WARNING TABLE OF CONTENTS

Similar documents
Table Top Patio Heater

FLAME HEATER PYRAMID CLFH-10SS OPERATION INSTRUCTIONS

Flame Heater PH08 SERIES

GAS-FIRED INFRARED OUTDOOR PATIO HEATER INSTALLATION, OPERATION MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS AND OWNER S MANUALS

Gas Fire Patio Heater Q9

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

User Manual No. 5 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , OUTDOOR PATIO HEATER

User Manual No. 1 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , , OUTDOOR PATIO HEATER

Gas Fire Patio Heater Lhotse-817

User Manual No. 6 WARNING. WARNING: For Outdoor Use Only WARNING DANGER. Models: , OUTDOOR PATIO HEATER

User Manual No. 8 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: , OUTDOOR PATIO HEATER

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL # ZCV-2670-SS

Outdoor Flame Heater

AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

Riaza Tablemount Fire Bowl. Item# Model# HYUTT DANGER If you smell gas: 1. Shut off gas to the appliance.

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL # HSS-RS-TB

GAS-FIRED INFRARED OUTDOOR PATIO HEATER

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

Owner s Manual TABLETOP PATIO HEATER MODEL # PHRDGH/SS-TT

Gas Fire Patio Heater Kongur-500

Patio Heater_ _V4_ENG.book Page 1 Tuesday, September 2, :00 AM. AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

GAS-FIRED INFRARED OUTDOOR PATIO HEATER

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

AXIS OUTDOOR HEATER. Owner s Manual DANGER WARNING

TERRACE AND PATIO HEATER

BRONZE HSC PATIO HEATER. Call center for missing parts IMPORTANT DO NOT RETURN MODEL NO.: PG195H

TERRACE AND PATIO HEATER

Outdoor Tabletop Heater TTH20 Series

Using it in an enclosed space can kill you.

Stoneridge Fire Pit High Dining Table Assembly Instruction

OWNER S MANUAL DANGER WARNING. WARNING: For Outdoor Use Only WARNING PATIO HEATER MODEL # HLDS01. Français p. 22. p. 43

These instructions are for your safety. Please read them thoroughly before use and retain them for future reference

Area Heater AH100 Series

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING LAVA LITE KD

Assembly & User Instructions Mirage 38,200Btu Heat Focusing Patio Heater

Patio Heater Model No. GM and GM

Owner s Manual. 36" Square Gas Fire Pit Model#SRGF11610 DANGER WARNING. WARNING: For Outdoor Use Only.

Warning: For OUTDOOR USE only

OUTDOOR PATIO HEATER WARNING. WARNING: For Outdoor Use Only WARNING DANGER DANGER MODEL #GS-2400-BRZ GS-2400-BLK GS-2650-SS

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER MODEL:PHTRGH/SS MADE IN CHINA

GAS PATIO HEATER WITH LED TABLE. Call center for missing parts IMPORTANT DO NOT RETURN MODEL NO.: PG188H

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

Owner s Manual. WARNING: For Outdoor Use Only

Owner s Manual DANGER WARNING. WARNING: For Outdoor Use Only WARNING OUTDOOR PATIO HEATER

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2E-1

Rambo CAST IRON RING BURNERS OPERATING INSTRUCTIONS. C40LP 3 Ring Burner C50LP 4 Ring Burner

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

OUTDOOR PATIO HEATER MODEL #HSS-RS-GH. Model: HCPH MRKT / HCPHSSRKT

Aluminum Linear Fire Table

TABLE TOP PATIO HEATER Owner s Manual

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Dashley Outdoor Fire Table

OUTDOOR FIRE PIT FPS-DGHSS. ANS Z , Outdoor Decorative Gas Appliances CGA CR Outdoor Gas Fireplaces

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

DAYVA PREMIERE OUTDOOR HEATER Model HS041-2

User Manual No. 4 DANGER WARNING. WARNING: For Outdoor Use Only WARNING. Models: OUTDOOR PATIO HEATER

ANSI Z /CSA Gas-Fired Outdoor Infrared Patio Heaters. ANS Z /CSA Gas-Fired Outdoor Infrared Patio Heaters

