TECHNICAL DATA. UL/C-UL Listed as a standard response. horizontal ceilings. Listings up to a OBSOLETE

Similar documents
freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

microfast quick response extended coverage hsw sprinkler vk606

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA OBSOLETE

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

quick response horizontal sidewall sprinkler vk360 (K8.0)

micromatic Standard response Horizontal Sidewall sprinkler

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

microfast and microfasthp quick conventional sprinklers

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

micromatic Standard response Horizontal Sidewall sprinkler

TECHNICAL DATA. Page 1 of 6

standard response fusible link sidewall sprinkler VK112 (K5.6)

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

standard response dry horizontal sidewall sprinklers

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA vk470 (K3.0)

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

Microfast quick response Fusible element hsw sprinkler

freedom residential concealed pendent Sprinkler vk458 (K7.4)

microfast sr/qr extended coverage pendent sprinkler

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

freedom residential pendent sprinkler vk466 (K5.2)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

standard response elo upright and pendent sprinklers (storage-density/area)

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

microfast quick response Pendent sprinkler VK302 (K5.6)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

standard response elo upright sprinkler

standard response/ quick response extended coverage

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

micromatic standard response stainless steel sprinklers

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

standard response Fusible Link Upright sprinkler VK204 (K8.0)

freedom residential flush pendent sprinkler vk476 (K4.9)

freedom residential Upright sprinkler vk467 (k4.9)

freedom residential concealed pendent sprinkler vk474 (K5.8)

micromatic standard response Upright sprinkler VK100 (K5.6)

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

Transcription:

Sprinkler 42 a UL/C-UL Listed as a standard response sprinkler for use in Light Hazard occupancies with extended areas of coverage below smooth flat, horizontal ceilings. Listings up to a maximum of 250 psi wwp. UL/C-UL Listed as a quick response sprinkler for use in Light and Ordinary hazard occupancies with standard areas of coverage below smooth, flat, 1. PRODUCT NAME horizontal ceilings. Listings up to a Viking Microfast /MicrofastHP Model maximum of 250 psi wwp. M-5 Horizontal Sidewall Sprinkler SIN UL/C-UL Listed as a quick response VK442 sprinkler for use in Light Hazard occupancies with extended areas of cover- Sprinkler identification number provided in accordance with the 1999 edition of NFPA 13, Section age below smooth flat, horizontal ceilings. Listings up to a maximum of 250 3-2.2. 2. MANUFACTURER psi wwp. The Viking Corporation 210 N. Industrial Park Road UL/C-UL Listed as a quick response, Hastings, Michigan 49058, U.S.A. specific application sprinkler for use in Light Hazard occupancies with extended areas of coverage when in- Telephone: (616) 945-9501 (877) 384-5464 stalled below smooth, flat ceilings with Fax: (616) 945-9599 slopes ranging from a 2/12 (9.5 ) to e-mail: techsvcs@vikingcorp.com 4/12 (18.4 ) pitch. Maximum 175 psi 3. PRODUCT DESCRIPTION wwp. Viking Microfast /MicrofastHP Horizontal Sidewall Sprinkler SIN VK442 is a tions below smooth, flat, horizontal UL/C-UL Listed for residential applica- small, high-sensitivity glass-bulb sprinkler listed for many different applica- the listings. Maximum 175 psi wwp. ceilings and sloped ceilings allowed by tions: Specific Application Listing Note When Viking Microfast Quick Response Horizontal Sidewall Sprinkler SIN VK442 is installed below smooth, flat ceilings with slopes ranging from 2/12 to 4/12 (9.5 to 18.4 ), it is UL/C-UL Listed as a Specific Application Sprinkler for extended areas of coverage in Light Hazard occupancies only. Maximum 175 psi wwp. In these applications, Sections 7-2.3.2.4 and 7-2.3.2.5 of the 1999 Edition of NFPA-13 do not apply regarding System Area of Operation. Viking Microfast Quick Response Horizontal Sidewall Sprinkler SIN VK442 should be installed according to the areas of coverage, and flows and pressures listed in Approval Chart 1 on page 42 d. Refer also to Figure 3, Installation Notes, on page 42 c. Sprinkler Temperature Classification Nominal Sprinkler Temperature Rating (Fusing Point) 2 Maximum Ambient Ceiling Temperature 1 Bulb Color Ordinary 135 F (57 C) 100 F (38 C) Orange Ordinary 155 F (68 C) 100 F (38 C) Red Intermediate 175 F (79 C) 150 F (65 C) Yellow Intermediate 200 F (93 C) 150 F (65 C) Green High 286 F (141 C) 225 F (107 C) Blue Sprinkler Finishes: Brass, Bright Brass, Chrome-Enloy (patents pending), White, Navajo White, Black, and Black Teflon Corrosion-Resistant Coatings 3 : White, Navajo White, Black, and Black Teflon Footnotes 1 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 2 Temperature rating is stamped on the deflector. 3 The corrosion-resistant coatings have passed standard corrosion tests required by particular approving agencies. Refer to the approval charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. The coatings indicated are applied to the exposed exterior surfaces only. NOTE: The spring is exposed on the Teflon coated and Polyester coated sprinklers. The sprinkler is available with several different finishes and temperature ratings to meet varying design requirements. The orifice design allows efficient use of available water supplies for hydraulically designed fire-protection systems. The small, rugged 3 mm glass bulb and special deflector combine speed of operation and area of coverage to meet quick response, extended coverage, and residential sprinkler standards. The special Polyester and Teflon coatings are available for use in decorative applications. In addition, these two finishes are listed as corrosion-resistant finishes for protection against many