Enhancing K-12 Security

Similar documents
Your partner for security solutions

Your partner for security solutions

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Maintaining Building and Fire Safety During Active Assailant Events and Other Terrorist Events

Keys to an Effective School Lockdown

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

designing for School Safety and Security

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Effective Messaging on School Door Locking

School Security A Look at Classroom Door Locking Solutions Frank Rocky Rivas, AHC, FDAI, CSI, CDT, CAT, ASSOC. AIA.

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Safe and Secure. Introducing Responsive Lockdown

Don t Panic! An Introduction to Facility Exit Devices

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

January 1, 2014 Mandatory Effective Date

Facility/Campus Lockdown Plan Elements

Simple Security Improvements Can Go A Long Way

THE BIG FIVE Community Packet

BUILDING EMERGENCY ACTION PLAN

Safe and Secure. Introducing Responsive Lockdown

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

EMC Company Background. Top 10 List (cont.) Top 10 List. Locked Door Policy. 1. Lack of a Security Culture

Draft. Security Study. Germantown School District Germantown, WI. PRA Project # February 2014

E25 (D) Automatic controls for general means of egress lighting

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

Teachers. Updated / /20. Emergency Contacts 1. Evacuation 2. Lockdown 3. Exterior Lockdown 4. Clear the Halls 5. Reverse Evacuation 6

NFPA Talking Points on NFPA 1 Fire Code update to the 2015 Edition:

Education. Life Safety and Security Door Hardware. Integrated Door Security Systems. Safety, Security and Risk Management

October 1, Full *2 Sprinkler System

BUILDING EMERGENCY ACTION PLAN

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

EMERGENCY LOCK DOWN PROCEDURE

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

NJASA SCHOOL SECURITY CONFERENCE

Touchpad Exit Controller User Guide

Schools and the Fire Code A Partnership for Safety

Section 3. Preparedness. Shelton School District Emergency Response Plan

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

Physical Security for Elementary Schools

Section 9 THE GUIDELINES FOR DEVELOPING AN EVACUATION PLAN FOR INDIVIDUALS WITH DISABILITIES. Shelton School District Emergency Response Plan

Campus Emergency Response Plan Standard Operating Procedure

SAFETY DRILLS Lincoln County School District

NFPA 70E Elevates Safety. with Heightened Risk Awareness

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Fire safety procedure

Board of Education Meeting

University of Maryland FIRE EVACUATION PLAN

PASS Security Plan Checklist

Fire Evacuation Plan Davidge Hall. UMB POLICE or

Fire Evacuation Plan Bressler Research Building. UMB POLICE or

FIRE SAFETY INSPECTION REPORT

EMERGENCY RESPONSE PLAN

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

CAMPUS COMMUNITY FIRE AND LIFE SAFETY POLICY

Healthcare. Life Safety and Security Door Hardware. Integrated Door Security Systems. Safety, Security and Risk Management

INFORMATIONAL PUBLICATION SECURITY VS. EXITING... Door Locking Hardware in Schools

EMERGENCY RESPONSE GUIDELINES

Southern Baptist Theological Seminary. The Michael Minger Act Report for Activity Reported for Calendar Year 2004

EMERGENCY ACTION CHECKLIST

GEORGIAN COLLEGE OPERATING PROCEDURES & PRACTICES. Revised Responsible Procedure Date: Department: Administration Number: LOCKDOWN

Emergency Action Plan

Annex 2 - Shelter-in-Place

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

About IntraLogic. In Business since 2004 Over 55 Full time employees

TSUNAMI PREPAREDNESS CHECKLIST FOR K-12 SCHOOL ADMINISTRATORS AND PRINCIPALS

Emergency Procedures Overview

East Mississippi Community College Scooba Campus * Mayhew Campus * West Point Department of Public Safety Campus Emergency Action Plan

LIFE SAFETY CODE ESSENTIALS PRESENTED BY: LARRY VIGIL, RISK CONSULTANT

Emergency Planning for Institutional Facilities

New School Construction: Safe School Opening. OAR and IOR Joint Training February 17, 2005

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

Life Safety - Means of Egress/Exits NFPA 101

Building Emergency Policies and Procedures

Relocation vs. Evacuation Drills Practice Makes Perfect Public Education Conference

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Phase II: School Safety Report_ _15:42

School Emergency Practices and Procedures

Safety & Security. Plainview-Old Bethpage Central School District

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

FIRE SAFETY PLAN Revised December

Vacaville Schools. Upgrade Classroom Security

Emergency Guidebook WEAPONS ON CAMPUS ACTIVE SHOOTER BOMB THREAT FIRE / EXPLOSION CRIME REPORTING EVACUATION HAZMAT SPILL HIGHWAY HOSTAGE SITUATION

