TECHNICAL GUIDE STELLAR 2000 TM S: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Nominal Capacity: 18 thru 60 MBH Nominal Efficiency: 10.00 SEER DESCRIPTION The EFD Series heat pump is the outdoor part of a versatile system designed to economically heat and cool a home or small business. The compact design of these outdoor units make them ideal for ground or roof installation. They are available with sweat connect field piping connections. These units have service valves and contain enough refrigerant charge for the outdoor unit, a matching indoor coil and 15 feet of interconnecting piping. EFD heat pumps may be custom-matched with one of YORK's indoor line of evaporator blower sections, each designed to serve a specific function. Electric heaters are available for both single and three phase applications, in a variety of sizes. For Add-On applications, the indoor coil may be applied in the supply duct of a conventional gas, oil or electric furnace. The heat pump will be the primary source of heat for the building with the furnace operating only when the heating requirement exceeds the capacity of the heat pump. FEATURES QUALITY CONDENSER COILS - The coil is constructed of copper tube and black coated hardened aluminum fins for durability and long lasting efficient operation. The fins on the unit are protected with a decorative grille. DEFROST CONTROL - Time / Temperature defrost control provides field selectable time periods between defrost cycles (30, 60 and 90 minutes). LED lockout indicator, anti-short cycle timer protection are also provided. A built-in soft lockout helps to avoid nuisance trips on high pressure. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. All units have standard crankcase heat for added protection (except 048 and 060, since they are scroll compressors). DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight. LOWER INSTALLED COST - Installation time and costs are reduced by the fully exposed refrigerant connections and the single panel covering of the electrical controls. The small base dimension means smaller mounting pads or less materials required for mounting, thus lowering installation costs. TOP DISCHARGE - The air from the top mounted fan is blown up away from the structure and any landscaping. This allows space saving arrangements of multi-unit installations. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. A compressor blanket accessory is available for those applications requiring further sound reduction. LOW MAINTENANCE - Long life permanently lubricated motor- bearings need no annual servicing. RE-USABLE SERVICE VALVES - Provided on all sweat fittings on both the liquid and vapor connections for ease of evacuating, charging, and servicing. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING COIL * ELECTRIC HEAT KW RATED NET MBH W KW SEER SEER / CFM TOTAL SENS. TXV EER 1 AND 3 PHASE EFD / NAH / GFD E4FD018 N1AHB08 2,5,7.5,10 17 G2FD024S17 650 18.4 13.8 1.7 11.00 --- 9.10 N1AHB08 2,5,7.5,10 17 G2FD024S17 800 23.0 17.3 2.2 10.45 --- 9.15 N1AHB08 5,7.5,10,15,18 17 G2FD030S17 800 23.4 17.6 2.2 10.50 --- 9.40 N1AHB08 5,7.5,10,15,18 14 G2FD035S14 850 23.4 17.6 2.2 10.50 --- 9.20 N1AHB12 5,7.5,10,15,18 17 G2FD030S17 1000 29.0 21.8 2.9 10.50 --- 9.40 N1AHB12 5,7.5,10,15,18 17 G2FD035S14 1025 29.0 21.8 2.9 10.50 --- 9.40 N1AHB12 5,7.5,10,15,18 17 G2FD036S17 1025 29.4 22.1 2.9 11.00 --- 9.40 N1AHB12 5,7.5,10,15,20 21 G2FD036S21 1025 29.4 22.1 2.9 11.00 --- 9.50 N1AHB12 5,7.5,10,15,18 17 G2FD036S17 1220 35.0 26.3 3.5 10.00 --- 9.20 N1AHB12 5,7.5,10,15,20 21 G2FD036S21 1220 35.0 26.3 3.5 10.00 --- 9.20 N1AHB12 5,7.5,10,15,18 17 G2FD042S17 1220 35.4 26.6 3.5 10.20 --- 9.15 N1AHB12 5,7.5,10,15,18 17 G2FD046S17 1220 35.4 26.6 3.5 10.20 --- 9.15 N1AHC16 5,7.5,10,15,20 21 G2FD042S21 1400 40.5 30.0 4.43 10.00 --- 9.15 N1AHC16 5,7.5,10,15,20 21 G2FD048S21 1425 41.5 30.7 4.49 10.10 --- 9.25 N1AHC16 5,7.5,10,15,20,25,30 21 G2FD048S21 1600 45.5 33.7 4.84 10.50 --- 9.40 E4FD048 N1AHD20 5,7.5,10,15,20,25,30 24 G2FD048S24 1600 45.5 33.7 4.84 10.50 --- 9.40 N1AHD20 5,7.5,10,15,20,25,30 24 G2FD060S24 1625 47.0 34.8 4.87 10.80 --- 9.65 E4FD060 N1AHD20 5,7.5,10,15,20,25,30 24 G2FD060S24 1800 59.0 44.0 6.00 11.00 --- 9.90 1 AND 3 PHASE EFD / NVS / GFD E4FD018 N1VSB12 5,7.5,10,15,18 17 G2FD024S17 650 19.0 14.3 1.7 12.00 --- 10.30 N1VSB12 5,7.5,10,15,18 17 G2FD024S17 800 23.6 17.7 2.0 11.70 --- 10.20 N1VSB12 5,7.5,10,15,18 17 G2FD030S17 850 24.0 18.0 2.1 11.80 --- 10.65 N1VSB12 5,7.5,10,15,18 17 G2FD036S17 1025 30.0 22.5 2.9 11.60 --- 9.30 N1VSB12 5,7.5,10,15,18 17 G2FD030S17 1025 29.0 21.8 2.9 11.30 --- 9.40 N1VSB12 5,7.5,10,15,18 17 G2FD036S17 1200 35.6 26.7 3.1 10.80 --- 9.50 N1VSB16 5,7.5,10,15,20 17 G2FD036S21 1200 35.6 26.7 3.1 11.00 --- 9.70 N1VSB12 5,7.5,10,15,18 17 G2FD046S17 1200 36.2 27.2 3.2 11.00 --- 9.80 N1VSC16 5,7.5,10,15,20 21 G2FD042S21 1225 36.2 27.2 3.2 11.20 --- 10.00 N1VSC16 5,7.5,10,15,20 21 G2FD048S21 1425 42.0 31.1 4.20 11.00 --- 10.00 E4FD048 N1VSC16 5,7.5,10,15,20 21 G2FD048S21 1600 46.0 34.0 4.60 11.00 --- 10.00 N1VSD20 7.5,10,15,20,25,30 24 G2FD060S24 1625 48.0 35.5 4.53 12.00 --- 10.60 E4FD060 N1VSD20 7.5,10,15,20,25,30 24 G2FD060S24 1800 60.0 45.0 5.50 11.50 --- 11.20 *. To meet Florida insulation code requirements, substitute F2FP for F2RP models. All ratings remain the same.. ( ) indicates 3 Ø heater match-up for single piece air handler. See price pages for additional air handler heater selections.. TXV = Thermal Expansion Valve. 