corrosive environments. During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 4. LISTINGS AND APPROVALS Refer to the Decision Tree in Figure 1 on page 42 b and Approval Charts 1, 2, and 3 for listings. Minimum Operating Pressure: For Quick Response Applications with Standard Areas of Coverage: 7 psi (48,3 kpa). For Extended Coverage and QREC Applications: Refer to Approval Chart 1 for minimum water supply requirements and maximum area of coverage. For Residential Applications: Refer to Approval Charts 2 and 3 for minimum water supply requirements and maximum area of coverage. Refer also to Figures 4 through 6 for installation guidelines. Glass-bulb fluid temperature rated to -65 F (-55 C). Refer to the approval charts for maximum rated water working pressure. The high pressure (HP) sprinkler can be identified by locating the number "250" on the deflector. Factory tested hydrostatically to 500 psi (3 448 kpa). Spring: U.S.A. Patent No. 4,167,974 Deflector: U.S.A. Patent No. 4,296,816 Testing: U.S.A. Patent No. 4,831,870 Bulb: U.S.A. Patent No. 4,796,710 Thread Size: ½" NPT (15 mm) Nominal K-Factor: 5.5 U.S. or 5.6 U.S. (7,9 or 8,1 metric*) (Continued on page 42 c.) Note: Units of measure in parentheses may be approximations. Replaces page 42 a-d, dated October 1, 2000. Also refer to the appropriate Viking general care, installation, and maintenance guide for Form No. F_022697 the particular application type.

Sprinkler 42 b Sprinkler SIN VK442 is UL/C-UL Listed for use in commercial applications below smooth, flat, horizontal ceilings and sloped ceilings allowed by the listings: Refer to Approval Chart 1 on page 42 d for details. SIN VK442 Sprinklers manufactured after July 12, 2002 to be installed in new residential sprinkler systems. Sprinkler SIN VK442 is UL/C-UL Listed for use in residential occupancies below smooth, flat, horizontal ceilings and sloped ceilings allowed by the listings as follows: SIN VK442 Sprinklers manufactured after July 12, 2002 to be installed in existing residential sprinkler systems where water supplies are adequate to provide a minimum density of.05 gpm/sq. ft. over the design area.*** For use below smooth, flat, horizontal ceilings with the deflector located 6 to 12 (152 mm to 305 mm) below the ceiling. For use below ceilings with slopes up to and including an 8/12 (33.7 ) pitch with the deflector located 4 to 6 (102 mm to 152 mm) below the ceiling. The sprinkler must be installed at the peak with spray directed down the slope. SIN VK442 Sprinklers to be used as replacement sprinklers in existing residential sprinkler systems designed and installed to provide a minimum density of.04 gpm/sq. ft. over the design area.*** All SIN VK442 Sprinklers manufactured before July 12, 2002. For use below smooth, flat, horizontal ceilings with the deflector located 6 to 10 (152 mm to 254 mm) below the ceiling. For use below ceilings with slopes up to and including a 6/12 (26.6 ) pitch with the sprinkler installed at the peak with spray directed down the slope and the deflector located 4 to 6 (102 mm to 152 mm) below the ceiling. For use below ceilings with slopes up to and including a 6/12 (26.6 ) pitch with the sprinkler installed on the side with spray directed across the slope and the deflector located 6 to 10 (152 mm to 254 mm) below the ceiling. Refer to Approval Chart 2 on page 42 e for minimum water supply requirements and maximum areas of coverage. Refer to Approval Chart 3 on page 42 f for minimum water supply requirements and maximum areas of coverage. New residential sprinkler systems using SIN VK442 Sprinklers manufactured after July 12, 2002 must provide a minimum density of.05 gpm/sq. ft. over the design area. ***Refer to the appropriate technical data page for all SIN VK442 Sprinklers to be installed as replacement sprinklers in existing residential sprinkler systems designed prior to implementation of the.04 density requirement on October 31, 2000. Figure 1: Decision Tree

