***Equipment Cut Sheets***

Similar documents
SUBMITTAL SCHEDULE & DATA

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Indirect Gas-Fired Make-Up Air

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Direct Fired Heater Model AD Specification

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

bring value to your space

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

Submittal Data Performance Data Electrical Data

ENVIRONMENTAL EQUIPMENT Poly-Vent

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Gas-Fired Unit Heaters Commercial & Industrial

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

Gas-Fired Unit Heaters Commercial & Industrial

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

FX5 Series Explosion-Proof Electric Air Heaters

Direct Gas-Fired Make-Up Air

13 GEP A L P - 1 A

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

SECTION AIR DOORS

GA Gas Unit Heater Assemblies Technical Guide

Modular Heating & Ventilating Unit Model IGX-HV

SKYPAK II, 3 Ton Series, gives you a

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Gas-Fired Indoor and Outdoor Duct Furnaces

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Brasch Hazardous Location Unit Heaters

HVAC HEATING PRODUCTS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

INFRARED RADIANT HEATERS

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Industrial Air Heaters

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SKYPAK II, 3 Ton Series, gives you a

Cabinet Unit Heaters Steam / Hot Water

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

A. Product Data: Include rated capacities, furnished specialties and accessories.

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Modular Supply Make-Up Air Unit

RGE 13 A T - 1 A

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

AFUE 95% Heating Input 50,000 to 200,000 Btuh

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Thermal Devices, Inc. Mount Airy, Maryland USA

SECTION AIR HANDLING UNIT

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

SECTION AIR DUCT ACCESSORIES

2002 METAL FORM MFG. Form No: CCIOM/03

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Click Here To View Item at

CWA4 Chilled & Hot Water Fan Coil

SECTION STEAM CONDENSATE PUMPS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

A. Codes and Standards that are Standard at the University:

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Service Parts, Kits and Accessories

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Product Specifications. Vertical Floor Consoles By First Co.

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

Selecting the Correct Fan

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

FEATURES AND BENEFITS

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

JCseries EVAPORATIVE CONDENSER. engineering data

RG7D 1-Stage Heat Series

Transcription:

STEM 2 Greenhouse Project Bid No. B17-14 ***Equipment Cut Sheets*** Bid RFI Questions Due: Tuesday, July 11, 2017 2:00PM Gale Stevens, Buyer gasteven@cabrillo.edu BID DOCUMENTS: GALE STEVENS, BUYER 831-477-5613 PROJECT MANAGER: JON SALISBURY, ICS, INNOVATIVE CONSTRUCTION SERVICES ARCHITECT: KASAVAN ARCHITECTS

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-04 Submittal Description: 8mm clear twin wall acrylic Manufacturer: Evonik Quantity: ea Product Data Information:

Technical information 8 mm ACRYLITE Resist high impact acrylic double-skin sheet 1,200 mm + 2 mm /-3 mm (47.25 +.08 /-.118 ) No Drip one exterior surface 8 mm ± 0.5 mm (0.315 ± 0.02 ) ~14.5 mm (~0.571 ) ~16 mm (~0.63 ) ~16 mm (~0.63 ) 8 mm ACRYLITE Resist high impact acrylic double-skin sheet is a light transmitting, heat-insulating and weatherresistant sheet made of impact-modified acrylic (polymethyl methacrylate, PMMA) polymer. 8 mm ACRYLITE Resist high impact acrylic double-skin is suitable for sloped, curved and vertical applications including the following: Canopies Clerestory Glazing Interior Walls Interior Partitions Lighting Panels Skylights Barrel Vaults Facades & Cladding Greenhouses Pool Enclosures Advantages of 8 mm ACRYLITE Resist high impact acrylic double-skin sheet Extraordinary clear sheet is UV-resistant and includes a 30-year warranty against yellowing. Impact resistance during transportation, handling and installation. Up to 40% energy savings and minimizes CO 2 emissions. Hail-resistant with a 10-year warranty for withstanding hailstones with a kinetic energy of 1 joule. High light transmission in the PAR and visible spectral energy wavelengths. Available in clear and translucent white. Warranties Non-prorated, full replacement 30 year non-yellowing, 10 year light transmission and 10 year hail warranties. For details see warranty. Environmental Sustainability ACRYLITE Resist high impact acrylic double-skin sheets natural heat insulating qualities can translate into significant energy savings, making them an ideal choice for eco-lighting and building green. The sheets are built to last using environmentally sound manufacturing processes in facilities that have received ISO-14001 environmental certification. In addition, if the time does come for replacement, ACRYLITE can be recycled in an environmentally friendly manner. Evonik Cyro Canada Inc. 8 mm ACRYLITE Resist high impact acrylic double-skin sheet January 2013 Page 1/3

Technical Data (Typical values) Light Transmittance D65 Total Energy Transmission Values Shading Coefficient (SC) Clear (00721) 84% 82% 0.94 Light White (W1621) 62% 79% 0.83 UV Transmission U-value blocking 3.4 W/m 2 K (0.56 BTU/hr ft 2 ºF) R-value 1.78 ºF/BTU hr ft 2 Coefficient of Heat Expansion (α) 0.09 mm/m ºC (0.00005 in/in/ºf ) Expansion Due to Heat & Moisture 6 mm/m (1/16 /ft) Approximate Area Weight 3.3 Kgm 2 (0.7 lbs/ft 2 ) Thickness Rib Spacing Width Length Weighted Sound Reduction Index Maximum Service Temperature ASTM D-635 (Rate of Burn) 8 mm (⁵ ₁₆ ) 16 mm (⁵ ₈ ) 1200 mm (47 ¼ ) up to 10973 mm (36 ft) 23 db 70 C (160 ºF) C2 / CC2 Cold Bending Radius ASTM D-1929 (Self Ignition Temp) 830 ºF ASTM D-2843 (Smoke Density Rating) 8.1 % CAN/ULC S102.2 DIN 4102 < 150 Flame Spread Classification normal combustability, B2 Minimum permissible cold-forming radius of 48 (150 x thickness) Values are approximate. No Drip The water-dispersing, patented No Drip coating applied on one side of the sheet causes any surface water to form a thin, continuous film. When the sheet is installed with the No Drip coating on the outside of the roof, the coating can support the natural cleaning of the roof by rainwater. When the coating is on the inside, it contributes toward preventing any condensed water from forming drops and thus averts the damage caused by condensation. Fire Behaviour The fire behavior of ACRYLITE is rated as C2 or CC2 according to ASTM D-635. ACRYLITE burns almost entirely without smoke according to DIN4102 and ASTMD-2843 and is easily extinguished. The smoke gases produced by ACRYLITE are neither accutely toxic according to DIN 53436, nor corrosive according to DIN VDE 0482-267. Load Bearing Capacity Due to its excellent rigidity, large areas can be glazed quickly and efficiently. Few intermediate supports are required to carry substantial uniformly distributed loads (refer to Support Spacing chart). Reduction of structural members means less shading thus increasing light levels. Evonik Cyro Canada Inc. 8 mm ACRYLITE Resist high impact acrylic double-skin sheet January 2013 Page 2/3

