TTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity

Similar documents
TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Ceiling swirl diffusers

CONDOR. Supply air ceiling QUICK FACTS

Ceiling swirl diffusers

Ceiling diffusers. Type DLQL

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Consultant Specification AGILE Wireless Fire Detection System

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

Halton Rex for Vario R6O - Variable air volume chilled beam

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

System technology. Demand controlled ventilation WISE.

Units for suspended ceilings

Blower-YEFB-020-3R-1maxVel

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

VAV CHILLED BEAMS Pi FUNCTION DESIGN GUIDE

Accuracy by Design Products for the HVAC Professional

CHILLED BEAM CASSETTE IQ STAR LYRA

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

iq Star LYRA II chilled beam cassette

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

Hydronic & HVAC Control Systems

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Pre-programmed room controller with communication

Predator Controller Hardware Family

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Toxic Gas Detection. Model F12. Toxic Gas Detection

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

Pre-programmed room controller with communication and hidden setpoint

SIMPLICITY FULL MODULARITY?

(This foreword is provided for information only and is not part of the draft addenda.)

APPLICATION DATA SHEET

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

APPLICATION DATA SHEET

SYST0101CW Product Specifications

Halton CHB Active chilled beam with boost function for bulkhead installation

Polaris-I-60. active chilled beam. the future of space conditioning

Pre-programmed room controller with communication

Units for suspended cei lings

KLIMA Active Chilled Beams

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

iq Star LYRA II chilled beam cassette

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

NS Series Network Sensors

Integrated Process Solutions. Series 49. Thermal Management System

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

MECHANICAL SERVICES 101. Ian White

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

OPTISENS TUR 2000 Technical Datasheet

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

Better Design, Better Control, Better Systems.

HOTEL CHILLED BEAM IQ STAR SILENCIA

b.) Technical Information:

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Energy Savings with Direct Digital Control

IGD.CO.UK

Room controllers with manual forced ventilation function

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

DIGITAL CENTRALIZED Section NANOMASKIT

CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER

Application Manual LT-6617 Rev. 1 July 2017

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Home. evohome multi-zone, Lyric T6 programmable thermostat and Single Zone thermostat. Smart Heating Controls THE COMPLETE CONNECTED CHOICE

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Model 8682-KET Sequenced Offset (Flow Tracking) and Static Pressure Controller with Dual Exhaust Modulation for Temperature Control

Halton Rex 600 Basic R6B - Active chilled beam

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX

SIMPLICITY OR FULL MODULARITY?

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Flexit air handling units UNI 2, 3 og 4

Autronica Fire and Security AS ID:

Model D12-IR. Digital Gas Transmitter...

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Job Name Control Systems Description Date

Air distribution systems. Opticlean OC-Q...

Orion-LØV LØV-R with Sirius

Linear Floor Heaters

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Transcription:

Introduction is a ceiling mounted supply air device with integrated electronics for room climate control. The design allows for a maintained high injection rate and thus mixing of room air even at low airflows. The result is, in addition to energy and environmental gains, a lower noise level and a draft-free regulation. s integrated functions include: Demand control of airflow based on occupancy/ temperature/co 2 Sequential adjustment of cooling and heating Lighting system control Economy mode Multiple available interfaces for communication and downloading values of control variables is connected to a combined voltage feed and communication loop via Lindinvent's standard cable with two conductors for voltage feed and two twisted-pair conductors for communication. Energy saving potential Compared with a conventional CAV system, considerable savings in energy usage can be achieved for: Supply air heating Fan power Cooling energy Radiator heating Lighting power Connections is connected to the voltage feed and communication loop via connection box CBX, which can be mounted directly on the plenum box or located as desired. A number of items of equipment/functions can be connected to via CBX. 24VAC + Communication 24VAC + Communication - The active, ceiling mounted supply air diffuser. Simplicity has been designed with the focus on simplicity, installation and operation: Built-in control electronics and sensors. Factory calibrated. Minimized building measurements and several installation options. Downloading and setting of control variables is done wirelessly via handheld DHP or via connected communication network. Renovation and rebuilding The flexible system solution is very cost-effective for rebuilding or renovation work. Walls can be installed or moved without having to reroute ducts or cables. Existing CAV systems without cooling can be converted to VAV air conditioning systems by installing diffusers and isolating existing duct systems. Active supply air diffuser Plenum box HTK SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Lighting control box CBR AIN Adjustable function Active supply air diffuser with connection box CBX AOUT Adjustable function 24VAC Comm. Connection box to active diffuser CBX 230VAC AOUT/IN Control boxes Valve actuator A40405 Type solution - Cell office with. Connection diagram with connection box CBX. The diffuser is connected to the voltage feed and communication loop and other equipment via connection box CBX. _A30_PB302_eng_NGP 1(6)

