EC) fans. These units are up to 70% more energy efficient at providing the same duty when compared to their AC equivalent. With negligible amounts of heat being generated whilst running, this leads to better performance and longer life expectancy of the unit. Intelligent automatic control of the motors in our twin fan units provides built-in redundancy for greater reliability, further extending the unit s service life. The efficiency characteristics of Caice s Fan Units naturally lead to full compliance with Document L of the Building Regulations & combine to provide a lower total cost of ownership. Ongoing maintenance of any unit is easy thanks to simplified double skinned access panels which allow straightforward inspection or replacement of fan motors. Above EC fan motors can help to deliver significant cost savings Below Efficient and quiet running make Caice s Evolution Fan Units ideal for inclusion in school ventilation systems

6 Efficient, Reliable & Compliant Caice s Evolution Fan Units Changeover and Duty Sharing Our run & standby units are provided with an automatic changeover control as standard. In the event of a fan motor failure the automatic changeover controller senses that the motor is no longer running and automatically switches over to the second fan. Fault signalling on the controller indicates that one of the fans has failed and that the unit requires maintenance. The controller can also be used in duty share mode. A user defined time period of up to 31 hours can be set. In this configuration, the unit will operate the run fan until it has accumulated the preset time period, after which it will automatically switch to the standby fan to continue to provide the desired duty. In addition, this package will also provide for local or remote fan speed control options and unit enabling. From full BMS to standalone applications, Caice fan unit controls can be configured to meet your needs. Variable Air Volume When used in conjunction with a Building Management System (BMS) our fan units fully support Variable Air Volume (VAV) operation leading to further efficiency gains. Operating in this mode & triggered by sensors connected to a BMS, the fan unit s motor speed can be adjusted using a 0 to 10V DC signal. Responding to environmental conditions means that under normal requirements the fan motors can often be run below full design duty. This is particularly beneficial when a space is unoccupied, allowing a substantial reduction in speed leading to significant energy savings along with reduced noise levels. Equally fan speed can be increased to provide additional ventilation for higher duty requirements when the space is occupied.

7 Acoustic Design Service Where a fan unit is being installed in or serving a noise sensitive area we understand the importance of making sure that the unit meets the acoustic design requirement. We also appreciate that this is a complicated issue with many contributing factors. Our unique Acoustic Design Service offers our clients unparalleled support in this critical area of product selection and design. We will undertake post-order acoustic calculations to ensure that all units are selected to meet the acoustic requirements of a project. We also carry out a pre-tender design review where we are specified on an equal or approved basis. This is why we can say with confidence that our acoustic design service will guarantee that our fan units will achieve your specified noise criteria, regardless of the complexity of the installation. Room Finishes Noise Criteria Layout Drawings Grilles, Diffusers & Plenums Ceiling Construction Room Dimensions Acoustic Design Service Working with your design parameters we can ensure that noise criteria requirements are met.

Acoustic Design Service Product Selection Support Tailor-made Attenuation Guarantee to Meet Noise Criteria 8

9 Design & Manufacture All of our fan products have been designed & brought to manufacture by our own in-house product development team. This is just the start of the journey, the same level of care and attention to detail goes into every unit as it is manufactured at our state of the art Production Centre in Dorset. Caice s automated manufacturing facilities are the most advanced in our industry. Taking advantage of integrated software & control systems along with lean production techniques helps us to produce high quality Fan Units at low cost here in the UK. We constantly strive for product improvement with our on-going investment in fan research and development. This leads to products designed to suit our clients needs. The cost savings we make in developing and manufacturing the unit ourselves are passed on directly to our clients ensuring that our product prices always remain competitive. Delivered On Time We work with our clients at every stage of a project, adapting to changing timescales to make sure that our products arrive on site exactly when they are needed. Our team of delivery and dispatch coordinators make sure that a delivery date is agreed & confirmed prior to dispatch. Each product is labelled and scanned onto pallets and then wrapped securely. It is then loaded and scanned onto the vehicle which is delivering it ensuring that all items are loaded as agreed. Finally we work with our team of hauliers to provide appropriate transport to ensure that the delivery can access the project site. This close liaison and attention to detail mean that our products are produced and delivered on time, leading to a 99.8% On Time In Full (OTIF) delivery performance.

