MODEL ZCVF36 MODEL ZCVF42

Similar documents
W / C / W / C /

W / W /

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 2021 NEFE AM-1 ELECTRIC FIREPLACE MANTEL

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE

HD81 GLASS BURNER ASSEMBLY

OWNER S MANUAL CARTER FIREPLACE. Product code: UPC code: Date of purchase: / /

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ETL CHFP-50A ELECTRIC FIREPLACE ! WARNING

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

LO-RIDER UNVENTED VENT-FREE FIREBOXES INSTALLATION AND OPERATING INSTRUCTIONS

SOUTHWEST FIREBIRD MFG SONORAN UNVENTED Model 36/42/48

TERRACE AND PATIO HEATER

W / C / $10.00 W / C /

(UNIVERSAL BOX) FOR USE ONLY WITH A LISTED GAS- FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H. DO NOT BUILD A WOOD FIRE

LO-RIDER UNVENTED VENT-FREE FIREBOXES INSTALLATION AND OPERATING INSTRUCTIONS WARNINGS WARNINGS MODEL: LCUF32-F LCUF36-R

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

CAUTION FOR YOUR SAFETY

UVST (SMOOTH FACE) UVCST (HEAT CIRCULATING) INSTALLATION & OPERATING INSTRUCTIONS

ADDISON Freestanding Electric Stove Models: ACSB

SURE HEAT MANUFACTURING

TERRACE AND PATIO HEATER

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL

BF33ST/DX BF39ST/DX BF45ST/DX

INSTALLING AND OPERATING YOUR MONTIGO GAS-BURNING FIREPLACE

DIRECT VENT MILLIVOLT SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS FOR COMBINATION ELECTRIC AND DIRECT VENT GAS FIREPLACE

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

EFL32H, EFC32H EFL48H, EFL60H, EFL72H

Model: SFE-ST FOR YOUR SAFETY ANSI / UL INSTALLER: DO NOT DISCARD THIS MANUAL -- LEAVE FOR HOME OWNER BUILDER BOX

Please Keep This Manual For Future Reference REV.01

INSTALLATION AND OPERATING INSTRUCTIONS

VENTED GAS FIREPLACE HEATER DIRECT VENT MILLIVOLT SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS

Installation and service must be provided by a qualified installer, service agency or the gas supplier.

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 2021 BEF33H & BEF40H ELECTRIC FIREPLACE

INSTALLATION OPERATION AND SERVICE MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

INSTALLATION AND OPERATION INSTRUCTIONS

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

EMPIRE. Deluxe Vent-Free Universal Fireboxes MODELS

IMPORTANT SAFETY INFORMATION:

Repeat procedures for other side.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Questions? us at or visit our website at

CARBON MONOXIDE HAZARD. This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you.

napoleonfireplaces.com WOOD BURNING WOOD BURNING FIREPLACES

Gas Stoves & Inserts. Innovative Heating Solutions continentalfireplaces.com

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Unvented Fireboxes Installation and Operating Instructions

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLER: LEAVE THIS MANUAL WTIH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

INSTALLATION AND OPERATION INSTRUCTIONS FOR

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

CERTIFIED UNDER AMERICAN NATIONAL STANDARDS, ANSI Z B, VOLUME II FOR UNVENTED ROOM HEATERS.

SURE HEAT. Installation and Operating Instructions for NATURAL & L.P. GAS VENT FREE SYSTEM

INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

FOR OUTDOOR INSTALLATION ONLY. If the information in these

Stoves & Inserts. Gas. continentalfireplaces.com

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

CINCINNATI, OH USA

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

VENT-FREE GAS FIREBOX OWNER S OPERATION AND INSTALLATION MANUAL

INSTRUCTION MANUAL. Full Size Gas Convection Oven

Installation & Owner s Manual Installation, Care and Operation

UNVENTED MILLIVOLT SYSTEM

MAGNUM UNVENTED VENT-FREE FIREBOXES INSTALLATION AND OPERATING INSTRUCTIONS WARNINGS WARNINGS. MODELS: MCUF36D and MCUF42D SERIES

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

PRACTICAL USER S GUIDE FOR THE CORNER WALL MOUNTED ELECTRIC FIREPLACE

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

Heat-N-Glo. Installers Guide. Model: 8000TVC

(UNIVERSAL BOX) FOR USE ONLY WITH A LISTED GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H DO NOT BUILD A WOOD FIRE

UVDC, UVDR Ventless Fireplaces

PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING AND

INSTALLATION AND OPERATING INSTRUCTIONS

ELECTRIC FIREPLACE OWNER S MANUAL

(UNIVERSAL BOX) FOR USE ONLY WITH A LISTED GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H. DO NOT BUILD A WOOD FIRE

