Menvier Fire System MF9300

Similar documents
FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Installation, Operating and Maintenance Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Intelligent Security & Fire Ltd

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

OPERATION AND INSTALLATION MANUAL

Excel-EN Conventional Fire Control Panel

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Intelligent Security & Fire Ltd

Control Panel Engineering and Commissioning Instructions

Conventional Fire Alarm System 2014 V1.2

USER MANUAL & MAINTENANCE GUIDE OG OO

Cooper Industries (UK) Ltd

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Installation and user manual for the BiWire / Conventional Repeater Panel

Conventional Leaflets

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Installation Instructions 4 Zone Fire Panel

Application, Installation, Operation & Maintenance Manual

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

FEC400 Series. Installation Manual

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

System 800 Addressable Fire Detection & Alarm System

Surveyor Envoy-MINI 4

Fire Alarm Control Panel. System Maintenance and Log Book

Control Panel User Guide

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

User Operation Manual

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

5000 INSTALLATION GUIDE

BSR Addressable Fire Detection control panel. Installation operation manual

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

FIRE ALARM CONTROL PANEL FVC01-08

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Installation and Operating Instructions

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

user manual Document No , Revision 03 November 2015

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

SECURIT 700L PLUS ENGINEERING MANUAL

installation & maintenance manual LPCB APPROVED CFP 2/4/8 ZONE FIRE ALARM CONTROL PANEL approved document no. DFU rev 5

Precept Marine Control Panel Application Guide

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Industries. As a premier global manufacturing company, we believe that great brands are

USER MANUAL CEF AP28 CONTROL PANEL

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Control Panel User Guide

Conventional & Twin-wire Fire System

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

Fire Control Panel FS4000

SOLO Single Loop Addressable Fire Control Panel

QA16 Addressable System

The EN54 Part 2 & 4 Fire System

New Silent Alert Fire Safe System

Installation Guide for models:

GAS SUPRESSION CONTROL PANEL:

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

TECHNICAL DATA OBSOLETE

Installation Guide for models:

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Installation Manual Premier 412/816/832. Issue 10

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Accessible Toilet Alarm

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

The EN54 Part 2 and 4 Fire System

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Model 17A00 Expansion Enclosure

Xenex Conventional Fire Detection & Alarm System

Transcription:

Menvier Fire System MF9300 Eight and sixteen zone control panels Installation and User Instructions and Systems Log

IMPORTANT THIS MENVIER FIRE PANEL IS DESIGNED TO BE USED WITH POLARISED AND SUPPRESSED BELLS. DO NOT USE WITH UNSUPPRESSED BELLS, UNSUPPRESSED RELAYS OR NON-POLARISED SOUNDERS OR STROBES ETC. DO NOT CONNECT 230V MAINS DIRECTLY TO THE PCB. ELECTRICAL INSULATION TESTS SHOULD NOT BE CARRIED OUT WITH THE CABLES CONNECTED TO THE PANEL OR DETECTORS OR SOUNDERS. BEFORE MOUNTING THE PANEL PLEASE CARRY OUT THE FOLLOWING TEST: CONNECT ALL END OF LINE RESISTORS TO ZONE AND ALARM LINE TERMINALS (SEE FIG. 3 PG. 27). CONNECT A MAINS SUPPLY, THAT IS NOT SWITCHED ON, TO THE PANEL. SCREW THE CENTRE SECTION INTO PLACE ON THE BACK BOX. CONNECT THE BATTERIES AND THEN SWITCH ON THE MAINS SUPPLY. CHECK THAT ALL LIGHTS EXTINGUISH APART FROM THE POWER ON LIGHT. SELECT LAMP TEST AND CHECK THAT ALL LAMPS LIGHT AND THE INTERNAL BUZZER SOUNDS. IF ANY FAULT EXISTS THEN PLEASE CONTACT THE MENVIER SALES OFFICE. ACCESSORIES MBG913 MBG914 MBG917 MMT760 MHT790 MFR730 MID710 MDP720 MDB700 MBB244 MBM246 MBM248 MWB824 MDS724 MFS324 MWS424/DB MWS424/SB MCD524/DB MCD524/SD MXB124/DB MXB124/SB MXB224/DB MXB224/SB MAS175 MAR724 Flush Mounting Call Point Surface Mounting Call Point Weatherproof Call Points Medium Response Heat Detector High Temp. Response Heat Detector Fast Response Heat Detector Ionisation Smoke Detector Photoelectric Smoke Detector Common Detector Base 4ins (100mm) Bell 6ins (150mm) Bell 8ins (200mm) Bell 8ins (200mm) Weatherproof Bell Ceiling Sounder Flush Sounder Weatherproof Sounder - Deep Base Sounder - Shallow Base Combined Sounder/Beacon - Deep Base Combined Sounder/Beacon - Shallow Base Xenon Beacon - Deep Base (1W) Xenon Beacon - Shallow Base (1W) Xenon Beacon - Deep Base (2W) Xenon Beacon - Shallow Base (2W) Discrete Sounder/Indicator Heavy Duty Replay

