FDJ SERIES Jockey Pump Controllers Features

Similar documents
LMR Electric Fire Pump Controllers Features

FT60 Reduced Voltage - Autotransformer

LMR Electric Fire Pump Controllers Features

FDF Foam Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features

Transfer Switch Features

Transfer Switch Features

FD30 Full Voltage - Across the Line July 2011

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

Fire Pump Controllers Medium Voltage Controllers

Drawing Submittal Package

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Drawing Submittal Package

FT20 Full Voltage - Limited Service. Electrically and Mechanically

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

DIESEL Engine Fire Pump Controllers Features

Fire Pump Controllers Foam (Additive) Controllers

Soft Start Series MP700 Solid State, Reduced Voltage

Technical Data Submittal Document

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Across-the-Line SERIES MP300 Combined Manual and Automatic

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

TM Series. Induced Draft, Counter Flow Optional Accessories

Remote Alarm Panels Features

Paragon. Induced Draft, Counter Flow Optional Accessories

SECTION Fire Pumps

SECTION FIRE PUMP AND CONTROLS

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

Call us today! (800)

EATON LMR Plus Electric Fire Pump Controllers

Call us today! (800)

Technical Data Submittal Documents

CONTENTS AUTOMATIC TRANSFER SWITCHES

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

Gas and Electric Convection Ovens

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Call us today! (800)

Variable Frequency Drive SERIES MP800 VFD

EATON DFDAP-M / FDAP-M Remote Alarm Panels

Microprocessor Based Wye-Delta Reduced Current Type Starting

CR1 Series Triton Corrosion Resistant Washdown Heaters

PARAGON Commercial Refrigeration Controls

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

MD-170 Installation/Operator's Manual

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

Guide Specification Model CTG Automatic Transfer Switch

WCH5**4. Product Specifications

KIC Air Curtains. Technical Guide

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

SUBMITTAL SCHEDULE & DATA

.2 Section Waste Management and Disposal.

Even Baking Technology. Our latest technology ensures even baking every time. Hi /Lo Broil Option

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

MERIT SERIES Up Flow / Horizontal

Copy Right By: Thomas T.S. Wan

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

SECTION CENTRIFUGAL WATER CHILLERS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

SECTION ROTARY-SCREW WATER CHILLERS

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

MERIT Series R-410A - Upflow / Horizontal

Emery County Senior Center Green River 06/07

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

SECTION ENCLOSED CONTROLLERS

MERIT Series R-410A - Upflow / Horizontal

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

FTA550 JOCKEY PUMP CONTROLLERS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

PILOT SERIES MPT700TS

WALL-MOUNT HEAT PUMPS - (60HZ)

Large Capacity. Our large capacity oven gives you room to cook more at once. SpaceWise Expandable Element

SpaceWise Expandable Element. Flexible element expands to your cooking needs. Extra-Large Window

A. This Section includes transfer switches rated 600 V and less, including the following:

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

AD-410 Models AD-410 NON-TILT* 1 DOOR GAS MODEL AD-410 NON-TILT* 1 DOOR STEAM MODEL

FPEC3085K FFEF3015L S / M / W/ B

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Titan Optima &Titan Optima plus Swimming Pool Heater with Ultra Efficient Titanium Heating Elements

EUCCW SERIES. EUCCW4, EUCCW6 and EUCCW8 Upright 29 Conveyor Dual Rinse Dishwashing Machine. Champion, an Ali Group Company

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

2 shp 13 lc 1 36 t - 1 a

13 GEP A L P - 1 A

Transcription:

1-1 NEMA 2 Enclosures Enclosures have an oven baked powder paint finish and are supplied with NEMA 2 rating, unless otherwise ordered. Available options include: NEMA 1, 3R,, X, 12. Note: NEMA, X enclosures are Stainless Steel. NEMA Rated Operators EATON Cutler-Hammer NEMA rated 10250T Series oil and dust tight pushbutton operators are used in all jockey pump controllers. 120V Control Power Transformer All jockey pump controllers are wired with a 120V control power transformer as standard. Dual Setting Pressure Switch A dual setting 15-290 PSI pressure switch is used to sense a drop in pressure which actuates the jockey pump starter. The setting adjustment screws are used for setting the pressure range and differential. There is one set of form-c output contacts rated at 10 amps. Product Description ACROSS THE LINE JOCKEY PUMP CONTROLLERS The FDJP jockey pump controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single motor starter. Starting inrush current is approximately 600% of rated full load amperes. Technical Data ACROSS-THE-LINE (Direct On Line) JOCKEY PUMP CONTROLLERS 0-80V 550-600V 120V 1 ph 20V 1 ph Motor Horsepower 1/3-15Hp 1/3-20Hp 1/3-50Hp 1/3-50Hp 1/3-50Hp 1/3-5Hp 1/3-10Hp WYE-DELTA (Star-Delta) JOCKEY PUMP CONTROLLERS When six or twelve-lead delta connected jockey pump motors are started wye (star) connected, approximately 58% of line voltage is applied to each winding. The motor develops 33% of full-voltage starting torque and draws 33% of normal locked-rotor current from the line. After a 2 second time delay (during which the motor accelerates), it is reconnected for normal operation. Product Circuit Breaker Disconnect WYE-DELTA (Star-Delta) JOCKEY PUMP CONTROLLERS Motor Horsepower 0-80V 550-600V 1/3-15Hp 1/3-20Hp 1/3-50Hp 1/3-50Hp 1/3-50Hp (0.25-11KW) (0.25-30KW) (0.25-37KW) (0.25-37KW) (0.25-37KW) All jockey pump controllers are supplied with EATON Cutler-Hammer HMCP circuit breakers as standard. Standards & Certification The FDJ Series of s meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, the Canadian Standards Association and New York City building code. Safety Door Interlock The circuit breaker handle mechanisms are equipped with a safety door interlock which does not allow the controller door to be opened when the mechanism is in the ON position.