ASSEMBLY INSTRUCTIONS

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

ASSEMBLY INSTRUCTIONS

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL

NO VENTING REQUIRED 120V AC;

Installation & Owner s Manual Installation, Care and Operation

INSTALLATION AND OPERATION INSTRUCTIONS FOR ZERO CLEARANCE AND INSERT UNITS

IMPORTANT SAFETY INFORMATION:

Transcription:

1 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Conforms to the standard ANSI Z21.91 2004 Ventless Firebox Enclosures for Unvented Room Heaters INSTALLATION INSTRUCTIONS FOR THE ZERO CLEARANCE VENTLESS FIREBOX ENCLOSURE MODEL ZCVF36 MODEL ZCVF42 CERTIFIED FOR UNITED STATES USING ANSI METHODS WARNING: If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of this or any other appliance. Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building. WHAT TO DO IF YOU SMELL GAS: Immediately call your gas supplier from a neighbour s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada. (705) 721-1212. fax(705)722-6031 W415-0527/ 09.29.05

2 PG 3 INTRODUCTION Warranty 4-6 INSTALLATION & FINISHING General Instructions Hood Installation Gas Connector Locations Framing Nailing Tab Instruction Mantle Clearances 7 OPTIONS Optional Blower Installation TABLE of CONTENTS 8 REPLACEMENTS Replacements Replacement Parts Accessories 9 SERVICE HISTORY FOR USE ONLY WITH A ANSI Z21.11.2 LISTED GAS-FIRED UNVENTED ROOM HEATER NOT TO EXCEED 40,000 BTU/H FOLLOW THE INSTRUCTIONS, AND COMPLETE THE INSTALLATION OF THE UNVENTED ROOM HEATER. DO NOT BUILD A WOOD FIRE. Carefully review the instructions supplied with the unvented room heater for the mimimun firebox size requirement. DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION. PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE WARNING Under no circumstances should this enclosure be modified. Provide adequate ventilation and combustion air. Refer to unvented room heaters installation instructions. Never obstruct the front opening of the enclosure. Do not burn wood or other materials in this enclosure. Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the ventless firebox enclosure is hot. Due to high temperatures, the enclosure should be located out of traffic and away from furniture and draperies. Clothing or other flammable material should not be placed on or near the enclosure. Any safety screen or guard removed for servicing must be replaced prior to operating the enclosure. It is imperative that the circulating air passageways in the enclosure are kept clean. The enclosure should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The enclosure area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids. Furniture or other objects must be kept a minimum of 4 feet away from the front of the ventless firebox enclosure. Do not use this enclosure if any part has been under water. Immediately call a qualified service technician to inspect the enclosure and to replace any part of the control system and any gas control which has been under water. Do not allow fans to blow directly into the ventless firebox enclosure. Avoid any drafts that alter burner flame patterns. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this enclosure. NOTE: CHANGES, OTHER THAN EDITORIAL, ARE DENOTED BY A VERTICAL LINE IN THE MARGIN W415-0527 / 09.29.05

3 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete ventless firebox enclosure is test-fired and thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON. NAPOLEON GAS FIREPLACE PRESIDENT S LIFETIME LIMITED WARRANTY The following materials and workmanship in your new NAPOLEON ventless firebox enclosure are warranted against defects for as long as you own the ventless firebox enclosure. This covers: combustion chamber, heat exchanger, phazer logs and embers. Electrical (110V and millivolt) components and wearable parts such as blowers, thermal switch, switches, wiring, and remote controls, are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty. Labour related to warranty repair is covered free of charge during the first year. Repair work, however, requires the prior approval of an authorized company official. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer. CONDITIONS AND LIMITATIONS NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations: This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives. The ventless firebox enclosure must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building and fi re codes. This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty. This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER logs and embers. In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions. After the first year, with respect to this President s Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s). After the fi rst year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty. Notwithstanding any provisions contained in this President s Limited Lifetime Warranty, NAPOLEON S responsibility under this warranty is defi ned as above and it shall not in any event extend to any incidental, consequential or indirect damages. This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON ventless fi rebox enclosure and any other warranties expressed or implied with respect to this product, its components or accessories are excluded. NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for: over-firing, inadequate ventilation, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc. Any damages to the ventless fi rebox enclosure, combustion chamber, brass trim or other component, due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON. The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty. NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim. ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. WOLF STEEL LTD. W415-0527/ 09.29.05

