Eve Ovens, Compactors, Room Air Conditioners, Dehumidifiers, Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers,Oishwash

Similar documents
30 BUILT-IN MICROWAVE OVEN COMBINATION

-J:, WALL. Before you begin. A. Space requirements

Installation Instructions

Electric Built-in Ceramic Cooktops

COMPACT 240 VOLT AUTOMATIC DRYERS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Before you begin. A. Space requirements IMPORTANT:

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

ICE MAKER Model 50. _. :a:; :& : $ys;*g :m.-,. ::,~~~;,~-,s,~..-:o-,~,-n, c_ Ipi.,r--.**i;p *... +~..?/ f,.

Installation Instructions

30 Built-In Microwave Oven Combination IMPORTANT: Installer: Leave these instructions with the homeowner. Homeowner: Retain these instructions for

IMPORTANT: Read and save these instructions. 24 and 30 Convertible Range Hood. Part No Rev. E

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Electric Built-in 24 and 27 Thermal Single and Double Ovens 24 and 27 Thermal Convection Single and Double Ovens

Installation Instructions Wall Ovens

Installation Instructions

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Service Manual Electric Cooktop

Installation Instructions

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

Combination. IMPORTANT: Read and save. these instructions. Par-t No W / Rev. A

DRYER INSTALLATION INSTRUCTIONS

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Electric Dryer Installation Instructions

Installation Instructions and Use and Care

Microwave Oven Hood Combination

Installation Instructions

Integrated Ventilation System

29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY

Installation Instructions

Installation Instructions 30 French Door Built-in Wall Ovens

2 PREPARE THE OPENING

Part No. 56oSolSPc

Installation Instructions

Downdraft Ventilation

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

Installation Instructions

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

Installation Instructions

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

Electric Dryer Installation Instructions

Cooktop Chimney Ventilation Hoods

Installation Instructions Remote Blowers

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

24 IN. (61 CM) ELECTRIC WASHER/DRYER INSTALLATION INSTRUCTIONS WASHER/DRYER SAFETY DANGER WARNING

Installation Electric Dryers Instructions 01

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

Installation Instructions

INSTALLATION INSTRUCTIONS

e Bath Fan with Light User s Guide

APPUZO RANGE HOOD INSTALLATION

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

Installation Instructions Induction Cooktop

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

Installation Instructions Dual Fuel Ranges

JP380BVBB - GE 30" Patio Grill with Downdraft Venting System

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION GUIDE NZ AU GB IE

READ AND SAVE THESE INSTRUCTIONS

Installation Instructions

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Steamer Module

Installation Instructions

breeze easytm model # F100-1W

Installation Instructions

Quick Reference. Table of Contents: ff you need assistance:

INSTALLATION INSTRUCTIONS 30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

ELECTRIC DRYER INSTALLATION INSTRUCTIONS 29" WIDE MODELS U.S.A. ONLY

Table of Contents/Table des matières COOKTOP SAFETY

e Bath Fan with Light User s Guide

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Instructions Preference Wall Mount Range Hood

Installation Instructions

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

READ AND SAVE THESE INSTRUCTIONS

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

ELECTRIC DRYER INSTALLATION INSTRUCTIONS 29" WIDE MODELS - U.S.A. ONLY

IMPORTANT: Read and save these instructions. 30 and 36 Convertible Range Hood

Smart Choice Electric Dryer Installation Kit

Installation Instructions

INSTALLATION INSTRUCTIONS

130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

Table of Contents DRYER SAFETY Tools and Parts... 3

read the following instructions completely and carefully. They will simplify the installation.

Installation Instructions

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

Use, Care, and Installation Guide

Installation Instructions

Transcription:

Eve Ovens, Compactors, Room Air Conditioners, Dehumidifiers, Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers,Oishwash

BEFORE YOU BEGIN: Read the following instructions completely and carefully. If followed, they will simplify the installation job. IMPORTANT: Observe all governing codes and ordinances. II Unpacking Instructions FILTERS LOCATED WIRING DIAGRAM LOCATION: A wiring diagram for the umt is included in the literature package and a copy is also located at the front of the control cavity (below the control mounting plate). CARDBOARD ELECTRICAL REQUIREMENTS A. A three-wire or four-wire single phase 120/240 volt 60 Hz AC only electrical supply (or three-wire or four-wire 120/208 volt if specified on nameplate) is required on a separate circuit fused on both sides of the line (timedelay fuse or circuit breaker is recommended). Do NOT fuse neutral. The fuse size must not exceed the circuit rating of the appliance specified on the nameplate. NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with National Electrical Code and local codes and ordinances. Do not use an extension cord. B. The appliance should be connected to the fused disconnect (or circuit breaker) box through flexible armored or non-metallic sheathed cable. The flexible armored cable extending from the appliance should be connected directly to the junction box. The junction box should be located as shown in Figure 4 on page 3 so that as much slack as possible remains in the cable between the box and the appliance so that it can be moved if servicing is necessary. A. Remove all tape from surface unit, including tape holding filters inside appliance. See Figure 1. B. Remove the grill and surface unit module from the unit and place them in a safe place. C. Save cardboard corner inserts in shipping carton for use in Step 5. IF Location of Unit The cooktop relies upon air patterns J surrounding the cooking surface for proper operation. Drafts caused by home heating and air conditioning and/or open doors and windows can disrupt this pattern. Installation as shown in Figures 2 & 3 can also cause improper C. A suitable strain relief must be provided to attach the power supply cord to the junction box. lnsutlicienl Clearance sewdeen Unit and Side Wall FIG. 2 Currenk Moving Through Tunnel Distorl Normal Air Pattern* FIG. 3 The owner should be aware of occasional shifts of the air flow pattern allowing steam to escape into the room caused by drafts or changes in the air flow pattern of the room. This is normal.