35" Square Gas Fire Pit Model#SRGF11603B

OWNER S MANUAL. Smoky Hill 5pc Gas Firepit Chat Set. Product Code: D71 M25973 UPC Code: Date of Purchase: / /

Del Rio Tile Top Fire Pit Table

Outdoor Patio Heater

Comfort, Quality & Style Since 1998

OPERATING INSTRUCTIONS AND OWNERS MANUAL GAS-FIRED INFRA-RED TANK TOP HEATER

Owner s Manual OUTDOOR LIVING PERFECTED TONGA TORCH PORTABLE PROPANE

Assembly Instructions & User's Manual

USE AND CARE GUIDE PEDESTAL FIREBOWL

LP GAS PIZZA OVEN USER MANUAL

ASSEMBLY INSTRUCTIONS

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE!

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

For assistance with assembly, please contact Hayneedle Customer Care Center

LAVA 2G. 66,000BTU Instruction Manual. Outdoor Flame Heater. New Model YEAR I G N D E S E R T I E D

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

MODEL: CGG-306 Chef s Style Portable Tabletop Grill ASSEMBLY AND OPERATING INSTRUCTIONS

Propane Tabletop Patio Heater

WARNING FOR YOUR SAFETY FOR YOUR SAFETY. Outback Patio Heaters. Patio Heaters

Outdoor Radiant Gas Heater

Repeat procedures for other side.

ASSEMBLY INSTRUCTIONS

PROPANE GAS HEATER MODEL NO: GRH35 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC01/14

Owner s Manual DANGER WARNING WARNING. WARNING: For Outdoor Use Only WARNING LAVA LITE

for Assembly, Operating & Maintenance of THIS GAS UTILITY STOVE IS DESIGNED FOR OUTDOOR USE ONLY.

Wall Mounted Radiant Gas Heater

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Owner s Manual M odel # F-1350-FPT OUTDOOR FIRE PIT TABLE

ASSEMBLY INSTRUCTIONS

Mai805 Island. Instruction Manual and Installation Instructions

PAULIN PRODUCTS INDOOR HEATER

Model Numbers PT-16-TTC / PT-32-TTC / PT-47-TTC

Assembly & User Instructions Mirage 38,200Btu Heat Focusing Patio Heater with Speaker + Light

Outdoor Patio Heater INFRARED BURNER Model # LIP-10A-TGG-LPG-SP Item # 01775

Model No: Little Devil II (inc ss)

Wine Barrel Fire Pit. Owner s Manual. Item # 9716 DANGER

Assembly Instructions & User s Manual

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

COSY CLASSIC Portable Infra-Red open-air heater for non residental space heating Assembly and usage instructions. WARNING! For Outdoor Use Only.

Transcription:

WARNING Read the instructions before installation and use; This appliance must be installed and the gas cylinder stored in accordance with the regulations in force ; Do not obstruct the ventilation holes of the cylinder housing; Do not move the appliance when in operation; Shut off the valve at the gas cylinder or the regulator before moving the appliance; The tubing or the flexible hose must be changed within the prescribed intervals; Use only the type of gas and the type of cylinder specified by the manufacturer; In case of violent wind particular attention must be taken against tilting; Be careful, accessible parts may be very hot. Keep away from young children; This appliance requires installation by a competent person; For use only in well-ventilated areas. An amply ventilated area must have a minimum or 25% of the surface area open. The surface area is the sum of the walls surface; The use of this appliance in enclosed areas can be dangerous and is prohibited.this appliance shall not be used in basements or below ground level; This appliance shall be used for space heating only; This appliance has no atmospheric sensing device. It shall be used for heating wellventilated buildings used for animal rearing or for outdoor use only; Do not store chemicals or flammable materials or spray aerosols near this appliance. Do not operate this appliance in an explosive atmosphere like in areas where gasoline or other flammable liquids or vapors are stored; Do not place items on or against this appliance; Protect the hot glass tube from rain, water splash or anything that will cause a sudden change in temperature which may lead to cracking or shattering; WARNING Turn off the valve immediately if smell of gas is detected; Extinguish any open flame; If odour continues, contact your gas supplier immediately.