1 AND 3 PHASE EFD / FRP AIR HANDLER * ELECTRIC HEAT KW W COIL COOLING Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watthours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. -- = Not Applicable. RATED CFM NET MBH TOTAL SENS. KW SEER SEER / TXV E4FD018 F2RP/FP018 2,5,8 18 --- 650 17.8 13.4 1.7 10.70 --- 9.00 F2RP/FP024 5,8,10,(10),(15) 18 --- 650 18.0 13.5 1.8 10.50 --- 9.00 F2RP/FP024 5,8,10,(10),(15) 18 --- 800 22.6 17.0 2.2 10.40 --- 9.40 F2RP/FP030 5,8,10,15,(10),(15) 18 --- 800 23.2 17.4 2.3 10.70 --- 9.50 F2RP/FP030 5,8,10,15,(10),(15) 18 --- 1035 29.0 21.8 2.8 10.50 --- 9.3 F2RP/FP036 5,8,10,15,(10),(15) 18 --- 1035 29.4 22.1 2.9 11.00 --- 9.4 F2RP/FP036 5,8,10,15,(10),(15) 18 --- 1200 34.2 25.7 3.5 10.00 --- 8.90 F2RP/FP042 5,8,10,15,(10),(15) 21 --- 1200 35.0 26.3 3.4 10.20 --- 9.20 F2RP/FP042 5,8,10,15,(10),(15) 21 -- 1400 40.5 30.0 4.31 10.00 -- 9.40 F2FP048 10,15, 20, 25, (10),(15) 24 -- 1400 41.5 30.7 4.30 10.30 -- 9.65 E4FD048 F2FP048 10,15, 20, 25, (10),(15) 24 -- 1600 46.0 34.0 4.89 10.00 -- 9.40 E4FD060 F2FP060 10,15, 20, 25, (10),(15) 24 -- 1800 57.5 43.1 5.78 10.00 -- 9.60 F2FV060 10,15, 20, 25, (10),(15) 24 -- 1800 59.0 44.2 5.60 11.00 -- 10.50 *. To meet Florida insulation code requirements, substitute F2FP for F2RP models. All ratings remain the same.. ( ) indicates 3 Ø heater match-up for single piece air handler. See price pages for additional air handler heater selections.. TXV = Thermal Expansion Valve. EER 2 Unitary Products Group
COOLING CAPACITY - With Standard Furnaces E4FD018 E4FD048 FURNACE * COIL 2 NOMINAL W AIRFLOW 800 1000 800 1000 1200 1000 1200 1400 1200 1400 1600 1400 1600 2000 1600 2000 E4FD060 2000 COOLING RATED NET MBH SEER/ KW SEER CFM TOTAL SENS. TXV 3 EER 14,17 G1UA024S14,17 650 18.2 13.7 1.8 10.70 --- 9.00 14,17 G2FD024S14, 17 650 18.4 13.8 1.8 11.00 --- 9.10 14 G1UA030S14 650 18.4 13.8 1.8 11.00 --- 9.10 ** G1HD024 650 18.0 13.5 1.8 11.00 --- 10.60 14,17 G2FD024S14,17 800 23.0 17.9 2.2 10.45 --- 10.99 ** G1HD024 800 23.0 17.3 2.2 10.00 --- 9.45 14 G1UA030S14 850 23.0 17.3 2.2 10.20 --- 9.15 17,21 G1UA036S17,21 850 23.4 17.6 2.2 10.50 --- 9.65 17 G2FD030S17 850 23.4 17.6 2.2 10.50 --- 9.65 14 G2FD035S14 850 23.4 17.6 2.2 10.50 --- 9.65 17 G2FD030S17 1000 29.00 21.75 2.8 10.50 --- 9.30 14 G2FD035S14 1000 29.00 21.75 2.9 10.50 --- 9.30 17,21 G1UA036S17, 21 1025 29.00 21.75 2.8 10.50 --- 9.30 21 G2FD036S21 1025 29.40 22.05 2.9 11.00 --- 9.40 17 G2FD036S17 1025 29.40 22.05 2.9 11.00 --- 9.40 ** G1HD036 1025 29.00 21.75 2.8 10.75 --- 9.55 17 G1UA048S17 1225 35.6 26.7 3.5 10.30 --- 9.20 21,24 G1UA048S21, 24 1250 35.6 26.7 3.5 10.30 --- 9.20 ** G1HD036 1225 35.0 26.3 3.5 10.00 --- 9.10 17 G2FD036S17 1225 35.0 26.3 3.4 10.00 --- 8.90 21 G2FD036S21 1225 35.0 26.3 3.5 10.00 --- 8.90 21 G2FD042S21 1225 35.4 26.6 3.5 10.20 --- 9.20 17 G2FD046S17 1225 35.4 26.6 3.5 10.20 --- 9.20 ** G1HD036 1225 35.0 26.3 2.8 10.00 --- 9.10 21 G2FD042S21 1400 40.5 30.0 4.43 10.00 -- 9.15 21,24 G1UA048S21,24 1425 41.5 30.7 4.28 10.50 -- 9.70 -- G1HD048S 1400 41.0 30.3 4.43 10.10 -- 9.25 17 G2FD046S17 1400 41.0 30.3 4.46 10.00 -- 9.20 -- G1HD060S 1425 42.5 31.5 4.50 10.30 -- 9.45 21,24 G2FD048S21,24 1425 41.5 30.7 4.49 10.10 -- 9.25 -- G1HD048S 1600 45.0 33.3 4.79 10.50 -- 9.40 21,24 G2FD048S21,24 1600 45.5 33.7 4.84 10.50 -- 9.40 21,24 G1UA048S21,24 1600 46.0 34.0 4.87 10.70 -- 9.45 21,24 G1UA060S21,24 1620 47.0 34.8 4.90 10.80 -- 9.60 24 G2FD060S24 1620 47.0 34.8 4.87 10.80 -- 9.65 -- G1HD060 1620 46.5 34.4 4.84 10.70 -- 9.60 21,24 G1UA060S21, 24 1800 58.5 43.8 5.91 10.50 -- 9.90 -- G1HD060 1800 57.0 42.7 5.81 10.50 -- 9.20 24 G2FD060S24 1800 59.0 44.0 6.00 11.00 -- 9.90 *. Refer to Quick Selection Chart for specific furnace match-up. See Notes on Page 2 1 Rated CFM same as for cooling. 2 Heating performance and efficiency is the same for TXV application. Heating MBH based on 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. 3 Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. COP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. VS = Variable Speed. - = Not Applicable. Unitary Products Group 3
HEATING PERFORMANCE - With Air Handler and Multi-Position Coils COIL * 1 AND 3 PHASE EFD / AIR HANDLERS & COILS E4FD018 E4FD048 E4FD060 ARI HEATING OUTDOOR TEMP 47 F 17 F HSPF -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MBH COP STD VS MBH KW MBH KW MBH KW MBH MBH MBH KW MBH KW MBH KW F2RP/FP018 17.6 3.00 10 2.00 7.10 -- 4.4 1.09 7.2 1.1 10 1.25 12.4 1.3 15 1.42 17.6 1.53 21 1.75 F2RP/FP024 17.8 3.10 10 2.00 7.10 -- 4.8 1.05 7.4 1.09 10 1.25 12.6 1.31 15.6 1.4 17.8 1.5 21.2 1.73 G2FD024S14, 17 18 3.06 9.9 2.00 7.10 7.2 5 1.02 7.6 1.1 9.9 1.23 12.8 1.32 15.6 1.38 18 1.52 22 1.72 F2RP/FP024 22.4 3.10 12.5 2.00 7.35 -- 6.1 1.5 9.3 1.6 12.5 1.75 15.6 1.92 18.8 2.02 22.4 2.13 27.1 2.23 F2RP/FP030 22.8 3.20 12.8 2.10 7.40 -- 6.3 1.55 9.4 1.68 12.8 1.68 16 1.9 19 2 22.8 2.14 27.7 2.3 G2FD024S14, 17 22.4 3.10 12.2 2.00 7.60 7.7 6.3 1.5 9.3 1.5 12.2 1.7 16 1.89 19.2 2.05 22.4 2.12 27 2.4 G2FD030S17 22.6 3.10 12.4 2.00 7.10 7.2 6.5 1.4 9.6 1.46 12.4 1.7 16 1.92 19 2.07 22.6 2.14 28 2.33 G2FD035S14 22.4 3.10 12.4 2.00 7.10 -- 6.6 1.5 9.8 1.6 12.4 1.7 16.2 1.9 19.2 2.06 22.4 2.15 28 2.3 F2RP/FP030 29 3.20 17 2.30 7.60 -- 10.4 2 13.8 2.1 17 2.23 21.2 2.35 24.8 2.48 29 2.58 34.2 2.68 F2RP/FP036 28.4 3.20 17.4 2.30 7.50 -- 10.2 