Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

Similar documents
Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

Marley Ultra Quiet Fan

AXPR Wall Mounted Axial Panel Fans

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

INLET DAMPER WALL FAN UNIT

568X, 587X, 588X Series

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

Audi-Larm Audible Alarm

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

Fan Motor. user manual INSTALLATION - OPERATION - MAINTENANCE

Unilite cooling tower

WAILEA OWNER S MANUAL

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

HORIZONTAL AGITATOR ASSEMBLY

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Altra Series Dampener

User Manual. Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual

Downtime Instructions

MODEL PR16 POWER ROTARY

Removal. CAUTION: Do not let tensioner arm snap back to the freearm position, sever damage may occur to the tensioner.

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Installation, Operation and Maintenance Manual

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Power Washer Maintenance

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Types TMUB, TMUAH and. J Jockey Pumps

cooling tower downtime instructions

Maintenance 5-1. Good maintenance is essential for cleaning results, and long economical life of the washer.

STAINLESS STEEL UNITS

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Group 7 COOLING SYSTEM CONTENTS

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

MatrixMultiflow. Owners Manual. Manual

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Hickory Rotisseries. Machine Type N / 5. 5 E 200ºF - 550ºF. Final Inspection:

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

ACN SMOKE INSTALLATION AND MAINTENANCE

Technical Bulletin. 1405F/DF Switching Valve Maintenance NEW DESIGN Bulletin # TS0062 Rev 05/2016

MIST MAX MODEL MM800. Important: Installation and Operation Manual

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

Panel Fan Series Operators Manual (Galvanized and Polymer)

Installation, Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

IPT Series 2P5X, 2S5X, 2S5XC & 3S5X Pumps Refer to pump manual for General Operating and Safety Instructions.

Model 4146 Chopper. This manual replaces and should be used instead of form (9-84) FORM (September 2012)

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

Aquatower User Manual

INSTALLATION INSTRUCTIONS

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

SuperKlean Washdown Products

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Spencer Multi-Stage Centrifugal Blowers. Handling, Installing and Operating Instructions. Important. Serial No: Model No: Four-Bearing Outboard

Air Driven Sewer Pipe Tapping Machine Instruction and Maintenance Manual

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

ELECTRIC UNIT HEATER UH SERIES

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

57" Fiberglass Exhaust Fan with Cone

Vertical Inline Models

Installation Instructions Part No , Part No Part No

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

BELT DRIVEN STATIONARY AGITATOR

Operating Instructions & Parts Manual Models 99533, 99532

Owner s Guide and Installation Manual

Instructions for Colonel Electric Label Gluer

FD 90 / FD 95 Rotary Perforators

24 & 30 Quiet Design Oscillating Wall Mount Fan

Panel Fan Series Operators Manual (Galvanized and Polymer)

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Installation and Operation Manual For Hunter Ceiling Fans

ATTIAS MANUFACTURERS OF ATTIAS DOUGH MIXERS 265 BOWERY NEW YORK, N.Y TEL: (212) FAX: (212) COMMERCIAL DOUGH MIXERS

MERCHANT POPCORN MACHINE SERVICE MANUAL

Transcription:

DuraCore TM Fan Owners Manual SM-HP8-64-360A SM-HP8-10 Meter Manual 9-1473D 1

4 5 7 8 9 6 MONEL HARDWARE 7 8 9 STAINLESS HARDWARE 00 FAN BLADE FAN HUB 3 Fan Components Marley Order No. Trial Pitch Angle Final Pitch Angle Speed-rpm Contract hp

Fan Hub Assembly and Installation The following instructions detail the process for installing a Marley DuraCore fan on a Marley Geareducer with tapered shaft and bolted fan hub retention hardware. Installation on other gear reduction units may be different. The fan hub is normally factory assembled but if the fan hub requires assembly, start with Item 1 in the following section otherwise start with Item. 1 The hub plates and center hub are match-marked for assembly orientation. Locate and line up the keyway on the center hub 1 with the match-marks on the hub plates. Attach hub plates to center hub using 5/8" x 1 1/" bolts 4, and 5/8" flat washers 5. Lubricate this hardware before torquing the 5/8" cap screws to 150 ft lb ƒ (04 N m). Thread lube is shipped with fan assembly. See Figure 1. Match marks are in line with the keyway. I on the outside top surface and II on the outside bottom surface 4 5 1 Figure 1 5 4 Remove the retention hardware from the top of the Geareducer fan shaft. Thoroughly clean the Geareducer fan shaft, fan shaft key and the fan center hub bore to remove any debris and/or protective coating. After cleaning, apply a coat of anti-seize compound to the top 7" of the Geareducer fan shaft. Note If the hub is to be installed on a Series 36 or 38 Geareducer refer to additional instructions on page 4. 3

