SPECIFICATIONS OM- ARA- NET OM- ARA- TF CONTROLLER OM- ARA- NET OM- ARA- TF CONTROLLER OPTICAL FIBER NET INTRUSION DETECTION SYSTEM
Intrusion Detection Optical Fiber Net Diamond shape fiber optic NET has been made from heavy duty military tactical outdoor fiber single mode, KEVLAR reinforced. This fiber is acting as a continuous sensor so that if there were any attempt of climbing, crawling and breaking of NET the intrusion alarm will be raised. To give more stable operation, this fiber optic net is designed to be unaffected by weather, harsh environments, corrosion or UV radiation. Easy installations and maintenance are one of the key features of this Diamond Shape Optical Fiber NET Heavy Duty Military Spec Tactical Fiber Kevlar reinforced polyurethane Jacket No Metal Components Resistible to harsh environment I Corrosion I UV radiation Resistible to bad weather condition : Rain, Snow, Strong Winds No effects from Lightning, Electrostatic/Electromagnetic interference Total immunity from any attempt to bypass, bridge or tapping by intruders Non-Flamable
S0 meter 0.5~3m COMMON SPECIFICATION MODEL (LX-ARA-NET0-40 70-40 85 OM-ARA-NET Height x Length ex) OM-ARA-NET -
Intrusion Detection Triggering Fixtures For the complete intrusion detection, upper and lower trigger units will be installed together with optical fiber net. Upper trigger would be installed into existing Y-type picket of the fence or block wall to support optical fiber net and to detect intrusion action. Lower trigger can be installed at the bottom of fiber optic NET. When the intruder is attempting to climb or lifting for crawling, The upper and lower trigger will activate to alarm the intrusion. In the sensing area, only optical fiber and mechanical triggering device is used to be immune to noise, radio frequencies, electromagnetic or electrostatic fields even lighting and thunderstorms. Upper Trigger: LX-ARA-TFU Upper Trigger alarm action : Vertical pushing/pulling Horizontal pushing/pulling Climbing with NET Lower Trigger : LX-ARA-TFL Lower Trigger alarm action : Lifting the NET Can be installed in existing fence. Customization always welcomed. No additional electricity required.
Upper Trigger: 31.5 x2.4 x2.4 (inch) (Center Position, Trigger only) Lower Trigger: 5.7 x3.5 x1.3 (inch) 8.3 5.7 1.3 3.3 Upper Trigger (for example) Y-Picket Lower Trigger Block Wall Model (OMNI-ARA-TFU/TFL) Common Specification Upper Trigger: OM-ARA-TFU-opting (Type of Y-picket to be installed) Lower Trigger: OM-ARA-TFU-opting (Type of fence to be installed)
Intrusion Detection Controller OM-ARA Series (Rack Type Intrusion Detection Controller) is the new generation of intelligent measurement for the intrusion detection for fiber optic sensor net system. OM-ARA is specially designed for intrusion detection with optical fiber NET application with its economics and also with outstanding performance. OM-ARA Series is manufactured with patience and carefulness, following the international standards to combine the rich experience and state-of-the-art technology, subject to stringent mechanical, electric and optical testing, quality assurance, our new design makes OM-ARA series more smart and compact. Whether you want to detect link layer in the security fields and installation of optical network or proceed efficient maintenance and trouble shooting, OMNI-ARA Series can be your best assistant. 24 hours, 365 days reliable operation Fast real time detection Dual power supply supplied for reliable operation Hot pluggable for controller cards, fans and power supply modules 4-ports and 16-ports per controller card operation for cost management LC/APC optical connector used to provide low reflection connection Suitable to detect fiber cut, fence opening, fence movement, crossing over fence and etc
3.5 19 15 3.5 19 (inch) Model (OM-ARA Series) Common Specification 6 miles -10-40 100 60 85 240 Interface Specification Ordering Information OM-ARA-SH : Shelf OM-ARA-PSU: Power Supply Unit Cards OM-ARA-4P : 4-Ports Controller Cards OM-ARA-16P : 16-Ports Controller Cards
Military proven by ROKArmy/Navy/Air-Force High detection rate (Over 99%. Without Jump Over) Virtually no false alarm Detection point accuracy within ±3 meters in perimeter length for the case of detection in optical fiber NET Diamond shape optical fiber net OTDR based detection system Easy installation and maintenance Optical fiber cut Attempt of breaking the NET Attempt of climbing the NET Attempt of climbing with upper-trigger horizontal and vertical pushing/pulling Attempt of lifting for crawling underneath ROK Army has chosen OMNI Security's intrusion detection system known as "Fiber Hunter'' based on OTDR technology since 2014. It has been installed in GOP area between the borders of North and South Korea where the most acute situation in the world. Additionally ROK Navy and Airforce have chosen fiber optic NET perimeter intrusion detection system "Fiber Hunter'' to be installed in where they requires the most reinforced reliable un-manned perimeter intrusion detection systems like air-force bases, naval bases, ammunition depots, satellite stations, and etc. High detection rate with ultra-low false alarm and easy maintenance are the key features for un-manned perimeter system which "Fiber Hunter'' has and as well as the pin point accuracy indication for intrusion detection point in the perimeter within ± 3 meters for the case of detection in optical fiber NET.
