Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016

Similar documents
Technical Note. Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6. TC Project no.: T Page 1 of 10.

Technical Note. Noise emission from Dehumidifier Type C22/CR100. TC Project no.: T Page 1 of January 2016

TEST REPORT No. EN-2160/057/15-098/15

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

Supplementary type approval testing of Selco modules

This document is a preview generated by EVS

Test Report Nº B2016 LACUS IN 24

DELTA Classification Report

Determination of air borne sound insulation According to ISO 140-3

TNO report MON-RPT-033-DTS

ISO INTERNATIONAL STANDARD. Small craft Airborne sound emitted by powered recreational craft Part 1: Pass-by measurement procedures

ISO INTERNATIONAL STANDARD

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

INTERNATIONAL STANDARD

PCT Workshop Before you leave the office

Hemi Anechoic Chamber Number:

Consumer vacuum breast-pumps

Report Number BTC 15450A

AGREEMENT CONCERNING THE ADOPTION OF UNIFORM CONDITIONS OF APPROVAL AND RECIPROCAL RECOGNITION OF APPROVAL FOR MOTOR VEHICLE EQUIPMENT AND PARTS

INTERNATIONAL STANDARD

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones

Bruksanvisning Directions for use

o Rear HVAC columns (Priority 1: Item 3) the rear ceiling area: be more dead for the organ and traditional music. (Priority 2: Item A)

ISO 6393 INTERNATIONAL STANDARD. Earth-moving machinery Determination of sound power level Stationary test conditions

Gern Glas Order no. 0302/ Industrivej 4 Page 1 of Sorring Appendicis 1 Danmark Initials MJLD/MFRI

Acoustical Test Methods and Sound Power Rating Procedures for Transport Refrigeration Equipment

According to the following European Regulations which come into force:

ISO INTERNATIONAL STANDARD

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Brief Synopsis of the Japanese MOE Sponsored Evaluation of Wind Turbine Noise

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Room Acoustics, PA Systems and Speech Intelligibility for Voice Alarm Systems using the example of the Cruise Center Steinwerder

Heat Recovery Unit HERU. web-version

Sound Performance Rating of Non-ducted Indoor Airconditioning

Measuring Sound Pressure Level with APx

ROOFMASTER STEF-HT ROOF FAN

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

CASE STUDY. History. Testing Laboratories. GHSP Testing Laboratories A2LA Accredited Testing Laboratory. United States of America

CNBOP-PIB Standard Fire Protection

Handbook Qualification Quiet Room label

The Ed Roberts Campus Berkeley, CA

Installation, operation and maintenance guide for window models

Daikin Altherma Selection Report

CALIBRATION HOW IT WORKS

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

Acoustics in open-plan offices A laboratory study

Sound Performance Rating of Outdoor Unitary Equipment

Vibration tests on a TNAML Luminaire

ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

Specimen delivery date: Test date: Sampling: The test specimen sampled by customer. Order description N o 152/

S TAR-ORION S OUTH D IAMOND P ROJECT E NVIRONMENTAL I MPACT S TATEMENT APPENDIX A FUNDAMENTALS OF ACOUSTICS

REPORT SUNDBYBERG KOMMUNHUS, MEASUREMENT OF SOUND PRESSURE LEVELS IN OPEN PLANE OFFICES STORKONOTOR

next DX.U.S* 052.Z2.H6.DC

Wayside horn noise investigation

CALIBRATION HOW IT WORKS

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

EEDEN technical data ERHQ AA

Type approval testing of miscellaneous smoke and heat detectors for marine applications

Ceiling air diffuser INDULTHERM INDULTHERM-e

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Avicii 2014 Centennial Parklands, Sydney 25 th January 2014

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Appendix 1 Reference HOB and boiler efficiency

Do you want a versatile solution

Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants

PRODUCT DATA 2260 H, BZ Hand-held FFT System 2260 Investigator and FFT Software BZ7208 Type 2260 H

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

CONDOR. Supply air ceiling QUICK FACTS

CERTIFICATE of Product Conformity (QAL1 )

Determination of airborne sound insulation factor (designation of the test)

INSPECTION REPORT Nr IDD/S-09/922

REPORT. Condensing air heaters. Technology evaluation. Project report Maj 2013

CALIBRATION HOW IT WORKS

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

HOTEL CHILLED BEAM IQ STAR SILENCIA

This document is a preview generated by EVS

European Technical Assessment ETA 17/1007 of 02/05/2018

E/ECE/324/Rev.1/Add.27/Amend.5 E/ECE/TRANS/505/Rev.1/Add.27/Amend.5

PRODUCT CONFORMITY CERTIFICATE

Refrigerating Appliance ErP Test Report

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Sunlight Supply, Inc.