WARNING TABLE OF CONTENTS The user assumes all risk in assembly and operation of gas heater. Failure to follow the warnings and instructions in this manual can result in several personal injury, death, property damage. If user can not read or fully understand the instruction manual, please contact your dealer. Manufacturer or supplier will not be responsible for user's negligence. Caution 1 Heater Stand and Location 3 Gas Requirements 3 Leakage Test 4 Fuel Gas Odor 4 Operation and Storage 5 Assembly Instruction 6 Construction and Specifications 7 Assembly instructions 7 Problems Check List 11 Service and Maintenance Information 12

CAUTION PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE OPERATION Installation and repair should be done by a qualified service person. Improper installation, adjustment, alteration can cause personal injury or property damage. Do not attempt to alter the unit in any manner. This appliance must be installed and the gas cylinder stored in accordance with the regulations in force. Do not move the appliance when in operation. Shut off the valve at the gas cylinder or the regulator before moving the appliance. The tubing or the flexible hose must be changed each year. In case of violent wind particular attention must be taken against tilting of the appliance. Do not store or use gasoline or other flammable vapors or liquids into the heater unit. The whole gas system, hose regulator, pilot or burner should be inspected for leaks or damages before use. All leak tests should be done with a soap solution. Never use an open flame to check for leaks. Do not use the heater until all connections have been leak tested. Turn off immediately the gas valve if smell of gas is detected. Do not transport heater while its operating. Do not move the heater after it has been turned off until the temperature has cooled down. Keep the ventilation opening of the cylinder enclosure free and clear of debris. Do not paint radiant screen, control panel or top canopy reflector. Control compartment, burner and circulation air passageways of the heater must be kept clean. Frequent cleaning may be required as necessary. The LP tank should be turned off when the heater is not in use.. Check the heater immediately if any of the following exists: -The heater does not reach temperature. -The burner makes popping noise during use (a slight noise is normal when the burners extinguished). -Smell of gas in conjunction with extreme yellow tipping of the burner flames. The LP regulator/hose assembly must be located out of pathways where people may trip over it or in area where the hose will not subject to accidental damage. Any guard or other protective device removed for servicing the heater must be replaced before operating the heater. Change the gas cylinder in a well ventilated area, away from any inflammation source. Check that the regulator seal is fitted and that it is in good condition. Do not obstruct the ventilation holes of cylinder housing. Adults and children should stay from high temperature surface to avoid burns or clothing ignition. Children should be carefully carefully supervised when they are in the area of the heater. Clothing or other flammable materials should not be hung on the heater or placed on or near the heater. Use may replace the rubber hose by himself and note the length of the hose is 60cm. And the hose must be required by the national conditions. LP Characteristics-Flammable, explosive, heavier than air-settles in low areas. In its natural state, propane has no odor. For your safety, an odorant is added that smells like rotten cabbage. Contact with liquid LP can cause freeze burns to skin. This heater is shipped from the factory for LP gas use only Use only EEC approved 10KG Gas cylinders LP gas cylinders(same as commonly used on gas grills) with safety valves. These valves can be quickly identifies by their external and internal threads. When heater is not in use, turn Control Valve OFF. Close the valve of the gas cylinder or the regulator after use The use of this appliance in enclosed areas can be dangerous and is PROHIBITED. 1)For use outdoors or in amply ventilated areas. 2)An amply ventilated area must have minimum of 25% of the surface area open. 3)The surface area is the sum of the walls surface. - 1 - - 2 -