Sprinkler 42 c (WITH QR, EC, QREC, RESIDENTIAL, Nominal U.S. K-Factor provided in accordance with the 1999 edition of NFPA 13 Section 3-2.3. * Metric K-Factor shown is for use when pressure is measured in kpa. When pressure is measured in BAR, multiply the metric K-Factor shown by 10.0. Overall Length: 2-11/16" (68,3 mm) SPRINKLER MATERIALS Frame: Brass Castings UNS-C84400 Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Polyester Coated Sprinklers Belleville Spring: Nickel Alloy, exposed Screw: Brass UNS-C36000, Nickel plated. Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Teflon Coated Sprinklers Belleville Spring: Nickel Alloy, exposed Screw: Brass UNS-C36000, Nickel plated. Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400, Teflon Coated ACCESSIES Refer to the SPRINKLER ACCES- SIES section of the Viking Engineering and Design Data book. Notes: 1. In sloped ceiling installations, this sprinkler is listed for installation at the Microfast /MicrofastHP Horizontal Sidewall Sprinkler SIN VK442 high-point intersection of the wall and the ceiling. In sloped ceiling installations, the spray must be directed down the slope. Spray may NOT be directed across the slope. 2. Listed area of coverage for sloped ceilings corresponds to ceiling slope. (For sloped ceiling applications, actual floor coverage will be less than the listed area.) Distance from ceiling to deflector: 4" to 6" (102 mm to 152 Microfast /MicrofastHP Horizontal Sidewall Sprinkler SIN VK442 Installed with a top of deflector par- 18.4 Max. mm). Always align Microfast Horizontal Sidewall Standard 1/8" (3,1 mm) allel with the ceiling. Sprinkler SIN VK442 installed Surface-Mounted Escutcheon with the Micromatic Model E-1 or E-2 Recessed Escutcheon Figure 3: Sloped Ceiling Installation--for Non-Residential Applications only. Microfast /MicrofastHP Horizontal Sidewall Sprinkler SIN VK442 Installed with a Micromatic Model E-1 Escutcheon Recessed Microfast /MicrofastHP Horizontal Sidewall Sprinkler SIN VK442 Installed with a Microfast Model F-1 Adjustable Escutcheon Figure 2

