REQUIREMENTS FOR TENTS, CANOPIES & MEMBRANE STRUCTURES

Similar documents
REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

Note: The event coordinator is responsible for compliance of all regulations.

Note: The event coordinator is responsible for compliance of all regulations.

Outdoor Festival and Special Event Guidelines

SafetyNet FIRE MARSHAL S OFFICE. Food Booth and Vendor Regulations

EXCELSIOR FIRE DISTRICT

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

4. Distances to property line, buildings, other tents, parked vehicles and engines;

Tents and Temporary Membrane Structures Packet

Tents and Temporary Membrane Structures Permit Procedure

REQUIREMENTS FOR EVENTS AND TEMPORARY STANDS AT FAIRS AND SHOWS

General Festival Conditions & Temporary Use of Tents Conditions of Approval

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

Canby Fire District 221 S. Pine Street Canby, OR97013 Bus Fax Fire Marshal, Todd Gary

FIRE DEPARTMENT PERMIT GUIDELINES

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Township of Upper Providence Office of the Fire Marshal

SANDUSKY FIRE DEPARTMENT Fire Prevention Bureau. Dear Prospective Food Vendor:

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

FIREDEPARTMENT REGULATIONS AND GUIDELINES

30 DAY TEMPORARY TENT APPLICATION ON EXISTING COMMERCIAL PROPERTY

FIRE DEPARTMENT CONDITIONS BELLEVUE FESTIVAL OF THE ARTS Fire Retardant or Flame Retardant Treatment

PERMIT APPLICATION Central Pierce Fire & Rescue 902 7th Street NW - Puyallup, WA Telephone (253) Fax: (253) 538.

CITY OF OKLAHOMA CITY SPECIAL EVENT REQUIREMENTS Revised January, 2011

South Elgin & Countryside Fire Protection District

Exhibits and Trade Shows Permit Application

Calgary Fire Department Indoor Special Event Requirements. August calgary.ca /fire call

Fire and Life Safety Review Form

City of Leduc Fire Services Indoor Special Event Requirements

ATTACHMENT B FIRE CODE REQUIREMENTS FOR EXHIBITS AND SPECIAL EVENTS

FIRE SAFETY GUIDELINES

MOBILE FOOD VENDING Food Trucks & Trailers

MOBILE FOOD VENDOR DEFINITION & FIRE INSPECTION INFORMATION

PLACES OF ASSEMBLY CHAPTER 17

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

Anticipated Date and Time for Completion of Break-Down:

Dear Exhibitor, To assist in th. and safety issues that you may encounter with your booth.

Fire Safety Guidelines and Requirements CenturyLink Field and Event Center June 2015

Stillwater Area Community Services Center Inc.

To expedite the plan review and inspection processes, please refer to the information below.

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

FOOD PREPARATION WITHIN EXHIBITS

PALM SPRINGS FIRE DEPARTMENT REGULATIONS FOR TRADE SHOW EXHIBITORS, CONVENTIONS AND SPECIAL EVENT GATHERINGS BASED ON THE 2010 CALIFORNIA FIRE CODE

FIRE PREVENTION CODE

SAFETY GUIDELINES INDIANA STATE FAIRGROUNDS & EVENT CENTER. Fairgrounds Security:

UC Irvine Environmental Health & Safety TITLE: Special Events Program

Department of Public Safety

All orders are governed by the GES Payment Policy and GES Terms & Conditions of Contract as specified in this Exhibitor Services Manual.

Fire and Life Safety Requirements San Mateo City Special Events

Consumer Fireworks Retail Sales (CFRS) Facility Requirements.

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

STANDARD DETAILS & SPECIFICATIONS Spec No _SI _ Rev. Date 10/20/11

School Fire Safety Checklist

SEMINOLE FIRE DEPARTMENT TENT PERMIT CONDITIONS

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

CITY OF TOLEDO. Paula Hicks-Hudson. MAYOR Our Division s web-site can be accessed 24/7 at

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

SALT LAKE OFF-ROAD EXPO 2018 Sponsor Information Friday-Saturday April 27 th & 28 th 2018 South Towne Expo Center Hall 5 Off-Roaders Unite!

