Innovators in Waste to Energy Products

WASTE WATER EVAPORATOR WITH ANY FUEL OPTIONS

Burner Comparisons. Typical Competitor s Burner

Solutions to Pollution

Suggested Specifications Prestige Excellence 110

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Completed Projects / Projets terminés

PACKAGED COMMERCIAL WATERTUBE BOILERS

Gas Equipment. Volume 4 June/July Issue date: June 25, 2008

Standard for tests for flammability of plastic materials for parts in devices and appliances

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

Listing of Water Heater Standards

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

INDUSTRIAL WATERTUBE BOILERS

Building Services Brochure

AFUE 95% Heating Input 50,000 to 200,000 Btuh

The world s standard in efficiency. CBEX FIRETUBE

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating

Canada s Experiences: Thematic Session on Wood/Solid Fuel Residential Heating

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

USER S INFORMATION MANUAL

CONTROL SYSTEM D ESIGN, E NGINEERING & C ONSTRUCTION.


AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Heating with Wood. Part 2

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

Engineered Systems. Complete combustion solutions that enable you to MAXIMIZE YOUR BUSINESS OPPORTUNITIES

Attention Docket ID Number EPA HQ OAR U.S. Environmental Protection Agency Mailcode: 2822T 1200 Pennsylvania Ave. NW. Washington, DC 20004

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

Design and Construction Standards SECTION PLUMBING EQUIPMENT

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Ontario Electrical Safety Code

Completed Projects / Projets terminés

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

BUSINESS PLAN CEN/TC 58 SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS EXECUTIVE SUMMARY

An Urgent Bulletin from CSA Group

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

Natural Gas Savings in Industry

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Energy recovery from exhaust gases using Heat Pipe technology

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

SolaGen Incorporated Process Engineering and Equipment. 150 Port Avenue St. Helens, OR Phone: Fax: Web site: solageninc.

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

PROPOSED October 15, 2013

d. Portable water heaters used exclusively for underwater diving operations.

Welcome!to!Central Boiler

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Residential/Commercial Gas Condensing Tankless Models

Crown Boiler Company

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

DIVISION FINNED WATER-TUBE WATER HEATERS

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

GAS SAFETY Information Bulletin

SECTION PLUMBING EQUIPMENT


Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Max-3 Steel Shell Boiler

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

ISO INTERNATIONAL STANDARD. Hydrogen generators using fuel processing technologies Part 1: Safety

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

Welcome to Central Boiler

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

What You Need to Know About UL rd Edition

OFFICE of the FIRE COMMISSIONER. Recreational Vehicles Life Safety Requirements

Pump Intake Design Ansi Hi Pumps

ASHRAE 2016 Boiler and Pressure Vessel Program Overview February 22, 2016

Revitalize Building Mechanical Systems (4619)

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Raypak Residential Products

Intelligent Heating for Your Home

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

BUSINESS PLAN CEN/TC 208 ELASTOMERIC SEALS FOR JOINTS IN PIPEWORK AND PIPELINES EXECUTIVE SUMMARY

Commercial Gas Water Heaters

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

CLEARANCES TO COMBUSTIBLES

Commercial Gas Water Heaters

Cata-Dyne LH Line Heater & Micro Line Heater

PCH Heating Condensing Module for Air Handling and Roof Top Units

Overview of Standards for CO Detection Products

Remote Alarm Panels Features

Transcription:

International, Inc. Innovators in Waste to Energy Products

History About INOV8 INOV8 was founded in the State of Wisconsin in 1990. The company manufactures a line of products that utilize patented burners that are fueled by nearly any type of fuel. The core products have been furnaces and boilers. INOV8 was the first in the industry to pair its burner with a boiler in 1992 and has successfully marketed this product since that time. Recent developments include a line of waste water evaporators capable of being fueled by natural or propane gas alone or in combination with a watery oil mixture or just waste oil, to eliminate or reduce volumes of dirty water. The latest product is a water heater capable of using fryer oil as its fuel and has an automatic backup to natural gas. INOV8 clearly produces a superior product in the areas of safety, clean burning, serviceability and overall quality and in the industry is recognized as the leader in the technology of waste oil combustion. 2