1.95 13.6 2.11 17.4 2.22 22 2.37 24.8 2.5 28.4 2.57 34.6 2.69 G2FD030S(H)17 29.2 3.20 17 2.30 7.60 7.8 10.4 2 13.8 2.18 17 2.21 21.8 2.4 25 2.6 29.2 2.58 34.2 3.7 G2FD035S(H)14 29.2 3.20 17 2.30 7.60 -- 10.7 1.98 14 2.15 17 2.23 24 2.42 25.8 2.48 29.2 2.58 34.4 2.65 G2FD036S(H)17, 21 29.2 3.20 17.4 2.30 7.60 7.7 10.8 2 14.2 2.11 17.4 2.22 24 2.4 25.6 2.48 29.2 2.54 34.6 2.67 F2RP/FP036 35.2 3.20 21 2.30 7.50 -- 10.8 2.5 15.4 2.63 21 2.8 24.8 2.95 28.4 3 35.2 3.26 43 3.47 F2RP/FP042 35.2 3.20 20 2.10 7.50 -- 10.8 2.5 15.6 2.6 20 2.6 25 2.94 28.6 3 35.2 3.2 43.2 3.4 G2FD042S(H)21 35 3.20 20 2.10 7.40 7.6 10.8 2.2 15.4 2.62 20 2.6 25 2.76 28.8 2.95 35 3.2 43.2 3.45 G2FD046S(H)17 35 3.20 20 2.10 7.40 7.6 10.8 2.2 15.8 2.6 20 2.7 25.2 2.76 28.8 2.95 35 3.2 44 3.46 G2FD036S(H)17, 21 35.2 3.20 21 2.30 7.50 7.6 10.6 2.5 15.4 2.64 21 2.6 25 2.8 28.6 2.98 35.2 3.2 43 3.4 F2RP/FP042 39.5 3.20 22.6 2.20 7.4-11.7 2.50 17.2 2.76 22.6 3.00 28.0 3.26 33.9 3.50 39.5 3.62 48.7 4.01 F2FP048 40.5 3.30 23.8 2.28 7.5-13.1 2.60 18.5 2.84 23.8 3.10 29.1 3.28 35.0 3.50 40.5 3.60 49.8 4.00 G2FD042S(H)21 39.0 3.24 23.2 2.2 7.4-13.4 2.81 18.3 2.95 23.2 3.09 28.1 3.23 33.6 3.39 39.0 3.53 46.7 3.76 G2FD046S(H)17 39.0 3.28 23.2 2.20 7.4-13.0 2.80 18.1 2.92 23.2 3.10 28.3 3.26 33.8 3.40 39.0 3.46 47.8 3.80 G2FD048S(H)21,24 39.5 3.40 23.4 2.28 7.4 7.5 13.1 2.50 18.2 2.67 23.4 2.90 28.6 3.04 34.2 3.20 39.5 3.31 48.6 3.60 F2FP048 47.0 3.30 28.0 2.3 7.8-15.7 3.16 21.8 3.36 28.0 3.57 34.2 3.77 40.9 4.00 47.0 4.17 56.1 4.50 G2FD048S(H)21,24 47.0 3.50 28.0 2.32 8.0 8.0 16.1 3.30 22.1 3.40 28.0 3.50 33.9 3.67 40.7 3.80 47.0 3.96 54.8 4.20 G2FD060S(H)24 47.0 3.46 28.0 2.32 8.0 8.0 16.1 3.3 22.0 3.41 28.0 3.50 34.0 3.67 40.7 3.80 47.0 3.94 54.9 4.10 F2FP060 61 3.30 39 2.40 8.20 -- 21.4 4.5 30.1 4.6 39 4.75 43 4.9 52.1 5.1 61 5.3 63 3.47 F2FV060 60 3.30 39 2.40 8.20 -- 21.1 4.3 31 4.7 39 4.8 43.2 4.91 52.3 5.09 60 5.25 63.2 3.4 G2FD060S(H)24 60 3.40 39 2.40 8.50 8.5 21.1 4.4 26.2 4.6 38 4.7 43 4.85 51.8 5.1 60 5.3 63 3.45 *. Rated CFM same as for cooling.. Heating performance and efficiency is the same for TXV application. Heating MBH based on 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. 4 Unitary Products Group
HEATING PERFORMANCE - With Furnace Coils COIL * ARI HEATING OUTDOOR TEMP 47 F 17 F HSPF -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MB H 1 AND 3 PHASE EFD / UPFLOW FURNACE & COILS E4FD018 E4FD048 E4FD060 COP STD VS MBH KW MBH KW MBH KW MBH MB H MBH KW MBH KW MBH KW G1HD024 18.2 3.08 9.9 2.00 7.1-4.3 1.25 7.1 1.35 9.9 1.45 12.7 1.55 15.5 1.65 18.2 1.73 21.5 1.79 G1UA024S17 18.0 3.00 9.9 2.00 7.1-4.4 1.23 7.2 1.34 9.9 1.45 12.6 1.56 15.5 1.67 18.0 1.76 21.6 1.88 G1UA030S14 18.2 3.06 