IMPORTANT NOTICE RELATING TO INSTALLING AND SERVICING THE PANEL WHENEVER POWERING UP THE PANEL FROM A COMPLETELY POWERED DOWN STATE, I.E. NO MAINS OR BATTERY SUPPLY CONNECTED, THE SYSTEM RESET BUTTON MUST BE PRESSED - SEE FIG. 2 FOR THE LOCATION OF THIS PUSH BUTTON. PLEASE ALSO NOTE THAT ACCESS TO THE SERVICE AREA, BEHIND THE UPPER DOOR, SHOULD BE GAINED BY USING THE SPECIAL FORKED KEY PROVIDED. INSERT THE KEY AS SHOWN BELOW, PRESS DOWN AND THE DOOR LATCH WILL CLEAR ALLOWING THE DOOR TO BE OPENED. ATTEMPTING TO GAIN ENTRY TO THE SERVICE AREA WITH- OUT USE OF THE KEY MAY DAMAGE THE PANEL.

TABLE OF CONTENTS ACCESSORIES 1 OVERVIEW 4 SYSTEM OPERATION 4 OPERATING THE PANEL 5 SPECIALISED OPTIONS 8 APPENDIX A Fire Alarm Log 9 Details Of Installation 18 Details Of Modifications 19 APPENDIX B Faults - How To Recognise Them & What Action To Take 20 Fires - How To Recognise Them 20 APPENDIX C Installation Of The MF9308 Control Panels 21 Using The Panel Interfaces 22 Setting System Parameters 24 APPENDIX D Assembly Drawing 25 Positional Layout of Components 26 Wiring Diagram 27 Technical Specifications 28 PAGE 3

OVERVIEW This document gives details of how to install, test, use and maintain operation of your MF9300 fire alarm panel. SYSTEM OPERATION What To Do At A Glance The following information tells you what the various indicators, visible on the front panel, mean and how you should react to them. INDICATOR STATUS ACTION GENERAL FIRE ON Fire detected alarms not sounded. FLASHING Fire detected alarms sounded. ALARM LINE DELAY ON No action. Alarm line delays are set up. FLASHING Fire has been detected. Alarm delay is in action, check for fire. SYSTEM FAULT ON Refer to service provider (see front of this manual for telephone number) DISABLEMENT FLASHING No action. (s) disabled. TEST FLASHING in test. If service provider is on site take no action. Else refer to service provider (see front of this manual for telephone number). REMOTE SIGNAL ISOLATE ON No action. Remote signal output is isolated. SUPERVISOR MODE ON No action - you are in Supervisor mode - see section on `Operating The Panel`. FLASHING No action. System is self-checking. Indicator should go out within 25 seconds. GENERAL FAULT FLASHING Refer to Appendix B PAGE 4