Background History Founded in 1990 in La Crosse, Wisconsin Developed & now manufactures a variety of heating appliances capable of burning waste petroleum or vegetable oil Products all products are fully tested & listed to US & Canadian safety standards 4 sizes of furnaces 12 waste crankcase fueled boilers 4 waste fryer space heating boilers 2 waste fryer domestic water boilers 3 waste water evaporators 2 sizes of waste oil burners 4 sizes of gas oil combination burners 2 sizes of steel oil storage tanks (any custom size available) A PLC (programmable logic control) for automation of fuel options Expertise combustion technology involving alternative fuels 3

Products Sold & Their Uses Thousands of furnaces burning waste lubricating oil, hydraulic & transmission fluids, gear lube, diesel, mineral oil, solvents, jet fuel, fuel oil, gasoline & natural gas or propane. Hundreds of boilers burning all of the above waste petroleum oil, or gas oil in combination. Many customers burning waste fryer oils for heat or hot water for over ten years in furnaces & boilers. Evaporator customers burning waste coolant oil, marine bilge water with oil, waste lubricating oils eliminating disposal costs. 4

Since 1990 INOV8 Has Developed Many Firsts in our Industry First to use aluminized steel, ceramic target, hinged burners, digital temperature control, first with a website, extended warranties High BTU Burners (up to one million) Hot water & Steam boilers burning waste oil Make up Air Furnace High efficiency waste oil furnaces (83 to 85%) Waste Water Evaporator fueled by waste oil Specially designed oil storage tanks (to provide best oil to burner) Using Vegetable Oil as fuel Dual fuel Burner for water based oil Dual fuel Burner for fryer oil Controls to provide automatic backup Water heater fueled by fryer oil 5

Safety Certifications & Approvals Multi fuel Oil Burners Model S200 & S700 Burners Tested & Listed by Intertek ETL Semko, Test Report #3120734 CRT dated March 7, 2008, to: ANSI UL296, Issue 1994/06/01, Ed:10 Rev:2006/02/24, Standard for Safety Oil Burners; CSA B140.0, Issue: 2003/10/01, Ed:3, General Requirements for Oil Burning Equipment General Instruction No 2 4 (R1991). Gas Waste Oil Series: G200, G400, G750 & G900 Tested & Listed by Intertek ETL Semko, to ANSI Z21.17*AEI Domestic Gas Conversion Burner Issue: 1998/01/01, CSA 2.7 M98, UL296A*AEI UL Standard for Safety Waste Oil Burning Air Heating Appliances Issue: 1995/10/31 Ed:2 Rev: 2006/03/08, CSA B140.0*AEI General Requirements for Oil Burning Equipment General Instruction No 2 4 (R1991) Issue: 2003/10/01 Ed: 3, CSA C22.2#3*AEI Electrical Features of Fuel burning Equipment General Instruction No 1 2 (R1999) Issue: 1988/01/09 Rev: 1999/01/01. PLC Control Panel Tested & Listed by Intertek ETL Semko, to UL873 Temperature Indicating & Regulating Equipment. U.S. Patents: #5,149,260 & #5,341,832 & other patents pending Furnaces Models: F125, F240, F240SC & F450 Tested & Listed by Intertek ETL Semko, Test Report #3120671 CRT 001 dated July 16, 2007, to: For United States installations: Underwriters Laboratory 296A Waste Oil Burning Air Heating Appliances 2nd edition dated October 31, 1995 with revisions through and including March 8, 2006. For Canadian installations: B140.0 03 Oil Burning Equipment: 3rd edition General Requirements published in October 2003, and B140.4 04 Oil fired Warm Air Furnaces published in September 2004, 3rd edition, and Oil Burners: Atomizing Type CSA B140.2.1 M90 Dated July 1990. Tested by PFS Corporation, Test Report #90 39 dated March 6, 1991 and #93 10 dated February 24, 1993, to Underwriters Laboratory Standard 296A Waste Oil Burning, Air Heating Appliances (now expired). Tested by Underwriters Laboratories of Canada, File #CMP239 to CSA Standard B140.4 1974, Oil Fired Warm Air Furnaces and the CSA Interim Requirements for Appliances Burning Used Oil in an Atomizing Burner (T.I.L.) No. R 1 and CAN/CSA Standard B140.2.1 1987, General Requirements for Oil Burning Equipment (now expired). Registered with European Economic Community under Registration No. 3884/1997 Wisconsin Material Approval File No. FN 91 129 (now expired) Energy Star Rating on Model F125 Furnace Tank(s) Tested & Listed by Intertek ETL Semko, Test Report #3120672 CRT 002 dated May 2, 2007, to: For United States installations to UL Standard 80 for Steel tanks for oil burner fuel, eleventh edition dated August 19, 2004, and For Canada installations to CAN/ULC S602 03 Aboveground steel tanks for storage of combustible liquids intended to be used as heating and/or generator fuels. PFS Listing #92 37 dated 2/22/1993 Above Ground Steel Bench Tank tested to UL 142 Standard, Steel Above Ground Tanks for Flammable and Combustible Liquids (now expired) Buderus, Viessmann & Triad Boilers Built in accordance with the requirements of the ASME Boiler and Pressure Vessel Code IBR Listed Energy Star Approved (when appropriate) 6

