BEDIENUNGSANLEITUNG englisch Wasserenthärter Maxi Elegant VE

Similar documents
O P E R A T I N G M A N U A L

1850 Series TRIPLE TREAT Operation Manual

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Owner s Manual / 5600 Econominder

Owner's Manual. WS Series. Water Softener

Water Softener Installation Guide Effective for all Softeners from our Range

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

NovoSoft 465 Series SIM Water Softener Operation Manual

User Manual AF-30-VT

RUNLUCKY SHOWER SOFTENER SHOWER SOFTENER. User Manual. The appearance is just for reference. It is subject to the real product.

Autotrol Performa FA Valve

OWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters

SHOWER SOFTENER-CEASA 1

INSTALLATION GUIDE. soft duomatik evoline

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

Installation and Operation Manual

Plumbline 2000 Series Metered Softeners Owners Manual Water Softener Models

GRANT-DILLING-HARRIS INC. WATER SOFTENER THEORY OF OPERATION

Plumbline 1000 Series Timered Softeners Owners Manual Water Softener Models

INSTALLATION GUIDE. soft monomatik hotwater

What to expect from your water softener

BarAid 400. Installation and. Starting from Serial No.:

Metermatic Water Softener. Operation Manual

INSTALLATION GUIDE. soft duomatik evoline

6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.

MASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

2.0 HIGH CAPACITY SIMPLEX WATER SOFTENER INSTALLATION AND OPERATIONS MANUAL

Installation and Operations Manual

MP-MBA-45T-1/60T-1 / 75T-1

6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.

GETTING STARTED? EASY.

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Cabinet Non-Electric Water Softener

WATER SOFTENER MODEL 801 CODE

Record of System Specifications 2 Product Dimensions 3 Pre-Installation Checklist 4 System Installation 5-9 Installation Notice, Unit location,

Fleck 2510 Softener Installation & Start Up Guide

User Manual. Dishwasher IDSH604W

5900S Softener Installation & Start-Up Guide

6700XTR Valve Downflow

Glass and Dishwashers. BarAid 500/800. Installation and. Starting from Serial No.:

Glass and Dishwashers AMX / AUX Series

Fully Automatic Water Filters

ESF5202LOW. EN Dishwasher User Manual

User manual. Dishwasher ZDT15002

user manual Dishwasher ESL 46510

HX-30/40 and HX-30/40 S Glass and Dishwashers

PUROTAP easy. Installation Function Operation Service. fast efficient safe. Demineralised heating water perfect for every system

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

FLECK 5600 WATER SOFTENER INSTALLATION

Autotrol Brand Performa Valve / 400 Series Controls

GETTING STARTED? EASY.

FAVORIT34502VIO. EN User Manual

This product was manufactured in an ISO 9001:2000 certified facility.

User Manual Dishwasher F55412VI0

GETTING STARTED? EASY.

Glass and Dishwashers AMX / AUX Series

User Manual Dishwasher FAVORIT55311VI0

User manual. Dishwasher ZDI12001

Installation & Service Manual

Autotrol Performa Valve

MIX Boiler & Font Range Service Manual

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.

DUPLEX COMPACT. 11. CONNECTIONS (1/2",3/4, 1") BRINE VALVE 5. (floater)

RevV4 Valves & Systems Service Manual. Innovative Solutions for Your Water

ESL 5201LO EN DISHWASHER USER MANUAL

User manual. Dishwasher ZDTS102. Downloaded from manuals search engine

5700-E Sediment Filter Installation & Start-Up Guide

1. BYPASS 7. WATER OUTLET 2. VALVE HOUSING 8. BLENDING REGULATOR 3. RESIN TANK 9. HARDNESS REGULATOR 4. SALT BIN 10.

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

RIVERSOFT Water Softener System

User Manual Dishwasher FAVORIT 56302MO FAVORIT 56302WO

WS1 Softener Installation & Start-Up Guide

Autotrol Performa Valve

GETTING STARTED? EASY.

The Classeq under counter range

Carmen. Operating Instructions. 1

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

Clean Water Made Easy

Waste water ejection unit

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

Autotrol Brand 255 Valve / 400 Series Controls

HD / HDL Valves & Systems Service Manual

GETTING STARTED? EASY.

Operating Instructions UniTech Perfect

565 TLC Softener & Tannins Reduction System

smardy - pure water Reverse osmosis system YR100-A 75 GPD

User Manual Dishwasher F55402VI0P

MODULAR AUTOMATIC GRANULAR ICE FLAKER

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

User manual. Dishwasher ZDT12041FA

Fleck 5600 Carbon Filter Installation & Start Up Guide

User s Manual. Purity In Each Drop. Latest RO+UV technology Now at your home

GETTING STARTED? EASY.