Support Spacing As flat glazing supported on all sides, 1200 mm wide 8 mm double-skin sheet requires crosswise supports spaced at 106 (2.7 m) for uniformly distributed loads up to 15.7 lb/ft 2 (750 N/m 2 ). For greater loads, the recommended spacing is given in the support spacing chart. Maximum allowable spacing is in the direction parallel to the sheet s ribs. Refer to local building codes to determine the applicability of these values to specific applications. Building codes will indicate the design loads to be used to determine the maximum span lengths or support spacing. Support Spacing Chart 8 mm ACRYLITE Resist high impact acrylic double-skin sheet width as delivered 1200 mm (47 ¹ ₄ ) Load Support Spacing [N/m 2 ] (lb/ft 2 ) [m] (in) 750 15.7 2.7 106 1000 20.9 2.2 86 1250 26.1 1.9 74 1500 31.3 1.7 66 1750 35.5 1.6 63 2000 41.8 1.5 59 ACRYLITE is a registered trademark of Evonik Cyro LLC in the Americas. These same products are manufactured and marketed under the PLEXIGLAS trade name on the European, Asian, African and Australian continents. Certified to DIN EN ISO 9001 (Quality) and DIN EN ISO 14001 (Environment). Important Notice: This information and all technical and other advice are based on Evonik s present knowledge and experience. However, Evonik assumes no liability for such information or advice, including the extent to which such information or advice may relate to third party intellectual property rights. Evonik reserves the right to make any changes to information or advice at any time, without prior or subsequent notice. EVONIK DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, WHETHER EXPRESS OR IMPLIED, AND SHALL HAVE NO LIABILITY FOR, MERCHANTABILITY OF THE PRODUCT OR ITS FITNESS FOR A PARTICULAR PURPOSE (EVEN IF EVONIK IS AWARE OF SUCH PURPOSE), OR OTHERWISE. EVONIK SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES (INCLUDING LOSS OF PROFITS) OF ANY KIND. It is the customer s sole responsibility to arrange for inspection and testing of all products by qualified experts. Reference to trade names used by other companies is neither a recommendation nor an endorsement of the corresponding product, and does not imply that similar products could not be used. January 2013 Evonik Cyro LLC 299 Jefferson Road Parsippany, NJ 07054 USA phone +1 800 631-5384 www.acrylite.net www.evonik.com Evonik Cyro Canada Inc. 180 Attwell Drive, Suite 101 Toronto, Ontario M9W 6A9 Canada phone +1 888 233-4527 www.acrylitebuildingproducts.com

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 Date: 2/27/2017 fax: (303) 457-2801 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-05 Submittal Description: Evaporative Pad System Manufacturer: American Coolair Quantity: 1 ea Product Data Information: 3' x 45' x 6" PVC evaporative pad system

EVAPORATIVE COOLING IN CONCEPT To counter periods of extreme temperature that affect in-house environments and therefore production, Coolair Evaporative Cooling Pad Systems are used with outstanding success. When large quantities of air are pulled through Evaporative Cooling Pads that are saturated with water, a substantial cooling effect is realized due to the evaporation of that water. Used in conjunction with Coolair fans, a temperature reduction of 10-25 degrees is commonplace. Suited for virtually all geographic locations, the Coolair Evaporative Cooling System delivers the greatest economic benefits to areas where higher temperatures during longer periods of time are normal. WHAT IS AN EVAPORATIVE COOLING PAD? Evaporative Cooling Pads (Evap Pads) are a product developed for horticultural and agricultural cooling applications. Evap Pads are made of a specially formulated cellulose paper, impregnated with insoluble anti-rot salts, stiffening saturants and wetting agents. Evap Pads have a cross fluted configuration that provides maximum cooling when warm air passes through the wet Evap Pad material. FEATURES OF EVAPORATIVE COOLING PADS Evap Pads will not sag, rot or develop holes. With proper care and maintenance, Evap Pads will last for 5 years or more. There is no carry-over of water droplets to enter the house. The neat appearance of Evap Pads compliments modern buildings. COMPATIBLE BUILDING DESIGN Optimum results would, of course, be obtained through the use of a house built specifically for a Coolair Evap Pad System installation. As this is not always a feasible approach, the Evap Pad System is also designed to be compatible with any modern, air-tight, insulated house. SUGGESTED LAYOUT DESIGN For greenhouse applications, the Coolair Evap Pad A B C D will be the most productive when the system is centered on the plants to be cooled. Specific placement should be such that the upper portion of the pad itself is on the same level as the top of the crop to be cooled. For poultry or livestock houses, preferable pad location is in the end of the building opposite that of the fan installations. The air should be drawn the length of the building except in cases where the resulting air velocity surpasses the comfort levels of the poultry or animals confined. In these instances, pad placement is recommended on both ends of the house while fan installation should be set for both sides of the middle. A third consideration for placement of pads is the same side as the summer prevailing winds with fan installation on the opposed side.