4 GENERAL INSTRUCTIONS THE INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.1 / NFPA 54 AND TO THE NATIONAL ELECTRICAL CODE, ANSI / NFPA 70. Use only accessories designed for and listed with your specific firebox. Not designed for use with a glass door. Screen must be closed when appliance is in operation. HOOD INSTALLATION Warning: Do not operate without hood in place. The fi rebox hood must not be modifi ed or replaced with a hood that may be provided with the unvented decorative room heater. 1 3/4 21 1/8 SPECIFICATIONS ZCVF36 42.000 31 7/8 32 1/2 2 1 ZCVF42 1 3/4 46 5/8 FIGURE 1 Note: Remove the hood from the back side of the carton by cutting the cable ties holding it in place. 1. Slide the edge of the hood into place on the top inside surface of the ventless fi rebox enclosure to align with the three pre-drilled holes. 2. Screw the hood securely into place with the three screws provided. (FIGURE 1) 21 1/8 36 3/8 35 1/2 W415-0527 / 09.29.05

5 There are fi ve gas inlet locations on the ventless firebox enclosure. One on each side of the unit, two at the rear, and one on the bottom. Using the following illustrations (FIGURE 2a-f) identify the preferred inlet and remove corresponding knock out. ZCVF36 GAS INLET LOCATIONS ZCVF42 7 7 FIGURE 2a 13 1/4 FIGURE 2b 13 1/4 7 7 FIGURE 2c 13 FIGURE 2d 16 1/3 16 3/8 16 3/8 21 23 1/3 FIGURE 2e FIGURE 2f W415-0527/ 09.29.05

6 FRAMING ANY CHANGE TO THIS ENCLOSURE CAN BE DANGEROUS AND IS PROHIBITED. It is best to frame your ventless fi rebox enclosure after it is positioned. Use 2x4 s and frame to local building codes. (FIGURE 3-5) FIGURE 3 ZCVF36 ZCVF42 32 3/4" 35 3/4" 21 1/4" 42 1/2 21 1/4" 47 1/8 FIGURE 4 52 1/3 42 1/2 74 1/8 55 5/8 47 1/8 78 5/8 FIGURE 5 OUTSIDE CHASE 21 1/4" OUTSIDE CHASE 21 1/4" 42 1/2" 47 1/8" 21 1/4 INSIDE CHASE 21 1/4 INSIDE CHASE 42 1/2 6" 47 1/8 6" Minimum clearance to combustible construction from ventless firebox enclosure: sides, back, bottom and top of the unit 0 inches recessed depth 21 1/4 inches Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the ventless fi rebox enclosure body, it is recommended that the walls of the ventless fi rebox enclosure enclosure be finished (ie: drywall/sheetrock), as you would fi nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity. When roughing in the ventless firebox enclosure, raise the ventless fi rebox enclosure to accommodate for the thickness of the fi nished fl oor materials, i.e. tile, carpeting, hard wood. Objects placed in front of the ventless fi rebox enclosure should be kept a minimum of 4 feet away from the front face. W415-0527 / 09.29.05

7 NAILING TAB INSTRUCTION 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts. If there are no existing holes, follow these instructions: Position the nailing tab so that the front face is offset with the front edge of the corner post (approx. ½ ). Centre the nailing tab vertically on the corner post. (FIGURE 6a) Drill through the centre of the top and bottom slots in the nailing tab. Secure using the two sheet metal screws supplied. This allows the nailing tab to slide back and forth for desired framing. (FIGURE 6b) 2) To determine the fi nal location of the nailing tab you must fi rst determine the width of your fi nishing material (i.e. drywall). This will determine the dimension from the front edge of the corner post to the nailing tab. Once the nailing tab is in the desired location, drill through the centre hole of the nailing tab. Secure with a sheet metal screw*. (FIGURE 6c) * Additional set screws may be installed. MANTEL CLEARANCES Combustible materials may be installed fl ush with the front of the ventless fi rebox enclosure but must not cover any of the black face-areas of the ventless fi rebox enclosure. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas. Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance FIGURE 7 FIGURE 6a CORNER POST NAILING TAB TOP SLOT FIGURE 6b FINISHING MATERIAL 7"MANTLE MANTEL 7" 6" 6"MANTLE MANTEL 4"MANTLE MANTEL 4" COMBUSTIBLE MATERIALS STUD TOP OF UNIT FIGURE 8 7 M H 6 A E 5 I 4 N G L T H E T L 4 5 6 7 MANTLE MANTEL WIDTH FIGURE 6c CENTRE HOLE W415-0527/ 09.29.05