HEATER STAND AND OCATION The heater is primarily for outdoor use only. Always ensure that adequate fresh air ventilation is provided. Always maintain proper clearance to combustible materials, i.e. top 45cm (18") and sides 70cm (28'') minimum. Heater must be placed on level firm ground. Never operate heater in an explosive atmosphere like areas where gasoline or other flammable liquids or vapors are stored. LEAKAGE TEST Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness check must be performed at the installation site due to possible mishandling in shipment or excessive pressure being applied to the heater. The heater must be checked with a full cylinder. Make sure the safety control valve is in the OFF position. Make a soap solution of one part liquid detergent and one part water.the soap solution can. be applied with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak. Leakage test points. See pictures below. Turn the gas supply ON. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and recheck. Contact your dealer for assistance if bubbles continue to appear. Never leak test while smoking. GAS REQUIREMENTS Use LPG, propane and butane only. Maximum inlet pressure of propane regulator must not exceed 100 PSI. The pressure regulator and hose assembly to be used must conform to local standard codes. The installation must conform to local codes, or in the absence of codes, with the standard for storage and handling of liquid petroleum gases. A dented, rusted or damaged propane tank may be hazardous and should be checked by your tank supplier. Never use a propane tank with a damaged valve connection. The propane tank must be arranged to provide for vapor withdrawal from the operating cylinder. Never connect an unregulated propane tank to the heater. FUEL GAS ODOR LP gas and natural gas have manmade odorants added specifically for detection of fuel gas leaks. If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP)is!heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION. Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone. Get everyone out of the building and away from the area immediately. Propane (LP) gas is heavier than air and may settle in low area. When you have reason to suspect a propane leak, keep out of all low area. Use your neighbor's phone and call your fuel gas supplier and your fire department. Do not reenter the building or area. Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier. Finally, let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then relight the appliance for you. - 3 - - 4 -

OPERATION AND STORAGE TO TURN ON THE HEATER 1.Turn on the valve on the gas supply cylinder completely. 2.Push the control knob in it and turn it the pilot position. 3.Press the igniter button several times to light the burner. Hold it for 30 seconds. Components ASSEMBLY INSTRUCTION Note: If a new tank has just been connected, please allows at least on minute for the air in the gas pipeline to purge out through the pilot hole. When lighting the pilot flame make sure that the variable control knob is continuously pressed down while pressing the igniter button. Variable control knob can be released after the pilot flame lights. Pilot flame can be watched and checked from the small round window with sliding lid located at the bottom of the flame screen (to the left or right side of the controller). If the pilot flame does not light or it goes out, REPEAT STEP 3. A 5minutes complete shut off period is necessary before relighting. Turn the knob to LOW position for small flame. See picture of. Turn the knob to HI position for big flame. See picture of. TO TURN OFF THE HEATER 1.Press and turn the variable control knob to OFF position. 2.Turn off the valve on the gas supply cylinder completely. HARDWARE CONTENTS (shown actual size) Variable control knob Igniter STORAGE 1.Always close the gas valve of the gas cylinder after use or in case of a disturbance. 2.Remove the pressure controller and the hose. 3.Check the tightness of the gas valve and for damage. If you suspect a damage, have it changed by your gas dealer. 4.Never store liquid gas cylinder in a sub-terrain, or at places without adequate air ventilation. CLEANING AND CARE Wipe off powder coated surfaces with soft, moist rag. For lacquer surface, use suitable cleaners. Do not clean heater with cleaners that are combustible or corrosive. Remove debris from the burner to keep it clean and safe for use. - 5 - - 6 -

A.Construction and characteristics: Transportable terrace/garden heater with tank housing Casing in steel with powder-coating or stainless steel Soluble gas connections are equipped with metal clamp Stainless steel flame screen Heat emission from reflector 3. Slide two reflector panels together. Insert one bolt M5x10 (DD). On cap nut (CC) loosely. CC Cap nuts M5 x 12 B.Specifications For outdoor use only Uses propane or butane gas only Weight: Stainless steel model G.W. 20 kgs Powder coating model G.W. 22 kgs Height: 2150 mm including stand With CE certificate DD Bolt M5 x 10 x12 ASSEMBLY INSTRUCTIONS 1. Attach wheel assembly (PP) to base (E). Line up holes in wheel bracket with corresponding holes in base, insert M8x30 (BB) through holes, and finger tighten two M8 flange nuts (AA). Be sure that the wheel assembly is parallel to the base, and fully tighten bolts. 4. Slide reflector plate onto reflector panels. Insert one bolt M6x10(HH). Slide one washer φ6 over threaded end of bolt M6x10(HH) and screw on cap nut(ee) loosely. Repeat procedure to complete the assembly of all four sections. Fully tighten all of the bolts in the rolled edge. EE Cap nuts M6 x 1 FF Stator 1 x 1 AA M8 Flange nut x 2 GG Stator 2 HH Bolt M6x10 x1 x1 BB Bolt M8 x30 x 2 2.WARNING: Remove protective cover before assemble. NOTE: If necessary for proper alignment of reflector sections, loosen each bolt prior to further assembly and retighten after sections are aligned. 5. Attach flame screen(b) to the groupware of burner unit (C). Line up the holes in screen bracket with corresponding holes in burner unit. Insert bolt 3/16"(II) through holes and finger fighten. Be sure that the screen assembly (B) is parallel to the burner unit and fully tighten bolts. I I Bolt 3/16-24 x 4-7 - - 8 -