THE EVAPORATIVE COOLING PAD Evap Pads are 4 or 6 thick, 12 wide with height increments every 12 from 24 to 96. The Evap Pads are positioned adjacent to each other to form a continuous pad of the required height and length. The Evap Pads are made of specially formulated cellulose paper, impregnated with insoluble anti-rot salts, stiffening saturants and wetting agents. 4 Evap Pads up to 48 tall and 6 Evap Pads up to 72 tall are self-supporting, and therefore they do not require wire baskets or other supporting materials. The pads are held in place by component parts of the system. Tall pad supports are required on 4 pad systems over 48 tall and 6 pad systems over 72 tall. In addition to the standard Evap Pad, Edge-coated pads, which help reduce algae growth or build-up, are also offered. Standard Pad Edge-Coated Pad PVC SYSTEM ALUMINUM SYSTEM System length 5 to 60 - System height 2 to 8 Completely self-contained Sump included Multiple pump designs available. For longer systems, consult your American Coolair representative THE PUMP AND SUMP The least pumps are sized for the system to supply at 1 /2 pad system. gallon The of integral water per PVC minute sump per and linear trough foot hold of an adequate water supply for systems up to 60 long and 8 high. WATER DISTRIBUTION SYSTEMS System length 5 to 100 - System height 2 to 8 Ideal when large amounts of cooling is needed Multiple pump designs available. For longer systems, consult your American Coolair representative THE PUMP AND SUMP The least pumps are sized for the system to supply at 1 /2 pad system. gallon The of water sump per should minute be purchased per linear foot locally of and be sized for at least 3 /4gallon capacity per square foot of pad area. The pipe water with metered distribution outlet systems holes, for top both and PVC bottom and pad Aluminum support designs material, are water composed distribution of the pipe water cover, distribution water return PVC trough, water filter, float and volume control valves and various parts and fasteners. EVAPORATIVE COOLING PAD AREA REQUIREMENTS For system designs to suit the specific needs for your type of building and atmospheric conditions, you may wish to consult your American Coolair representative. However, as a general guide, you can use the following system recommendations to insure proper cooling in your building: For 4" pad systems: Use sq. ft. of pad per 250 CFM. For 6" pad systems: Use 1 sq. ft. of pad per 400 CFM. Example: A building has 6 fans that produce 20,000 CFM each for a total flow of 120,000 CFM through the building. 4 system 120,000 250 480 sq. ft. of pad required 6 system 120,000 400 = 300 sq. ft. of pad required

PVC EVAPORATIVE COOLING SYSTEM (SHOWN WITH A SUBMERSIBLE PUMP) 1-1/2" PVC ELBOW 1-1/2" PVC ELBOW BALL VALVE (VOLUME CONTROL) 3/4" HOSE BIBB FOR WATER BLEED OFF FILTER 1-1/2" COMPRESSION COUPLING FLOAT VALVE SUMP PUMP THREADED ADAPTER WATER LEVEL BALL VALVE (FLUSH) ALUMINUM EVAPORATIVE COOLING SYSTEM (SHOWN WITH A CENTRIFUGAL PUMP) 1-1/2" PVC PIPE CUT TO LENGTH (TYPICAL) 1-1/2 PVC ELBOW 1-1/2" PVC TEE PAD 1-1/2" x 1-1/2" x 3/4" PVC TEE BALL VALVE (VOLUME CONTROL) TROUGH WATER OUTLET RETURN PIPE SCREEN OVERFLOW PIPE AND DRAIN* 1-1/2" PVC ELBOW PUMP FLOAT 1-1/2 PVC PIPE 2 MIN. 3/4" HOSE BIBB FOR WATER BLEED OFF FILTER 1-1/2" MALE THREAD TO 1-1/2" SLIP 2" MALE THREAD TO 1-1/2" SLIP SUMP TANK* 1-1/2 PVC ELBOW WATER VALVE CHECK VALVE *NOT SUPPLIED BY COOLAIR!! " # "! $!! %! $ & ' $ "! " ( & ( % % %! ( " % ) "! ( $ ' $ % *! ' & "! % & "!!! $ + (! (, ( " ( # $ -! %. & " "! % / 0 1 2 * / 1 ) 3.. 4 / 5 6 / / 1 ) 0 1. 1 4 6 4 2 1 7 8 9 2 2 8 / 0 1. 3.. 4 / 1 6 ( 1 : ;. 1 6 6 ( 6 / / 7 / 8. 5 8. * ; 2 1 ) ( 4 2 7 ) 4 < 3 / 0 8 7 / 2 * / / 8 4 / 0 / 8 9 * 1. 0 4 / = 2 / 5 4 ) 9 / 4 1 6 6 % 4!! ( -! % >? @ A B C > D C E E F > B A C E A G E A > H B E D G I E I J K L M N O O P Q R S T K U V W X XY Z [ F N M M O N G \ K U Y ] ^ O _ ` N a ^ b N c _ c [ Q L ] ^ O _ ` N a d b N ^ @ b? Q W X e f Q U T g R K K XQ W h I R K i j Y k T Wl Y e m m m I R K K XQ W h I R K i FORM 940-12-6 (February, 2001)

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 Date: 2/27/2017 fax: (303) 457-2801 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-06 Submittal Description: Evaporative Pad System Pump Manufacturer: American Coolair Quantity: 1 ea Product Data Information: 115 v 1/6 hp 5 amps

Industrial 5-MSP Series Applications For commercial, industrial, and home applications where water must be transferred or recirculated Features 1/6 hp oil-filled motor Epoxy-coated die cast aluminum housing 1" FNPT discharge Screened intake Intermittent liquid temperate up to 120 F Thermal overload protection 26.3' maximum lift For submersible use only Construction Housing Epoxy-coated cast aluminum Cover Epoxy-coated cast aluminum Volute Nylon Impeller Nylon Shaft Seal Fluoroelastmer (FKM) Screen Nylon Wastewater Water Systems HVAC Industrial Engineered Products