8 Prepare Countertop Cutout Opening EXCEED A MAX - 30 MIN. / APPROXIMATE \ 1 LOCATION \ OF JUNCTION / \ I # A Provide Electrical Install the junction box under the cabinet and run the Connection 1 20/240 Volt, (or 120/208 Volt if specified on nameplate) AC wire from the maln circuit panel. (DO NOT connect the wire to the circuit panel at this time. For basic information, see Electrical Requirements on page 2. 3

Ei Install Ventilation System SPECIAL NOTE: For shipping reasons, the Blower Housing will not be positioned at the proper angle for venting. To correct, simply grasp the Blower Housing and rotate it to the proper angle needed for your installation application. See Figures 5 & 6. THROUGH-THE-WALL INSTALLATION (Outside Wall Installation Shown) THROUGH-THE-FLOOR INSTALLATION (Peninsula or Island Installation Shown) BLOWER HOUSING BLOWER HOUSING Install directly to outside following dimensions shown below. Install between floor joists following dimensions shown below. CENTER EXHAUST LINE OF VENT CENTER EXHAUST LINE TO VENT w I -- 5-3/4 ikom CENTER LINE OF VENT TO FRONT EDGE OF J 4

PROPER AIR MOVEMENT AND VELOCITY (USE METAL DUCTING ONLY) Flexible Ducting: Due to the irregular surface of flexible ducting, each foot of the flex duct counts as two feet of straight metal duct. Elbows made of flex ducting would count twice as much as a standard metal elbow, Attic Venting: Never vent to either attrc or crawl space. Unit must always be ducted to the outside. Uniform Size: All ductrng should be umform throughout the complete system for proper performance. Duct Restrictions: Never Install two elbow fittings next to each other, This causes unusual air patterns and subsequently interrupts velocity and the end result IS poor ventrlation. Sealing joints: All joints in the duct system must be tightly taped to avoid smoke and odor in the home. Also, be sure to caulk thoroughly all joints in floor or wall where duct system goes to the outside. DUCT LENGTH RECOMMENDATIONS (MAXIMUM) 6 Dia. or 3-l/4 x 10 Duct Use 6 or 3-l/4 x 10 duct on island or peninsula installations. For best performance, it IS suggested that no more than three 90 elbows with 6 or 3-l/4 x 10 duct be used. 1 Maximum Calculated Length 1 26 feet I When using flexible tubing: 6 System Calculation (Maximum allowable calculated length 26 feet) 3-l/4 x 10 System Calculation (MaxImum allowable calculated length 26 feet) 90 Elbows b- 6 Ft.-( Wall -t(2) 90 Elbows @ 5 Ft. Ea. = 10 Ft. Surface Wall Cap = 0 Ft. 8 Ft. Straight 6 Pipe = 8 Ft. Length of 6 Run = 18 Ft. (1) 90 Elbow (3-l/4 x 10 ) Wall Cap (1) 6 to 3-1/4 xlo Elbow = 5 Ft. = 0 Ft. = 5 Ft. 8 Ft. Straight 3-1/4 xlo = 8 Ft. Length of 3-l/4 x 10 Run = 18 Ft. INDEX OF RECOMMENDED STANDARD FITTINGS 6 Svstems: Eauivalent length of 6 Duct 3-1/4 xlo Systems: Equivalent lenqth of 3-114 xlo Duct T 3-1/4 xlo to 6 3-1/4 xlo to 6 90 Elbow Equiv. Length 4.5 Ft. Equiv. Leng T L 90 Elbow 6 to 45O Elbow 3-1/4 XlO 6 to 3-1/4 xlo 90 Elbow 3-1/4 xlo to 6 6 to 3-1/4 xlo 90 Elbow 6 to 3-114 xlo th 5 Ft.1 Equiv. Length 9 Ft Equiv. Length 4.5 Ft. Equiv. Length 6 Ft Equiv. Length 1 Ft. 6 Wall Cap 3-1/4 XlO 90 Elbow 3-1/4 XlO Flat Elbow 3.1/4 XlO Wall Cap @ Equiv. Lenuth -7 5 Ft Equiv. Lensth 1 FI Note; Never use laundry type wall caps. 0 Equiv. Equiv. Length 2.5 Ft Lenoth 0 Ft Equiv. Length 5 Ft Equiv. Length 12 F Equiv. Length 0 Ft 5