OPERATING THE PANEL General The panel operates in 1 of 2 modes - Normal mode or Supervisor mode. In Normal mode the Supervisor mode LED is extinguished. In Supervisor mode the Supervisor LED is continuously ON. Control of the facilities at the panel is available via the keyboard. A key press is acknowledged by a blip of the internal panel buzzer. All keys that are active in the Normal mode have their legend actually on the key itself, whereas all those facilities that are active once in the Supervisor mode have their legends above the corresponding key. For example, in Normal mode pressing the SILENCE BUZZER key will silence the internal panel buzzer. However, if in the Supervisor mode pressing the same key will perform a Lamp Test. Normal Mode This is the condition the panel is generally to be found in. From the Normal mode the user may: Silence Buzzer: The user can silence the panel buzzer by pressing the SILENCE BUZZER button on the keyboard. The buzzer will then only sound approximately once every 10 seconds. NOTE that this does not silence any alarms, only the buzzer within the panel. Entering the Supervisor mode: By entering a 4 digit access code the user may get into the Supervisor mode. The access code for this panel is 2214. By pressing the numbered keys in the correct order, and then by hitting the ENTER key, the user will see the Supervisor mode indicator come on. Note that the buzzer will sound when it has recognised each key press. You are then in the Supervisor mode and may carry out additional facilities at the panel (see below). Supervisor Mode When in this mode a number of extra features are available to the user. Silence/Resound Alarms: When in the Supervisor mode this key can be used to either turn the alarms on or to silence them. It is a toggle action. So, for example, to initiate an evacuation of a site you could press the Silence/resound alarm button to cause the alarms to sound. You could then silence the alarm at a later time by pressing the same button again. Note that if the alarms are silenced but there is still a Fire condition then the internal panel buzzer will buzz every 10 seconds. Also, if the alarms are silenced then this will not prevent subsequent new fire conditions from automatically resounding the alarms. PAGE 5

Reset: This facility allows you to reset the panel. When hit, all panel indicators will light and the internal panel buzzer will sound. On the MF9304 the Fault relay output will also activate. On releasing the button the lights will extinguish, the buzzer will silence and the relay output will deactivate. For a period of approximately 25 seconds after pressing the Reset button the Supervisor mode indicator will flash. This is indicating that the panel is 'self testing'. Once the panel is ready the Supervisor mode indicator will extinguish and you can continue using the panel as you like. Disable/Enable: Test: The panel allows a supervisor to disable individual zones and/or the alarm lines. A zone which has been disabled will not be monitored for faults or for fires. Similarly, if the alarm lines are put into disablement then they will not be monitored for faults, nor would they be activated in a fire condition on a zone. (Note alarm lines are disabled in pairs i.e. lines 1/2 and/or lines 3/4). To actually disable zone/alarm lines you have to be in the Supervisor mode. Once there, press the Right Arrow key and a flashing 'cursor' will appear in the Alarm Line indicators. By repeatedly pressing the Right Arrow key you can step this 'cursor' through the Alarm Line indicators, onto the Fault indicators. Keep pressing the same key and you will step through the zones, one at a time, until eventually it returns to the Alarm line indicators, and so on. When the indicator is at the zone or alarm lines that you wish to disable/re-enable then by simply pressing the Disable/Enable button in zone/alarm lines will be toggled accordingly. The Disablement indicator will flash, the internal buzzer will sound every 10 seconds and the corresponding Fault indicator(s) will light continuously for any zone or alarm line that is disabled. You may then use the Right Arrow key to move on and disable/re-enable further zones/alarm lines as required. Note that a disablement is not cancelled by a reset or a removal of power to the panel. The fire panel will allow the supervisor to put any zone into a test mode. To do this go into the Supervisor mode. Then press the Right Arrow key once and a flashing 'cursor' will appear in the Alarm indicators. Continue pressing the Right Arrow key until the 'cursor' reaches the zone that you want to put into test. Then press the Test button. The Test indicator will begin to flash, the internal panel buzzer will buzz at 10 second intervals and the Fault indicator of the zone concerned will light continuously. That particular zone is now in the Test mode. When in test mode a detector/manual call point can be put into fire on that particular zone. The panel will recognise the fire condition and sound the alarms for 2 seconds. Then the panel will automatically reset the zone, in order to try and clear the fire condition. If the zone resets successfully then the alarms will sound again for 2 seconds. You can then go on and test the next detector/manual call point on the zone. If the zone fails to reset successfully, maybe due to a faulty detector or such like, then the panel will keep on trying to reset the zone for 2 minutes. If it has still failed at the end of this period then that zone immediately goes into fire. Note that the alarm lines cannot be put into the test condition. PAGE 6