Fan Hub Installation 3 Prior to hub installation, position the key in the fan shaft keyseat. Be sure the key is fully seated in the keyway depth. The key is a tight fit across the width of the fan shaft keyseat and must never be altered to fit loose. 4 Hoist the fan hub above the shaft for installation. Slowly lower the hub onto the fan shaft with the keyway properly aligned. Make certain that the key does not slide down during installation. It may be helpful to stake the key in the keyway with a center punch at the bottom of the key. 5 The fan shaft key should be approximately centered in the fan center hub when the hub is fully engaged on the shaft. Unless the key is longer than the fan center hub, it should not extend out of the center hub. 6 Visually inspect the fan center hub to be certain that it is fully seated against the shaft at the top and bottom of the hub. 7 Install the fan hub retention hardware and torque bolts to 70 ft lb ƒ. (95 N m). 36 and 38 Geareducer Series 36 and 38 Geareducers utilize a unique tapered key on the fan shaft of the Geareducer. The following instructions detail the proper installation procedure for these Geareducers. 1 Prior to fan hub installation the key must be positioned in the fan shaft keyseat as shown in Figure 3. The key is a tight fit across the width of the fan shaft keyseat and must never be altered to fit loose. After the fan hub is installed, the bottom end of the key must extend through the bottom of the fan center hub, and the top end of the key must be more than 5/8" above the top of the fan shaft. Do not force the key down once these criteria are met. The key may extend above the top of the fan center hub. 3 Figure illustrates the proper installation of the retention plate and hardware. The retention plate is designed to allow clearance for the fan shaft key and when properly installed will not extend over or interfere with the key in any way. Torque the retention bolts to 70 ft lb ƒ (95 N m), then turn the corners of the locking straps up to capture the flats on the bolt heads to prevent bolts from loosening. 4

Fan Hub Installation RETENTION BOLTS RETENTION PLATE KEY FAN HUB Figure 36 and 38 Geareducer LOCKING STRAPS GEAREDUCER FAN SHAFT 1" MIN 11/" 11/" 13/8" TAPERED SIDE OF KEY Figure 3 36 and 38 Geareducer 5

Fan Assembly Marley DuraCore fan blades and blade clamps are match-weighed at the factory. The fan blades and blade clamps can be installed in any sequence without affecting fan balance. Note The blades are inscribed on the end of the shank with a letter code (i.e. A or B etc. ). When assembling or replacing blades be sure to install only blades of the same letter code within a hub assembly. 1 Locate blade clamps 3 and position blade clamps around the shank of the fan blades with chamfered end of blade clamp against the blade safety shoulder. See Figure 4. Large nylon cable ties can be used to hold the clamps to the blade for easier assembly into the hub. There are spacers assembled with the blade clamps for shipping purposes only. Remove and discard these spacers prior to assembly of fan. Slide the blade, with the clamps around the shank, between the plates, lining up the 4 bolt holes in the clamp and both plates. Install four 3/4" diameter bolts 7, eight 3/4" flat washers 8 (four 3/4" lock washers 6 if hardware is monel) and four 3/4" nuts 9 with the nut on the top side as shown. Lubricate hardware before tightening nuts finger tight. See Figure 4. 9 6 MONEL HARDWARE ONLY 8 3 Figure 4 FAN BLADE 8 7 6

Fan Assembly 4 Do not tighten blade clamp hardware until all the blades are installed. Repeat steps 3 and 4 until all blades are installed in the hub. 5 Position the fan blades so that arrow showing direction of rotation is on the air discharge (top) side of the fan. 6 Pull each blade as far from the center of the fan as the blade clamp bolts and safety shoulder will allow. 7 Select a position on the fan circumference and rotate each blade to this location when setting or checking blade pitch. The blade pitch is set within " of the blade tip. Place a bevel protractor on top of a parallel sided straight edge that extends the full width of the blade to measure the fan blade pitch. See Figure 5. BLADE TIP STRAIGHT EDGE BEVEL PROTRACTOR PITCH ANGLE Section Figure 5 8 Set the bevel protractor at the specified trial pitch angle supplied by The Marley Cooling Tower Company for your fan (see page ). The trial blade pitch angle is the calculated setting for rated design conditions. Water rate, heat load and/or air density other than rated design conditions can vary the brake horsepower of the fan. 9 Support the blade at the tip to maintain a proper plane of rotation while holding the pitch angle. Progressively tighten all 3/4" nuts 9 at the blade clamp to 10 ft lb ƒ (163 N m) torque. Recheck the pitch angle. Blades should be within ±1/4 of the desired pitch. Next, check the tip track variation. The vertical tip track variation from a reference plane of rotation is ±1" (5 mm) for 64" through 360" fans and ±1 1/4" (3 mm) for 10 meter fans. If the tip track variation is off, support the blade tip higher when tightening the blade clamp bolts. 10 Repeat step 9 for all blades. 7

