templine electrically heated hoses with with system system options options

Similar documents
templine electrically heated hoses with with system system options options

Heating Mats and Jackets. innovations in heat tracing

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

NT 35/1 Tact Te. Tact system (Tact Automatic Filter Cleaning System) Ideal connections. High-quality, robust equipment.

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

NT 65/2 Eco Me. On-board storage. Integrated drain hose (oil-resistant)

NT 75/2 Ap Me Tc. On-board storage. ApClean (semi-automatic filter cleaning system) Integrated drain hose. Hose and bend attachment

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Heating Cables and Tapes. Technology. Constant wattage tapes

NT 40/1 Tact. Robust bumper. Ergonomic push handle

Wet and dry vacuum cleaners NT 65/2 Eco

NT 65/2 Tact² Tc. Tilting chassis with container lock. Suction tubes and floor nozzles can be stored in any direction in the accessory holders

NT 75/2 Ap Me Tc. On-board storage. ApClean (semi-automatic filter cleaning system) Integrated drain hose. Hose and bend attachment

NT 35/1 Ap. NT 35/1 Ap, ,

Wet and dry vacuum cleaners NT 70/2 Adv

NT 35/1 Ap. ApClean (semi-automatic filter cleaning system) Practical cable storage compartment. Mobility and power

CABLE & HOSE PROTECTION PRODUCT OVERVIEW

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

DUCTING & VACUUM HOSE

Wet and dry vacuum cleaners NT 70/3

Safety vacuum drying oven for flammable solvents

NT 611 Mwf. Integrated accessory storage. Integrated wastewater pump. Large bumper with accessory storage.

Wet and dry vacuum cleaners NT 70/3

Advantages / Characteristics

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

Capacitive Sensors with a body that is in excellent shape - The 26 Series

F1202 TRACE HEATING. Road & Ramp

flexaflex Flexaflex Hoses International

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Wet and dry vacuum cleaners NT 65/2 Tact²

Silicone Heaters and heating foils

FLEXIBLE CORRUGATED TUBE

PIPE MANUFACTURING CO.

Wet and dry vacuum cleaners NT 65/2 Ap

Cold water compact class HD 5/12 C

FCHM Hydromatic Pump Control Module

Cold water compact class HD 5/12 C

NT 40/1 Tact Te. Robust bumper and chassis. Ergonomic push handle

ANTI-CONDENSATION HEATERS

Paddle Flow Switch. Pressure Control Flow Switch

Frost Protection Thermostat

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Installation and operating instructions. DK energy storage and DK energy buffer

Wet and dry vacuum cleaners NT 35/1 Tact (240V)

NT 35/1 Tact. Multi-purpose wet & dry vacuum cleaner with Tact automatic filter clean system for heavy duty dust extraction.

Electrically Heated Sample Lines Type 3/4/5-N/M/H (Ex), PSP 4M(-W), Type 3/4/5-5/30/50/80/100/120 (Ex)

Cold water compact class HD 5/17 C

Sensor and transducer cables

VC-1, VC-1-SL, VC-2-L, VC-2-SL

Vertical Centrifugal Coater VCC

NT 65/2 Tact² Tc. Tilting chassis with container lock. Suction pipes and floor nozzles can be stored in any direction in the accessory holders

Wet and dry vacuum cleaners NT 25/1 Ap

NT 45/1 Tact. NT 45/1 Tact, ,

ELECTRIC HEATING. we get to the point... Gräff GmbH Bonner Strasse 54 D Troisdorf Tel: +49(0) Fax: +49(0) ISOMA

Gentle Delivering and Metering Hose Pumps DULCO flex for Applications in Laboratories and Industry

Energy Saving Band Heaters

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Documentation. Parallel Heating Cable. Type: ELP

The DAUREX Quick Clean Pumps

SOLAR SYSTEM. We follow the sun.

The Safest Connections...

Xpert HD Xpert HD 7140, ,

Here is your conveying solution: Product group D.