The fact that a zone is in test will not prevent the panel from recognising and acting upon fires or faults in other zones. To take a zone out of the test mode you must go into the Supervisor mode and then press Reset. Remote Signal Isolate: To isolate the Remote Signal output press the Remote Signal Isolate button, whilst in Supervisor mode. The Remote Signal Isolate indicator will light, the Disablement indicator will flash and the internal panel buzzer will buzz every 10 seconds. To re-enable the Remote signal again at a later time simply press the Remote Signal Isolate button again. The corresponding indicators will extinguish and the panel buzzer will silence itself. Note that the remote signal isolate facility is not cancelled by a system reset. Lamp Test Facility: It is possible to test the indicators and the internal panel buzzer manually. To do this from within the Supervisor mode the Lamp Test button should be pressed. For the period that the button is kept depressed all panel indicators should light and the internal buzzer should sound. Once the button is released the panel will return to the condition it was in prior to the lamp test. Exiting from the Supervisor Mode: This mode will automatically exit if no key press is detected for a period of greater than 15 seconds. Alternatively, if you have finished in the Supervisor mode you may simply press ENTER. In either case the Supervisor mode indicator will extinguish and the panel will be back in the Normal mode. PAGE 7

SPECIALISED OPTIONS Certain additional features may be set up by the service provider at the commissioning stage. They are as follow: Non-latching This feature is available on zone 1 and is selectable at commissioning by use of a switch in the panel (see Appendix C for selecting this feature). Note that this facility is additional to the requirements of EN54. When activated any fire condition on zone 1 will not be latched i.e. once the condition has cleared, by whatever means, at the detecting device, the panel will automatically come out of the fire state for zone 1 - no user intervention would be required at the panel. Further details of this interface are available on request. Coincidence Detection This feature is available on zone 2 and is selectable at commissioning by use of a switch in the panel (see Appendix C for selecting this feature). On the first detector going into fire the panel indicates the event by sounding the buzzer and by having a double flash followed by a pause on the zonal fire indicator. Once the second detector goes into fire the full fire condition is initiated by the panel. Using coincidence detection on zone 2 does not affect the way in which fires are recognised or acted upon from other zones in the system. Note also that a manual call point pressed on any zone will put the panel into the fire condition immediately, irrespective of whether coincidence detection is active. Alarm Line Delays Delays can be introduced between the panel recognising a detector fire signal and the alarms being sounded. That delay is selectable at commissioning by use of switches in the panel (see Appendix C). The length of the delay can be set anywhere between 0 minutes i.e. no delay, and 7 minutes, in 1 minute intervals. When the panel has alarm line delays set up the ALARM LINE DELAY indicator will be permanently ON. When a fire is detected on a zone the ALARM LINE DELAY indicator will flash, the buzzer will sound intermittently and the appropriate zonal fire indicator will flash. After the set delay period the panel will switch the alarms ON, unless the panel is reset. Note that, delays do not affect fire signals from manual call points. These signals are acted upon immediately. NOTE: AUX contacts are also delayed when this facility is active. PAGE 8

FIRE ALARM SYSTEM LOG APPENDIX A It is recommended that this book is maintained by a responsible executive and that every event affecting the installation should be recorded. An event should include false alarms, failures, tests, temporary disconnections, the dates of installing engineer s visits and a note of any outstanding work or conditions. Date Event Action required Signed PAGE 9