0 Install Surface Unit Place surface unit on its side (resting on unfolded cardboard corner insert from shipping carton). Remove wood skids from bottom, install Venting Adapter to Blower Housing by using the three screws provided. See Figure 8. NOTE: Because of the length of the Venting Adapter, the Blower Housing should be rotated downward in order to clear the cabinet opening Insert unit into countertop opening and tighten hold down bolts at each end of unit as shown in Figure 9. Install the cooking components in the surface unit. (For the correct installation procedure, see Use and Care Guide in the Literature Package.) ENT ADAPTER MOUNTING SCREWS \ \ \ \ BLOWER \ 7 6

7 Make Electrical Connection JUNCTION BOX \ GROUNDED NEUTRAL FROM S Y POWER COPPER GROUND GROUNDED COLD WIRE WATER PIPE \ (REMOVE PAINT, ETC.) UNGROUNDED NEUTRAL JUNCTION FROM POWER BOX \ FOURCE EN FIRMLY ACK (p GREEN OR 3r- BARE WIRE GROUND CLAMP (MUST BE TIGHT ON PIPE) GREEN OR BARE WIRE APPLIANCE Connect the flexible armored cable that extends from the surface unit to the junction box using a suitable strain relief at the point the armored cable enters the junction box. Then make the electrical connection as follows: It is the personal responsibility and obligation of the customer to contact a qulaified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code and local code ordinances. Electrical ground is required on this appliance. This appliance is equipped with copper lead wires. If connection is made to aluminum house wiring, use only special connectors which are approved for joining copper and aluminum wires in accordance with the National Electrical Code and local codes and ordinances. This appliance is manufactured with a white neutral power supply wire and a frame connected green (or bare) ground wire twisted together. If local codes permit connection of the frame grounding conductor to the neutral (white) wire, connect the green (or bare wire) and white wire from the supply cable of the appliance together and the neutral (white) wire in the junction box. Connect the remaining wires from the supply cable to the wires in the junction box. See Figure 10. If local codes DO NOT permit frame grounding to the neutral, separate the white (and green or bare wires) that extend Connecting the Vent System Connect Venting Adapter on bottom of appliance to installed venting system (refer to pages 4 and 5 for venting instructions). out of the end of the supply cable of the appliance. See Figure 12. Connect the white wire from the supply cable to the neutral wire in the junction box. Connect the black (or brown) and red wire from the supply cable, to the corresponding wires in the junction box. The green (or bare) wire must now be used to ground the appliance in accordance with local electrical codes. Connect the green colored copper (or bare) ground wire to a grounded cold water pipe* (see Figure 11) or to the grounded lead in the service panel. Do not ground to a gas supply pipe. Do not connect to electric power supply until appliance is permanently grounded. Connect the ground wire before turning on the power. (See Figure 11.) CAUTION - If connecting to a four-wire electrical system (MOBILE HOME) the appliance frame MUST NOT be connected to the neutral wire of the four-wire electrical system. Separate the white (and green or bare wires) that extend out of the end of the supply cable of the appliance. Connect the white, red and black (or brown) wires from the supply cable, to the corresponding wires in the junction box. Connect the green(or bare) wire from the supply cable to the ground wire in the junction box. (See Figure 12) *Cold water pipe must have metal continuity to electrical ground and not be interrupted by plastic, rubber or other electrically insulating connectors (including water meter or pump) without adding a Jumper wire at those connections. Check Operation When all connections for the appliance have been made, turn each control on to make sure the components are operating correctly. For instructions on operating, cleaning and maintaining this appliance, refer to Use and Care Guide in the Literature Package.

YLirlnool HOME. 1. APPLIANCES Making your world a little easier. In the event your WHIRLPOOL appliance should need service, call the dealer from whom you purchased the appliance or a WHIRLPOOL franchised TECH-CARE@ service company. He is in the Yellow Pages of your telephone directory listed under Appliances-Household-Major-Service and Repair. You can also obtain his name and number bv dialina. free. within the continental United States the Whirlpool COOL-LINE@ Service (800) 253-1301. When calling from Michigan, dial (800) 632-2243; from Alaska or Hawaii, dial (800) 253-1121 Dial just es you normally dial long distance. A special operator will tell you the name and number of your nearest Whirlpool TECH-CARE service outlet. During normal working hours, Whirlpool consultants et this same number will also answer any questions about operating or maintaining your appliance not covered in your Use and Care Guide. Learn the benefits of using TECH-CARE service for maintaining the quality originally built into your WHIRLPOOL appliance. Part No. 54257/4179084 Printed in U.S.A. idifiers Automatic Washers, Clothes Dryers, Freezers, Refrigerator-Freezers, Ice Makers, Dishwashers, Built-In Ovens and Surface Units, Ranges, Microw;