Engineering Data Specifications Performance (GPH @ Head) Shut Off Cord Item No. Model No. Listing(s) HP Volts Hz Amps Watts Discharge 1' 3' 5' 10' 20' Ft PSI Length (ft) Weight (lbs) Dimensions H X L X W (in) 505000 5-MSP ccsaus 1/6 115 60 5.0 380 1" FNPT 1200 1170 1100 1000 520 26.3 11.4 10 8.25 7.8" x 6.1" x 4.3" 505176 5-MSP ccsaus 1/6 115 60 5.0 380 1" FNPT 1200 1170 1100 1000 520 26.3 11.4 18 8.50 7.8" x 6.1" x 4.3" 505025 5-MSP ccsaus 1/6 115 60 5.0 380 1" FNPT 1200 1170 1100 1000 520 26.3 11.4 25 8.75 7.8" x 6.1" x 4.3" 505500 5-MSP 1/6 127 60 5.8 380 1" FNPT 1200 1170 1100 1000 520 26.3 11.4 10 8.25 7.8" x 6.1" x 4.3" 505501 5-MSP 1/6 127 60 5.8 380 1" FNPT 1200 1170 1100 1000 520 26.3 11.4 18 8.50 7.8" x 6.1" x 4.3" 505202 5-MSP 1/6 230 60 2.5 380 1" FNPT 1200 1170 1100 1000 520 26.3 11.4 12 8.25 7.8" x 6.1" x 4.3" Replacement Parts Volute 105375 Screen 105376 Impeller 105310 Handle 105918 Adapter (GH) 599030 Seal Ring (volute) 928024 Head - Feet Performance Data Flow - Liters/Hour Head - Meters Flow - Gallons/Hour P.O. Box 12010 Oklahoma City, OK 73157-2010 Phone: 1.800.701.7894 Fax: 1.800.678.7867 www.littlegiantpump.com Form 995117 01/13

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 Date: 2/27/2017 fax: (303) 457-2801 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-07 Submittal Description: Intkae Shuters Manufacturer: American Coolair Quantity: 9 ea Product Data Information: LRW6036E 115 v.28 amps

Sheet of Type LRW-E Motorized Inlet Shutter Standard Features Aluminum blades Extruded aluminum frame Aluminum blade brackets and tie bars Blades pivot on nylon bushings Heavy duty gear motor and chain linkage Shutter Model Air Flow Capacity (CFM) Dimensions in Inches A B* C D* Approx. Ship. Wt. Lbs. LRW16E 1,000 19 1 / 4 16 19 1 / 4 16 8 P.O. Box 2300 Jacksonville, Florida 32203 Phone: (904) 389-3646 Fax: (904) 387-3449 (904) 381-7560 E-mail: agfans@coolair.com Internet: www.coolair.com LRW21E 1,800 24 1 / 4 21 24 1 / 4 21 10 LRW27E 3,000 30 1 / 4 27 30 1 / 4 27 12 LRW33E 4,500 36 1 / 4 33 36 1 / 4 33 14 LRW39E 6,300 42 1 / 4 39 42 1 / 4 39 17 LRW45E 8,400 48 1 / 4 45 48 1 / 4 45 20 LRW51E 10,700 54 1 / 4 51 54 1 / 4 51 24 A LRW57E 13,400 60 1 / 4 57 60 1 / 4 57 30 3 / 8 B 2 1 / 2 LRW66E 18,000 69 1 / 4 66 69 1 / 4 66 36 LRW4515E 2,800 48 1 / 4 45 18 1 / 4 15 10 LRW4527E 5,000 48 1 / 4 45 30 1 / 4 27 15 LRW6015E 3,700 63 1 / 4 60 18 1 / 4 15 15 LRW6024E 6,000 63 1 / 4 60 27 1 / 4 24 18 LRW6036E 8,900 63 1 / 4 60 39 1 / 4 36 22 * - Add 1/2 to B and D to get required wall opening dimensions. C D Dimensions Dimension A is overall shutter width including flanges on the sides. Width of the flange is 1 5 / 8. 2 13 / 16 Dimension B is the shutter frame width without flanges. Dimension C is the overall shutter height including flanges on the top and bottom. Width of the flange is 1 5 / 8. Dimension D is the shutter frame height without flanges. 5 / 16 x 1 / 2 slots 2 13 / 16 3 3 / 4 3 3 / 4 Dimensions in inches Form No. 910-42-2 (10-10) Printed in U.S.A. by American Coolair Corporation 2010

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-08 Submittal Description: Exhaust Fans Manufacturer: American Coolair Quantity: 2 ea Product Data Information: AL36K one speed 3/4 HP 9 amps

AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion in today s damp greenhouse environment. Combined with an aluminum wall housing, an aluminum shutter, and a vinyl coated wire guard, the AL fan will provide years of trouble-free and corrosion-free service. AL fans feature all-welded angle frame construction for a rugged and durable unit. The fan panel has a deep spun orifice for maximum efficiency. AL fans utilize Coolair s exclusive drive assembly used on our fans for over 80 years. The die-formed aluminum blades are bolted to a cast aluminum hub, which also serves as the fan pulley. Power is applied through V-belts directly to the propeller with the blade load concentrated directly over the fan bearings, thus eliminating overhung bearing load. AL fans are available with single- or two-speed totally enclosed motors. PERFORMANCE RATINGS Fan Fan Motor Fan AMERICAN COOLAIR CORPORATION certifies that the performance data for the type AL wall fan models shown below are based on tests conducted in an accredited laboratory in accordance with ANSI/AMCA Standard 210-07. CUBIC FEET PER MINUTE (CFM) AT STATIC PRESSURE 0" S.P..05" S.P..10" S.P..125" S.P..15" S.P. Model Size HP RPM CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP AL24G 1/4 688 5,293 0.24 5,026 0.25 4,724 0.26 4,553 0.27 4,362 0.28 AL24H 24 1/3 769 5,916 0.33 5,680 0.35 5,421 0.36 5,279 0.37 5,128 0.38 AL24J 1/2 891 6,855 0.51 6,654 0.53 6,438 0.55 6,324 0.56 6,205 0.57 AL24K 3/4 1042 8,017 0.83 7,846 0.84 7,574 0.86 7,574 0.87 7,478 0.88 AL30G 1/4 491 7,205 0.24 6,625 0.25 5,997 0.27 5,648 0.27 5,239 0.28 AL30H 30 1/3 531 7,792 0.29 7,258 0.32 6,690 0.33 6,386 0.34 6,056 0.34 AL30J 1/2 641 9,406 0.52 8,968 0.54 8,512 0.56 8,276 0.57 8,034 0.58 AL30K 3/4 739 10,845 0.80 10,466 0.83 10,076 0.85 9,877 0.86 9,674 0.87 AL36H 1/3 447 9,735 0.29 9,007 0.32 8,241 0.34 7,773 0.36 7,103 0.38 AL36J 36 1/2 524 11,411 0.47 10,793 0.51 10,160 0.54 9,832 0.55 9,477 0.56 AL36K 3/4 615 13,393 0.75 12,868 0.80 12,334 0.84 12,063 0.86 11,790 0.87 AL36L 1 692 15,070 1.07 14,604 1.12 14,132 1.18 13,894 1.20 13,654 1.22 AL42H 1/3 322 12,106 0.30 10,921 0.33 9,919 0.36 8,430 0.37 7,149 0.39 AL42J 42 1/2 371 13,948 0.46 12,986 0.49 11,525 0.53 10,797 0.54 10,159 0.56 AL42K 3/4 430 16,166 0.71 15,372 0.75 14,318 0.79 13,625 0.81 12,938 0.83 AL42L 1 492 18,497 1.07 17,821 1.11 17,009 1.15 16,513 1.18 15,932 1.20 AL48J 1/2 307 16,740 0.49 15,278 0.52 13,371 0.54 12,370 0.54 11,062 0.56 AL48K 48 3/4 358 19,521 0.77 18,315 0.82 16,814 0.84 15,964 0.85 15,121 0.85 AL48L 1 408 22,248 1.14 21,212 1.19 20,001 1.23 19,305 1.24 18,565 1.25 AL54L 54 1 374 23,911 1.06 22,693 1.11 21,283 1.16 20,480 1.18 19,618 1.20 AL54M 1 1/2 414 26,496 1.44 25,381 1.50 24,165 1.55 23,491 1.58 22,766 1.60 4