CITY OF TOLEDO. MICHAEL P. BELL MAYOR Our Division s web-site can be accessed 24/7 at

Element 14.7 Fire Prevention and Control 2018

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

HEALTH DEPARTMENT Environmental Health, Mosquito Control, Neighborhood Protection, Stormwater, and Animal Services

Camden County Fire Rescue Office of the Fire Marshal 125 N. Gross Road, Kingsland, GA

Fire Prevention Plan. California State University, Chico

MULTI-LEVEL & COVERED BOOTH CONDITIONS

OUTLINE FOR FIRE PREVENTION ACTIVITY

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

Temporary Use Permit Application Check List

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

Level I Chapter 1 Worksheet

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

FIRE & SAFETY REGULATIONS (Updated )

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Facility Manager Training

Safety Tips for the Office

Temporary Haunted Houses

VENDOR AGREEMENT PACKET

Fire/Life Safety Policy

Brighton Fire Rescue District

McCormick Place Fire Safety Regulations

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

For additional information please contact the Chesapeake Fire Prevention Office at or at

Assisted Living Facilities

Community Festival Permit Application - Cypriot Community of Toronto Inc. - Cultural and Wine Festival June 23 and 24, 2007

Safety Manual Section 7 Fire/Life Safety

Saturday, September 9 th 2017 ***** NO PETS ALLOWED

C I T Y OF P U Y A L L U P City Clerk s Office

DEPARTMENT OF FIRE AND EMERGENCY SERVICES

Business License Pre-inspection Checklist

FACILITY REGULATIONS

Transcription:

Pierce County Department of Emergency Management LOWELL PORTER Director Fire Prevention Bureau WARNER WEBB 2401 South 35 th Street Room 2 Fire Marshal Tacoma, Washington 98409-7494 (253) 798-7179 FAX (253) 798-2731 www.piercecountywa.org/fpb REQUIREMENTS FOR TENTS, CANOPIES & MEMBRANE STRUCTURES 1) Fire Code permit is required for the following: Tents and membrane structures in excess of 200 square feet. Canopies in excess of 400 square feet. Note: You may have an aggregate of up to 700 square feet of canopies when separated from other canopies by at least 12 feet. 2) Comply with current International Fire Code, Chapter 31. 3) Certificate of Flammability to be included with permit application, except when attached to or printed on tent, canopy, etc. 4) Aisle ways and exits shall be maintained free of obstructions at all times. 5) Fire extinguisher(s) with a minimum rating of 2A:10BC shall be installed within 75 feet of travel distance. 6) No parking within 20 feet of tent. 7) Cooking & heating shall be in accordance with IFC 3104.15. 8) Signs indicating NO SMOKING shall be posted. 9) Open or exposed flame shall be in accordance with IFC 3104.7. 10) See plan for any additional requirements. 11) INSPECTION REQUIRED PRIOR TO OPENING TO THE PUBLIC. Call (253) 798-7179 (at least 24 hours in advance) to schedule inspection. 12) VALID SIGNED PERMIT WILL BE DELIVERED UPON APPROVAL AT TIME OF FIRE PREVENTION BUREAU INSPECTION. After hours inspection fee: The Fire Prevention Bureau shall charge an additional fee of $80.00 per hour, with a one-hour minimum, with additional time to be computed in quarter hour increments, and to include travel time. (Reference Pierce County Code 17C.60.085.F) N:\FPB\FORMS\FIRE CODE PERMITS\TENT REQUIREMENTS.doc Rev. May 2012 EMERGENCY MANAGEMENT EMERGENCY MEDICAL SERVICES FIRE PREVENTION E9-1-1 RADIO COMMUNICATIONS