Fan Operation 1 Bump the fan motor and check for correct rotation. Rotation should be clockwise when viewed from the air discharge side. Start and operate the fan until the motor and Geareducer have reached operating temperature (approximately 30 minutes). Measure the operating voltage and amperage for use in calculating motor horsepower by the following equation: HP A = VOLTS A x AMPS A VOLTS N x AMPS N x HP N HP A = Actual Horsepower VOLTS A = Actual Volts AMPS A = Actual Amperage VOLTS N = Nameplate Volts AMPS N = Nameplate Amperage HP N = Nameplate Horsepower 3 The calculated horsepower should be close to the contract horsepower specified by The Marley Cooling Tower Company. Measurements used in these calculations must be made with the specified rate of hot water flowing through the towers. Note Measurements taken on motors operating with Variable Frequency Drive controls may read up to 15% high from errors in measuring the approximated sine wave. Instruments capable of measuring a squared off wave form accurately should be used for measuring power in this situation. 4 Adjust fan pitch as required to obtain the desired motor load. If blades are repitched, nuts must be retightened to 10 ft lb ƒ (163 N m) torque. Record the final pitch angle on page. Caution When checking and/or changing blade pitch or cycling fan in normal operation, do not exceed 30 sec/hour total motor starting time as motor may be overheated. 8

Routine Maintenance Preventive maintenance will prolong useful life and assure continued trouble-free operation. 1 Check, and if necessary, retighten blade clamping hardware to the prescribed torque at six-month intervals. Inspect the fan for damage from striking debris or corrosive attack at the same time the torque is checked. Remove any accumulation of scale or dirt if there are indications balance is affected. 3 If it is necessary to disassemble the fan for any reason, blade clamp bolt threads and nut bearing surfaces must be coated with anti-seize thread lubricant before reassembly and tightened to the prescribed torque. Fan Service When writing the Marley sales office or representative for repair or replacement parts, please refer to the tower serial number. Replacement blades can be installed without field rebalancing. The fan diameter and blade letter code (see page 6) are required when ordering replacement blades. If rebalancing is required, trial and error attachment of balance weights to the fan hub may produce a satisfactory dynamic balance. If this is not satisfactory, return the complete fan hub assembly to The Marley Cooling Tower Company for factory rebalance. Obtain a Customer Return Material tag from your Marley sales office or the representative in your area. 9

Parts List 300 Series Stainless Steel Hardware Item Description 1... Center Hub... Hub Plate 3... Blade Clamp 4... Cap Screw 5/8" x 1 1/" 300s SS 5... Flat Washer 5/8" 300s SS 7... Bolt 3/4" x 8 1/" 300s SS 8... Flat Washer 3/4" 300s SS 9... Nut 3/4" self-locking 300s SS 00... Fan blade 316 Stainless Steel Hardware 1... Center Hub... Hub Plate 3... Blade Clamp 4... Cap Screw 5/8" x 1 1/" 316 SS 5... Flat Washer 5/8" 316 SS 7... Bolt 3/4" x 9" 316 SS 8... Flat Washer 3/4" 316 SS 9... Nut 3/4" self-locking 316 SS 00... Fan blade Monel Hardware 1... Center Hub... Hub Plate 3... Blade Clamp 4... Cap Screw 5/8" x 1 1/" monel 5... Flat Washer 5/8" monel 7... Bolt 3/4" x 8 1/" monel 8... Flat Washer 3/4" monel 9... Nut 3/4" monel 6... Lock Washer 3/4" monel 00... Fan blade 10

Fan Components 4 5 7 8 9 6 MONEL HARDWARE 7 8 9 STAINLESS HARDWARE 00 FAN BLADE FAN HUB 3 11

The Marley Cooling Tower Company 7401 W 19 Street Overland Park, KS 6613 913.664.7400 In the interest of technological progress, all products are subject to design and/or material change without notice. 1999 Marley Cooling Tower Printed in USA