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-09 Submittal Description: Exhaust Fans Manufacturer: American Coolair Quantity: 2 ea Product Data Information: AL36K two speed 3/4 HP 14 amps

AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion in today s damp greenhouse environment. Combined with an aluminum wall housing, an aluminum shutter, and a vinyl coated wire guard, the AL fan will provide years of trouble-free and corrosion-free service. AL fans feature all-welded angle frame construction for a rugged and durable unit. The fan panel has a deep spun orifice for maximum efficiency. AL fans utilize Coolair s exclusive drive assembly used on our fans for over 80 years. The die-formed aluminum blades are bolted to a cast aluminum hub, which also serves as the fan pulley. Power is applied through V-belts directly to the propeller with the blade load concentrated directly over the fan bearings, thus eliminating overhung bearing load. AL fans are available with single- or two-speed totally enclosed motors. PERFORMANCE RATINGS Fan Fan Motor Fan AMERICAN COOLAIR CORPORATION certifies that the performance data for the type AL wall fan models shown below are based on tests conducted in an accredited laboratory in accordance with ANSI/AMCA Standard 210-07. CUBIC FEET PER MINUTE (CFM) AT STATIC PRESSURE 0" S.P..05" S.P..10" S.P..125" S.P..15" S.P. Model Size HP RPM CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP AL24G 1/4 688 5,293 0.24 5,026 0.25 4,724 0.26 4,553 0.27 4,362 0.28 AL24H 24 1/3 769 5,916 0.33 5,680 0.35 5,421 0.36 5,279 0.37 5,128 0.38 AL24J 1/2 891 6,855 0.51 6,654 0.53 6,438 0.55 6,324 0.56 6,205 0.57 AL24K 3/4 1042 8,017 0.83 7,846 0.84 7,574 0.86 7,574 0.87 7,478 0.88 AL30G 1/4 491 7,205 0.24 6,625 0.25 5,997 0.27 5,648 0.27 5,239 0.28 AL30H 30 1/3 531 7,792 0.29 7,258 0.32 6,690 0.33 6,386 0.34 6,056 0.34 AL30J 1/2 641 9,406 0.52 8,968 0.54 8,512 0.56 8,276 0.57 8,034 0.58 AL30K 3/4 739 10,845 0.80 10,466 0.83 10,076 0.85 9,877 0.86 9,674 0.87 AL36H 1/3 447 9,735 0.29 9,007 0.32 8,241 0.34 7,773 0.36 7,103 0.38 AL36J 36 1/2 524 11,411 0.47 10,793 0.51 10,160 0.54 9,832 0.55 9,477 0.56 AL36K 3/4 615 13,393 0.75 12,868 0.80 12,334 0.84 12,063 0.86 11,790 0.87 AL36L 1 692 15,070 1.07 14,604 1.12 14,132 1.18 13,894 1.20 13,654 1.22 AL42H 1/3 322 12,106 0.30 10,921 0.33 9,919 0.36 8,430 0.37 7,149 0.39 AL42J 42 1/2 371 13,948 0.46 12,986 0.49 11,525 0.53 10,797 0.54 10,159 0.56 AL42K 3/4 430 16,166 0.71 15,372 0.75 14,318 0.79 13,625 0.81 12,938 0.83 AL42L 1 492 18,497 1.07 17,821 1.11 17,009 1.15 16,513 1.18 15,932 1.20 AL48J 1/2 307 16,740 0.49 15,278 0.52 13,371 0.54 12,370 0.54 11,062 0.56 AL48K 48 3/4 358 19,521 0.77 18,315 0.82 16,814 0.84 15,964 0.85 15,121 0.85 AL48L 1 408 22,248 1.14 21,212 1.19 20,001 1.23 19,305 1.24 18,565 1.25 AL54L 54 1 374 23,911 1.06 22,693 1.11 21,283 1.16 20,480 1.18 19,618 1.20 AL54M 1 1/2 414 26,496 1.44 25,381 1.50 24,165 1.55 23,491 1.58 22,766 1.60 4

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 Date: 2/27/2017 fax: (303) 457-2801 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-10 Submittal Description: Circulating Fans Manufacturer: Schaefer Quantity: 6 ea Product Data Information: VK12PA 1/10 HP 1.3 amp