TEMPORARY WIRING NOTE: The Fire Inspector shall have the authority to require the vendor to disconnect and/or remove any non compliant electrical device. The graphic below is presented to give a visual understanding of approved and non-approved methods of temporary wiring for light and appliances at fairs, carnivals and shows. Remember the following parameters: 1) Extension cords that are less than 14 gauge in size will not be allowed to extend electrical service. 2) Extension cords shall supply power to one multi-plug adapter only. 3) Multi-plug adapters shall not be used in a series. 4) Approved multi-plug adapters/power taps with a testing laboratory s label stamped on them, or attached to them are allowed. The word APPROVED means the unit has been tested and approved for it s intended use by a nationally recognized testing laboratory; such as Underwriters Laboratories or Factory Mutual. Adapters must have over current protection that will activate and shut off the current if the adapter is overloaded. Note: If you are unable to reach the outlet with the plug connected to the appliance, you will require an extension cord of 14 gauge or larger (Larger would be 10 or 12 gauge.) N:\FPB\FORMS\HANDOUTS FOR COUNTER\EXTNCORDS2011.doc reference: 2009 IFC section 605

Canopies Used For Cooking continued PERMIT Canopies used for cooking shall require a permit regardless of size. The following minimum information shall be submitted with the application: 1. A SITE PLAN showing the canopies in relationship to property lines; other structures; access roads; fire hydrants; parking areas; and dimensions of the canopies a. Fire apparatus access roads to the canopy shall be indicated on the site plan. b. Canopies shall not be located within 20 feet of property lines, buildings, parked vehicles, internal combustion engines, amusement rides, or non-cooking canopies. c. The aggregate area of multiple canopies placed side-by-side without a fire break clearance of 20-feet shall not exceed 700 square feet total. 2. The START DATE and Time shall be indicated, as well as the end date and time. INSPECTIONS A Fire Prevention Bureau inspection is required prior to use of the canopy to ensure all code requirements are met. In the case of an event with multiple vendors, ALL vendors shall be set-up prior to inspection. Call 253-798-7179 at least 24 hours in advance to schedule an Inspection. After Hours Inspection: Should an after hours inspection be required, the Fire Prevention Bureau shall charge an additional fee of $80.00 per hour with a one-hour minimum with additional time to be computed in quarter-hour increments, and to include travel time. CANOPY FABRIC The vendor shall provide the Pierce County Fire Marshal Inspector evidence that the canopy is composed of material meeting the flame propagation performance of NFPA 701 or shall be treated with a flame retardant in an approved manner and meet the fire-resistive standards of NFPA 701 (Certificate of Flammability). EXTINGUISHERS Portable fire extinguishers shall be provided in every canopy used for cooking as follows: 1. All cooking which produces grease-laden vapors shall have a minimum 2.5-gallon (9 L) or two 1.5-gallon (6 L) Class K wet-chemical portable fire extinguishers. 2. A minimum of one 2A:10BC dry chemical extinguisher shall be provided in each canopy used for cooking. 3. Deep fat frying requires a tight-fitting metal lid readily available to be used to cover the fryer in the event of a grease fire. LPG CONTAINERS LP-Gas containers shall be limited in size to 10-gallons. Containers shall be limited to those necessary for continuous operation, and any additional containers including empties shall be stored away from the canopy. Page 2 of 3

Canopies Used For Cooking continued Containers that are in use shall be located outside the edge of the canopy; safety release valves shall be pointed away from any canopy. Portable LP-Gas containers, piping, valves, and fittings shall be adequately protected to prevent tampering or damage, and be securely fastened in place to prevent unauthorized movement. TEMPORARY WIRING Extension cords that are less than 14-gauge in size shall not be allowed to extend electrical service. Extension cords shall supply power to only one multi-plug adapter. Multi-plug adapters shall not be used in series. Approved multi-plug adapters and/or power taps shall be UL listed or FM approved and have over-current protection that will shut off the adapter if the adapter is overloaded. GENERATORS Generators and other internal combustion power sources shall be separated from a canopy used for cooking by a minimum of 20 feet and shall be isolated from contact with the public by fencing, enclosure, or other approved means. COMBUSTIBLES Hay, straw, shavings or similar combustible materials shall not be located within any canopy used for cooking. The canopy shall be kept clear of combustible waste. Combustible trash shall be placed in a metal can with a lid. NO SMOKING Smoking shall not be permitted in a canopy. Approved No Smoking signs shall be conspicuously posted. N:\FPB\POLICY\3000-3999 PLAN REVIEW\3400-3449 TENTS, CANOPIES & MEMBRANE STRUCTURES\POL 3401 Canopies used for cooking.doc Page 3 of 3