Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Similar documents
FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FH4A Fan Unit. Sizes 001 thru 004

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. FK4C Direct Expansion Fan Coil. Sizes 001 thru 006

Product Data CF5A COILS KMABA BLOWERS. For Manufactured Homes THE CF5A INDOOR COIL

FAN UNIT FH4A Sizes 001 thru 004

Product Data. FV4A Direct Expansion Fan Coil ICM2 and Puron Refrigerant. Sizes 002 thru 006

Product Data. FV4A Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Model Number Tons Nom. CFM (L/s) Dimensions H x W x D in. (mm) Filter Size in. (mm) Ship Wt lbs.(kg)

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

15 to 20 degree higher supply air temperatures 100 degree minimum supply air temperatures Up to 30 times more humidity removal

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

Product Data. FK4D Direct Expansion Variable Speed Fan Coil. Sizes 001 thru 006

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

PAJ3. Product Specifications

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

MODEL FK4C DIRECT EXPANSION FAN COIL. Sizes 001 thru 006. Form No. PDS FK4C.01.3

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

FCM4X. Product Specifications

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

Product Data. HUM Humidifiers

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Product Data. PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

WJH4 Product Specifications

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

PAR5. Product Specifications

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Models 566D 569C,576B with 524A 6to30Tons

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

R4H4. Product Specifications

Product Data PH4Z SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -410A REFRIGERANT SINGLE PHASE 2 TO 4 NOMINAL TONS (SIZES )

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Model 655A Sizes

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data MECH. Mechanical Filter Air Cleaner

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

MODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A--

ELECTRIC HEAT Field installed accessory heaters are available in a wide range of capacities with single point wiring connections. High Temp.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

N4A6. Product Specifications

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

R4H4. Product Specifications

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

WPH4 Product Specifications

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. Fig. 1 - Unit 50VG -A

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 604D SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R -410A) REFRIGERANT SINGLE AND 3 -PHASE UNITS 2 to 5 NOM TONS (SIZES )

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

FXM4X. Product Specifications FAN COILS FXM4X

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

Product Data. Fig. 1 - Unit 50EZ -A

Product Data PA13NA PA13PA FEATURES AND BENEFITS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Transcription:

Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are available with factory- or fieldinstalled electric heaters both of which include the disconnect. A fieldinstalled cooling control with disconnect is also available. A TDR (Time Delay Relay) is included with either the electric heat or the cooling contorl packages. The FF1DNE models are available with a factory installed TXV. This fan coil may be installed free standing, wall hung, or flush mounted in the wall. The 22-in. wide cabinet size in all models allows units to fit between standard stud spacings. No return air ductwork is required if the application provides for return air in the front of the cabinet through either a louvered closet door or an optional accessory decorative grille panel. The cabinet exterior is made of prepainted galvanized sheet metal. The cabinet is fully insulated to meet applications in conditioned space. Additional insulation is required if the unit is installed in an unconditioned space. Unit is supplied with replaceable filter. Multispeed direct-drive PSC blower motors have been selected to provide the proper air handling for both heating and cooling. Motors are suspended at 3 points on rubber grommets for quieter operation. All refrigerant lines, electrical power, and thermostat wiring enter from the top of the cabinet. Sweattype refrigerant connections on both liquid and suction lines make for swift, low-cost installation. All service access to the unit is conveniently located in the front. The AccuRater piston ensures efficient and dependable refrigerant metering, and eliminates potential service requirements of other metering devices. The AccuRater is located inside the unit, easily accessible for piston maintenance or changeout. Copyright 2003 Carrier Corporation Form FF1D-2PD

In addition, units can be factory ordered with a hard shut-off thermostatic expansion valve (TXV) metering device for performance improvement. The drain pan is constructed of high-impact, sound-deadening, corrosion-proof polyester resin. Primary and secondary drain connections exit from the bottom or either side of the cabinet. Model number nomenclature F F 1 D N A 018 075 F Fan Coil 1 Upflow F Through-the-Wall D Major Series N 208/230-1-60 A Standard E TXV Electric Heater (kw) 000 005 075 011 Nominal Capacity (Btu) 018 18,000 024 24,000 030 30,000 UNITARY HEAT PUMP UNITARY AIR CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION LISTING TESTING INSPECTION CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. 2

Dimensions FF1DNA, FF1DNE REFRIGERANT LINES ENTRY NOTE: 1. SERIES DESIGNATION IS THE 14TH POSITION 2 OF UNIT MODEL NUMBER. 3 8 2 7 16 2 13 16 LOW VOLTAGE ENTRY ( 7 8 DIA. HOLE) POWER ENTRY 1 3 8 DIA. KNOCKOUT 7 8 DIA. HOLE 2 3 4 3 4 15 3 16 8 1 4 4 3 16 OUTLET AIR 7 8 1 5 8 TOP VIEW 22 1 8 5 3 16 11 3 16 10 1 16 1 9 16 COIL 1 1 8 DIA. KNOCKOUT 38 1 16 3 1 4 SUCTION TUBE 24 1 16 BLOWER, CONTROL AND ELECTRIC HEATER ACCESS PANEL LIQUID TUBE UNIT CONNECTION SIZES SUCTION, 018, 024, 030-3 4 I.D. SWEAT LIQUID, 3 8 I.D. SWEAT CONDENSATE, 3 4 NPT FILTER MEDIA 3 4 INLET AIR SECONDARY DRAIN 13 16 5 11 16 5 SIDE VIEW PRIMARY DRAIN 9 7 16 11 1 16 FRONT VIEW 11 1 16 5 PATCH PLATE FAN COIL BASE BOTTOM VIEW A98336 3