Function is a ceiling mounted supply air diffuser with variable slot opening. The slot height is controlled by a motor that opens or encloses a number of slots, which permits higher pressure drop at lower noise levels. The diffuser has a high injection rate and maintains the mix of under-temperature supply air over the entire flow interval. Pressure and flow sensors The diffuser has a built-in air pressure and air flow sensor. Temperature sensor is equipped with room and duct temperature sensors. The room temperature sensor is located at the edge of the device where it measures the room air in the living zone. The location of the room sensor at the device is more representative and faster than a wall mounted sensor. Occupancy detector Adjusted levels of airflow and lighting control are some of the functions that can be activated via the integrated occupancy detector; for details see the product description for XPIR. IR link Reading settings, actual values etc. can be done via the hand held user panel DHP. Network communication is connected via node ID to a communication loop (CAN). Concurrent nodes are connected to the same physical loop. The communication loop is in turn connected to Gateway NCE, which represents the bridge to the superior system. Calibration is pre calibrated with high precision in the factory. Network settings, balancing zones and the like are adjusted in the system on site. Alarms has a number of built-in alarms and can alarm via network communication. User interface The following user interfaces are available: Wireless connection via user panel DHP Server with web interface LINDINSPECT (applies to systems with LINDINTELL) Communication with external systems Communication with is set up over Modbus TCP or Modbus RTU. Via server in system solutions with LINDINTELL Via Gateway NCE in system solutions without LINDINTELL LINDINTELL/LINDINSPECT LINDINTELL is a software package that is installed on a central server. LINDINTELL has among other things functions for optimization, override and free programming. LINDINSPECT is a Web interface developed for use with LINDINTELL. Corridor Korridor Example of a start page and its instrument panel in the web interface LINDINSPECT. Nodes in the system for climate control can be monitored and administered via LINDINSPECT. DCV-BL Functional chart : The supply air flow from a number of active diffusers is summed up via network communication and balanced via airflow control unit DCV-BL. _A30_PB302_eng_NGP 2(6)

Installation options Generally is designed for horizontal mounting. Installation via plenum box is easily installed with bayonet connection in the ceiling via plenum box HTK or as a suspended diffuser with plenum box HTR. -250 mounted with ceiling plate UTD. Mounting mail UTB UTB is an accessory for Lindinvent s plenum box HTK, which is used when mounting in suspended ceilings. UTB is also used with plenum box HTM, see Lindinvents reactive diffuser MTC/MTN. UTB locks the plenum box in the correct position relative to the duct connection. UTB is also used to position the diffuser at the correct height in relation to the suspended ceiling. UTB is available for the most common ceiling tile profiles. The thickness of the suspended ceiling tile must not exceed 40 mm. -400 mounted in plenum box HTK-250/400 for concealed mounting. Load-bearing rail on UTB Profile in the ceiling beam -400 mounted in plenum box HTR-250/400 for suspended mounting. Direct installation in duct can be directly mounted in a duct with the aid of transformer DAB or DAS. The airflow is damped in the diffuser. It is therefore not necessary to use a plenum box for sound damping. -400 mounted in DAB-400 for mounting directly in rectangular duct. -400 mounted in DAS-400 for mounting directly in circular duct. This solution also enables extending the outlet of the plenum box. _A30_PB302_eng_NGP 3(6)

Technical specifications General Dimensions (mm) For dimensions of plenum boxes and diffuser adapters, see the product descriptions for HTK, HTR, DAB and DAS. -250 Occupancy detection Occupancy detector The diffuser has an integral occupancy detector (passive IR detector). Coverage angles See product description for XPIR. Duct temperature measurement Temperature sensor Sensor with thermistor of NTC type. -400 400 35 74 Accuracy Temperature ± 0.5 K Room temperature measurement Temperature sensor Sensor with thermistor of NTC type. Accuracy Temperature ± 0.5 K Material Powder coated steel plate. Net weight -250: 5.6 kg -400: 8.5 kg 550 45 74 Pressure and air flow measurement Pressure and air flow sensor is equipped with a pressure sensor, for duct pressure and air flow measurement. Interval -250: 10-120 Pa -400: 10-120 Pa If a higher pressure range is needed (max 250 Pa) please state this when ordering Accuracy ± 5% or a minimum of ± 3 Pa Paint colour RAL 9003 (Gloss 30) as standard. Other colours may be specially ordered; please state RAL number. Temperature limits Operation: 10 o C to 30 o C; <85% RF Storage: -20 o C to 50 o C; <90% RF Miscellaneous Supplied with mounted and pre-connected 14-conductor cable (connects to connection box CBX) of the length stated when ordering. Standard length of 14-conductor cable: 1 m Maximum length of 14-conductor cable: 10 m Electrical system Supply voltage 24 VAC Capacity 2 VA at rest 4 VA during adjustment (c 50 100 h/year) CE marking Complies with EMC and the Low Voltage Directive Air flow adjustment Interval -250: 3-65 l/s -400: 5-100 l/s Tolerance ± 5% or minimum ± 2 l/s (correct measurement does not require any preceding straight stretch) Performance Maximum change adjusted within c. 2 min. Connections (Via connection box CBX) 2 x 24 VAC measurement + communication loop (CAN) 2 x 0-10 VDC analogue in 1 x control signal to relay on lighting card CBR. 1 x 5 VDC input for push button with lighting control. 2 x 0-10 VDC analogue out 1 x 24 VAC, TRIAC. Intended for valve actuator (maximum 10 x 1W). Connections (Direct on diffuser) 1 x IR unit _A30_PB302_eng_NGP 4(6)