Acoustic Verification Report

TEST REPORT: CHM14-05-CHY

INSTRUMENTATION FOR MARINE BLACK CARBON MEASUREMENTS

Compact and silent Scroll compressors All-season operation

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

draft dated 9/17/2015 page 1

Lawnmowers, pedestrian controlled (combustion engine powered)

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

GLOSSARY OF ACOUSTICAL TERMS

ISO INTERNATIONAL STANDARD. Acoustics Guidelines for noise control by silencers

Listen Out 2016 Centennial Parklands, Sydney 1 st October 2016

Transcription:

Technical Note Noise emission from Dehumidifier Type C65E-11.1 Performed for COTES A/S Project no.: I101033 Page 1 of 10 01 July 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. +45 72 19 40 00 Fax +45 72 19 40 01 www.delta.dk VAT No. 12275110 The report must not be reproduced, except in full, without the written approval of DELTA.

Page 2 of 10 Title Noise emission from Dehumidifier Type C65E-11.1 Journal no. Project no. Our ref. I101033 RUE/JEL/ilk Client COTES A/S Ndr. Ringgade 70c 4200 Slagelse Denmark Client ref. Rasmus Toftegaard Laboratory DELTA Agro Food Park 13 8200 Aarhus N Denmark Test conditions DS/EN ISO 11202:2010 DS/EN ISO 3744:2010 Results The dehumidifier type C65E-11.1 has been tested on 7 June 2016 and the sound pressure level was measured 1 metre from the dehumidifier in four positions. The maximum A-weighted sound pressure level, L pa at 1 metre distance was measured in position B (left side) at nominal flow mode: Standard deviation is σ tot = 1.6 db. Remarks 69.0 db re 20 µpa The results apply only to the object tested. Results are rounded to the nearest 0.5 db. DELTA, 1 July 2016 Rune Egedal Specialist, Acoustics Jens Elgaard Laursen Senior Specialist, Acoustics

Page 3 of 10 Contents 1. Introduction... 4 2. Test object... 4 2.1 Operating conditions during test... 5 3. Acoustic environment... 5 4. Measurement methods... 5 5. Sound pressure measurements and corrections... 6 6. Test results... 6 6.1 Sound pressure levels... 6 Annex 1 Measurement points... 8 Annex 2 Instrumentation... 9 Annex 3 Sound power levels for reference sound source B&K 4204... 10

Page 4 of 10 1. Introduction On behalf of COTES A/S, DELTA has performed sound measurements on a dehumidifier type C65E-11.1. The noise measurements were performed according to DS/EN ISO 11202:2010. 2. Test object Type: C65E-11.1 Make: COTES A/S Serial No.: 16.11018 Process Flow: 2600 m 3 /h Reg. Flow: 460 m 3 /h Power: 16.2 kw Dimensions: L: 820 mm / W: 1165 mm / H: 1615 mm Figure 1 Test set-up for the dehumidifier C65E-11.1. The front here is Position A (see Annex 1).