Sprinkler 42 d Thread Size Nominal K-Factor Overall Length Sprinkler Base Sprinkler Deflector Style Inch mm U.S. 1 metric 2 Inch mm Part Number 3 Identification Number (SIN) 4 Horizontal Sidewall ½ 15 5.6 8,1 2-11/16 68,3 09533 VK442 Temperature KEY Finish Escutcheon (if applicable) Approval Chart 1 For Non-Residential Applications Only Microfast /MicrofastHP Horizontal Sidewall Sprinkler Quick Response Standard Coverage Applications for Light or Ordinary Hazard Occupancies. Deflectors must be located 4" to 12" (102 mm to 305 mm) below smooth, flat, horizontal ceilings only. Listings 5 UL C-UL 7 NYC 9 A1X, B1W A1X,B1W A1X Maximum 250 PSI WWP. Standard Response Extended Coverage Applications for Light Hazard Occupancies Only. Installed with the deflectors located 6" to 12" (152 mm to 305 mm) below smooth, flat, horizontal ceilings only. Maximum 175 PSI WWP. Maximum Areas of Coverage 6 Width x Throw Minimum Water Supply Requirements 6 F1W F1W 16' x 20' (4,9 m x 6,2 m) 32 gpm @ 32.7 psi (121,1 L/min @ 225,1 kpa) Standard Response Extended Coverage Applications for Light Hazard Occupancies Only. Installed with the deflectors located 6" to 12" (152 mm to 305 mm) below smooth, flat, horizontal ceilings only. Maximum 250 PSI WWP. 16' x 16' (4,9 m x 4,9 m) 26 gpm @ 21.6 psi (98,4 L/min @ 148,6 kpa) F1W F1W 16' x 18' (4,9 m x 5,5 m) 29 gpm @ 26.8 psi (109,8 L/min @ 184,9 kpa) F1W F1W 16' x 20' (4,9 m x 6,2 m) 32 gpm @ 32.7 psi (121,1 L/min @ 225,1 kpa) F1W F1W Quick Response Extended Coverage Applications for Light Hazard Occupancies Only. Installed with the deflectors located 6" to 12" (152 mm to 305 mm) below smooth, flat, horizontal ceilings. Maximum 175 PSI WWP. 16' x 16' (4,9 m x 4,9 m) 26 gpm @ 21.6 psi (98,4 L/min @ 148,6 kpa) E1W E1W C2W 16' x 18' (4,9 m x 5,5 m) 29 gpm @ 26.8 psi (109,8 L/min @ 184,9 kpa) E1W E1W C2W 16' x 20' (4,9 m x 6,2 m) 32 gpm @ 32.7 psi (121,1 L/min @ 225,1 kpa) D1W D1W D2W Quick Response Extended Coverage for Light Hazard Occupancies Only. Installed with the deflectors located 6" to 12" (152 mm to 305 mm) below smooth, flat, horizontal ceilings only. Maximum 250 PSI WWP. 16' x 16' (4,9 m x 4,9 m) 26 gpm @ 21.6 psi (98,4 L/min @ 148,6 kpa) E1W E1W C2W 16' x 18' (4,9 m x 5,5 m) 29 gpm @ 26.8 psi (109,8 L/min @ 184,9 kpa) E1W E1W C2W 16' x 20' (4,9 m x 6,2 m) 32 gpm @ 32.7 psi (121,1 L/min @ 225,1 kpa) D1W D1W D2W Specific Application, Quick Response Extended Coverage for Light Hazard Occupancies Only. Installed with the deflector located 4" to 6" (102 mm to 152 mm) below smooth, flat, sloped 8 ceilings with slopes from 2/12 through 4/12 (9.5 to 18.4 ) pitch. Sprinkler must be located at the high-point intersection of the wall and the ceiling with spray directed down the slope. Refer to Figure 3 on page 42 c. Maximum 175 PSI WWP. 16' x 16' (4,9 m x 4,9 m) 26 gpm @ 21.6 psi (98,4 L/min @ 148,6 kpa) E1W E1W 16' x 18' (4,9 m x 5,5 m) 29 gpm @ 26.8 psi (109,8 L/min @ 184,9 kpa) E1W E1W 16' x 20' (4,9 m x 6,2 m) 32 gpm @ 32.7 psi (121,1 L/min @ 225,1 kpa) D1W D1W Approved Temperature Ratings A - 135 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (93 C), and 286 F (141 C) B - 135 F (57 C), 155 F (68 C), 175 F (79 C), and 200 F (93 C) C - 135 F (57 C), 155 F (68 C), and 175 F (79 C) D - 135 F (57 C) and 175 F (79 C) E - 135 F (57 C) and 155 F (68 C) F - 155 F (68 C) Approved Finishes 1 - Brass, Bright Brass, Chrome-Enloy, White Polyester 10, Navajo White Polyester, Black Polyester 10, and Black Teflon 10 2 - Brass, Bright Brass, Chrome-Enloy, White Polyester 10, and Navajo White Polyester Approved Escutcheons W - Standard surface-mounted escutcheons or the Microfast Model F-1 Adjustable Escutcheon 11, or recessed with the Micromatic Model E-1 or E-2 Recessed Escutcheon X - Standard surface escutcheons or the Microfast Model F-1 Adjustable Escutcheon 11 Footnotes 1 Nominal U.S. K-Factor provided in accordance with the 1999 edition of NFPA 13, Section 3-2.3. 2 Metric K-Factor shown is for use when pressure is measured in kpa. When pressure is measured in BAR, multiply the metric K-Factor shown by 10.0. 3 Base part number is shown. For complete part number, refer to Viking's current price schedule. 4 Sprinkler identification number provided in accordance with the 1999 edition of NFPA 13, Section 3-2.2. 5 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 6 For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" for the next larger listed area of coverage with sprinklers of similar K-Factor. Flow and pressures listed are per sprinkler. 7 Listed by Underwriter's Laboratories, Inc. for use in Canada. 8 Listed area of coverage measured along ceiling slope. Consult Figure 3 on page 42 c for installation notes. 9 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Volume XVI. 10 UL/C-UL Listed as corrosion resistant. 11 The Microfast Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. NOTE: Must be installed with deflector located between 4" and 6" (102 mm and 152 mm) from walls. Exception: Deflector may be located less than 4" (102 mm) from the wall in which the sprinkler is installed. Always install with the top of the deflector aligned parallel with the ceiling or roof. A1X