8 INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current ANSI/NFPA 70 National Electrical Code. If the fi rebox was not previously equipped with a blower: route a grounded 2-wire, 60hz power cable through the junction plate cover. At this point it must be strain relieved and insulated. OPTIONAL BLOWER INSTALLATION Secure to the threaded stud using the lock washer and wing nut provided. Ensure that the blower does not touch the fi rebox base or the firebox. (FIGURE 9) Attach the connectors from the black and red wires to the blower. The three slots on the blower mounting bracket allow ease of adjustment when attaching the blower. (FIGURE 10) For a quiet running blower, do not allow the assembly to sit on the fi rebox base. Slide the vibration reducing pad (a) into the clip (c) and up against the threaded stud (b) at the other end. The blower must be able to be positioned entirely onto the pad. Tilt the blower onto its side. Slide it past the controls and into the clip (c). B A FIGURE 10 The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects. Because the blower is thermally activated, when turned on, it will automatically start approximately 30 minutes after lighting the vent free room heater and will run for approximately 30-45 after the vent free room heater has been turned off. Use of the fan increases the output of heat. Drywall dust will penetrate into the blower bearings causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy. C W415-0527 / 09.29.05

9 Note: In either application it is necessary to remove the variable speed switch from the wiring harness and install into an electrical switch box as per electrical codes. WITH THERMAL SWITCH BRACKET 1. Remove the hearth pads and the blower access cover. (FIGURE 9) 2. Install the blower using the optional blower installation instructions. 3. Pull the black and white thermal disc wires through the 7/8 bushing in the blower access cover. 4. Cut the white wire as close to the connector as possible. (FIGURE 11). 5. Cut the red wire as close to the plug as possible. (FIGURE 11) 6. Using a box connector, connect supply wire through the junction cover plate located on the right sidce of the fi rebox enclosure. 7. Connect the red and white wires to the power supply. Attach the ground to the ground screw on the junction plate cover. 8. Replace the blower access cover. 9. Attach the black & white wires to the back of the thermal switch and install at the rear of the fi rebox using the thermal switch support bracket as circled in (FIGURE 9). 10. Replace the hearth pads. BLACK BLOWER WITHOUT THERMAL SWITCH BRACKET 1. Remove the hearth pads and blower access cover. (FIGURE 9) 2. Install the blower using the optional blower installation instructions. 3. Cut the red wire as close to the plug as possible. 4. Cut the black wire as close to the fl ag connection as possible. (FIGURE 12). 5. Using a box connector, connect supply wire though the junction cover plate located on the right side of the fi rebox enclosure. 6. Attach the ground to the ground screw on the junction plate cover. 7. Replace the blower access cover plate and hearth pads. BLACK WHITE RED THERMAL DISC BLOWER WHITE RED THERMAL DISC FIGURE 12 VARIABLE SPEED SWITCH FIGURE 11 VARIABLE SPEED SWITCH 1 2 3 4 1. Hearth Pads 2. Blower Access Cover 3. Thermal Switch Support Bracket 4. 7/8 Bushing 5. Junction Box FIGURE 9 5 GROUND SCREW W415-0527/ 09.29.05

10 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. ZCVF36 REPLACEMENT PARTS # PART No. DESCRIPTION 1* W385-0245 Napoleon Logo 2 W565-0084 Curtain Mesh 3 W555-0056 Curtain Rod 4 W335-0044 Hood 5* W500-0192 Panel Brackets 6 W475-0400 Hearth Pad (Right) 7 W475-0386 Hearth Pad (Left) ACCESSORIES # PART No. DESCRIPTION 8* 111KT Outside Air Kit 9* 112KT Adaptor Plate, Outside Air Kit 10* GD810-KT Brick Panels (Cobblestone) 11 DKZC36SS Decorative Door 12 TBZC36K 36 3 Bevelled trim (textured black) 13* TBZC36SS 36 3 Bevelled trim (satin chrome) 14 GZ550-1KT Blower kit 15* W500-0033 Switch Wall Mounting Plate REPLACEMENTS When ordering replacement parts always give the following information: 1. Model & Serial Number of ventless firebox enclosure 2. Installation date of ventless firebox enclosure 3. Part Number 4. Description of part 5. Finish ZCVF42 REPLACEMENT PARTS # PART No. DESCRIPTION 1* W385-0245 Napoleon Logo 2 W565-0085 Curtain Mesh 3 W555-0057 Curtain Rod 4 W335-0045 Hood 5* W500-0192 Panel Brackets 6 W475-0399 Hearth Pad (Right) 7 W475-0382 Hearth Pad (Left) ACCESSORIES # PART No. DESCRIPTION 8* 111KT 111-KT Kit 9* 112KT 112 Collars 10* GD809-KT Brick Panels (Cobblestone) 11 DKZC42SS Decorative Door 12 TBZC42K 42 3 Bevelled trim (textured black) 13* TBZC42SS 42 3 Bevelled trim (satin chrome) 14 GZ550-1KT Blower kit 15* W500-0033 Switch Wall Mounting Plate * IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION, CONTACT YOUR NAPOLEON DEALER. 12 3 11 2 4 7 14 6 W415-0527 / 09.29.05

11 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Date Dealer Name Service Technician Service Performed Special Concerns Name W415-0527/ 09.29.05

12 NOTES W415-0527 / 09.29.05