6. Attach 4 washers(kk) onto the top of screen and insert 4 reflector spacers(jj) and hand tightened. JJ Reflector spacer x 4 KK Washer x 4 9. Attach regulator to gas line and tank. Fit the gas regulator rubber hose with the end thread of inlet gas steel pipe and tighten the nut. Connect the regulator with the LPG gas tank in counterclockwise direction and tighten it by adjustable wrench. Put LPG gas tank into stand. 7. Attach 4 washers(kk) to the top of 4 spacers and put the reflector onto the 4reflcector spacers. Make sure each washer is inserted well. Then attach 4 washers(kk) on the top of reflector and put 4 wing nut(ll) to the spacer and tightened. KK Washer x 4 LL Wing nut x4 8. Attach cylinder housing (D) to base. Attach cylinder housing loosely to base with four M6x10 screws (TT). Assembly of groupware of burner unit. Attach the housing lid onto the top of tank housing(d). Make sure the holes on the lid are corresponded to the holes on the housing. Insert 4 M5x10 (MM) bolts to the holes and hand tighten by 4 flange nut M8 (NN) make sure the lid assembly is paralled to the base, and fully tighten bolts. Do not store a spare LP-gas cylinder under or near this appliance; Never fill the cylinder beyond 80 percent full; Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. only install the type of dust cap on the cylinder valve that is provided with the cylinder valve. Other type of caps or plugs may result in leakage of propane. MM Bolt M5 x 10 x 4 NN Flange nut M8 TT Bolt M6 x 10 x4 x4-9 - - 10 -

Powered by TCPDF (www.tcpdf.org) PROBLEMS CHECK LIST Service and Maintenance Information PROBLEMS PROBABLE CAUSES Gas valve may be FF Tank fuel empty SOLUTIONS Turn the gas valve ON Refill LPG tank If the pilot heater fails to operate correctly, contact place of purchase or their authorised service agent for advice and service. DO NOT ATTEMPT REPAIRS YOURSELF. Pilot will not light Opening blocked Air in supply system Loose connection Debris around pilot Clean or replace opening Purge air from lines Check all fittings Clean dirty area Periodic maintenance should performed at intervals not exceeding 6 months or when obvious faults exist. (i.e.) flame burning abnormality or burner discolouration. Flame abnormality or burner discoloujration is generally a sign of gas supply blockage or blocked burner ports. Pilot will not stay on Loose connections Thermocouple bad Gas leak in line Lack of fuel pressure Pressure is low Opening blocked Tighten connections Replace thermocouple Check connections Tank near empty. Refill LPG tank. Tank near empty. Refill LPG tank. Remove and clean To clean the burner ports,remove the reflector assembly by removing the three nuts at the top of the reflector.the mesh screen may than be extracted by removing the four retention screws at the base of the mesh screen and four screws at the top of the screen. Remove the two screws retaining the burner assembly,rotate the burner assembly slightly then remove the bunner assembly upwards. Burner will not light Control not on Thermocouple bad Pilot light assembly bent Not in correct location Turn valve to ON Replace thermocouple Place pilot properly Position properly and retry Care should always be taken to avoid damage to the gas piping and Piezo ignition lead. The burner and mesh screen may than be cleaned by compressed air. Assembly is a reversal of the above procedure. If the pilot is blocked by debris,spider webs etc. the pilot flame may be small and the flame failure device may have not heated up enough for the main burner to come on. If this happens it will be necessary to clean the pilot and its gas tube. To clean the pilot, remove the burner and pilot cover as detailed above,inspect the pilot injector and tubing for blockage.if obstructed dean with compressed air.ciean the flame failure device. Assembly is a reversal of the above procedure. - 11 - - 12 -