Sprinkler 42 e Thread Size Nominal K-Factor Overall Length Sprinkler Base Sprinkler Identification Deflector Style Inch mm U.S. metric 1 Inches mm Part Number 2 Number (SIN) 3 Horizontal Sidewall ½ 15 5.5 7,9 2-11/16 68,3 09533 VK442 Approval Chart 2 For Residential Applications Only Microfast Horizontal Sidewall Sprinkler Maximum 175 PSI WWP This page applies for all SIN VK442 Sprinklers manufactured after July 12, 2002 to be installed in new residential sprinkler systems, and SIN VK442 Sprinklers manufactured after July 12, 2002 to be installed in existing residential sprinkler systems where water supplies are adequate to provide a minimum density of.05 gpm/sq. ft. over the design area. When using Sprinkler SIN VK442 as a replacement sprinkler in an existing residential sprinkler system designed with sprinklers manufactured prior to July 12, 2002, or when using SIN VK442 Sprinklers manufactured before July 12, 2002 for new residential sprinkler systems, refer to pages 42 f-g. Installed below smooth, flat, horizontal ceilings with the deflectors located 6" to 12" (152 mm to 305 mm) below the ceiling. Maximum Areas of Coverage 6 Minimum Water Supply Requirements 6 Listings 4 UL C-UL 7 NYC Width x Length 12' x 12' (3,7 m x 3,7 m) 21 gpm @ 14.6 psi (79,5 L/min @ 100,5 kpa) A1X A1X 14' x 14' (4,3 m x 4,3 m) 22 gpm @ 16 psi (83,3 L/min @ 110,3 kpa) A1X A1X 16' x 16' (4,9 m x 4,9 m) 24 gpm @ 19 psi (90,8 L/min @ 131,3 kpa) A1X A1X 16' x 18' (4,9 m x 5,5 m) 27 gpm @ 24.1 psi (102,2 L/min @ 166,2 kpa) A1X A1X Installed below sloped ceilings up to and including an 8/12 (33.7 ) pitch 5. Sprinklers must be installed at the peak with spray directed down the slope 6 with deflectors located 4 to 6" (102 mm to 152 mm) below the ceiling. Refer to Figure 4 below. Maximum Areas of Coverage 5,6 Minimum Water Supply Requirements 6 Listings 4 UL C-UL 7 NYC Width x Length 12' x 12' (3,7 m x 3,7 m) 21 gpm @ 14.6 psi (79,5 L/min @ 100,5 kpa) A1X A1X 14' x 14' (4,3 m x 4,3 m) 22 gpm @ 16 psi (83,3 L/min @ 110,3 kpa) A1X A1X 16' x 16' (4,9 m x 4,9 m) 24 gpm @ 19 psi (90,8 L/min @ 131,3 kpa) A1X A1X 16' x 18' (4,9 m x 5,5 m) 28 gpm @ 25.9 psi (106 L/min @ 178,7 kpa) A1X A1X Approved Temperature Ratings A - 155 F (68 C) and 175 F (79 C) Approved Finishes 1 - Brass, Bright Brass, Chrome-Enloy, White, and Navajo White Temperature Finish Escutcheon (if applicable) Approved Escutcheons X - Standard surface-mounted escutcheons or the Microfast Model F-1 Adjustable Escutcheon 8, or recessed with the Micromatic Model E-1 or E-2 Recessed Escutcheon Footnotes 1 Metric K-Factor shown is for use when pressure is measured in kpa. When pressure is measured in BAR, multiply the metric K-Factor shown by 10.0. 2 Base part number shown. For complete part number, refer to Viking's current price list. 3 Sprinkler identification number provided in accordance with the 1999 edition of NFPA 13, Section 3-2.2. 4 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed area of coverage measured along ceiling. Consult Figure 4 below and "Residential Installation Guide" paragraphs that pertain to sprinklers with listings for both smooth, flat, horizontal ceilings and sloped ceilings for installation details. 6 For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" for the next larger listed area of coverage with sprinklers of similar K-Factor. Flow and pressures listed are per sprinkler. 7 Listed by Underwriter's Laboratories, Inc. for use in Canada 8 The Microfast Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. NOTE: Horizontal sidewall sprinklers must be installed with deflectors located between 4" and 6" (102 mm and 152 mm) from walls. Exception: Horizontal sidewall sprinklers may be located less than 4" (102 mm) from the wall in which they are installed. Always install horizontal sidewall sprinklers with the top of the deflectors aligned parallel with the ceiling or roof. Microfast Residential HSW Sprinkler SIN VK442 installed with the Viking Micromatic Model E-1 or E-2 Recessed Escutcheon For sloped ceiling installations, the top of deflector must be located 4 to 6" from the ceiling. Always 33.7 max. align the top of the horizontal sidewall deflector parallel with the ceiling. Maximum height from deflector to the finished floor = 18-0". Figure 4: Installation Guidelines for sprinklers installed below a sloped ceiling. Sprinkler must be installed at the peak with spray directed down the slope. (Applies for all SIN VK442 Sprinklers manufactured after July 12, 2002 to be installed in new residential sprinkler systems, and SIN VK442 Sprinklers manufactured after July 12, 2002 to be installed in existing residential sprinkler systems where water supplies are adequate to provide a minimum density of.05 gpm/sq. ft. over the design area.) A1X KEY NOTES: 1. A single sprinkler installation has been shown for clarity. Actual installations may require multiple sprinklers. 2. This figure shows an installation of a sprinkler at the peak of a sloped ceiling, with slopes up to and including an 8/12 (33.7 ) pitch. Spray may NOT be directed across the slope. 3. When installing Sprinkler SIN VK442 below a sloped ceiling, the sprinkler deflector must be located 4 to 6" (102 mm to 152 mm) below the ceiling. 4. Maximum height from finished floor to sprinkler deflector is 18-0". 5. Maximum width of compartment regardless of sprinkler area of coverage is 32-0". Maximum compartment sizes are based on sprinkler listings. (i.e., 12 x 32, 14 x 32, etc.) 6. Listed areas of coverage are measured along the ceiling (for sloped ceiling installations, actual floor coverage will be less than the listed area). 7. A maximum of two sprinklers are required to be hydraulically calculated per compartment.

