Inverter Air Source Heat Pump Monobloc system

Similar documents
Inverter Air Source Heat Pump Split system

General safety precautions English

General safety precautions English

General safety precautions English

General safety precautions English

General safety precautions English

General safety precautions English

DAIKIN AIR CONDITIONER

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Ductless Split Air Conditioner

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

Bar Fridge USER MANUAL MB46W

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Split-type Air-Conditioner

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Safety Precautions (1)

Split-type Air-Conditioner

Split-type Air-Conditioner

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

Model: Ecostrad Thermostrip with Remote

Operating Instructions Air Conditioner

[FLARE CONNECTION TYPE] ATTENTION

Local air conditioner

Air-Water heat pump Small GT

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Use & Care Manual Electric Portrait with remote control DBL-2000-DD5

1. BEFORE INSTALLATION

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Operating Instructions

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Double Door - Dual Zone Wine Cooler

Air to Water Heat Pump -Mono Control Unit. user manual. imagine the possibilities

Heat Pump / Air Conditioner

Dehumidifier User Manual. (For the series of DP40~DP70)

1. BEFORE INSTALLATION

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Installation Instructions

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

GENERAL INFORMATION CONTENTS

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

INSTALLATION INSTRUCTIONS

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Operating Instructions Air Conditioner

Air conditioner. User manual AC777KN4DCH

GDDEM10 DEHUMIDIFIER

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Operating Instructions Air Conditioner

1. BEFORE INSTALLATION

Horizontal/Side Discharge Condensing Units

Installation Instructions 30 French Door Built-in Wall Ovens

Instruction Manual Refrigerator-freezer

NEXXOS INVERTER USER MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

Installation Instructions

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION AND USER MANUAL

SYSTEM Inverter Air Conditioners

Split Air Conditioner

Split Air Conditioner

1. BEFORE INSTALLATION

Dehumidifier. Instruction Manual

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

Convection Panel Heater

ART cm Island Curved Glass

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

30-pint Dehumidifier User Guide

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

ULTRA LOW TEMPERATURE FREEZER. User Manual

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Inverter Split-type Room Air Conditioner

TECHNICAL DATA & SERVICE MANUAL

Operating Instructions Air Conditioner

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

100cm Chimney Hood GB IE

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

INSTALLATION AND USER MANUAL

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

Swimming Pool Heat Pump

Installation Manual. Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Transcription:

Inverter Air Source Heat Pump Monobloc system Product Data & Installation Manual AXAI-06M & AXAI-09M AXAI-12M & AXAI-15M TABLE OF CONTENT

INSTRUCTIONS 1 This manual 1 Items inside product box. 2 Tools needed to install these products.. 3 SAFETY PRECAUTIONS.3 Warning..4 Caution. 5 Materials needed to install the heat pump. 6 Cycle diagram 6 OVERVIEW OF THE UNIT....7 The unit (External & Internal): AXAI-06M & AXAI-09M. 7 The unit (External & Internal): AXAI-12M & AXAI-15M.. 8 Wiring Diagram...9 Electrical Wiring Diagram for the 6&9KW...9 Electrical Wiring Diagram for the 12&15KW...10 Field Wiring 11 WATER PIPE-WORK.....12 Checking the water circuit..12 Charging water. 12 Water Flow Rates..12 INSTALLATION OF THE MAIN UNIT. 13 Precautions for selecting the location.. 13 Installation space 13 Mounting the unit....14 SPECIFICATION... 16

READ THIS MANUAL CAREFULLY BEFORE STARTING THE INSTALLATION OF THIS PRODUCT. DO NOT THROW IT AWAY. KEEP IT IN YOUR FILES FOR FUTURE REFERENCE. BEFORE OPERATING THE UNIT, MAKE SURE THE INSTALLATION HAS BEEN CARRIED OUT CORRECTLY BY A PROFESSIONAL DEALER. IF YOU FEEL UNSURE ABOUT OPERATION, CONTACT YOUR DEALER FOR ADVICE AND INFORMATION. INTRODUCTION This manual This manual includes the necessary information about the unit. Please read this manual carefully before you install the product. Domestic hot water tank option An optional domestic hot water tank with integrated electrical booster heater can be connected to the unit. The domestic hot water tank is available in different sizes. Items inside product box Before starting installation, please make sure that all parts are found inside the product boxes The Unit Box Item Image Quantity AXAI-06M & AXAI09M 1 2