EVOLIO-560 Water Softener System

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

Owner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call

Transcription:

BEDIENUNGSANLEITUNG englisch Wasserenthärter Maxi Elegant VE KBS Gastrotechnik GmbH - Johannes-Kepler-Str. 14-55129 Mainz www.kbs-gastrotechnik.de Stand November 2018

U S E R M A N U A L AUTOMATIC WATER SOFTENER STATION MAXI ELEGANT VE Installer Stamp Date of Installation.. Serial Number. Please read the operating manual before startup! The manufacturer is not responsible for malfunctions caused by faulty operation and failure to comply with the provisions of this documentation. Store for later use! This operating manual is an integral part of the device. 1

Table of contents General instructions...3 Transportation and packaging... 3 Liability Exclusion... 3 How it works...4 Standards, provisions and statutory regulations...4 1. Description of the device...4 1.1 System structure...4 1.2 Technical description...5 1.3 Control function...6 2. Preparation for installation...6 2.1 Installation preparation plan...6 2.2 Dismantling and utilization... 6 3. Installation...7 3.1. Parameter enquiry...8 3.2. Programming device short version for the installer...8 3.3. Parameter settings programming the steering valve...9 4. Troubleshooting... 11 5. Spare parts... 17 6. Product card... 18 2

General instructions 1. The relevant installation and operation instructions contained in this manual must be read prior to the installation and operation of this device. 2. The manufacturer will not bear responsibility in case of improper use and incorrect operation of the device. 3. The system is used only for removing unwanted mineral substances, which accumulate as lime scale (Calcium and Magnesium). This device is a part of the system protection. 4. It is forbidden to make change in the system without consultation with the manufacturer. The manufacturer will not bear responsibility in case of any damage caused by this type of modification. 5. C 6. The general regulations and provisions as well as provisions concerning accident prevention must be observed at the installation location of the device. 7. The installation location of the device must be secured from any damage caused by water (e.g. by the existing floor drain). The manufacturer is not responsible for any damage caused by water. 8. The appliance in which the filter is used must be free of limescale and gypsum deposits prior to installation. 9. Do not assemble near sources of heat and open flames. 10. Protect the filter system from mechanical damage. 11. Installation and maintenance of the filter system may only be carried out by trained and authorised personnel. 12. For cleaning do not use any abrasive chemicals, cleaning solutions or astringent cleaning agents 13. The proper name and serial number of the device must be provided with any enquiries and ordering of spare parts. Only then an effective and quick reply or order implementation is ensured. Transportation and packaging Prior to shipment our systems are carefully packed and controlled. Damage during transportation cannot be excluded in case of shipment by a shipping company. It is necessary therefore to check the package at receipt of the product. 1. Check the completeness of the delivery based on the delivery receipt. 2. In case of damaged packaging: perform a visual inspection of the goods and record conclusions in the shipping documentation provided by the shipping company. Make photographic documentation of the damaged package and the device. In the shipping documentation place an annotation of possible claiming of hidden damages, which may be revealed after start-up. Immediately contact the shipping company because otherwise the shipping insurance will not be available. Save the package for the purpose of any later inspections by the shipping or insurance company. 3. In case of returning the package, it must be packed in a way to be protected against any mechanical damage. 4. Drain water from the system prior to the shipment. This will help reduce shipping costs. It will also prevent the packaging from damage due to potential water leakage. After storage and transport below 0 C, the product must be stored in the open original packaging for at least 24 hours before it is commissioned at the stated ambient temperatures for operation. Liability Exclusion Installation must be performed precisely in accordance with the instructions in this manual. Manufacturer shall not be held liable for any damage, including subsequent damage, arising from the incorrect installation or use of the product. 3