Date Event Action required Signed PAGE 10

Date Event Action required Signed PAGE 11

Date Event Action required Signed PAGE 12

Date Event Action required Signed PAGE 13

Date Event Action required Signed PAGE 14

Date Event Action required Signed PAGE 15

Date Event Action required Signed PAGE 16

Date Event Action required Signed PAGE 17

DETAILS OF INSTALLATION No. 1 No. of Call Points No. of Smoke Detectors No. of Heat Detectors Location 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TOTAL CURRENT TOTAL ALARM LOAD: No. OF SOUNDER BELLS ELECTRONIC OTHER OTHER DETAILS OF EQUIPMENT: THIS SYSTEM HAS BEEN INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF EN54 SIGNED DATE FOR THIS SYSTEM HAS BEEN COMMISSIONED IN ACCORDANCE WITH THE REQUIREMENTS OF EN54 SIGNED DATE FOR PAGE 18

APPENDIX B Faults - How To Recognise Them And What Action To Take All fault conditions on the fire alarm panel will be indicated by the flashing of the general fault indicator (positioned immediately below the large red fire indicator) and the activation of at least one other fault-specific indicator. By determining which fault-specific indicator is active and by referring to the table shown you can decide on what action to take. INDICATOR FLASH RATE CONDITION ACTION ACTIVE COMPARED TO GENERAL FAULT INDICATOR (G.F.I.) POWER FAULT flashing Faster than G.F.I. Battery Fault. Refer to service provider. Short flash, long pause. Mains fail. Check mains supply to panel is switched on. ZONAL FAULT Flashing Slower than G.F.I. open circuit. Refer to service provider. Faster than G.F.I. short circuit. Refer to service provider. Same as G.F.I. Detector Check detectors removed from in zone are base correctly fitted in their bases. ALARM FAULT flashing Slower than G.F.I. Alarm open circuit Refer to service provider. Faster than G.F.I. Alarm short circuit. Refer to service provider. EARTH FAULT on Earth Fault in Refer to service System provider SYSTEM FAULT on System fault Refer to service occurred provider Fires - How to Recognise Them All fire conditions on the fire panel will be indicated by the flashing of the Main Fire Indicator (large red indicator) and the activation of at least one Fire Indicator. Main Fire Indicator on but not flashing Main Fire Indicator flashing Fire Indicator on but not flashing Fire Indicator flashing Fire Indicator 'double flash' Fire detection but alarms not sounded (due to delay or coincidence detection) Fire detected and alarms sounded Call Point Fire Detector Fire 1st stage coincidence detection PAGE 20