AXAI-12M & AXAI15M 1

4 The manual 1

Tools needed to install these products 1. Hammer Drill 2. Sprit Level 3. Pipe Bending equipment for refrigeration pipe 4. Pipe bending equipment for water pipe 5. Brazing torch 6. Flairing tool 7. Tape measure 8. Torque spanners 9. Pipe cutters 10. Socket set with metric sockets 11. Phillips 2 screwdriver 12. Electrical terminal screwdriver 13. Electrical crimping tool 14. Electrical Side cutters 15. Trimming knife 16. Wire strippers 17. Hack saw 18. Masonry drill bits for fixings 7mm and 10mm are recommended 19. Masonry core bit for interconnecting services 75mm recommended 20. Vacuum pump 21. R410a Gauges 22. Torr gauge 23. Hex keys 4mm 24. Adjustable spanner 25. OFN & Regulator 26. PPE ie gloves, glasses and steal toe protectors SAFETY INSTRUCTIONS To prevent injury to the user, other people, or property damage, the following instructions must be followed. Incorrect operation due to ignoring these instructions may cause harm or damage. Install the unit only when it complies with local regulations, by-laws and standards. Check the main voltage and frequency. This unit is only suitable for earthed sockets. An isolation switch is required for both indoor and outdoor units. The following safety precautions should always be taken into account: - Be sure to read the following WARNING before installing the unit. - Be sure to observe the cautions specified here as they include important items related to safety. - After reading these instructions, be sure to keep it together with the manual in a handy place for future reference. 5

Ensure the units are securely installed. If the unit is insufficiently secured or installed, the unit could fall causing injury. The minimum support weight of 20g/mm² of the installation is required. When installing the unit in an enclosed area or a confined space please consider the room measurements and sufficient ventilation to prevent the asphyxia caused by the leakage of refrigerant. Use the specified electrical wires and attach the wires firmly to the terminal board (connection in such a way that the stress of the wires is not applied to the sections). Incorrect connection and fixing could cause a fire. Be sure to use the correct or specified materials for the installation work. The use of defective parts / materials could cause an injury due to possible fire, electric shocks, the unit falling etc. Perform the installation securely and please refer to the installation instructions. Incorrect installation could cause an injury due to possible fire, electric shocks, the unit falling, leakage of water etc. Perform electrical work according to the installation manual and be sure to use a dedicated section. If the capacity of the power circuit is insufficient or there is an incomplete electrical circuit, it could result in a fire or an electric shock. The unit must always have an earthed connection. If the power supply is not earthed, you may not connect the unit. Do not attempt move/repair the unit yourself if you are not a LCP installer. Improper movement or repair on the unit could lead to water leakage, electrical shock, injury or fire. Have any repairs and/or maintenance only carried out by a recognized service engineer. Do not plug or unplug the power supply during operation There is a risk of fire or an electric shock Do not touch/operate the unit with wet hands There is a risk of fire or an electric shock Do not place a heater or other appliances near the power cable There is a risk of fire or an electric shock Be cautious that water could not be poured to the product directly, do not allow water to run into electric parts There is a risk of fire or an electric shock IF THE PRODUCT IS NOT USED FOR LONG PERIODS OF TIME, WE STRONGLY RECOMMEND NOT TO SWITCH OFF THE POWER SUPPLY TO THE PRODUCT. IF THE POWER IS NOT SUPPLIED, SOME OF THE PRODUCT-PROTECTING ACTIONS (SUCH AS WATER PUMP ANTI-LOCKING & CRANK CASE HEATER) WILL NOT BE OPPERATIONAL 6