VK12 12" Versa-Kool Circulation Fan Able to Ship Small Parcel : Yes Air Velocity (@ 5 times diameter) : 680 BESS Lab Performance Test No. : 12370 Blade Color : Metallic Blade Material : Aluminum CFM (free air) : 1470 CFM Calculation Standard : ANSI/AMCA Standard 230-99 CFM Range (Free Air) : 1001-2500 CFM/Watt (free Air) : 14 Component Certifications : Motor - UL/CSA Cord : Included - Not Wired Cord Length (feet) : 5 Country of Origin : US Diameter (inches) : 12 Display Name : VK12 Drive Type : Direct Fixed or Portable : Fixed Frequency (Hz) : 60 Guard Color : White Guard Material & Coating : Powder Coated Steel Guard Spacing (inches) : 1/2-1 UL507 Housing Color : White Max RPM : 1725 Mount Included : VS12FMT Mount Type Included : Ceiling Nameplate Amps : 1.3/.65 Number of Wings : 3 Oscillating : No Phase : 1 Power (hp) : 1/10 Product Color : White Product Shipping Dimensions : 15 X 14 X 16 Product Weight (pounds) : 18 Speed Control Compatible : Yes Speeds : 1 Switch : Not included VFD Compatible : No Voltage : 115/230

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-11 Submittal Description: Natural Gas Unit Heaters Manufacturer: Modine Quantity: 2 ea Product Data Information: PTC 156A

AccuSpec V4.6.1 Transaction #: 8174020 JOB TITLE: Cabrillo College Date: 10/24/2016 Approved By: Submittal review and approval required prior to listed unit(s) being released for production and shipment. Unit(s) configured based on information provided. The Approver is responsible for ensuring the units, options, and accessories meet the job specifications.

AccuSpec V4.6.1 SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Cabrillo College Date: 10/24/2016 Location: Engineer: Submitted by: Chris Willhoff Architect: Contractor: Model Number PTC156AS0111SBAN Quantity of Units 2 Btu/Hr Input 155,000 Btu/Hr Output 144,150 CFM 2600 Altitude 0-2000 Temperature Rise (degrees F) 51 External Static Pressure (E.S.P) 0.00 Total Static Pressure (T.S.P.) 0.00 Gas Type Natural Gas Control Type Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry Supply Voltage 115/60/1 Control Voltage 24V Motor HP 1/3 Motor RPM 1075 Blower RPM N/A Heat Exchanger Type Aluminized Steel Heat Exchanger/Burner Options & Accessories (See Attached Pages) Unit Tag Remarks

AccuSpec V4.6.1 SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Model Description Qty Tag PTC156AS0111SBAN Propeller Unit Heater 2 65907 PTC156AS0111SBAN 2 57920 Vertical Concentric Vent Kit 2

AccuSpec V4.6.1 PTC MODEL NOMENCLATURE 1,2,3 4,5,6 7 8 9,10 11,12 13 14 15 16 PTC 156 A S 01 11 S B A N 1,2,3 - Product Type PTC - Separated Combustion, High Efficiency Condensing Propeller Unit 4,5,6 - Furnace Input Rating 156-155,000 Btu/hr Input 7 - Heat Exchanger Type A - Aluminized Steel Heat Exchanger and Burner 8 - Pilot Ignition S Direct Spark Ignition 9,10 - Motor and Drive Code (Power Code) 01-115V motor 11,12 Gas and Valve/Ignition Control Type (Control Code) 11 - Natural, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 13 Fan Guard Type S - Standard Fan Guard 14 Development Sequence B - Current 15 Future A For Future Use 16 Factory Installed Option N - None

AccuSpec V4.6.1 GENERAL PERFORMANCE DATA General Performance Data Model PTC 156 At 0 Elevation Btu/Hr. Input 155,000 Btu/Hr. Output 144,150 Entering Airflow (CFM) 2600 Outlet Velocity 862 Air Temp. Rise ( F) 51 Mounting Height (Max Ft.) 1 18 Heat Throw (Max. Mtg. Ft.) 2 62 Unit Total Power (Amps) 6.75 Condensate Produced (gal/hr) 1.1 As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 155,000 Btu/Hr. Output 144,150 Configured Air Temp Rise ( F) 51 Motor Data Horse Power 1/3 RPM 1075 Type P.S.C. Motor Amps at 115V 4.60 Clearances to Combustibles Top and Bottom 6 Vent/Combustion Air Connector 6 Access Side 6 Non-Access Side 6 Rear 18 1 At 65 F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit. 2 Heat Throws are calculated at 65 F ambient with a 51 F air temperature rise with the unit mounted at a maximum mounting height of 18 feet.

AccuSpec V4.6.1 DIMENSIONS UNIT Model PTC Dimensions Model Size PTC156 Dimensions (inches) A 35.53 J 8.09 B 23.06 K 8.45 C 22.05 L 13.45 D 22.52 M 3.98 E 21.18 N 1.54 F 4.50 P 22.03 G 7.98 Q 2 45.83 H 10.18 R 33.83 I 2.15 Gas Connection 1/2 Fan Diameter 20 Vent Pipe Connection Size 4 Combustion Air Inlet Pipe Connection Size 4 Approx. Shipping Weight 165 lbs. 1 All models have 4 holes for mounting. Listed is the hole diameter and threads per inch to accept threaded rod. 2 Dimension equals overall R dimension plus 12.

Standards All unit(s) shall include: ETL design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for Gas Unit Heater and Gas-Fired Duct Furnaces for safe operation, construction, and performance Mechanical Configuration Condensing furnace section with 93% minimum efficiency provided by an indirect-fired tubular heat exchanger with individually fired tubes coupled to a secondary recuperative heat exchanger for maximum heat recovery. Venting/Combustion Air Arrangement The unit shall be separated combustion. The venting shall be a power exhausted arrangement with a separate combustion air intake pipe connection to allow for fresh combustion air from outside the conditioned space. The unit shall be tested to insure proper ignition when the unit is subjected to 40 mile per hour wind velocities. The unit shall also include a factory mounted differential pressure switch designed to prevent main burner ignition until positive venting has been proven. Venting shall be Schedule 40 PVC. For Canadian installations, all vent pipe and components must be approved to ULC S636. Unit Casing The unit heater(s) casing shall be constructed of not less than 20 gauge aluminized steel with minimization of exposed fasteners. All exterior casing parts shall be cleaned of all oils and a phosphate coating applied prior to painting. The exterior casing parts shall then be painted with an electrostatically applied baked-on gray-green polyester powder paint (7- mil thickness) for corrosion resistance. The unit shall be furnished with horizontal air deflectors. The deflectors are adjustable to provide for horizontal directional airflow control (up or down). Furnace Section The heat exchanger(s) shall be made of 18 gauge aluminized steel tubes and headers. Each heat exchanger tube shall be individually and directly flame-fired. The heat exchanger tube shall be crimped to allow for thermal expansion and contraction. The flue collector box shall be made of 20 gauge AL29-4C stainless steel. The thermal efficiency of the unit(s) shall be a minimum of 93% efficient for all air flow ranges through the use of a secondary recuperative heat exchanger. The secondary heat exchanger shall be constructed of AL29-4C stainless steel to withstand the corrosive environment of condensing gas fired equipment. The heat exchanger(s) seams and duct connections shall be certified to withstand 0.9" W.C. external static pressure without burner flame disturbance. The burner(s) shall be in-shot type, directly firing each heat exchanger tube individually and is designed for good lighting characteristics without noise of extinction for both natural and propane gas. The ignition controller(s) shall be 100% shut-off with continuous retry. The gas pressure shall be between 6-7" W.C for natural gas. The solid state ignition system shall directly light the gas by means of a direct spark igniter each time the system is energized.