9.9 2.00 7.1-4.3 1.25 7.1 1.35 9.9 1.45 12.7 1.55 15.5 1.65 18.2 1.74 21.5 1.81 G1HD024 22.0 3.00 12.2 2.00 7.5-5.8 1.55 9.0 1.67 12.2 1.8 15.4 1.91 18.6 2.03 22.0 2.15 26.7 2.30 G1UA030S14 22.0 2.94 12.2 2.00 7.6-5.8 1.51 9.0 1.65 12.2 1.79 15.4 1.93 18.6 2.06 22.0 2.19 26.7 2.35 G1UA036S17,21 22.4 3.00 12.4 2.00 7.1-5.9 1.57 9.1 1.69 12.4 1.82 15.7 1.94 18.9 2.07 22.4 2.19 27.2 2.33 G1HD036 29.6 3.36 18.3 2.36 7.8-10.9 2.03 14.6 2.5 18.3 2.27 22.0 2.39 26.0 2.51 29.6 2.58 35.4 2.75 G1UA036S17,21 29.2 3.20 17.0 2.30 8.0-10.2 1.99 13.9 2.11 17.5 2.23 21.1 2.35 23.7 2.41 28.4 2.55 33.1 2.72 G1HD036 36.4 3.28 20.4 2.38 7.4-9.7 2.01 15.1 2.26 20.4 2.51 25.7 2.77 29.7 2.95 36.4 3.25 44.6 3.56 G1UA048S21 35.0 3.2 20.0 2.10 7.4-8.9 1.93 14.7 2.21 20.4 2.49 26.1 2.77 30.0 2.97 37.0 3.29 44.8 3.62 G1HD048 39.5 3.32 23.4 2.28 7.4-13.0 2.60 18.2 2.81 23.4 3.01 28.6 3.21 34.2 3.39 39.5 3.49 48.3 3.84 G1HD060 39.5 3.36 23.4 2.28 7.4-13.1 2.63 18.3 2.82 23.4 3.01 28.5 3.20 34.2 3.36 39.5 3.45 48.5 3.77 G1UA048S21 39.5 3.40 23.4 2.34 7.4-12.8 2.68 18.1 2.84 23.4 3.01 28.7 3.20 32.8 3.27 40.0 3.49 48.2 3.74 G1HD048 47.0 3.48 28.0 2.32 8.0-13.3 2.73 18.4 2.87 23.4 3.01 28.4 3.13 34.2 3.31 39.5 3.45 46.3 3.65 G1HD060 47.0 3.46 28.0 2.32 8.0-16.1 3.23 22.0 3.39 28.0 3.54 34.0 3.69 40.7 3.85 47.0 3.98 54.9 4.18 G1UA048S17,21,24 47.0 3.42 28.0 2.30 8.0-15.1 3.24 21.5 3.40 28.0 3.57 34.5 3.73 39.1 3.83 47.0 4.03 56.0 4.27 G1UA060S24 47.0 3.46 28.0 2.32 8.0-15.1 3.21 21.5 3.37 28.0 3.54 34.5 3.70 39.1 3.79 47.0 3.98 56.0 4.21 G1HD060 60.0 3.10 38.0 2.40 8.2-18.1 4 26.2 4.5 38 4.95 43.1 4.9 52 5.1 60 3.25 72.1 5.9 G1UA060S21,24 61.5 3.40 39.0 2.40 8.2-18.2 4 26.5 4.4 39 4.98 43.2 4.85 52.1 5.2 61.5 3.26 73.1 5.95 *. Rated CFM same as for cooling.. Heating performance and efficiency is the same for TXV application. Heating MBH based on 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.. Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. SOUND RATINGS E*FD SOUND RATING DECIBELS 018 73 024 74 030 74 036 76 * 042 78* 048 78* 060 78* 076 78* *. Rated in accordance with ARI Standard 270. CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI Unitary Products Group 5
TYPICAL INSTALLATION TO INDOOR BLOWER THERMOSTAT TO POWER SUPPLY NEC CLASS 1 WIRING WEATHERPROOF DISCONNECT SWITCH 48 OVERHEAD CLEARANCE 12 REAR AND SIDES NEC CLASS 2 WIRING TO COIL 24 SERVICE ACCESS CLEARANCE NOTE: All outdoor wiring must be weatherproof Seal opening(s) with permagum or equivalent ACCESSORIES Refer to Price Manual for specific model numbers. Start Assist Kit (2SA06701006) - Provides increased starting torque for areas with low voltage conditions. Hard Start Kits - Provides required starting torque for