Do not install the unit in a place where there is a chance of flammable gas leaks. If there is a gas leak and gas accumulates in the area surrounding the unit, it could cause an explosion. Perform the drainage/piping work according to the installation instruction. If there is a defect in the drainage/piping work, water could leak from the unit and household goods could get wet and be damaged. Do not clean the unit when the power is on. Always shut off the power when cleaning or servicing the unit. If not, it could cause an injury due to the high speed running fan or an electrical shock. Do not continue to run the unit when there is something wrong or there is a strange smell. The power supply needs to be shut off to stop the unit; otherwise this may cause an electrical shock or fire. Be cautious when unpacking and installing the product. Sharp edges could cause injury. Especially watch the edges and the fins on the heat exchanger of the product. Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of the product. The installation of the unit must be level and secure. To avoid vibration and or water leakage Do not put your fingers or others into the fan, or evaporator. The fan runs at high speed, this could cause serious injury. In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility. This appliance has not been designed for use by persons (including children) with reduced physical, sensorial or mental faculties or by persons without any experience or knowledge of heating systems, unless they act under the safety and supervision of a responsible person or have received prior training concerning the use of the appliance. Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. The means for disconnection must be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase)conductors. 7

Materials needed to install the heat pump Water connection on the indoor unit is 1-1/4 female connection for both flow and return. 3 way Valve when requiring a hot water & heating system. 2 way Valve when requiring zone heating NB each zone requires a 2 way valve NB The water connection can be reduced using a male to female bush Power cable to the unit :6KW&9kw used 3 core 4mm2 shielded heat resistance cables, 12KW&15kw used 3 core 6mm2 shielded heat resistance cables An isolator is required as part of the field wiring. Power cable to the indoor unit 3 core 2.5mm2 shielded heat resistance cable. An isolator is required as part of the field wiring. Low voltage inter connecting cable.75mm shielded twisted pair. NB all controls cable must be installed 300mm away from mains cables The required insolation for the field pipe installation is Class 0. Heating operation range The Unit Dry bulb Wet Bulb Inlet Outlet Heating Max. 35 26 50 55 Min. -15 / 15 20 8

Cycle diagram(axai-06m / AXAI-09M/ AXAI-12M/AXAI-15M) OVERVIEW OF THE UNIT External: AXAI-06M & AXAI-09M 9

Internal: AXAI-06M & AXAI-09M 10

External: AXAI-12M&AXAI-15M Internal: AXAI-12M&AXAI-15M 11

Wiring Diagram Electrical Wiring Diagram for the 6&9KW 12

Electrical Wiring Diagram for the 12&15KW NB cable entry either top or bottom of the unit The unit Separated Power supply Model Separated Power supply / Rated Current AXAI-06M 2200W / 9.6A AXAI-09M 2500W /11.9A AXAI-12M 4200W / 14A AXAI-15M 4400W /19A 13

WARNING A main switch or other means for disconnection, having a contact separation in all poles, must be incorporated in the fixed wiring in accordance with relevant local and national legislation. Switch off the power supply before making any connections. All field wiring and components must be installed by a licensed electrician and must comply with relevant European and national regulations. The field wiring must be carried out in accordance with the wiring diagram supplied with the unit and the instructions given below. Be sure to use a dedicated power supply. Never use a power supply shared by another appliance. Be sure to establish an earth. Do not earth the unit to a utility pipe, surge absorber, or telephone earth. Incomplete earth may cause electrical shock. Be sure to install an earth leakage protector. Failure to do so may cause electrical shock. Wiring overview The table below gives a wiring overview of required field wiring. AXAI-06M AXAI-09M AXAI-12M AXAI-15M United Power supply (outdoor power supply must fuse down the indoor power supply to 20 amps) Separated Outdoor Power supply Communication cable AWG9(6.63m m 2 )*3 AWG13(4mm AWG13(4mm 2 2 )*3 )*3 AWG9(6.63mm AWG8(8.37m 2 )*3 m 2 )*3 AWG8(8.37m m 2 )*3 AWG11(4.mm AWG11(4.mm 2 2 )*3 )*3 Twin-core twisted pair shielding (0.75mm 2 )*2 14