Sprinkler 42 f Thread Size Nominal K-Factor Overall Length Sprinkler Base Sprinkler Identification Deflector Style Inch mm U.S. metric 1 Inches mm Part Number 2 Number (SIN) 3 Horizontal Sidewall ½ 15 5.5 7,9 2-11/16 68,3 09533 VK442 Approval Chart 3 For Residential Applications Only Microfast Horizontal Sidewall Sprinkler Listings on this page apply when Sprinkler SIN VK442 is installed as a replacement sprinkler in existing residential sprinkler systems designed and installed to provide a minimum density of.04 gpm/sq. ft. over the design area, and for new residential sprinkler systems only when using SIN VK442 Sprinklers manufactured before July 12, 2002. When using SIN VK442 Sprinklers manufactured after July 12, 2002 to be installed in new residential sprinkler systems, or SIN VK442 Sprinklers manufactured after July 12, 2002 to be installed in existing residential sprinkler systems where water supplies are adequate to provide a minimum density of.05 gpm/sq. ft. over the design area, refer to page 42 e. Max. Areas of Coverage 5,6 Minimum Water Supply Requirements 6 Listings 4 Width x Length Single Sprinkler Two or More Sprinklers UL C-UL 7 NYC 8 Installed with deflectors located 6" to 10" (152 mm to 254 mm) below smooth, flat, horizontal ceilings. Or, installed 4 to 6" (102 mm to 152 mm) below sloped ceilings up to and including a 6/12 (26.6 ) pitch 5 with sprinklers at peak spraying down the slope. Refer to Figure 5 on page 42 g. 12' x 12' (3,7 m x 3,7 m) 21 gpm @ 14.6 psi (79,5 L/min @ 100,5 kpa) 15 gpm @ 7.4 psi (56,8 L/min @ 51,3 kpa) A1X A1X A1X 14' x 14' (4,3 m x 4,3 m) 22 gpm @ 16 psi (83,3 L/min @ 110,3 kpa) 17 gpm @ 9.6 psi (64,4 L/min @ 65,9 kpa) A1X A1X A1X 16' x 16' (4,9 m x 4,9 m) 24 gpm @ 19 psi (90,8 L/min @ 131,3 kpa) 21 gpm @ 14.6 psi (79,5 L/min @ 100,5 kpa) A1X A1X A1X 16' x 18' (4,9 m x 5,5 m) 27 gpm @ 24.1 psi (102,2 L/min @ 166,2 kpa) 22 gpm @ 16 psi (83,3 L/min @ 110,3 kpa) A1X A1X A1X 16' x 20' (4,9 m x 6,1 m) 32 gpm @ 33.9 psi (121,1 L/min @ 233,4 kpa) 30 gpm @ 29.8 psi (113,6 L/min @ 205,1 kpa) A1X A1X A1X Installed with deflectors located 6" to 10" (152 mm to 254 mm) below sloped ceilings up to and including a 6/12 (26.6 ) pitch 5 with sprinklers at side spraying across the slope. Refer to Figure 6 on page 42 g. Max. Areas of Coverage 5,6 Minimum Water Supply Requirements Width x Length 6 Listings 4 UL C-UL 7 NYC 8 12' x 12' (3,7 m x 3,7 m) 21 gpm @ 14.6 psi (79,5 L/min @ 100,5 kpa) 15 gpm @ 7.4 psi (56,8 L/min @ 51 kpa) A1X A1X A1X 16' x 16' (4,9 m x 4,9 m) 24 gpm @ 19 psi (90,8 L/min @ 131,3 kpa) 21 gpm @ 14.6 psi (79,5 L/min @ 100,5 kpa) A1X A1X A1X Approved Temperature Ratings Approved Finishes 1 - Brass, Bright Brass, Chrome-Enloy A - 155 F (68 C) and 175 F (79 C), White, and Navajo White Temperature Finish Escutcheon (if applicable) Approved Escutcheons X - Standard surface-mounted escutcheons or the Microfast Model F-1 Adjustable Escutcheon 9, or recessed with the Micromatic Model E-1 or E-2 Recessed Escutcheon Footnotes 1 Metric K-Factor shown is for use when pressure is measured in kpa. When pressure is measured in BAR, multiply the metric K-Factor shown by 10.0. 2 Base part number shown. For complete part number, refer to Viking's current price list. 3 Sprinkler identification number provided in accordance with the 1999 edition of NFPA 13, Section 3-2.2. 4 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed area of coverage measured along ceiling. Consult Figures 5 and 6 on page 42 g and "Residential Installation Guide" paragraphs that pertain to sprinklers with listings for both smooth, flat, horizontal ceilings and sloped ceilings for installation details. 6 For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" for the next larger listed area of coverage with sprinklers of similar K-Factor. Flow and pressures listed are per sprinkler. 7 Listed by Underwriter's Laboratories, Inc. for use in Canada. 8 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Volume XV. 9 The Microfast Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. NOTE: Horizontal sidewall sprinklers must be installed with deflectors located between 4" and 6" (102 mm and 152 mm) from walls. Exception: Horizontal sidewall sprinklers may be located less than 4" (102 mm) from the wall in which they are installed. Always install horizontal sidewall sprinklers with the top of the deflectors aligned parallel with the ceiling or roof. A1X KEY