How it works Hard water contains the combination of calcium (Ca), magnesium (Mg) and iron (Fe). The softening process serves the removal of the positively charged ions by means of ion-exchanged resin. When the ion-exchanged resin loses its effectiveness it is regenerated by the reagent. Regeneration: The regeneration is based on rinsing the deposits using the tablet salt solution and rinsing out the absorbed calcium and magnesium ions into the sewage. Regeneration takes place automatically in an intelligent logical cycle. On the basis of the water use from the last 7 days the system itself chooses the day of regeneration at the pre-set time. During regeneration (60 min), hard water is available. Regeneration process consist of 4 cycles: 1. Backwashing ( 8 min.) 2. Brine and Slow Rinses ( 60 min) 3. Refilling ( 2MIN +/- 10 sec.) about 12,5 liter 4. Fast Rinsing ( 6 min) Standards, provisions and statutory regulations 1. Water supplying the device must comply with the requirements of the utility water use regulation. 2. Parts that are in contact with treated water must be made of material resistant to treated water, 3. In the room for the water treatment floor drainage must be installed. The purchaser is responsible to ensure the drainage. 4. Maximum temperature of the supply water is 40 C 1. Description of the device 1.1. System structure The system of water purification type Maxi Elegant VE is a device of high quality and precision. Properly installed and maintained guarantees infallible functioning for many years. The water softener station of small efficiency type Maxi Elegant VE is used where the water flow does not exceed 35l/m. System structure: 1. Water softener Type : Maxi Elegant VE 2. Drain hose ½ 1.2. Technical description Quantity of softened water for 10 o dh /regeneration [liters ] 9000 Salt Consumption [kg] 4,5 Flow Rate [l/min] 1,8-35 Operating pressure [bar] 2,0-6,0 Time of regeneration [min] 76 Connections [cal] ¾ Height [mm] 1140 Depth [mm] 510 Width [mm] 360 Maximum water temperature [ 0 C] 40 Salt storage capacity [kg] 75 4

The system is configured to use 4,5 kg of reagent per each regeneration. Calculating the amount of softened water between regenerations: The amount of water between regenerations is calculated according to this formula: Z = 9000x10/y Where Z is the amount of softened water between regenerations Y is the examined water hardness according to n (German degree) An example of calculation the amount of softened water z between regeneration. Data: the examined water hardness = 15 n The amount of z water between regenerations is calculated according to the formula: Z = 9000 x 10/15 = 6000 liters. At the water hardness of 15 GH we get 6000 liters of softened water. TAB. 1. CAPACITY Maxi Elegant VE Water hardness English degree French degree PPM German degree Efficiency Maxi Elegant VE 12,5 18 178,6 10 9000 13,8 19,8 196,5 11 8182 15 21,6 214,3 12 7500 16,3 23,4 232,2 13 6923 17,5 25,2 250 14 6429 18,8 27 267,9 15 6000 20 28,8 285,8 16 5625 21,3 30,6 303,6 17 5294 22,5 32,4 321,5 18 5000 23,8 34,2 339,3 19 4737 25 36 357,2 20 4500 26,3 37,8 375,1 21 4286 27,5 39,6 392,9 22 4091 28,8 41,4 410,8 23 3913 30 43,2 428,6 24 3750 31,3 45 446,5 25 3600 32,5 46,8 464,4 26 3462 33,8 48,6 482,2 27 3333 35 50,4 500,1 28 3214 36,3 52,2 517,9 29 3103 37,5 54 535,8 30 3000 38,8 55,8 553,7 31 2903 40 57,6 571,5 32 2813 41,3 59,4 589,4 33 2727 42,5 61,2 607,2 34 2647 43,8 63 625,1 35 2571 45 64,8 643 36 2500 46,3 66,6 660,8 37 2432 47,5 68,4 678,7 38 2368 48,8 70,2 696,5 39 2308 50 72 714,4 40 2250 The stated capacities were calculated based on standard application and machine conditions. This information may vary according to external influencing factors (for example, fluctuating raw water quality). 5

1.3. Control function Steering Valve Before launching the current time should be set and the number of m 3 to flow after which the regeneration is to start. Valve is pre-set for intelligent regeneration (down-flow) A-03 The drive is preset for the regeneration at 2 a.m. every 4500 liters (4,5 m 3 ) for the water hardness of 20 GH German degrees. Depending on the water hardness set the appropriate number of liters to flow after which the regeneration is to start and set the regeneration time. Control system (treated water hardness) If the soft water is set to a specified hardness level, higher than 1 dh, the bypass adjusting bolt must be properly opened (see figure on page 7). By turning a screwdriver counter clockwise increase the amount of tap water in the soft water. Check the water hardness in the regulated soft water. 2. Preparation for installation 2.1. Installation preparation plan Picture 1. On the purchaser s side: 1. Utility water supply pipe (cold) 3/4 with a cut off valve. 2. Drainage (sewer) at a max. height of 100 mm, connection DN 50. 3. Electric socket 230 V / 50 Hz, 16 A 4. Floor drainage must be in the room. 5. Sediment filter must be use before water softener 2.2. Dismantling and utilization The device is dismantled after it lifetime has expired (for final destruction or scrap). The reversed assembly steps are to be commenced. Note! First clean the system thoroughly with fresh water and drain the tanks and pipes completely! Comply with workplace safety instructions in this respect! Different parts of the device must be utilized in accordance with binding regulations of utilization and waste management! 6