WATER PIPE-WORK Checking the water circuit NB: The 3-way valve is not supplied with this system Before continuing the installation of the unit, check the following points: The maximum water pressure is 10 bar. Shut-off valves are not included with the unit. To facilitate service and maintenance, please install one at each water inlet/outlet. Mind position of the shut-off valves. Orientation of the integrated drain and fill valves is important for servicing. Take care that the components installed in the field piping can withstand the water pressure. NEVER USE UN-COATED PARTS IN THE WATER CIRCUIT. EXCESSIVE CORROSION OF THESE PARTS MAY OCCUR AS COPPER PIPING IS USED IN THE INTERNAL WATER CIRCUIT OF THE UNIT. WHEN USING A 3-WAY VALVE OR A 2-WAY VALVE IN THE WATER CIRCUIT. THE RECOMMENDED MAXIMUM CHANGEOVER TIME OF THE VALVE SHOULD BE LESS THAN 60 SECONDS. Charging water 1. Connect the water supply to a drain and fill valve. 2. Make sure the automatic air purge valve is open (at least 2 turns). 3. Fill with water until the water manometer indicates a pressure of approximately 2.0 bar. Remove air in the circuit as much as possible using the air-purge valves. Air present in the water circuit might cause malfunctioning of the optional backup heater. 4. Backup heater: Check that the backup heater vessel is filled with water by opening the pressure relief valve. Water must flow out of the valve. NOTE During filling, it might not be possible to remove all the air in the system. Remaining air will be removed through the automatic air purge valves during first operating hours of the system. Additional filling with water afterwards might be required. The water pressure indicated on the water manometer will vary depending on the water-temperature (higher pressure at higher water temperature). However, at all times water pressure should remain above 0.3 bar to avoid air entering the circuit. The unit might dispose some excessive water through the pressure relief valve. Water quality must be according to EN directive 98/83 EC. Water Flow Rates 6 kw 1.03m³ /h 9kw 1.55m³ /h 15

12kw 2.06m³ /h 15kw 2.6m³ /h INSTALLATION OF THE MAIN UNIT Installation guidelines Precautions for selecting the location WARNING MAKE SURE TO PROVIDE FOR ADEQUATE MEASURES IN ORDER TO PREVENT THAT THE OUTDOOR UNIT WILL BE USED AS A SHELTER BY SMALL ANIMALS. SMALL ANIMALS MAKING CONTACT WITH ELECTRICAL PARTS CAN CAUSE POSSIBLE MALFUNCTIONS, SMOKE OR FIRE. PLEASE KEEP THE AREA AROUND THE UNIT CLEAN. 1. Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified. 2. Choose a location where the hot air discharged from the unit or the operation noise will not cause a nuisance to the neighbors of the user. 3. Avoid places near a bedroom and the like, so that the operation noise will cause no trouble. 4. There must be sufficient space for carrying the unit into and out of the site. 5. There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet. 6. The site must be free from the possibility of flammable gas leakage in a nearby place. 7. Install units, power cords and inter-unit cables at least 3m away from television and radio sets. This is to prevent interference to images and sounds. 8. Depending on radio wave conditions, electromagnetic interference can still occur even if installed more that 3m away. 9. In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the outdoor unit. 10. The water will flows out of the unit when in defrost, do not place anything under the unit which must be kept dry. Installation space 16

Installation procedure Mounting the unit When installing the unit, please refer to Installation guidelines to select an appropriate location. 1. Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installation. 2. Prepare 4 sets of M8 foundation bolts, nuts and washers each (filed supply). 3. Fix the unit securely by means of the foundation bolts in accordance with the foundation drawing. It is best to screw in the foundation bolts until their length remains 20mm above the foundation surface. NB; Wall brackets are not supplied with the unit unless specified an installation guide is supplied within the wall brackets packaging Check before running Check before initial startup Turn off the power before connecting After installation, before accessing circuit breaker, please check the contents: 1. Field Wiring Make sure the wiring of instrument panel and the host, the wiring between the unit and the tank is in accordance with instructions guide, schematics is followed European and national laws. 2. Fuse or protective device 17