1-2 Dimensions Standard Enclosure - Type NEMA 2, 12 Motor Hp 0.33-15 0.33-20 0.33-5 0.33-10 0-80V 550-600V 120V 1 20V 1 Withstand Rating Standard Intermediate High 150,000 200,000 0 (18) 25,000 150,000 Dimensions in inches and (millimeters). Approx. Weight Lbs. (Kg) Note: coils are rated for 50/60Hz NOTES: 1. All enclosures finished in grey. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 2.. This size enclosure is not suitable for mounting of Mercoid pressure switch. See drawing on page 1-3.

1-3 Dimensions Special Options Enclosure - Type NEMA 2, 12 - (Consult factory for details). Dimensions in inches and (millimeters). Motor Hp 0.33-15 0.33-20 0.33-5 0.33-10 0-80V 550-600V 120V 1 20V 1 Note: coils are rated for 50/60Hz Withstand Rating Standard Intermediate High 150,000 200,000 55 (25) 25,000 150,000 Approx. Weight Lbs. (Kg) NOTES: 1. All enclosures finished in grey. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 2.. This size enclosure required for mounting of Mercoid pressure switch.

1- Dimensions Standard Enclosure - Type NEMA 3R,, X, Dimensions in inches and (millimeters). Motor Hp 0.33-15 0.33-20 0.33-5 0.33-10 0-80V 550-600V 120V 1 20V 1 Note: coils are rated for 50/60Hz Withstand Rating Standard Intermediate High 150,000 200,000 0 (18) 25,000 150,000 Approx. Weight Lbs. (Kg) NOTES: 1. All enclosures finished in grey. 2. Cable Entrance either top or bottom. 3. NEMA, X enclosures are Stainless Steel.

1-5 Technical Data - Electrical Schematic Three Phase Single Phase

1-6 Dimensions WYE DELTA (Star-Delta) Dimensions in inches and (millimeters). Motor Hp Motor Kw 0.33-15 0.25-11 0.33-0 0.25-37 0.25-37 0.25-37 0.25-37 Note: coils are rated for 50/60Hz Withstand Rating Standard Intermediate High 0-80V 550-600V 25,000 150,000 200,000 55 (25) NOTES: 1. All enclosures finished in grey. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 2. Approx. Weight Lbs. (Kg)

1-7 Electric Motor Connections WYE DELTA (Star-Delta)

1-8 Options - Wiring Diagram ELAPSED TIME METER (Z) EXTRA CONTACTS - PUMP RUN (C1 PUMP OPERATING CONTACT ETM 1A 62 70 71 72 POWER ON LIGHT (L) PUMP OPERATING CONTACT (L1) 1A POWER ON R PUMP OPERATING CONTACT 1A 59 G RUN PERIOD TIMER (T) AC POWER FAILURE RELAY (C2 RPT 1 2 RPT 1 5 1A POWER FAILURE RELAY PF 73 7 75 EXTRA CONTACTS AC POWER FAILURE FDJP FDJY Horsepower (KW) Options 1/3 (0.25) C1 Extra Contacts "Pump Run" (one N.O. std.) 1/2 (0.373) C2 Extra Contacts "AC Power Failure" 3/ (0.56) E1 NEMA 3R - Raintight Enclosure (Refer to drawing on page 1-) 1 (0.75) E2 NEMA - Watertight Enclosure (Refer to drawing on page 1-) 1.5 (1.1) E3 NEMA 12 - Industrial Dust Tight Enclosure (Refer to drawing on page 1-2) 2 (1.5) E5 NEMA X - Stainless Steel Enclosure (Refer to drawing on page 1-) 3 (2.25) E7 NEMA 1 - Enclosure (23.6"H x 10.50"W x 6.38"D) ** 5 (3.75) E8 Tropicalization 7.5 (5.6) EX Export Crating 10 (7.5) POL "Power-On" Light 15 (11) PRL "Pump Run" Light 20 (15) P1 Mercoid 10-300 PSI Pressure Switch * 25 (18.6) P2 Mercoid 25-600 PSI Pressure Switch * 30 (22) P3 ALCO 90-50 PSI Pressure Switch 0 (30) P5 ALCO 15-260 PSI Pressure Switch 50 (37) P7 Low Suction Pressure Switch and Alarm Pilot Light P8 Low Suction Shutdown (Requires P7) P11 Pressure Switch (10-300psi) - Sea Water (Stainless Steel Mercoid Switch) Voltage P12 Pressure Switch (25-600psi) - Sea Water (Stainless Steel Mercoid Switch) A = 60 HZ R1 Space Heater (120 / 220V) B = 60 HZ R2 Space Heater c/w Thermostat C = 50/60 HZ R3 Space Heater c/w Humidistat D = 0-80V 60 HZ S Sequential Start E = 550-600V 60 HZ T Running Period Timer F = 16 V 60 HZ Z Elapsed Run Time Meter G1 = 120V Single Phase (FDJP only) * Includes oversized enclosure, refer to drawing on page 1-3. G2 = 20V Single Phase (FDJP only) ** Refer to drawing MD05805056K @ www.chfire.com.