APPENDIX C Installation Of The MF9300 Control Panels General Points: Before actually installing your MF9300 panel please note the following points about the system: The wiring for each of the zones and alarm lines is to be a 2 core parallel circuit with the end of line resistor fitted to the end of the circuit. No 'spurs' or 'tee offs' are permitted. The wiring diagram (Fig.3) gives more details. If a zone is not to be used at all then the end of line resistor must be left in the relevant zone terminal blocks in the panel. All equipment used must be of the open circuit type. Manual call points used in the system (MBG913/MBG914) are polarised. Use the connection details accompanying the manual call points in order to ensure that the correct polarity of connections is observed at all times. Also, make sure that the 'MF9300' terminals are used on the manual call points. All cables should be tested for Earth fault before connection to the panel. Do not use a MEGGER on any cable after connection to any equipment including the fire panel. The maximum load permitted on each of the 4 alarm sounder circuits is specified in the Technical Specification (Appendix D, fig.4). The load should be spread equally across the circuits. All sounders must be polarised, with the correct polarity of connections being observed at all times. Refer to the wiring diagram (Appendix D, fig.3) and the instructions with the relevant sounders for the appropriate connection details. All cables entering or leaving the panels must do so via the 'knock-out' positions provided. Additional Instructions for Electromagnetic Compatibility When used as intended this product complies with EMC Directive (89/336/EEC) and the UK EMC regulations 1992 (SI 2372/1992) by meeting the limits set by the standards BS 5406 (Pts 2 & 3) 1988, EN50082-1 1991 and EN50081-1 1992. The following installation guidelines must be followed. 1. External cables must be connected using the cable entries or knockouts provided. 2. When routing external cables inside the product they must be a) Kept as short as possible b) Routed close to the housing c) Kept as far as possible from the electronics Any modifications other than those stated in this manual, or any other use of this product may cause interference and it is the responsibility of the user to comply with the EMC and Low Voltage Directives. Installing The Panel: Follow the steps shown here, in conjunction with the assembly diagram shown in this manual (Fig.1): 1. Unscrew the battery cover plate and the centre section from the back box and place the centre section somewhere safe. Take the back box and remove/drill any knockouts that are to be used, either on the top or rear of the enclosure. Note that specific knockout positions should be used for the AC mains supply. These positions are indicated both on the back box itself and on the assemly diagram (Fig 1) Note also that the cables should only enter or leave the enclosure via positions indicated by the knockouts. Do not drill additional holes in the enclosure. Fix the back box to the wall. Use the 4 fixing holes in the back of the enclosure if it is to be mounted proud of the wall. Alternatively, for flush fixing, use the 5mm mounting holes 4 off around the lip of the erar enclosure to mount the panel. PAGE 21

2. Connect the batteries together using the battery connectors contained in the accessories bag - note the polarity of the connections on the assembly diagram (Fig.1). Fit the batteries into the battery compartment of the rear enclosure. 3. Ensure that all external wiring that is to be used is available within the back box and connect them to the correct terminal blocks on the interface board (use Fig.3 for guidance). Connect the inter board connections (one 8 way connector from the power supply board to TB2 on the main board, one 14 way connector from the interface board to TB1 on the main board and one 26 way ribbon connector from the interface board to the main board) (Fig 2). Wire the AC mains input to the mains terminal block within the rear enclosure. Connect the battery connector to the Power Supply PCB (ensure that the clip on the connector socket fits with the catch on the connector plug on the PCB). A small spark may be seen at the connector when this is done - this is quite normal. The internal buzzer should sound and the green POWER LED should flash (other LEDs may also be lit - this too is quite normal at this stage). Fix the central section to the rear enclosure using the 4mm screws provided (4 off). Apply the AC mains supply and press the system reset button (see Fig 2). If all is well the green POWER LED should now be permanently ON. 4. Fix the battery cover plate to the rear enclosure using the 3mm screws provided (6 off). 5. Fit the lower door. 6. Carry out the testing of the system. NOTE that all manual call points (MBG913/MBG914) used in the system must be individually tested for correct operation. Then when satisfied that all is working correctly fit the upper door - ensure that the door clicks into place and locks there. WARNING: Operating up of a panel after installation should only be carried out by a suitably qualified/trained person. Live parts are exposed by this operation so ensure that the mains supply is switched off before attempting to service any of the parts inside the panel. Routine testing of the system should be carried out as recommended in BS5839 part 1: 1988 (Clause 29). Using The Panel Interfaces: The panels provide the following interfaces options. Fig.2 shows the location of the interface terminal blocks on the circuit board. Note that these features are in addition to the requirements of EN54. Auxiliary DC Output A 24 VDC output is provided. This output may be switched via the auxiliary relays or used to drive external relays via the auxiliary zone/common outputs. This output is fused to protect against wiring faults but is UNMONITORED by the panel i.e. if this fuse ruptures the panel will not register a fault. PAGE 22