Sprinkler 42 g Microfast Residential Horizontal Sidewall Sprinkler SIN VK442 installed with the Viking Micromatic Model E-1 or E-2 Recessed Escutcheon Figure 5: Installation Guidelines--for Residential Applications Only. Sprinklers installed at the peak of a sloped ceiling with spray directed down the slope. (Applies for all SIN VK442 Sprinklers installed as replacement sprinklers in existing residential systems designed using sprinklers manufactured prior to July 12, 2002, and for new residential systems only when using SIN VK442 Sprinklers manufactured before July 12, Maximum ceiling slope = 6/12 (26.6 ). See Note 2 below. Top of deflector must be located 6" to 10" (152 mm to 254 mm) below the ceiling. Keep the top of the deflector parallel with the ceiling. 26.6 max. Maximum Throw 16-0" Top of deflector must be located 4 to 6" from the ceiling. Always align top of horizontal sidewall deflector parallel with ceiling. Maximum height from deflector to the finished floor = 18-0". NOTES: 1. A single sprinkler installation has been shown for clarity. Actual installations may require multiple sprinklers. 2. This figure shows an installation of a sprinkler at the peak of a sloped ceiling. Installations in this configuration are limited to a 6/12 (26.6 ) slope. 3. When installing a sprinkler at the peak of ceiling, the sprinkler deflector must be located 4 to 6" (102 mm to 152 mm) below the ceiling. 4. Maximum height from finished floor to sprinkler deflector is 18-0". 5. Maximum width of compartment regardless of sprinkler area of coverage is 32-0". Maximum compartment sizes are based on sprinkler listings. (i.e., 12 x 32, 14 x 32, etc.) 6. Listed areas of coverage are measured along the ceiling (for sloped ceiling installations, actual floor coverage will be less than the listed area). 7. A maximum of two sprinklers are required to be hydraulically calculated per compartment. Listed areas of coverage correspond to ceiling slope. (For sloped ceiling installations, actual floor coverage will be less than the listed area.) Maximum 8-0" (2,4 m) high opening allowed in perimeter walls. NOTES: 1. A single sprinkler installation has been shown for clarity. Actual installations may require multiple sprinklers. For multiple sprinkler installations, sprinklers may be installed on opposite walls, throwing toward each other. 2. This figure shows an installation of a sprinkler on the side of a sloped ceiling. Installations in this configuration are limited to a 6/12 (26.6 ) slope. 3. For cathedral ceiling applications, install sprinklers in a symmetrical mirror-image of Figure 6. 4. Maximum allowable compartment sizes are as follows (area measured along slope): One sprinkler, single wall: 16 Width x 16 Throw (calculate one sprinkler). One sprinkler each, opposite walls: 16 Width x 32 Throw (calculate two sprinklers). Two sprinklers, single wall: 32 Width x 16 Throw (calculate two sprinklers). Two sprinklers each, opposite walls: 32 Width x 32 Throw (calculate two sprinklers). Three sprinklers, single wall: 48 Width x 16 Throw (calculate three sprinklers). Three sprinklers each, opposite walls: 48 Width x 32 Throw (calculate three sprinklers). 5. Maximum allowable number of sprinklers per compartment is six. 6. Sprinklers may be installed in any combination of acceptable installation locations, as long as each sprinkler is located in accordance with its individual listings. Figure 6: Installation Guidelines--for Residential Sprinklers Only. Sprinklers installed on the side of a sloped ceiling with spray directed across the slope. (Applies for all SIN VK442 Sprinklers installed as replacement sprinklers in existing residential systems designed using sprinklers manufactured prior to July 12, 2002, and for new residential systems only when using SIN VK442 Sprinklers manufactured before July 12, 2002.)

Replaces page 42 a-d, dated October 1, 2000. Also refer to the appropriate Viking general care, installation, and maintenance guide for the particular application type. Form No. F_022697