The unit gas controls shall be provided with the following: Single-stage gas controls with a single-stage combination gas control, an ignition control. The unit fires at 100% full fire based on a call for heat from a room thermostat. An automatic reset high limit switch mounted in the air stream to shut off the gas supply in the event of overheating. An automatic reset high limit switch mounted on the power exhauster housing to shut off the gas supply in the event of overheating flue gas temperatures. A condensate drain line overflow switch that senses if the condensate line is clogged and shuts the unit heater down. The switch is factory mounted inside the unit cabinet and wired to the unit controls. An energy-saver control utilizes stratified ceiling air to heat the space at floor level before turning on the gas controls. Its operation is independent of the room thermostat and should have a higher set-point than the room thermostat. The Stat is factory mounted outside the unit and wired into the contractor convenience box. A time delay relay that delays the start of the air mover to allow the heat exchanger a warm-up period after a call for heat. The time delay relay shall also continue the air mover operation after the thermostat has been satisfied to remove any residual heat in the heat exchanger. The unit shall be orificed for 0-2000 feet elevation above sea level. Electrical All electrical components shall carry UL, ETL, or CSA listing. A low voltage terminal board shall be provided for direct wiring connection to an external thermostat. A Contractor Convenience Package that consists of an external junction box featuring simple connection of supply power wiring internally, thermostat wiring to terminals eternally, an On/Off switch, a single 115V outlet for connection of an external condensate pump, and status indicator lights to display the operational state of the unit shall be factory mounted on the rear panel of the casing. A single 115V to 24V step down transformer shall be provided for all unit controls. Air Mover The motor horsepower shall be 1/3 H.P. The motor wiring shall be in flexible metal BX conduit. The motor shall be controlled by a time delay relay. Propeller models shall meet the following requirements: The motor type shall be Single-Speed, Totally Enclosed (TE). The air mover motor shall be a 115V motor. Mounting The unit shall be equipped with tapped holes to accept 3/8-16 threaded rod for suspension. Propeller Unit to have two point adjustable suspension points to allow for level hanging with a variety of accessories.

Accessories The following field installed accessory control devices shall be provided with the unit: A vertical concentric vent kit shall be provided to allow the vent outlet and combustion air inlet pipes to penetrate the building roof through one opening. A condensate drain kit consisting of one threaded PVC elbow and two specially designed condensate traps to allow the unit to operate and drain properly.

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-12 Submittal Description: Ridge Vent Motor Manufacturer: Wadsworth Quantity: 4 ea Product Data Information: VC2000 115 v 1/5 HP 2.5 amp

DriveUnits Take advantage of Wadsworth s 40 plus years of experience in automating vents. Our drive units set the standard for powerful performance, smooth operation and reliability. VC 100A Vent Drive VC 2000 Vent Drive FEATURES Gear motor: 1/20 HP - 115V; 60Hz; 0.68 amps - TENV Ball bearing motor with copper windings - Class B insulation Gear reducer: total gear reduction 1900:1; 0.85 and 2.5 RPM final output Output torque 500 inch lb / 56 Nm Lifts up to 75 of 4 polycarbonate roof ridge vent or 125 of 4 polycarbonate side vent FEATURES Gear motor: 1/5 HP - 115V; 60Hz; 2.5amps - TEFC Ball bearing motor with copper windings - Class B insulation Gear reducer: total reduction 1350:1; 1.2 and 3 RPM final output Output torque 1500 inch lb / 169 Nm Lifts up to 325 of 4 polycarbonate roof ridge vent or 400 of 4 polycarbonate side vent SHAFT SIZE Wadsworth s drive units can be ordered to fit either a 1-3/8 or a 1-5/8 shaft. Measure the outside diameter (O.D.) of your shaft to determine which size is correct for your greenhouse. 1-3/8 O.D. 1-5/8 O.D. BENEFITS Thermal overload protection automatic reset continuous duty Quick reversing Worm gear with tapered roller bearings on dual output shafts immersed in synthetic oil Dual output shaft Sealed for life; limited or no maintenance required Superior heat dissipation through fin & casting design To find out more call 800.821.5829, email sales@wadsworthcontrols.com or visit www.wadsworthcontrols.com

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-13 Submittal Description: Shade System Motor Manufacturer: Wadsworth Quantity: 2 ea Product Data Information: VC2000 115 v 1/5 HP 2.5 amp