Class Change A pair of contacts are provided for a class change facility. By short circuiting these contacts via a switch, pulse unit, time clock or by other means, the alarms will sound without illuminating the fire lights. The alarms will cancel when the short circuit is removed. No voltage should be applied to these terminals. Auxiliary Common Output This is a 'solid state' semiconductor switch which operates on the activation of a fire on any latching zone by 'pulling down' this output to 'zero volts' (Note, the activation does not occur for fires on non-latching zones). This makes the output suitable for driving an external 24V relay with a coil current of 10mA, maximum, which can be used for operating door release units etc. This output is not activated by Sound Alarms or Class Change. Auxiliary Fault Relay A1 Amp (max), 24 VDC (resistive) voltage free single pole changeover relay is provided. The relay will operate on the activation of any fault registered by the panel. 240V MUST NOT BE SWITCHED WITH THIS RELAY. Remote Signal Relay A1 Amp (max), 24VDC (resistive) voltage free single pole changeover relay is provided, operating on the activation of any zone, after any delays are taken into account on that zone. The relay is for signalling to a remote location, of for operation of an autodialler. Where it is required to signal to a control station an interface unit, supplied by the control station operator, will be required. This relay is not activated during Sound Alarms, nor during Class Change. 240V MUST NOT BE SWITCHED WITH THIS RELAY. An isolate facility is provided to enable the panel to be tested without operating the remote signal relay. This facility is available in the supervisor mode from the front panel. When pushed the Remote Signal Isolate LED will light and the internal buzzer will sound every 10 seconds. Note that doing a system Reset will not cancel the isolate facility. Repeater Output A2 wire serial link interface is provided for connecting to a repeater panel. Further details of this interface are available on request. Do not exceed the maximum output current rating stated in the Technical Specification (Appendix D) PAGE 23

Setting System Parameters Certain facilities that can be set up by the service provider at commissioning. They are as follows: Non-latching To enable this facility gain access to the service area of the panel and push the Non-latching zone switch down (Fig.2). Then press the SYSTEM RESET switch. The panel will reset and the non-latching zone feature will be available on zone 1. Coincidence Detection To enable this facility gain access to the service area of the panel. On the bit-switch (see Fig.2) move switch 4 to the ON position. Then press the SYSTEM RESET button. The panel will reset and the coincidence detection feature will then be available for use on zone 2. Alarm Line Delays Again, to enable alarm line delays gain access to the service area. The delay period is set by adjusting the positions of the bit switches (see Fig.2) as follows: SWITCH POSITION 1 2 3 DELAY (MINS) 0 OFF OFF OFF 1 ON OFF OFF 2 OFF ON OFF 3 ON ON OFF 4 OFF OFF ON 5 ON OFF ON 6 OFF ON ON 7 ON ON ON After the delay period is selected press the SYSTEM RESET switch. The panel will reset, the ALARM LINE DELAY indicator will light and the delays will be used when appropriate. PAGE 24

APPENDIX D Assembly drawing for MF9308 & MF9316 Mains Terminal block Transformer Transformer wires colour coded Small door Battery link wire ❻ Battery +ve (red) ❷ ❹ ❸ ❺ Middle moulding Battery cover plate Large door Mains conduit entry Cable clamp Transformer connector connector ❶ ❷ Battery connector (polarised) Battery -ve (black) Batteries 2 x 12V, 12Ah Interface board Alarm connector Power connector Battery connector Power supply board Back box Battery compartment only FIG 1 PAGE 25

Positional layout of components for MF9308 & MF9316 panels L 8 WAY CONNECTION TO POWER SUPPLY BOARD (TB2) RIBBON 26 WAY CONNECTION TO TERMINAL BLOCK BOARD 14 WAY CONNECTION TO TERMINAL BLOCK BOARD (TB1) FUSED MAINS CONNECTOR ALARM 1 FUSE 3.15A ALARM 2 FUSE 3.15A ALARM 3 FUSE 3.15A ALARM 4 FUSE 3.15A AUX DC FUSE 1A NON LATCH ZONE ALARM DELAY COIN DETN SYSTEM RESET N E FIRE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 GENERAL FAULT ZONE LED'S ALARM LINE DELAY DISABLEMENT SYSTEM FAULT ALARMS 1 2 3 4 TEST EARTH FAULT POWER POWER FAULT SUPERVISOR MODE REMOTE SIGNAL ISOLATE FIG 2 PAGE26