3. Installation After preparation for mounting, the device is to be placed in the designated room in accordance with the system structure. All inlets and outlets are to be connected on the water s side. The device connections are shown in the following figure: Connect the inlet (1) and outlet (2) to water supply; Connect the elastic pipe (1/2 ) draining the sewage to the stub connector pipe (3) and to a sewage grating or a draining installation. The sewage draining should be permeable enough to drain 5l/m of the flushing water. The draining pipe should be stiff enough to avoid its breaking, which may cause blockage and result in the overflow in the tank with the reagent as well as faulty regeneration process; Before water softener should be used mechanical sediment filter to protect device from mechanical damage caused by sediments from water pipes. The brine tank of the water softening device is to be filled with salt tablets (max. filling 100 mm from the upper edge of the brine tank). Next add 5 liters of water using buckets. Check and tighten all fittings connecting the device. Connect to electric Power socket. The device is factory adjusted. The fine tuning is done by the user on site. Program the steering valve (see point 3.2) Before launching the current time should be set and the number of m 3 to flow after which the regeneration is to start. Valve is pre-set for intelligent regeneration (down-flow) A-03 (description on page 11) The Valve is preset for the regeneration at 2 a.m. every 4500 liters (4,5 m 3 ) for the water hardness of 20 GH German degrees. Depending on the water hardness set the appropriate number of liters to flow after which the regeneration is to start (Examine the water hardness and use the table from the page 5) and set the regeneration time. Open the water supply to the water softening device. The water pressure must be at least 2,0 bars and a maximum of 6,0 bars. Initiate regeneration by pressing button You will hear the humming of an electric engine, which means that device driver has started its regeneration. During the regeneration process the system deaerates and refills the reagent tank with water. Once the regeneration is over, the device is ready to work again. During the regeneration hard water is available. While programming it is not allowed to change : Backwash, Brine and Slow Rinse, Refilling and Fast Rinsing settings in the Advanced Settings stage. These are the manufacturing settings for the MaxiElegant VE system; in case they are changed the system will not work properly and manufacturer shall not be held liable for the consequence of incorrect operation of the system. The system has been programmed in A-03 regeneration mode the intelligent, logical regeneration. On the basis of the water use from the last 7 days the system itself chooses the day of regeneration at the pre-set time. Picture 2. Steering valve description. 1. Inlet of raw water (3/4", elastic connection) 2. Outlet of treated water (3/4", elastic connection) 3. Drain (1/2", elastic connection). 4. 3/8" brine tank connection 5. Flow meter insert 7

Picture 3. PC BOARD DISCRIPTION Unlock the keypad If the symbol is displayed on screen, the buttons are locked. To unlock the keypad press and hold both and for 5 seconds, after that the light is off. To enter the setting mode press button 3.1. Parameter Enquiry Set 12/24h Clock Choose 12Hr Or 24 Hr Set Work Mode Adjust Work Mode Set Clock Set the time Set Recharge Time Adjust Recharge Time Water Used Today Display Water Used Today Set Residual Water Adjust Water Treatment Capacity Average Water Used Display Average Water Used Set Interval/Wash Set Repeat-Washing Adjust Interval Backwash Time Adjust Repeat Washing Time Set Gal./L/m 3 Choose the unit Set Backwash Time Adjust Backwash Time Advanced Settings Set Brine & Rinse Adjust Brine & Slow Rinse Time Set Brine Refill Adjust Brine Refill Time Set Fast Rinse Adjust Fast Rinse Time Set Max Days/Rchg Adjust Max Recharge Days 3.2. Programming device short version for the installer To program the device must be entered - The current time -regeneration hour -system efficiency Unlock the keypad by pressing and holding both and for 5 seconds. Press button, and use or to reach Set Clock (the current time), press button, and by using and buttons set the current time. To confirm and save Press button Next go to the step Adwanced Settings, press button to get into the options. By using and buttons reach Set Recharge Time (regeneration hour), press button and by using and buttons set the regeneration hour. To confirm and save press button Next go to the step Set Residual Water (system efficiency), press button to get into the option and by using and buttons set the system efficiency (in liters) use the table from the page 5. To confirm and save press button. Leave the programming by pressing button twice. 8