Cold water HD 9/18-4 ST

FOOD - PHARMACEUTICAL Industrial Vacuum Accessories

Cold water compact class HD 5/17 C Plus

SuperMagnum 270 ELC Hot Water High-Pressure Cleaner

Cold water compact class HD 5/15 C

NT 35/1 Tact Bs. The vacuum cleaner for bakeries. Heat-resistant PES flat pleated filter

Cold water compact class HD 5/12 C Plus

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

AKOCABLE Heating Cable Solutions Electrical Tracing

Micro/Ultra Filtration System StamoClean CAT 430

Chemical Pumps Vertical Chemical Pump Type TNP

Infrared Modules for Industrial Processes. Heraeus Noblelight

Infrared Modules for Industrial Processes. Heraeus Noblelight

NT 35/1 Tact (110V) Multi-purpose wet & dry vacuum cleaner with Tact automatic filter clean system for heavy duty dust extraction.

BAND HEATERS component parts

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

HD 5/12 C + Mobility. Accessory storage

VACUUM VALVES AND HOSES

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

A.YITE GROUP (Hongkong & Shanghai)

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Cold water compact class HD 6/13 C Plus *EU

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Cold water compact class HD 6/15 CX Plus

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Flow Switches. Series VHS, VKS, VH

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

HD 7/11-4 Cage Classic

Heated tools. Semiconductor equipment

Cold water compact class Xpert HD 7125 *AU. Standard accessories: High-pressure hose 10 m Spray lance 380 mm Anti-twist system Pressure cut-off

High pressure cleaning heads cleanliness all around

Bench-Top Vacuum Oven with 28 segments programmable controller

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Freezertech Horizontal Plate Freezers Engineered for capacity

Transcription:

templine electrically heated hoses with with system system options options Economical Flexible Optimum Ready for use Reduce your energy by up to 30 % in comparison with conventional systems Extremely bendable in all directions (360 ), torsionally resistant Uniform and consistent heat distribution over the entire surface of the hose Fully assembled, with only one connection line

Introduction templine heated hose: it all began with an idea! How can high quality hoses be heated electrically using efficient and advanced technology? Not an easy question, and initially it proved difficult even for an experienced developer and manufacturer of hoses. A heated hose system which really would meet the full range of demands of actual practice called for an entirely new technical approach. The templine patented heated hose system is the answer. The design of templine is based on the concept of flexibly and reliably transferring fluid, granulated and gaseous media in a temperature-controlled environment between two fixed points. The templine design, consisting of a flexible hose (for transferring the required material), a new heating concept, thermal insulation and an outer casing, is very closely adapted to everyday operational needs, as well as those of system maintenance and upkeep: High mechanical resistive strength protects the material-transfer hose in the inner core against the effects of being trodden on, run over by vehicles, or friction wear of the outer casing due to the hose being dragged over rough ground. Uniform heating of the material being con- veyed prevents it from becoming overheated and being destroyed. The following paragraph outlines the new patent-protected technology of the templine heated hose system: A fabric braiding encompasses the surface of the material-transfer hose. The heating conductors are woven into this braiding in a helical fashion which means that, together with the fabric, they follow every movement of the hose and maintain permanent contact with it even under extreme bending or rotation. That guarantees the unhindered flow of heat produced in the conductors. The templine design is the result of the consistent application of the experience gained by users: 100 % heat transfer, 100 % reliability and all this with up to 30 % energy saving thanks to a heating system with optimum degree of efficiency and highly effective thermal insulation. Universal in concept. Individual in use and application. The templine heated hose system by Masterflex. 2 MASTERFLEX August 2018 -

templine templine Braid/carrier fabric of templine heated hoses MASTERFLEX August 2018-3

Areas of application The core competence of templine Characteristics Due to their specific properties, flexible heated hoses are designed for processes in which, as well as the conveyance of fluid, gaseous, or granulated media, extreme bending and torsion movements must be withstood without any damage over the long term. Small Town Studio - istockphoto.com In automobile production, robots coat body parts with a fluid wax preservation coating TTstudio - fotolia.com Other typical demands: materials conveying foodstuffs Chemically resistant hoses for transferring Suitability of the material-transfer hose for Pressure resistance up to 500 bar High operating temperatures of up to +300 C Mechanically tough hose casings Range of operational voltages Industrial installations impose a whole range of demands on an electrically heated hose. These include, in particular, areas subject to the risk of explosion, high operating temperatures, and operational pressures of up to 500 bar 4 MASTERFLEX August 2018