End of line 12K resistor L1 C6 C6 L1 + End of line 12K resistor L1 L1 Fire system 9308/9316 wiring diagram To door release units (note 4) 24v 10mA coil C5 C6 MDB700 Detector Bases C5 C6 L1 L1 L1 C5 C5 L1 + OUT To applications requiring relay with isolating facility - 9300 OUT MBG 913/914 Break Glass Units - 9300 IN (note 3) + + Alarm sounders (Note 1) And subsequent Alarm lines + - + - + - + NC C NO NC C NO Alarm - + - + - + - + - + - + - + - + - + 11 - + - + - + - + - + - + - + - + - + - + Alarm Alarm Alarm 16 15 14 13 12 10 4 3 2 1 9 8 7 6 5 4 3 2 1 C6 + + IN To REPEATER PANEL (NOTE 4) L1 + C5 MDB700 + NC NC Heavy duty relay MAR724 And subsequent s Fault C C 230v AC +/- 10% 50/60Hz FIG 3 L1 - To volt free contacts Repeater Transmit Repeater Ground Class change (note 2) Auxiliary common output (note 2) Auxiliary 24v DC output Earth Remote Signal Relay Fault Relay Notes 1. All sounders must be polarised and suppressed. 2. Connection details for door release units when required. 3. Polarity of connections must be observed. Use 9300 negative connections. 4. Connection details for repeater panels when required. PAGE 27

TECHNICAL SPECIFICATIONS MF9308 MF9316 No. of zones 8 16 No. of alarm circuits 4 4 Mains input voltage System operating voltage Monitoring s Alarms End of line elements s Alarms Maximum loadings s (per zone) Alarm lines 230 VAC +/- 10% 50Hz 24 VDC Open, short circuit and detector removed Open, short circuit and detector removed 12K resistor supplied with panel 12K resistor supplied with panel Break glass units, heat detectors and smoke detectors (Combined max - 32) 500mA/line (2A max) User controls 8 key keypad providing Access level 1 and Access level 2 control - entry to Access level 2 by 4 digit keycode Fault indications Power Fire indicators Alarm Earth fault System fault Auxilliary DC output Auxilliary fault relay Remote signal relay Auxilliary common output Repeater drive capacity Class change facility Terminal conductor capacity Mains fail, battery disconnected, battery low/short circuit Open, short circuit and detector removed Open/short circuit Earth fault in system Controller error, code/data/comms error etc Large common fire LED plus individual zonal LED s 24 VDC 350mA max (fused, but unmonitored) 1A 24 VDC resistive, single pole c/o contacts 1A 24 VDC resistive, single pole c/o contacts - isolate facility available Active pull-down to 0V 1 repeater via 2 wire serial link 1 pair terminals - short to sound alarms 0.5mm sq. to 2.5mm sq. maximum Integral charger (ma) 1 Battery capacity (AH) 12 Battery type Standby on mains failure Recharge period Dimensions 2 x 12V Sealed Lead Acid (Supplied) Recommended replacement period 4 years 72 Hours backup operating in the normal mode followed by 1/2 hr in the fire condition FIG 4 24 hours Approx. 395mm(W) x 325mm(H) x 135mm(D) PAGE 28

For service please call: Tel: Service agreement number Cooper Lighting and Security Ltd. Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB, United Kingdom Lighting and Security Sales General Export Tel: +44 (0)1302-303303 +44 (0)1302-321541 +44 (0)1302-303250 Fax: +44 (0)1302-367155 +44 (0)1302-303220 +44 (0)1302-303251 Email: sales@cooper-ls.com info@cooper-ls.com export@cooper-ls.com PINST FA9308/V www.cooper-ls.com