Checking fuses and installed protective equipment is ok. Make sure fuses and protection devices have not been overlooked. 3. The grounding wire Properly connect the ground terminals then tighten 4. Internal wiring Check whether the switch box is loose or electrical components is damaged 5. Fixed Check whether the machine fixed, to avoid abnormal noises and vibrations when starting. 6. The damage to the equipment Check whether there is damage to the internal components of the machine or tube is squeezed 7. The refrigerant leak Check whether the machine refrigerant leakage, if there is a leak, contact your local dealer 8. Power voltage Check the power supply voltage on the screen, the supply voltage must be consistent with the nameplate on the machine. 9. Air vent valve Make sure the air vent valve is open (at least 2 turns) 10. The atmospheric valve After checking the atmospheric valve is opened, whether the backup heater vessel filled with water. It is purified water instead of air. Running the system when backup heater vessel is unfilled with water will damage the heater 11. Shut-off valve Properly install shut-off valves, and open. Running the system when the valve closing will damage the pump! 18

Specification - DC Inverter - Monobloc type Heating Cooling DHW TECHNICAL DATA Nominal capacity Power input COP Nominal capacity Power input EER Nominal capacity COP Power supply Max. power input Max. current Power input Max. leaving water temperature (without using backup heater) KW KW W/W KW KW W/W KW KW W/W V/Ph/Hz KW A AXAI- S06M AXAI- S09M AXAI-S12M AXAI-S15M 6(2.1-6.5) 9(2.3-9.8) 12(4-13) 15(5-16) 1.39 2.1 2.82 3.57 4.3 4.3 4.25 4.2 5(1.9-5.33) 7(2.1-8.3) 10(2.2-10.5) 12(3-12.2) 1.34 2 3 3.75 3.73 3.5 3.3 3.2 5(2.0-5.8) 8(2.2-8.8) 10(2.2-11) 12.5(2.2-14) 1.34 2.2 2.8 3.52 3.74 3.63 3.57 3.55 220-240/1/50 2.2 3.2 4 4.8 9.6 14 18 21 58 Working temperature range -20-43 Refrigerant circuit Refrigerant Type R410A Compressor Brand*Q'ty/Type TOSHIBA*1/Inverter TOSHIBA*1/Inverter Twin Rotary Rotary Heat exchanger Type High efficiency hydrophilic fin-tube heat exchanger EEV Brand SAGInoMIYA Fan motor Quantity 1 1 2 2 Power input (W) 65 70 140 140 Size of fan mm 420*153 500*145 508*145 508*145 Liquid pipe inch(mm) 1/4(6.35) 3/8(9.52) 3/8(9.52) 3/8(9.52) 19

Water circuit Gas pipe inch(mm) 1/2(12.7) 5/8(15.88) 5/8(15.88) 5/8(15.88) Heat exchanger Type Stainless steel plate heat exchanger Rated water flow m 3 /h 1 1.5 2.1 2.6 Inlet/outlet pipe inch(mm) 5/4(31.75) Net Dimension (H*W*D) mm 860*900*325 1330*900*340 Packing Dimension (H*W*D) mm 1000*1000*400 1460*990*415 Net weight Kg 86 102 125 145 Gross weight Kg 98 118 135 160 Noise level NOTES: db(a) Capacities and power inputs based on the following conditions: 50 53 60 62 Heating: Water Inlet/Outlet temperature 30 /35. Outdoor air dry bulb/wet bulb temperature 7 /6 Cooling: Water Inlet/Outlet temperature 23 /18. Outdoor air dry bulb temperature 35 Domestic Hot Water: Water temperature in the tank 40. Outdoor air dry bulb/wet bulb temperature 7 /6 -The related data is subject to adjustment periodically because of technical improvement without further notice. Please refer to heat pump nameplate. 20