DriveUnits Take advantage of Wadsworth s 40 plus years of experience in automating vents. Our drive units set the standard for powerful performance, smooth operation and reliability. VC 100A Vent Drive VC 2000 Vent Drive FEATURES Gear motor: 1/20 HP - 115V; 60Hz; 0.68 amps - TENV Ball bearing motor with copper windings - Class B insulation Gear reducer: total gear reduction 1900:1; 0.85 and 2.5 RPM final output Output torque 500 inch lb / 56 Nm Lifts up to 75 of 4 polycarbonate roof ridge vent or 125 of 4 polycarbonate side vent FEATURES Gear motor: 1/5 HP - 115V; 60Hz; 2.5amps - TEFC Ball bearing motor with copper windings - Class B insulation Gear reducer: total reduction 1350:1; 1.2 and 3 RPM final output Output torque 1500 inch lb / 169 Nm Lifts up to 325 of 4 polycarbonate roof ridge vent or 400 of 4 polycarbonate side vent SHAFT SIZE Wadsworth s drive units can be ordered to fit either a 1-3/8 or a 1-5/8 shaft. Measure the outside diameter (O.D.) of your shaft to determine which size is correct for your greenhouse. 1-3/8 O.D. 1-5/8 O.D. BENEFITS Thermal overload protection automatic reset continuous duty Quick reversing Worm gear with tapered roller bearings on dual output shafts immersed in synthetic oil Dual output shaft Sealed for life; limited or no maintenance required Superior heat dissipation through fin & casting design To find out more call 800.821.5829, email sales@wadsworthcontrols.com or visit www.wadsworthcontrols.com

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-14 Submittal Description: Shade Cloth Manufacturer: Quantity: ea Product Data Information: Aluminet 50% ICFR

Aluminet I Open Screens Aluminet 40 I Aluminet 50 I Aluminet 60 I Aluminet 70 I Shade percentage Diffused light transmission Aluminet I Open Screens provide multiple solutions where both heat-stress reduction and frost protection is necessary. The double-sided reflection screen helps to protect your crop against both midday heat stress and overnight frost. Light transmission parameters were tested according to ASTM-D 1746 & ASTM-D 1494 methods. Aluminet IC Closed Screens for Energy-Saving Energy saving Aluminet 40 I 40-43% 72% 15% Aluminet 50 I 49-53% 65% 20% Aluminet 60 I 62-64% 55% 36% Aluminet 70 I 70-74% 45% 45% Aluminet IC TS Aluminet IC 50 Aluminet IC 60 Aluminet IC 70 Aluminet IC 100 Energy Saving Diffused light transmission Shade percentage Aluminet IC TS 43% 94-95% 22-24% Aluminet IC 50 55% 74-75% 46-48% Aluminet IC 60 60% 60-61% 59-61% Aluminet IC 70 70% 45-46% 73-75% Aluminet IC 100 75% 0% 98-99.5% Aluminet IC is highly recommended for greenhouses where a high level of energy saving is essential. Tests show that Aluminet s insulation properties contribute significantly to reduced energy consumption. Energy savings tested by the INTRON Quality Assessment Institute in Test no. R20010307 on Nov. 8, 2001. Light transmission parameters were tested according to ASTM-D 1746 & ASTM-D 1494 methods. Fire retardant parameters were tested according to NFPA 701 regulations.

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-15 Submittal Description: Insec Screen for ridge vents and evaporative pad system Manufacturer: Econet Quantity: ea Product Data Information: Econet 1535

ECONET 1535 Product information Main Function Material composition Flame retardant Warranty Insect Control 90% Polyolefin, 10% Acrylic No Warranty five (5) years under all types of greenhouse covering and three (3) years with outdoor use, see Svensson s limited warranty for all terms, conditions, and exclusions in writing.<br /> <br /> Svensson does not provide any warranties with respect to the effectiveness of the nets to keep insects in or outside a space. Any and all liability of Svensson with respect thereto is to excluded. Properties Value Unit Test methods Weight 106 g/m² Tensile strength (length/width)* 1116/820 N/5cm ISO 13934-1 Elongation (length/width)* 32/34 % ISO 13934-1 Warp Density 31.5 yarns/cm Scheringdichtheid Weft Density 20 yarns/cm Inslagdichtheid Opening (mm) 0.15 x 0.35 mm Ventilation reduction 40 % Integrated sphere Energy saving 40 % Svensson method * Width 50 mm ** PAR = 400-700 nm, accuracy +/- 1% *** UV-light = 300-400 nm This product image is for illustrative purposes only and may vary in appearance and design from the delivered product. Although the information in this data sheet has been composed with care, Svensson does not accept any liability in respect of its accuracy. Further information concerning the product and its installation may be obtained from Svensson and its authorized distributors. Svensson s products and name are protected by patent and other intellectual property rights. Products marked FR are flame retardant. No other products delivered by Svensson are flame retardant. AB Ludvig Svensson is an ISO 14001/90001 certified company.

NE XUS GREENHOUSE CORPORATION 10983 LEROY DRIVE NORTHGLENN, CO 80233 phone: 303-450-8536 fax: (303) 457-2801 Date: 2/27/2017 Cabrillo College Nexus Job #: A32478 Submittal Number: NEX-SUB-16 Submittal Description: Control System Manufacturer: Wadsworth Quantity: ea Product Data Information: Seed Controller

Something new under the sun Introducing Seed A remarkable new touchscreen climate control with a user interface that makes managing growing environments child s play. Engineered for power; designed for ease. FEATURES Highly responsive touchscreen technology Graphic interface provides extensive information at a glance Navigate easily with a swipe of the screen Design accommodates beginners and experts Seamless access from multi-zone home screen to detailed settings for individual equipment Color coding indicates each zone s status, allowing an overview of multiple zones from the home screen Zone screens feature: Four time periods Sensor readings Banner displays outdoor conditions, rain, snow, day or night, when outdoor temp and humidity sensors are attached Data from Weather Station (temp, humidity, VPD, wind speed & direction and solar intensity) Tracks sunrise and sunset Current Conditions screen displays comprehensive information for each zone including: Status listing of each equipment s current conditions Displays explanation for equipment status and anticipated changes Desired temperature range Current temperature View equipment settings, overrides, lockout and setpoints from a single screen Intuitive programming directs user to appropriate screen based on equipment functionality (e.g. curtains heating, solar, cooling) Tracks Vapor Pressure Deficit (VPD) and Daily Light Integral (DLI) in Moles/m2/day, kwh/m2/day, Joules/m2/day View and adjust each zone s time periods from a single screen Adjust settings in the greenhouse, at the control Select multiple sensors and equipment to graph on Charting screen Charting screen tracks equipment usage and sensor readings over a 7-day period Graph data can be viewed from a single week down to hourly increments, and anything in-between NEMA 4 rated cabinet s small size makes for easy installation Modular design allows for easy expansion of inputs/outputs To find out more call 800.821.5829, email sales@wadsworthcontrols.com or visit www.wadsworthcontrols.com