Competitive Advantage Unblemished safety performance record Unlimited fuel options Clean combustion Options for type of heat: hot water or domestic or space heating Options for configuration & BTUs Patented technology 7

Some Benefits of Used Oil as Fuel versus New Fuels Reduces customers energy costs for heating facility, Reduces consumption of foreign fuels, Reduces greenhouse emissions by reducing use of fossil fuels, Eliminates messy storage & disposal costs, Emissions from biofuels are carbon neutral with reduced CO, CO2, NOx & no SO2, All equipment has a short pay back period, and Most equipment has 20 year (or more) expected life. 8

INOV8 Products: Furnaces, Boilers, Evaporators & Water Heaters all fueled with used oil. Economic, Environmental & Energy Savings 9

Customer Testimonies From: Parchert, Jim [mailto:jparchert@pac power.com] Sent: Monday, May 10, 2010 12:08 PM Subject: another heating season over. Another heating season is now behind us and I just wanted to let you know that the boiler system worked without a single problem. We have found that we need to have the boiler cleaned of ash twice a season. During the last cleaning it was noted that the door insulation needed to be patched as it had begun to break on the edges so I had that done but beyond that we had no additional repair costs beyond normal cleaning and service. The switch to the dual fuel gas/oil burner made all the difference in the world as far as reliability is concerned. Jim Parchert Corporate Facility and Environmental Mgr Pacific Power Products Ridgefield, Washington 98642 10

Customer Testimonies December 15, 2009 Hi Rebecca, This is Mark Uher from the Ridgetown College. Stu Porter had said that you had a couple of questions about the boiler fuel and approval. The fuel that we are using is biodiesel that we have produced ourselves at the plant. It seems to be working very well in our boiler (other than the start up draft issues which we're working with a local HVAC group to remedy). The approvals are going well. We had a couple of people from the Ministry of Environment give us a temporary work order to use our boiler until our Certificate of Approval gets approved. They saw no issues with using it and the dispersion modeling that we had done for it (as well as other reasons) showed that everything was just fine, which is what we expected. So we are happy with the boiler as well as with Inov8 and really appreciate all your help. If there is anything else please don't hesitate to get in touch. Thanks and have a great day, Mark Uher Ridgetown College University of Ontario Guelph, Ontario 11

Readers Digest September 2004 Glenn has heated his house, several greenhouses, and his shop with used fryer oils from Philadelphia restaurants since 2003. He claims that he wouldn t be in his business without this energy savings. 12

Customer Testimonies 13

INOV8 s Vision To provide consumers options for energy savings. To fully utilize energy from waste products. To produce products that reduce greenhouse emissions. To continue the development of alternate fuels until they are no longer considered alternates. To reduce US dependency on foreign fuels. To produce the safest, most reliable, innovative heating systems available. 14

INOV8 Burners Provide Solutions to Pollution Eliminate wastes Eliminate or reduce heating costs Reduce consumption of new fossil fuels Economic, Environmental & Energy Savings 15