Physical data UNITS W/O ELECTRIC HEATERS OR CONTROLS UNITS WITH ELECTRIC HEATERS 018 024 030 UNIT SIZE 018 024 030 005 075 011 005 075 011 005 075 011 OPER WT (Lb) 68 70 73 75 76 77 79 80 82 REFRIGERANT R-22 Refrigerant Control FF1DNA Refrigerant Control FF1DNE AccuRater Bypass Type AccuRater No.* 55 63 70 55 63 70 COIL TXV Slab Type, Aluminum Fins Rows Fins/In. 2 14 3 14 2 14 3 14 Height x Width (In.) 18 x 17.8 22 x 17.8 18 x 17.8 22 x 17.8 Face Area (Sq Ft) 2.23 2.72 2.23 2.73 BLOWER & MOTOR Air Discharge Blower Type Upflow Direct Drive Wheel Diameter (In.) 10 Wheel Width (In.) 6 Motor HP (PSC) 1/12 1/5 1/3 1/12 1/5 1/3 Rpm (2 Speed) 810/750 980/780 1110/950 810/750 980/780 1110/950 Motor Speeds & Type 2 & PSC Filter Size Cleanable (In.) 16 x 20 x 1 AIRFLOW Nominal CFM 650 870 1080 650 870 1080 CONNECTIONS (Sweat) Suction 5/8 3/4 5/8 3/4 Liquid 3/8 3/8 Condensate (FPT) (In.) 3/4 3/4 CLEARANCES Front-Servicing (In.) 21 (Servicing Only) Cabinet & Supply-Air Duct (Plenum included) 0 * Check outdoor unit for required piston size. 018 Size with 11-kw heater not approved for use with heat pumps. Electrical data OPER VOLTS* Min Wire Size (AWG) BRANCH CIRCUIT Max Max Fuse or Ft Ckt Bkr Wire Amps Control Transformer 24v (VA) UNIT SIZE V/PH Max Min FAN FLA MCA WITHOUT ELECTRIC HEATERS OR CONTROL 018000 0.7 024000 208/230 1 253 187 1.5 14 15 030000 2.0 WITH FACTORY-INSTALLED ELECTRIC HEATERS OR CONTROLS 018005 10/10 23.5/25.9 112/112 25/30 018075 208/230 1 253 187 0.7 8/8 34.8/38.4 118/118 35/40 40 018011 6/6 50.6/55.9 125/125 60/60 024005 10/10 24.5/26.9 112/112 25/30 024075 208/230 1 253 187 1.5 8/8 35.8/39.4 117/117 40/40 40 024011 6/6 51.6/56.9 122/122 60/60 030005 10/10 25.2/27.5 112/112 30/30 030075 208/230 1 253 187 2.0 8/8 36.4/40.0 117/117 40/40 40 030011 6/6 52.3/57.5 125/125 60/60 * Permissible limits of the voltage range at which the unit will operate satisfactorily. Use copper wire only. 75 C wire must be used in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60 C conductors, instead of wire sizes shown in table above per NEC 1996 Article 336-30. FLA MCA Full Load Amps Minimum Circuit Amps 4