3.3. Parameter Settings PROGRAMMING THE STEERING VALVE In program display mode, press or to adjust the value. The steps of parameter setting to be set No. : 1, 2, 6 No. Action Item Process Step Symbol 1 To Be Set Set 12/24 When Light is on, press and until the light off. Hr Clock 1.Press to enter the setting interface. The option of Set 12/24 Hr Clock will be selected by system automatically. 2.Then press right figure., the setting interface will display as the 3.Through or to choose 12Hr or 24Hr. 4. Lastly, press and hear a sound Di, then finish adjustment 2 To Be Set Set Clock 1.In setting status, press or to select Set Clock. 3 Pre Set : L DO NOT CHANGE 2.Press, the setting interface will display as the right figure. Then press or to set the hour, press to move for minutes and press or to set the minutes. 3. Lastly, press and hear a sound Di, then finish adjustment Set Gal./ L /m 3 DO NOT CHANGE!!! 4 Pre Set A-03 (Intelligent Down Flow). DO NOT CHANGE 5 Pre Set : Regenerati on at 02:00 am. Can be changed 6 Pre Set : 4500 L for Water Hardness 20 o GH To Be Set 7 DO NOT CHANGE Work Mode DO NOT CHANGE!!! Recharge Time Water Treatment Capacity Interval Backwash Times 1.In advanced setting status, press or to select Set Recharge Time 2.Press, the setting interface will display as the right figure. Then press or to set the hour, press to move for minutes and press or to set the minutes. 3. Lastly, press and hear a sound Di, then finish adjustment 1.In advanced setting status, press or to select Set Residual Water 2. Press, the water treatment capacity setting will display as the right figure. Then press or to set residual water. 3. Lastly, press and hear a sound Di, then finish adjustment DO NOT CHANGE!!! MaxiElegant VE is preset for Intelligent regeneration Down FLOW Examine water hardness and set appropriate value 8 DO NOT CHANGE Repeat Washing Times DO NOT CHANGE!!! 9

9 DO NOT CHANGE!! Backwash Time DO NOT CHANGE!!! 10 DO NOT CHANGE!! Brine & Slow Rinse Time DO NOT CHANGE!!! DO NOT CHANGE!! BACKWASH TIME FOR MaxiElegant VE IS 08:00 11 DO NOT CHANGE!! 12 DO NOT CHANGE!! Brine Refill Time Fast Rinse Time DO NOT CHANGE!!! NOTE: Too long time to fill the brine tank can cause overflow of water into the sewage system or outside of the device. The supplier is not liable for damages resulting from wrong setting of this parameter. DO NOT CHANGE!!! DO NOT CHANGE!! BRINE&SLOW RINSE TIME FOR MaxiElegant VE IS 60:00 DO NOT CHANGE!! BRINE REFILL TIME FOR MaxiElegant VE: 02:00-(+/- 10sec.) about 12,5 liter 13 Pre Set 30 days. Can be changed 14 Pre Set : English Language. Can be changed Max Days Between Recharges Language Change 1.In advanced setting status, press or to select Set Max Days.Rchg 2.Press, max days between recharges setting will display as the right figure. Then press or to adjust the max days period between regeneration. 3. Lastly, press and hear a sound Di, then finish adjustment 1. Right after plugging the valve to power supply press both and buttons and hold for 5 seconds until on the screen language change will appears. 2. Then press or to adjust the language 3. Lastly, press and hear a sound Di, then finish adjustment DO NOT CHANGE!! FAST RINSE TIME FOR MaxiElegant VE IS 06:00 Language available: English, Spanish, Chinese, Russian, French, Italian, German, 10