Main elements of "Fiber Hunter" "Fiber Hunter'' Optical Fiber NET Diamond shape fiber optic NET has been made of heavy duty military tactical outdoor fiber, single mode, KEVLAR reinforced. This fiber acts like a continuous sensor so that if there were any attempts of climbing, crawling and breaking the NET the intrusion alarm will be raised. To give more stable operation, this fiber optic net is designed to be unaffected by weather, harsh environments, corrosion or UV radiation. Easy installations and maintenance are one of the key features. Optical Fiber Net "Fiber Hunter'' Triggering Fixtures For the complete intrusion detection, upper and lower trigger units will be installed together with optical fiber net. Upper trigger would be installed into existing Y-type picket of the fence or block wall to support optical fiber net and to detect intrusion action. Lower trigger can be installed at the bottom of fiber optic NET.When intruders are attempting to climb or lifting for crawling, upper and lower trigger will act to alarm the intrusion. In the sensing area, only optical fiber and mechanical triggering device is used to be immune to noise, radio frequencies, electromagnetic or electrostatic fields even lighting and thunderstorms. Triggering Fixture "Fiber Hunter'' Detection System OTDR based detection system is directly connected to the optical fiber installed in perimeters. This detection system can be installed in central office or outdoor cabinet with climate control(mostly heater). In one shelf of the detection system with 2U height, up-to 4 detection cards consisted with 4- optical port or up-to 2 detection cards consisted with 16-optical port can be installed. For standard installation, length of 50 m fiber optic net will be installed for each optical port of the detection card. The detection system is connected with Ethernet line to the server which the Detection software is installed. Triggering Fixture "Fiber Hunter'' Detection Software This software is designed to detect any intrusion action in all environmental situation. Depending on the environmental situation of the optical fiber net installed, false alarm might be generated, but with the software parameter changes, false alarm can be eliminated virtually for all environmental situations like sand/snow storm, typhoon, microburst, sudden temperature changes and etc. Easy to use GUI-based software will give best way of intrusion detection, system diagnostics, finding fault point for maintenance, and system report for operation. Pin-point detection accuracy of ±3m in perimeter length in optical fiber NET, detection can be achieved to have best perimeter protections. Intrusion alarm information can be transferred to user's main system like CCTV surveillance system by Ethernet packet to be interlocked with.
Optical fiber net/upper-trigger/lower-trigger/optical fiber sensor cable Note : 1. Dimension of optical fiber net can be optimized depending on application. 2. Height of optical fiber net can be adjusted by cascading unit width vertically. Detection system is consisted with one or more shelves with PSU(Power Supply Unit) and detection card. Two PSU unit can be plugged into one shelf to support hot-pluggable dual power. Detection card is two-kinds. One is with 4-port, and the other is 16-port for detection. In standard configuration, each port can cover the length of 50 meter perimeter length. Each detection card is connected with 10/100 Ethernet connection to communicate with server where the detection software is installed. Detection system can be installed in outside cabinet with climate control or central-office. FIBER HUNTER CAN BE INSTALLED IN ANYWHERE