use with Thermal Expansion Valve Kit. Low Temperature Cutout (2LT06700224) - Prevents heat pump operation below -10 F ambient temperature. Compressor Blanket - Designed to further reduce the normal operating sound. Add-on Control (2AC02700701) - Provides interface for use of gas and oil furnaces with the heat pump system. Thermal Expansion Valve Kit - 1TV0700 Series TXV kit used to improve system performance. Blower Off Delay (2FD06700224) - Available to increase efficiency. Installs on indoor section to maintain blower operation for approximately 1 minute on shutdown. Standard on most indoor models. Outdoor Thermostat (2TD06700124) - Provides additional staging of supplemental electric heat. Room Thermostats - A wide selection of matching thermostats is available to provide features required for any installation. 2TH11702224 2H/1C with subbase, manual change-over non-electronic thermostat. 2TH11702424 2H/1C with subbase, automatic changer over nonelectronic thermostat. 2ET11704324 2H/1C non-programmable electronic thermostat, with manual changer over. 2ET11700224 2H/1C programmable electronic manual changeover thermostat with subbase. 6 Unitary Products Group
TYPICAL FIELD WIRING - 1 Ø (AIR HANDLER / ELECTRICAL HEAT) ALLWIRINGTOBEINACCORDANCEWITHNATIONALELECTRICCODEAND/ORLOCALCODES THERMOSTAT R 7WIRES INDOOR 3,4 LOWVOLTAGETERMINALBLOCK INAIRHANDLERWITHELECTRICHEAT R RED R DEFROST CONTROL OUTDOOR BorC Y O C Y O BLK C YEL Y ORG O CONTACTOR GRD. SCREW W LorX G W2 G W1 BRN W PRP X WHT W1 T2 L2 M T1 L1 BK 2 Terminalnot usedonallthermostats. DEHUMIDIFICATIONCONTROL CONNECTION ("Humidistat"Jumpermust beremoved) POWERWIRING 24VCONTROLWIRING (NECCLASS2) CIRCUIT GRD. LUG POWERWIRING 208/230-1-60 BREAKER*** 3 Checkthelowvoltageterminalblockontheindoorunit fortheactualarrangement of theterminals. 4 Connect powerwiringtoterminalblock3tbonunitswithout electricheat orcircuit breaker. TYPICAL FIELD WIRING - 3 Ø (AIR HANDLER / ELECTRICAL HEAT) ALL WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND/OR LOCAL CODES INDOOR OUTDOOR CONTACTOR GRD. LUG POWER SUPPLY 208/230-3-60 460-3-60 T3 L3 T2 M L2 T1 L1 GRD. SCREW POWER WIRING POWER WIRING 208/230-3-60 460-3-60 Unitary Products Group 7
MATCHING INDOOR COMPONENTS Add-On Coils - For Furnace Application Air Handlers - For Non-Furnace Application G-UA COIL G-HD COIL N-AH BLOWER/ G+FD COIL UPFLOW DOWNFLOW HORIZONTAL G+FD COIL F2RC / F2FC OR F2RP / F2FP FAN COIL S G-NA COIL UPFLOW HORIZONTAL Subject to change without notice. Printed in U.S.A. 036-21030-002 Rev A Copyright by Unitary Products Group 2000. All rights reserved. Supersedes: 515.26-TG5Y (0200 036-21030-00 A (0200) Unitary 5005 York Norman Products Drive OK Group North 73069