4. Troubleshooting Problem Cause Solution 1. Softener is pouring water through the overflow (on the side of the softener) to drain during regeneration 2.Water is pouring through the top cover of the brine tank during regeneration 3. Water is pouring through the top cover of the brine tank during softener work (not during the regeneration) 4. Regeneration does not start automatically, but starts after manual The drain is clogged. Softener instead of sucking brine during the "Brine" cycle, is pouring water into the tank with the salt. Then the brine is pouring through the overflow on the side of the softener Leakage between the brine valve (air check) and the steering valve -Check the drain hose. If it is bent, collapsed broken or clogged, remove the hose from the drain pipe check if nothing is blocking it. Clean the drainage, if necessary, replace the hose - Make sure nothing is blocking the sewage pipe, clean the drainage Check the connections between the brine valve (air check) and steering valve. Remove the hose connecting the steering valve from the brine valve(air check) and check if steering valve sucks the brine during the Brine Slow Rinse cycle Clogged restrictor DLFC Clean the DLFC restrictor (see picture 5 page 18) The device does not suck the brine See problem nr 11 The device does not suck the brine Improperly connected softener Check the softener connections. IN raw water inlet, OUT Too long time of refilling the water in the brine tank Power failure during the filling of the brine tank Drain outlet from the steering valve is connected to the overflow on the side of the softener. Water during regeneration pours by the overflow (on the side of the softener) to the brine tank Water from the sewage system goes back and poured through the overflow (on the side of the softener) to the brine tank Resin tank leakage Steering valve pours water into the brine tank very slowly, there was an internal leak in the steering valve, probably scratched, damaged fixed disk (see page 18 - fixed disk - MJ3) Leakage from the connections (not tightened hoses for raw supplying water and treated water) Insufficient water flow through the device, less than 1.8 l / min. Water meter does not recognize the water flow. Water meter blades do not rotate. treated water outlet (see picture 2 page 7) Set correct time of refilling the water in brine tank - parameter : Brine Refill (see page 4) Check power supply Provide the drain hose separate from steering valve and the overflow on the side of the brine tank. Provide drain for overflow below the overflow elbow and the air gap between the drain pipe and the drain hose (see picture 1 page 6) Provide drain for overflow below the overflow elbow and the air gap between the drain pipe and the drain hose (see picture 1 page 6) Check the tank for leaks Replace the fixed disk (see page 18 - fixed disk - MJ3) Check the connections (inlet and outlet) for leaks Enter the programming and set the regeneration at every specified number of days (time mode) 11

initiation The meter does not count the water flow Clear turbine (impeller) of the water meter, check the operation of the water meter, replace the water meter if necessary. The water meter cable disconnected Connect the water meter cable to slot (see picture 4 page 18) 5. Regeneration does not start automatically, and does not starts after manual initiation 6. Water softener provides hard water but there is less and less salt in brine tank The steering valve programming incorrectly Enter the programming and set the days of regeneration (at set time option) or contact a specialist to correct set the control valve settings No power supply or faulty electrical power Check electrical connections - fuses, plug, switch. If necessary, regenerate the device manually Damaged engine Replace engine Damaged control board Replace the control board Water test has been made by the device Test the water hardness by device dedicated to test total dedicated to test KH (carbonate hardness) hardness of water GH Too little water in the brine tank Check the setting : time of water filling to the brine tank (see page 4), set properly and regenerate immediate by pressing the regeneration button. After regeneration check the amount of water in the brine tank (there should be about 2-3 liters) Improperly connected softener Check the softener connections. IN raw water inlet, OUT treated water outlet (see picture 2 page 7) The control valve does not draw brine Softener during regeneration No salt in brine tank or not enough salt in brine tank The drain is clogged. Softener instead of sucking brine during the "Brine" cycle, is pouring water into the tank with the salt. Then the brine is pouring through the overflow on the side of the softener Clogged restrictor DLFC - the device does not draw brine, while pouring water into the brine tank (water level at the height of the overflow elbow) See the problem 11 - the device does not suck (draws) brine (dirty injector Contact a specialist or clean the injector) Wait until the regeneration ends Prepare a brine solution in a bucket (about 1.5 kg of salt per 6 liters of hot water and mix to dissolve in). Pour the brine into the brine tank and manually start the regeneration. If water after regeneration is still hard, replace the resin. Refill the salt in the brine tank after regeneration. Salt level in the brine tank should always be above the water level -Check the drain hose. If it is bent, collapsed broken or clogged, remove the hose from the drain pipe. Check if nothing is blocking it. Clean the drainage, if necessary, replace the hose - Make sure nothing is blocking the sewage pipe, clean the drainage Clean the DLFC restrictor (see picture 5 page 18) 12