Potential applications Basically, electrically heated pipes and hoses fulfil the same purpose. Where they differ, however, is flexibility. A hose connects two points with each other in a flexible manner, which means that the connection remains intact when one of the points, or even both, change position. If this hose is equipped with an electrical heating system, media being transferred can be protected against frost, retain their temperature, or be heated up. This is particularly interesting for applications in the chemical or petrochemical industries, food production, or the manufacture of cosmetic products. Some examples of typical applications for electrically heated hose systems: Paint & Coating Technology Processing of waxes Coating hoses, e.g. for 1K / 2K machines PUR / in-situ foam and polyurea machines Bitumen Processing Wax-conveying hoses, heating capacity 60-120 W/m. Heating with minimized tolerances to guarantee extremely uniform consistency Shaping/adhesive bonding of plastics Vehicles for the production of road surfaces, equipped with templine heated hoses for bitumen transport. Heating capacity: 220 C CNC-controlled injection moulding machine. Temperature-controlling the plastic and adhesive in the heated hose during manufacture of housing parts (PA, TPE, EVA). Temperature of medium: +90 C to + 180 C Plastics processing Fire-extinguishing water distribution system Co-extruding plastics. Conveying fluid plastic granules to the extrusion mould in heated hoses. Optionally: Temperature-monitored extrusion head with integrated sensor in the mould head. Heating capacity: 60-140 W/m Heated hose (nominal diameter 50) for connecting storage tank and extinguishing water distribution system. Function: Protection against freezing (+ 5 C) outdoors. Material-transfer hose made of polyethylene MASTERFLEX August 2018-5

Structure of the templine heated hose The design structure and its variants The illustration shows the new design concept of the templine heated hose in comparison with conventional versions. The templine heated hose provides technical solutions to meet real, practical expectations. Braiding / carrier braid with embedded heating conductors Heating conductors: - PTFE insulated (medium up to 200 C) - Fabric-insulated (medium up to 300 C) Casing: - Polyamide braiding - KEVLAR braiding - PUR spiral hose - HYPALON spiral hose etc. Thermal insulation: - Closed-cell insulation hose - Silicone-free thermal fleece Material-transfer hose: - PTFE smooth hose (single/double/multiple pressure-reinforced up to max. 500 bar) - Metal hose - Vacuum-resistant hose, up to 20 mbar Section and cross-section of a templine heated hose 6 MASTERFLEX August 2018

Structure of the templine Basic heated hose The picture shows the structure of the templine Basic heated hose for simple applications. The templine Basic heated hose offers technical solutions for the real-life problems. Heating Cables: - PTFE insulated (up to 200 C Medium) - Fabric insulated (up to 300 C Medium) Medium-transport hose: - PTFE smooth hose/tube (single/double/ multiple pressure-reinforced up to 500 bar) - Metal corrugated hose - Vacuum-resistant hose Structure of the templine VARIO heated hose In the event of obstructions (due to deposits/dirt) or damage, it is possible to exchange the inner hose (the so-called inner core ) quickly and easily. An intelligent hose in hose system makes this possible. Braiding/Carrier Fabric with incorporated heating cables Heating Cables: - PTFE insulated - Fabric insulated Outer Cover: - Polyamide braiding - KEVLAR braiding - Spiral hose of PUR, TPV, PVC and other materials Inner Core: - Removable hose for medium transport Thermal Insulation (heat insulation): - Closed-cell insulation hose - Silicone-free thermal fleece MASTERFLEX August 2018-7

templine VARIO with hose bundle Possible removable hoses/tubing in the templine VARIO design: Plastic hose/tube made from PVC, PU, PE, PTFE, etc. Single pressure-reinforced hoses/tubes Triple pressure-reinforced hoses/tubes Advantages of templine VARIO heated hoses: Simple replacement of the internal hose in the event of damage or obstruction (due to deposits or dirt) Fast and cost-effective recommissioning of the entire heated hose system Inner tubes can be system compatible, e.g. made from: polytetrafluoroethylene (PTFE), polyamide (PA) or polyurethane (PUR) Inner tubes with a diameter from 2 to 25 mm possible Multi-lumen tubing can be used as inner hose Tube bundles can be used as inner hose 8 MASTERFLEX August 2018