Designed & Manufactured by Caice Purpose built facility in the UK 99.8% OTIF Delivery Performance 10

11 Summary Specification The summary specification explains the key attributes of each of the components and options which make up a Caice Evolution Fan Unit. Chassis All units are manufactured from galvanised sheet steel with built in flange connections to enable easy on site assembly into ductwork with 30mm DOBY, MEZ or METU flanging systems, or circular duct spigot connections on certain models. Run and standby units are fitted with shutters to avoid air recirculation via the standby fan. Underside access is standard on fan boxes, although top access can be provided on request. Fans and Motors Units may be fitted with either double inlet, double width forward curved centrifugal fans with steel impellors, or backward curved centrifugal fans with plastic impellors. All fans are operated by direct drive EC (electronically commutated) motors operating from a 230v/1ph/50Hz supply. All motors have an IP42 rating or better, and incorporate maintenance free bearings with a life expectancy of 40,000 hours in normal operation. Attenuators Attenuator sections are fitted with internal lining elements manufactured from galvanised expanded steel mesh. Larger units are fitted with splitter type elements incorporating a peripheral steel frame. All attenuator elements are packed with controlled density acoustic media (mineral wool), with fibreglass tissue bonded to the rear of the facing. Filters Where fitted, air filters of the required specification will be installed within a retaining frame to enable slide-out removal, and prevent the by-pass of air. Filters shall be one of the following types: EU2 (G2) wire framed washable foam filter EU4 (G4) disposable pleated panel filter with card frame EU6 (M6) disposable bag filter with rigid header frame. Heat Exchangers Where provided, coils are manufactured from copper tubes with aluminium fins, and retained within galvanised steel casings. Where cooling coils are fitted, a galvanised steel drip tray shall also be provided with slope to fall towards a 22mm plain pipe connection. Air velocities across the finned area of the coils shall not generally exceed 3.0m/s for heating coils, or 2.5m/s for cooling coils. Coils are tested to 24.5 barg Electric Heaters Where provided, electric heater elements will function in black body condition. A thyristor control package (incorporating airflow sensing and high temperature cut-out) may be fitted for single phase heaters up to 6kW. Other controls or interlock devices may be required to comply with I.E.E. or other local regulations. Controls All units are fitted with a metal speed control housing on the side of the fan box. This will house the core PCB and any other devices necessary for operation of the fan unit. The control is provided with cable entry to allow the connection of a 230v/1ph/50Hz power supply cord on site by others.

12 Casings Galvanized sheet steel casings Fans & Motors High efficiency EC motors Heat Exchanger Coils tested up to 24.5barG

Your Evolution Fan Team Here at Caice we pride ourselves on delivering the best possible service to our clients where ever they are in the UK. We also know how important it is to our clients to have the same point of contact which they can always turn to for all of their product needs. Our teams of experienced engineers are based conveniently at offices across the UK. They are on hand to offer advice, design expertise and after sales support not just for our fan products, but for the entire Caice product range. From your first contact with Caice you will have a dedicated account manager, sales coordinator and design engineer ready to help whenever you need them. We also know that it is reassuring to be able to contact your dedicated team when you need their assistance. This is why we provide you with their direct contact details so you can get straight to the expertise you need. To find out more about your dedicated team, please ask your account manager or contact us using any of the details at the bottom of the page. 13

14 Useful Fan Unit Resources The following documents offer further information about Caice Evolution Fan products along with more details about our broader range of complementary products. They are all available now at www.caice.co.uk/fans Evolution Fan Unit Data Sheets Scan this QR Code with a smartphone Detailed information about our entire range of units featuring schematic diagrams, physical data and quick selection matrices. Fan Commissioning Quick Reference Guide Published by our acoustic consultancy partners, Lee Cunningham Partnership, this guide explains the influencing factors and guidelines for commissioning a unit. Caice Attenuator Brochure & Selection Software A comprehensive guide to Caice s market leading attenuator product range and details of how to download the Caice Attenuator Selector software package.

Telephone 0118 918 6470 Facsimile 0118 918 6480 enquiries@caice.co.uk www.caice.co.uk Caice Acoustic Air Movement Ltd. Riverside House 3 Winnersh Fields Gazelle Close Winnersh Wokingham RG41 5QS Registered office and head office Company Registration Number 2790667 VAT Registration Number GB614683632