7. Water softener provides hard water The salt level is the same in brine tank (slat level does not decrease) The decrease in ion exchange capacity of the Replace the resin resin The resin loss See problem 14 Resin loss A leak in the central pipe Check if the central pipe (distribution pipe) is well set, not cracked, or flattened (due to using hot water in softener) Resin is exhausted because of too much Softener is too small for such a large water consumption. water consumption Change the softener for a larger one or increase the frequency of regeneration - for time-controlled mode Incorrectly set softener performance (water Examine the GH general hardness of water and re-set the treatment capacity) softener performance (use the tab. Softener capacity from page 5) Salt has caked, swelled up and is suspended Break down manually caked salt. Prepare a brine solution in over the water level in the brine tank a bucket (about 1.5 kg of salt per 6 liters of hot water and mix to dissolve in). Pour the brine into the brine tank and manually start the regeneration. If water after regeneration is still hard, replace the resin. Refill the salt in the brine tank after regeneration. Salt level in the brine tank should always be above the water level Improperly connected softener Check the softener connections. IN raw water inlet, OUT treated water outlet (see picture 2 page 7) Softener does not start regeneration See problem 4 & 5 Regeneration does not start automatically The water meter cable disconnected Connect the water meter cable to slot (see picture 4 page 18) 8. Water softener supplies not completely softened water 9. Excessive salt consumption The meter does not count the water flow The control valve does not fill the brine tank with water Open bypass Lack of power during regeneration Lack of water during regeneration or not enough water during regeneration Amount of salt in the brine tank is too small Water mixer is open See problem 6,7 Water softener provides Hard water Too much water in the brine tank Clear turbine of the water meter, check the operation of the water meter, replace the water meter if necessary See problem 12 The control valve does not fill the brine tank with water Close bypass Provide the electric power supply during regeneration Provide water under proper pressure ( 2,0-6,0 bar) during regeneration Pour salt to the level ¾ of the brine tank (cabinet). The amount of salt in the brine tank should always be above the water level. Change the water mixer position (water bypass adjustment bolt page 7 picture 2) See problem 6,7 Water softener provides Hard water Reduce time of filling the water to brine tank, see problem 10 "too much water in the brine tank" 13

10. Too much water in the brine tank. Amount of water in the brine tank reach the level of the overflow elbow Too frequent regeneration Examine the hardness of the water and set the efficiency softener (use the tab. Softener capacity from page 5) Incorrect setting in the programming Set correct time of refilling the water in brine tank - parameter : Brine Refill (see page 4) The device does not draw brine See problem 11 The device does not draw brine Drain is clogged or blocked -Check the drain hose if it is bent, collapsed, broken or clogged. Remove the hose from the drain pipe. Check if nothing is blocking it. Clean the drainage, if necessary, replace the hose - Make sure nothing is blocking the sewage pipe, clean the drainage Too long time of refilling the water in brine Set correct time of refilling the water in brine tank - tank parameter : Brine Refill (see page 4) Leakage between the brine valve (air check) Check the connections between the brine valve (air check) and the steering valve and steering valve. Remove the hose connecting the steering valve from the brine valve and check if valve sucks the brine during the Brine Slow Rinse cycle Power failure during refilling water in the Check power supply brine tank Improperly connected softener Check the softener connections. IN raw water inlet, OUT treated water outlet (see picture 2 page 7) Resin tank leakage Check the tank for leaks Steering valve pours water into the brine tank Replace the fixed disk (see page 18 - fixed disk - MJ3) very slowly, there was an internal leak in the steering valve, probably scratched, damaged fixed disk (see page 18 - fixed disk - MJ3) Clogged restrictor DLFC Clean the DLFC restrictor (see picture 5 page 18) Water from the sewage system goes back and pours through the overflow (on the side of the softener) to the brine tank Provide drain for overflow below the overflow elbow and the air gap between the drain pipe and the drain hose (see picture 1 page 6) 11. The device does not draw brine Leakage from the connections (not tightened Check the connections (inlet and outlet) for leaks hoses for raw supplying water and treated water) Blocked or damaged injector Clean or replace the injector see page 18 Leakage between the brine valve (air check) Check the connections between the brine valve (air check) and the steering valve and steering valve. Remove the hose connecting the steering valve from the brine valve and check if valve sucks the brine during the Brine Slow Rinse cycle Too low pressure in the water mains Increase water pressure at the inlet to the water softener to a minimum of 2,0 bar. 14