Performance data UNIT SIZE 018 024 030 COIL REFRIGERANT TEMPERATURE* ( F) EVAPORATOR 35 40 45 50 55 AIR CFM AND Evaporator Air Entering Wet-Bulb Temp ( F) BF 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 400 27 23 19 25 20 16 22 17 13 19 14 10 15 10 8 0.08 13 14 15 12 13 13 10 11 12 9 10 10 8 8 8 500 30 25 21 28 22 18 24 19 15 21 15 12 16 11 10 0.10 14 16 17 13 14 16 12 13 14 10 11 12 9 10 10 600 33 27 22 30 24 19 26 21 16 23 17 13 18 12 11 0.13 15 17 19 14 16 18 13 14 16 11 13 13 10 11 11 650 34 28 23 31 25 20 27 21 17 23 17 14 18 13 12 0.14 16 18 20 14 17 18 13 15 16 12 13 14 10 11 12 600 38 32 26 35 29 22 31 24 18 26 19 14 21 13 12 0.05 18 20 21 16 18 19 15 16 17 13 14 14 11 11 12 700 41 34 28 38 30 24 33 26 20 28 20 16 22 15 13 0.06 19 21 23 18 19 21 16 18 19 14 15 16 12 13 13 875 46 38 31 41 34 27 37 29 22 31 23 19 25 17 16 0.08 21 24 27 20 22 24 18 20 22 16 18 19 14 15 16 750 46 38 31 41 33 26 36 28 21 30 22 17 24 16 14 0.04 21 23 25 19 21 22 17 19 20 15 16 17 12 13 14 900 50 42 34 46 37 29 40 31 23 33 25 19 26 18 16 0.06 23 26 28 21 23 25 19 21 22 17 18 19 14 15 16 1075 54 45 37 49 40 32 43 34 26 37 27 22 29 19 18 0.07 25 28 31 23 26 28 21 23 25 18 21 22 16 17 18 * Saturated suction leaving evaporator coil. Sensible Heat Capacity (1000 Btuh) Gross Cooling Capacity (1000 Btuh) BF Bypass Factor NOTES: 1. Net capacities shown include a deduction for evaporator fan motor heat. 2. Contact manufacturer for cooling capacities at conditions other than shown in table. 3. Formulas: sensible heat cap. Leaving db entering db 1.09 x CFM Leaving wb wb corresponding to enthalpy of air leaving coil (h lwb ) total capacity (Btuh) h lwb h ewb 4.5 x CFM where h ewb enthalpy of air entering coil. 4. Direct interpolation is permissible. Do not extrapolate. 5. SHC is based on 80 F db temperature of air entering coil. Below 80 F subtract (corr factor x CFM) from SHC. Above 80 F db, add (corr factor x CFM) to SHC. SHC CORRECTION FACTOR ENTERING AIR DRY-BULB TEMPERATURE ( F) 79 78 77 76 75 Under 75 BYPASS 81 82 83 84 84 Over 85 FACTOR Correction Factor 0.10 0.98 1.96 2.94 3.92 4.91 Use formula 0.20 0.87 1.74 2.62 3.49 4.36 shown below 0.30 0.76 1.53 2.29 3.05 3.82 Interpolation is permissible. Correction Factor 1.09 x (1 BF) x (db 80) 5

SIZE 018 024 030 AIR DELIVERY (CFM) AT INDICATED EXTERNAL STATIC PRESSURE AND VOLTAGE EXTERNAL STATIC PRESSURE IN. WC BLOWER MOTOR 0.1 0.2 0.3 0.4 0.5 SPEED 208v 230v 208v 230v 208v 230v 208v 230v 208v 230v High 610 720 580 665 540 610 475 540 380 415 Low 480 580 450 545 415 500 375 430 320 340 High 895 985 860 955 825 915 785 865 730 805 Low 650 740 620 710 585 680 550 640 510 600 High 1160 1190 1105 1135 1050 1080 990 1020 935 960 Low 885 1025 870 985 835 940 810 890 770 840 NOTE: Data reflects a dry coil, filter, and 11-kw electric heater installed. Electric Heaters Dry-to-Wet Coil AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW AIR DELIVERY (CFM) 400 500 600 700 800 900 1000 1100 1-Element 5 kw 0.007 0.010 0.015 0.025 0.035 0.055 0.070 0.080 2-Element 7.5 & 11 kw 0.010 0.012 0.018 0.028 0.050 0.075 0.100 0.130 018 0.019 0.029 0.036 0.043 024 0.030 0.039 0.051 0.062 0.076 030 0.058 0.070 0.082 0.091 Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system. 6

Accessories HEATER PART NO. WITH TDR OPTIONAL FIELD-INSTALLED ELECTRIC HEAT PACKAGES* SIZES USED WITH NOMINAL KW @ 240V HEATER VOLTS PHASE (60 Hz) HEATER CAPACITY (MBtuh) 208V 230V KFDEH0801D05 All 5 208/230 1 14.3 17.2 5 KFDEH0901D75 All 7.5 208/230 1 20.7 25.0 6 KFDEH1001D11 All 11 208/230 1 29.7 36.0 6 APPROX SHIP. WEIGHT (lb) * Refer to the appropriate unit/factory-installed heater combinations in the Electrical Data tables for the electrical application data for these heat packages. Heater capacities shown here are for the largest size fan-coil unit and include blower motor heat. OTHER ACCESSORIES KIT NUMBER DESCRIPTION USED ON SIZES KFDCC0101DCC Cooling Control Package All KFBLG0106LGL* Louvered Wall Panel with Frame All * 6 pack ESTIMATED SOUND POWER LEVEL (dba) CONDITIONS OCTAVE BAND CENTER FREQUENCY* UNIT SIZE CFM Ext Static Pressure 63 125 250 500 1000 2000 4000 FF1-018 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 FF1-024 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 FF1-030 1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0 * Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, Chapter 52, p. 52.7. 7

SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG 1-800-644-5544 [ ] Packaged Service Training [ ] Classroom Service Training A94328 Copyright 2003 Carrier Corporation Indianapolis, IN 46231 2-03 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Page 8 Catalog No. 02FF-1D1 Printed in U.S.A. PC 101 Form FF1D-2PD Tab 3d 2e Replaces: FF1D-1PD