Barrier Management- Defending the Safety of Patients, Visitors, & Staff

Gaston County Schools/Gaston County Police March 13, WE ARE Gaston County Schools

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

Safety & Security Checklist by Layers of Building and Grounds The Church Safety and Security Guidebook (Brotherhood Mutual Insurance)

LOS ANGELES UNIFIED SCHOOL DISTRICT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY PROCEDURE

Phase II: School Safety Report_ _08:56

UNIVERSITY OF MANITOBA PROCEDURE

This regulation outlines procedures to be followed for fire drills and all school event decorations.

FLORIDA MEMORIAL UNIVERSITY ANNUAL CAMPUS SAFETY REPORT

ICC CODE CORNER 2015 International Fire Code

LINDENWOOD UNIVERSITY BASIC EMERGENCY ACTION PLANS

University Design Standard Fire Alarm Systems

Building Emergency Policies and Procedures

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

REFERENCES: ESSENTIALS OF FIRE FIGHTING, FOURTH EDITION, IFSTA ===============================================================

Florida Building Code 2010

Transcription:

The official publication of ALOA SPAI, an international association of security professionals October 2016 SECURING YOUR SUCCESS Enhancing K-12 Security Recent code proposals may shake up safety practices Show Stoppers The inside scoop on product highlights from the ALOA 2016 Security Expo PLUS Kaba Peaks: Unveiling the Mystery Meet the ALOA Instructor Run for the IAIL Board Apply for an ALOA Scholarship

Enhancing K-12 SECURITY Recent code proposals and a few best practices can help students stay safe during emergencies. By Lori Greene, DAHC/ CDC, CCPR, FDAI, FDHI 20 KEYNOTES OCTOBER 2016 D espite the dramatic advances in construction, technological tools and safety protocols that have been made in the past two decades, this progress is not always evident in many of our nation s K-12 buildings. Too often, the much-needed funding for upgrades including security improvements is deferred in favor of other capital requirements. But emergency situations can t be postponed until the next fiscal year or fundraiser. School officials and administrators should be encouraged to consult with security professionals and begin the process of evaluating their existing interior and perimeter security measures and protocols to develop a proactive strategy to keep students and faculty safe in the event of emergency. W W W. ALOA.ORG

There are many products on the market that can assist with classroom security and egress issues. Recent code change proposals might effect schools selections to enhance safety. Interior Security It s an unfortunate reality that the catalyst for school administrators to prioritize security measures is often a major tragedy such as an active shooter event. Reactionary security planning in the wake of these events has resulted in several states rushing to approve the installation and use of barricade devices in classrooms, ignoring both existing codes and the warnings of fire marshals and other code officials. Many of these devices are not code compliant and could actually prohibit egress and endanger the life safety of the school s occupants in the event of an emergency. Fortunately, a change has recently been approved for the International Building Code that will require all locking devices used on classroom doors to allow safe evacuation as well as access for school staff and emergency responders. 1010.1.4.4 Locking arrangements in educational occupancies. In Group E and Group B educational occupancies, egress doors from classrooms, offices and other occupied rooms shall be permitted to be provided with locking arrangements designed to keep intruders from entering the room where all of the following conditions are met: 1. The door shall be capable of being un- W W W. ALOA.ORG locked from outside the room with a key or other approved means. 2. The door shall be openable from within the room in accordance with Section 1010.1.9. 3. Modifications shall not be made to listed panic hardware, fire door hardware or door closers. 1010.1.4.4.1 Remote operation of locks. Remote operation of locks complying with Section 1010.1.4.4 shall be permitted. The key points in this code change are: This language applies to K-12 schools, colleges and universities. The locking requirements apply to classrooms and also to offices and other occupied rooms. If the rooms are lockable, they must be able to be unlocked from the outside. Locks are not required, but if locks are used, the doors have to meet the requirements for egress: one operation to unlatch, no key/tool/special knowledge/effort, no tight grasping/pinching/twisting, etc. Listed panic hardware, fire door hardware and door closers may not be modified. Remote operation is acceptable if the locks meet the other requirements of this section. Of course, in addition to the challenge of keeping intruders out, many schools also struggle to prevent the elopement of young children and students with special needs. Although NFPA 101: Life Safety Code currently allows the use of delayed egress locks in educational and day care occupancies, the International Building Code (IBC) does not, so the most restrictive hardware that would be compliant with the IBC is an exit alarm. To address this issue and give schools another option for deterring egress, the BHMA Codes & Government Affairs Committee and the International Code Council s (ICC) Building Code Action Committee both submitted code change proposals for the 2018 IBC. These proposals would allow delayed egress locks to be used in educational occupancies if the building is equipped throughout with an automatic sprinkler system or approved automatic smoke or heat detection system. Proposal E68-15 was approved by the ICC committee and will be incorporated into the 2018 edition of the IBC. In that edition, educational occupancies will be listed as one of the use groups where delayed egress locks can be used without the restriction on occupant load. While it will be some time before both of these codes are adopted, they will go OCTOBER 2016 KEYNOTES 21