Technical data The special way in which the heating conductors are processed into the hose braiding optimizes the heat transfer. This means that, even with severe bending or torsional movement, contact between the heating conductors and the surface of the hose will be ensured at all times, and prevents overheating (also referred to as hot spots ). Here is a direct comparison of heated hose systems: Conventional heated hose: Parallel heating strips as heat conveyors templine heated hose: Heating conductors as heated hose Other major features of the templine heated hose system: Highly effective thermal insulation means up to 30 % energy saving independent institutes in Germany, approximately 1,000,000 test cycles) uniform heat distribution along the hose Choice of ageing-resistant materials guarantees long service life Optional: Anti-static/friction wear-resistant casing Extremely flexible hose structure, resistant to bending and torsion (proved by tests by Temperature of the medium can be monitored within very narrow tolerances, thanks to the Optional: Fitted with integrated temperature controller/temperature limiter Operational voltages range between 6 V and 400 V in single-phase and three-phase mains operation Technical Data Basic data: Hose design: single material-transfer hose/interchangeable inner hose Inner diameter: DN 4 to DN 200 Pressure resistance: Depending on the rated width, up to 500 bar possible, other values upon request (guide values at +20 C) Connection housing: Hard shell/epdm cap (silicone-free format) Thermal insulation: Silicone foam/thermal nonwoven fleece Protection class: I (protective earthing) Protection mode: IP44 / IP65 Nominal voltage range: Up to 400 V Nominal power: Up to 500 W/m Heated hose lengths: Up to 100 m (higher values on request) Conformity: CE MASTERFLEX August 2018 9

Construction Overview of design versions Three designs allow you to select the templine heated hose system based on the process. templine -A Basic version for direct connection of the heated hose to an external energy supply, as well as an external temperature control. Temperature sensor cables and power cables run separately in the connection cable and are colour-coded. In addition to a two or threewire PT100 sensor, this version also has a thermo-couple option (NiCr-NiAl (Type K) or Fe-CuNi (Type J)), as well as NI100, NI120 or PT1000. The end connection and connection housing are made of impact-resistant, fibrereinforced plastic. Fittings are adapted individually depending on the application. templine -R Heated hose with integrated temperature controller in the connection housing. A clear cover with window provides a view of the target value setting and signal lights. The power supply is secured via a flexible cable. Temperature sensor: PT100. The end connection and connection housing are made of impactresistant, fibre-reinforced plastic. templine -B Heated hose with integrated temperature controller and safety temperature limiter in the connection housing. A clear cover with window provides a view of the target value setting and signal lights. The power supply is secured via a flexible cable. Temperature sensor: PT100 (regulator), PT100 (limiter). The end connection and connection housing are made of impact-resistant, fibre-reinforced plastic. 10 MASTERFLEX August 2018

templine -F Heated hose with integrated frost protection (bi-metallic switch). No expensive external regulator required. Structure includes fully electric heating conductors and no vulnerable heating bands. The heated hose keeps the temperature of the transported medium at approx. 5 C, even at very low environmental temperatures. templine -H Insulated hose line for maintaining the medium temperature without electric heating, up to 250 C. MASTERFLEX August 2018-11