Blocked hose or a brine valve (air chek) supplying brine to the driver Cracked ball in the brine valve (air check) The drain is clogged. Lack of water in the brine tank 12. The steering Time of filling the brine tank with water valve does not fill "Brine REFIL", is set incorrectly the brine tank with water 13. Water pressure The precipitate of iron in the softener drop Limescale or blockage in water system Entrance to control valve contaminated with the rest of the installation works Contaminated pre-filter Installation pipe or hose supplying / drainage water softener is too small diameter Air in the system 14. Loss of resin Water with too high temperature got into the softener Damaged upper basket, lower basket or distributor Check a brine hose and remove any lock impeding the flow Replace the brine valve (air check) -Check the drain hose. If it is bent, collapsed broken or clogged, remove the hose from the drain pipe check if nothing is blocking it. Clean the drainage, if necessary, replace the hose - Make sure nothing is blocking the sewage pipe, clean the drainage See problem 12 Steering Valve does not fill brine tank with water Enter the programming and set the correct time of filling the brine tank "Brine REFIL" Clean the control valve and the resin. Increase frequency of regeneration and / or duration of the backwash Check whether the settlement from the water did not block the water system before the device Remove all contamination and clean driver Clean or replace the filter Insert installation pipes or hoses with larger cross-section Check the installation and make sure that the brine is in the brine tank Remove the control valve and check the distribution pipe (central pipe), the upper basket, lower basket, if necessary, replace. Replace upper basket, lower basket or distributor 15. Continuous leakage into sewage systems from control valve Foreign bodies in the valve Lack of power during regeneration There was an internal leak in the steering valve, probably scratched, damaged fixed disk (see page 18 - fixed disk - MJ3) Check the inside of the valve, remove impurities and check the operation of the valve in different regeneration positions Check the power supply. Regeneration will be complete when the power turns on. In case there is no possibility to turn power on close the water supply to the machine until the resumption of power supply. Replace the fixed disk (see page 18 - fixed disk - MJ3) 15

16. Regeneration takes place at the wrong time Damaged motor Faulty power adapter Incorrectly set regeneration time Incorrectly set time of the day Replace motor Replace power adapter Enter the program and set the proper regeneration time (factory setting: at 2 am) Set the current time of the day 17. Interrupted Or irregular brine 18. Salt taste of soften water Lack of power supply period longer than 3 Set the current time of the day days Water pressure too low Or not stable Increase water pressure Air in resin tank Check and find the reason Injector is plugged or faulty Clean or replace injector Too short a time brining or fast rinse Enter the programming and set the correct time of brining and fast rinse (see page 4) The air inside unit. The air enters the resin Check for leaks between the steering valve and the brine tank during the brine sucking valve (air check). Brine valve leaking - check for leaks, check the ball in the brine valve if it close valve tightly after completely sucked from the brine tank. Ran out of water during regeneration, brine Manually initiate regeneration by pressing and holding the got into the tank of the resin but was not Regen button. This will allow the correct re-regeneration washed out of it Clogged drains, too small hose to drain Clean outflow into drains, and DLFC restrictor (see picture 5 page 18) Water pressure drop or not enough water Manually initiate regeneration by pressing and holding the during regeneration Regen button. This will allow the correct re-regeneration 19. Water flow out from drain Or brine pipe after regeneration 20. Water softener efficiency decreased after few months Or years Foreign material in valve which unable closing the valve completely Water pressure is to high which result in valve doesn t get the right position Regeneration performed incorrectly Frequent absence of salt or too little salt in the brine tank Contaminated resin Incorrectly set softener efficiency Increase the hardness of the water before the softener Clean valve, remove the foreign material from the valve Reduce water pressure Check the settings of regeneration cycles. Set the settings of regeneration cycles correctly and then replace the resin. Replace the resin and make sure that the amount of salt in the brine tank will never be below the water level Replace the resin Examine water hardness and program the efficiency softener (see table 1 page 5) If there is no improvement, replace the resin for new Examine water hardness and program the efficiency softener (see table 1 page 5) 21. Control valve Foreign materials stuck in the driving gear Take out foreign material If there is no improvement, replace the resin bed for new 16

cycle continuously Time of regeneration steps were set to zero Check program setting and reset 22. No screen display Controller is faulty No power at the socket Power adapter is not plugged to the socket or electrical wire is not plugged to the wire for power outbound from the steering valve. Incorrect supply voltage Faulty power adapter Damaged display board Replace the controller Repair damaged or use working socket Put the Power adapter to the electrical socket and to the steering valve in the appropriate slot Connect the power supply of the correct voltage Replace power adapter Replace display board Picture 4. Flow meter connection Picture 5. Control Valve parts 5. Spare parts list Spare parts from the valve: Description Spare Part No. Impeller MJ 1 Nozzle, Injector MJ 2 Fixed Disk MJ 3 Probe Wire (for flow meter) MJ 4 Control Board MJ 5 Display Board MJ 6 Locating Board MJ 7 Motor MJ 8 DLFC MJ 9 17

Product card MAXI ELEGANT VE PRODUCT CARD Date of installation Client s adress Tested water hardneess Estimated efficiency Date Salt tablets verified/supplemented Prefilter replaced Water hardness (utility water) Water hardness (pure water) 18