a long way toward establishing a consistent approach to classroom security nationwide. Jurisdictions are encouraged to adopt this approved code language ahead of the local adoption of the complete code, rather than to create language that will be inconsistent with other locations. Perimeter Security In addition to improving internal security measures, school officials and administrators should be encouraged to implement the following best practices for enhancing their perimeter security. These measures will help to prevent unauthorized access and ultimately create a safer learning environment. 1. Establish a single point of entry for school hours. This is preferably a frontdoor location that is easily seen and supervised to provide more control over who should and shouldn t enter the building. The main entrance should be clearly marked by signage with directions to a visitor management center. 2. Create a vestibule to manage visitor entry. Many schools create a vestibule at the main entrance to provide an additional layer for perimeter security. The design automatically funnels visitors into a main office before granting them access to other parts of the building. It s important to consider accessibility and egress requirements for these doors as well as security. 3. Install electronic access control. Access control systems have become an increasingly popular way to enable the lockdown of a facility in the case of an emergency. When implemented properly, the access control software can centrally manage user authorization and monitor all doors. In addition to the challenge of keeping intruders out, many schools also struggle to prevent the elopement of young children and students with special needs. 4. Install institutional-grade products. Schools environments are subject to high levels of wear and tear, and it s important to make investments in products and solutions that are built to withstand abuse. Every opening should be built with institutional-grade doors, frames and door hardware, as properly functioning openings are key to successful security management. 5. Ensure that all other points of entry are secure at all times. Unsecured doors have the potential to allow two types of events to occur unnoticed: either an uninvited guest entering or a student exiting. Often, an entry point becomes compromised when a teacher or student props it open for the sake of convenience. Sensors are available that alert staff via an audible alarm when a door isn t secure, and door status switches notify access control or monitoring systems of any issues. 6. Develop a lockdown strategy. It s been proven that lockdowns save lives. Students who were locked down in their classrooms at Sandy Hook Elementary School survived. All schools should have the tools in place to lock down immediately if an emergency arises. There are three proven lockdown technologies: Manual lockdown uses mechanically locking hardware to lock down a space. This is an economical option but relies upon an individual having the right key in hand and being at the right opening during a lockdown situation. Remote lockdown enables classroom lockdown by remote fob within proximity of door and is a cost-effective alternative to a networked system. Centralized lockdown, a networked system, can enable immediate school or campus-wide lockdown when integrated with access control software. 7. Train and drill all staff on policies, procedures and technologies. For security solutions to perform at their best, school staff must be fully trained on policies, procedures and technologies. Faculty and staff, including substitute teachers, must be thoroughly familiar with the school s panic alarms and interoperable communication systems if these tools are to be used effectively. Training and drills must be consistent and repetitive; one time isn t enough to ensure proper execution during a real emergency. Another key point is to ensure that policies and procedures are not viewed as suggestions or optional to be successful, they must be mandatory. 22 KEYNOTES OCTOBER 2016 WWW.ALOA.ORG

One bright spot in the discussion of how to make schools safer is the fact that overall rates of school violence are falling. Conclusion One bright spot in the discussion of how to make schools safer is the fact that overall rates of school violence are falling. According to the latest study by the National Center for Education Statistics (NCES), between 1992 and 2014, the total victimization rate at public schools declined 82 percent. That s a significant decline, and although the report didn t cite any specific cause for the falling crime rates, it did note that the percentages of public schools reporting the use of various safety and security measures has been steadily increasing over the last 15 years. While the report doesn t directly link the two, it will seem obvious to anyone in the security or architectural hardware industry that improving access control and security results in a safer school environment. But, although the rates are falling, there s a still a great deal of work that needs to be done. School administrators, parents and teachers are all relying on this industry to provide the necessary training and solutions that are essential to providing a positive, safe learning environment for future generations of students. Lori Greene, DAHC/CDC, CCPR, FDAI, FDHI is the manager of codes and resources for Allegion. For more information about this topic and to download a free reference guide on codes, visit idighardware.com/guide.