Pressure, flow and sound levels The sound power levels L PA in the diagram correspond to A-weighted sound level in the reverberation zone with 10 m 2 equivalent sound absorption area. This corresponds to 4 db room absorption in a room with normal absorption and a volume of 25 m³. There are examples of corrections with other types of room on the right. Sound generation Sound power level, L W = L WA + K 0 [db] L WA = Total A-weighted sound power level [db (A)] is read from sound diagram -250 and -400 below. K 0 = Correction factor for actual frequency band is read from Table 2. Self-damping according to table 3-6. The measurements have been performed according to ISO 9614-2 and ISO 691:1995. Table 1: Correction for room damping [db] Room volume Type of room Correction 25 m 3 hard room +2 db 25 m 3 normal room 0 db 25 m 3 damped room -2 db 150 m 3 hard room -3 db 150 m 3 normal room -5 db 150 m 3 damped room -7 db Table 2: Correction factors, K 0 [db] 250 10 2-1 -2-1 -2-9 -11 400 15 5-3 -4 0-2 -14-11 Diagram 1: Sound diagram -250 Table 3: Self-damping [db] with plenum box HTK. -250 /HTK 250 17 17 19 22 24 22 22 26 400 19 16 25 29 28 23 24 27 Diagram 2: Sound diagram -400-400 Maximum air flow Table 4: Self-damping [db] with plenum box HTR. /HTR 250 17 17 19 22 24 22 22 26 400 16 12 19 23 22 21 20 23 Table 6: Tolerances [db] Table 5: Self-damping [db] Only diffuser part mounted via transformer DAB or DAS. 250 20 22 15 18 18 15 16 21 400 21 19 15 21 17 15 14 20 ± [db] 250 & 400 3 3 2 2 2 2 2 2 _A30_PB302_eng_NGP 5(6)

Accessories Examples of generally available accessories in Lindinvent s room type solutions. Flow balancing Air flow control DCV-BL, which is included in Lindinvent s series of smart dampers and measuring units, is used for balancing supply air. Lighting control Lighting can be controlled via presence sensor and/or manually via push button by connecting relay box CBR. See control unit SBD for a DALI lighting solution. Radiator control A valve actuator for radiators can be connected for sequence adjustment of heating and cooling. There is a built-in function for cold intrusion protection. Electric radiator control Electric radiators and heaters can be controlled via an electric radiator control box. Reference value adjuster Reference value is normally changed via hand unit DHP or via LINDINSPECT. A wall mounted user panel can also be installed for changing temperature reference value; see digital room panel DRP. External occupancy detector External occupancy detectors can be connected for alternative sensor locations; see XPIR or PD-2400. Wireless communication via IR link DHP is a handheld user panel designed for easy and flexible access to Lindinvent's controllers and control units for climate control. The unit is connected to via IR link. Centre marker A centre marker is available to simplify the positioning of fixing points for plenum boxes. The marker is placed on the ceiling joists where the plenum box is to be mounted. The fixing point can then be marked on the beam. Fan cooling Additional cooling can be adjusted via a fan coil unit control box. Carbon dioxide (CO 2 ) sensors Carbon dioxide sensors can be connected to control air quality. GTQV and GTQD sensors are supplied for wall or duct mounting respectively. Centre marker Additional product documentation Table 7: Additional documentation for can be obtained via links on the product's website under Products at Document Available Not available Comments Installation Instruction Start-up instruction Maintenance instruction External connection diagram Environmental product declaration User information Modbus list Including instruction for installation of the associated HTK and HTR plenum boxes. Gives a list of actual values and settings. Dismantling and checkpoints etc. See also connection box CBX Assessed by Byggvarubedömningen. General information about Lindinvent s system for smart ventilation. Common with VTD. AMA text _A30_PB302_eng_NGP 6(6)