Construction templine Special designs for special requirements The heated hose system also offers variants for larger rated widths (32 to 65 mm) and special operating conditions. As the inner diameter of the inner hose increases, so too does the mechanical stress on the hose components inside the templine system. Specifically, in the course of bending and torsional stress, tensile and compressive forces are incurred and, depending on the bending and torsional loading, these forces can lead to accelerated ageing of the heated hose. In many cases, transferring materials in this way requires high pressure resistance values along with high flexibility. And when heated hoses with large dimensions are being used such as, for example, when bitumen processing in machines for road repairs, even external influences come into play. These hoses are subjected to high vibrations, increased wear of the outer casing due to friction rubbing against surfaces, or stress loading from being trodden on during operation. Masterflex has paid special attention to these particular applications in the further development of the templine heated hose system. And the result is the heavy-duty series of templine heated hose systems. Features of these formats: Tough, pressure-reinforced and vacuum- resistant medium hoses, in part with single/ multiple steel wire braiding Multi-layer thermal insulation formed from closed-cell wear-resistant silicone foam with low thermal conductivity coefficient (λ<0,025 W/mK) fabric to increase flexibility Intermediate layers made of high-quality Ageing-resistant and wear-resistant casing (ARAMID/KEVLAR fabric, spiral hose with Teflon textile fabric, steel/stainless steel braiding) Connection cap and end cap optionally made of fibre-reinforced impact-resistant plastic, and, optionally, designed as polyolefin cap. benjaminnolte - fotolia.com Vehicle for making roadway surfaces: templine heated hoses for transferring the bitumen (+220 C) 12 MASTERFLEX August 2018

Components templine heated hoses Selection of hose components The structure of templine heated hose systems takes full account of the operational conditions within an installation or a process. The systems are individually planned by Masterflex. Individual components can be selected from a range of different design formats. Material-transfer internal hose Pressure values at +20 C rated reference temperature. Beware influence of temperature on pressure resistance! PTFE hose Inner diameters: DN4 DN50 Pressure resistance: up to 22 bar Suitable for contact with foodstuffs (standard inner hose) PTFE hose with pressure reinforcement Inner diameters: DN4 DN25 Pressure resistance: up to 264 bar Suitable for contact with foodstuffs PTFE hose black electrically conductive Inner diameters: DN4 DN25 Pressure resistance: up to 264 bar Suitable for contact with foodstuffs PTFE hose with triple pressure reinforcement Inner diameters: DN4 DN25 Pressure resistance: 500 bar Suitable for contact with food-stuffs Good flexibility PTFE hose with pressure reinforcement Inner diameters: DN6 DN200 Pressure resistance: up to 172 bar Suitable for contact with food-stuffs High flexibility Metal hose with vacuum resistance Inner diameters: DN6 DN200 Pressure resistance: up to 90 bar Vacuum-resistant Good flexibility MASTERFLEX August 2018-13

Components Hose connections (fittings) for connecting the templine hose system. Optionally available in steel or stainless steel. Standard connection With 24 outer cone and union nut, with metric internal thread Hose connection with flat seal Union nut, with metric / BSP / NPT internal thread Pipe connection For connecting the heated hose by clamping ring and union nut Hose connection with external thread Flat sealing or with internal cone (24, 60, 74 ), with metric / BSP / NPT thread Special connector Type: KAMLOCK. Illustration is of female/male format All other connection variants (flange, Tri-Clamp, etc.) are possible on request. 14 MASTERFLEX August 2018

Materials Casing There are a wide range of casings available to protect the templine heated hose against mechanical influences: for example: Polyamide fabric Wear-resistant, UV-stable, flexible, black, (standard) Master-PUR L Food Extremely wear-resistant, food-grade quality PUR L-EL spiral hose Mechanically tough, UV-resistant, crush-resistant & recoverable Master-SANTO SL Flexible, resistant to temperature MASTERFLEX August 2018-15

Control systems templine Limiting/controlling temperature In order to monitor flowing media in electrically heated hose systems, whatever the operating mode - protection against freezing, maintaining of constant temperature, or temperature increase - the use of an electronic control system is always recommended. An important factor in this situation is matching the controlling behaviour to the heat being transferred by the electrical heating system. Both systems templine -R and templine -B offer the possibility of direct integration of controllers or controller/limiters into the heated hose connection. This has the advantages of saving space, offering precision and requiring no maintenance. a) Integrated temperature controller templine -R Electronic temperature controller, PI control characteristic, system deviation +/- 1K. Sensor input: PT100, two/three conductor technology Switching capacity: 1360 VA/ 6A Nominal voltage: 230 V ~ (standard) templine -B Electronic temperature controller with integrated temperature limiter (safety temperature limiter) PI control characteristic, system deviation +/- 1K Sensor input: PT100, two/three conductor technology Switching capacity: 1360 VA/ 6A Nominal voltage: 230 V~ (standard) Anti-freeze switch Automatic resetting Switching capacity: 690 VA/ 3A Nominal voltage: 230 V- (standard) 16 MASTERFLEX August 2018

Technical data for templine -R and templine -B: Housing protection class: IP65, protection class II Electromagnetic compatibility according to EN61326 Setpoint temperature control range 0 C - +250 C. Temperature limit value range 0 C - + 250 C Nominal voltages (optional) 12 V =, 24 V =, 48 V =, 62 V =, 115 V ~ Signal lights for nominal voltage, operation heating and sensor break/sensor short circuit b) External temperature controller external digital controller TD 7000 Electronic temperature controller with digital display, 2-point or PID control characteristic options. Adjustment range 0...250 C Sensor input: PT100, two-/three-wire technology (optional FeLuNi, Ni100, NiCrNi) Switching capacity: 3680 VA Nominal voltage: 230 V (other voltages optional) Protection class: IP54 external analogue controller T 7000 Electronic temperature controller PI control characteristics Setting range 0...100 C Sensor input: PT100, two-/three-wire technology Switching capacity: 2200 VA Nominal voltage: 230 V (other voltages optional) Protection class: IP54 MASTERFLEX August 2018-17

Project Checklist Electrically heated hoses from the templine product range are individual solutions, and the calculations behind them are derived from the data from the user. Please complete this form as fully as possible, since this will enable us to prepare the best possible product solution to suit you. Fax: +49 (0)209-97077-33 Tel.: +49 (0)209 97077-94 templine@masterflexgroup.com Contact Data Company: Street: City/Postal Code: Contact: Function: Departement: Phone: Fax: Cell Phone: E-Mail: Description of Application Hose Inner Diameter (mm): Hose length (m): Vacuum (mm water head): Medium Type: granules gaseous liquid viscous Medium Temperature ( C): Critical Medium Temperature ( C): Wind (>2ms/s): Yes No Config. of templine -A (external Supply) heated hose: templine -R (controller) templine -F temperature control templine -B (with temperature limiter) Other (mm): Pressure (bar): Number of Hoses: Medium: Start-up Temperature ( C): Ambient: Indoor Area Outdoor Area Humidity/Fog: Yes No Application: frost protection maintain temperature increase in temperature Customer required load (W):: Operating Voltage: External Effects: tensile-/compressive-stress permanent frost condition direct solar irradation Hose Configuration Inner-/Medium hose: PTFE PTFE pressure max 264 bar PTFE pressure max 500 bar PTFE-corrugated hose PTFE-corrugated hose reinforced Metal corrugated hose Metal corrugated hose reinforced Other: silicone free: Yes No Thermal Insulation: Silicone Foam Fleece (silicone free) Hose fitting material: steel brass stainless steel 18 MASTERFLEX August 2018

Design: Swivel Nut, 24 -Cone, metric BSP-conical Outer Thread, 24 -inner cone metric BSP-conical Swivel Nut, 60 -cone metric BSP-conical Swivel Nut, flat-sealing metric BSP-conical flat-sealing/outer Thread metric BSP-conical Replaceable Inner-/Medium carrying- hose: Yes No Protective PA-Braiding KEVLAR-Braiding Master-PUR L-EL Master-PUR L Food jacket: HYPALON-Spiral hose Stainless steel braiding Silicone outer coating Master-SANTO SL further protective jackets on request Mechanical stress: Yes No Problem definition: Type of installation: Stationary installation medium strength movement high tensile / bending movement Approvals/Certificates: MASTERFLEX August 2018-19

Masterflex SE Willy-Brandt-Allee 300 45891 Gelsenkirchen, Germany Tel +49 209 97077-0 Fax +49 209 97077-33 www.templine.de templine@masterflexgroup.com A MASTERFLEX GROUP COMPANY MASTERFLEX August 2018