Page 5 of 10 2.1 Operating conditions during test The dehumidifier was tested operating at nominal flow mode. The noise emission was steady for the specified operating mode. 3. Acoustic environment The dehumidifier was placed indoor in a large workshop room at COTES, Rudolfgårdsvej 1A, 8260 Viby, Denmark (see Figure 1). On the ceiling of the workshop were mounted acoustic absorbing panels. The main dimensions of the room are 13.5 m 8 m 2.8 m (length width height). The acoustic quality of the test room was measured with a reference sound source from Brüel & Kjær type 4204. The measurements were performed by Rune Egedal, DELTA Acoustics, on 7 June 2016 and were performed according to ISO 3744 annex A2 in order to calculate the test rooms environmental correction factor K 2A. The results are listed in Table 1. 63 125 250 500 1000 2000 4000 K 2A [db re 20 µpa] 1.0 1.6 1.9 2.4 2.9 3.0 2.3 1.9 Table 1 Values of K 2A for the test room at COTES A/S, Viby J. 8000 The K 2A values are all lower than 7 db, and the test room therefore qualifies for sound pressure measurements according to DS/EN ISO 11202. The sound power level values of the reference sound source are enclosed in Annex 3. 4. Measurement methods The measurements were performed according to standard DS/EN ISO 11202. The sound pressure level was measured in four positions at 1 metre distance from the test object and at a height of 1.55 metre as illustrated in Annex 1. A photo of the measuring set-up is shown in Figure 1. The measurements of the test object were performed on 7 June 2016 by Rune Egedal, DELTA Acoustics. The used instruments are listed in Annex 2. All measurements were performed with the test object in nominal flow mode.

Page 6 of 10 5. Sound pressure measurements and corrections In each of the measurement positions the sound pressure level was measured for minimum 30 seconds. The background noise in the test room was measured while the dehumidifier was turned off. The measured time-averaged sound pressure levels L pa are corrected for each microphone position according to the following formula: Where L pa = L pa) - K 1A - K 3A. L pa is the energy A-weighted sound pressure level on the measuring surface, corrected for K 1A and K 3A. K 1A is the A-weighted correction for background noise level K 3A is an environmental correction depending of reflecting surroundings. The measurements were calculated and corrected in octave frequency bands 63-8000 before summing up. According to Annex A in DS/EN ISO 11202, the local environmental correction K 3A is dependent of the absorption area of the room surfaces: K 3A = 10 log (1 + 4S/A), where S is the area of a hemisphere with a radius of 1 metre: S = 2 π r 2 = 6.28 m 2. A is the total absorption area of the room: A = α S V, where α = 0.3 is an estimate of the mean absorption coefficient of the room surfaces. S V is the total area of the test room (walls, ceiling and floor), S V = 336 m 2. The value of K3A is determined to 1.0 db(a) 6. Test results 6.1 Sound pressure levels In Table 2 the measurement results are shown as the A-weighted sound pressure level in each of the four microphone positions: A-D (see illustration in Annex 1). C65E-11.1 Sound pressure levels, L pa in db re 20 µpa Measurement position A B C D Mean value Nominal flow mode 64.2 69.1 65.6 63.8 66.2 Table 2 Type C65E-11.1.Measured and corrected, averaged, A-weighted sound pressure levels L, pa in db re 20 µpa corrected for background noise (K 1A ) and the environment correction (K 3A ). The highest value was found in position B on the left side of the test object: 69.1 db(a).

Page 7 of 10 The background noise was measured in all four position positions. The average background noise was 32.0 db(a). The standard deviation of the measurements is σ R0 = 1.5 db (accuracy grade 2). The operating and mounting conditions are σ omc = 0.5 db and the total standard deviation is σ tot = 1.6 db. The expanded uncertainty U for a one-sided confidence level of 95% is U = 2.5 db. The corrected, averaged (four positions), A-weighted sound pressure levels per 1/1-octave frequency band are shown in Table 3. Condition Nominal flow mode 63 125 250 500 1000 2000 4000 8000 SUM 35.4 47.2 61.6 59.7 59.8 58.2 51.9 40.8 66.2 Table 3 Type C65E-11.1. Corrected, averaged, A-weighted sound pressure levels per 1/1-octave frequency band in db re 20 µpa.

Page 8 of 10 Annex 1 Measurement points The dashed lines show the measurement surface located at d = 1 metre from the reference box containing the test object. Four microphone positions were placed at height 1.55 m above the floor. B A C D Set-up for the sound pressure measurements (not in scale).

Page 9 of 10 Annex 2 Instrumentation Instruments and analysis software used for the sound measurements on 7 June 2016: No. Equipment Make Type Previous Calibration Next 02L019 Calibrator Brüel & Kjær 4231 6 Apr. 2016 Oct. 2016 06L059 ½ Microphone G.R.A.S 40AE 22 Jan. 2016 Jan. 2017 06L062 ½ Microphone G.R.A.S 40AE 30 Nov. 2015 Nov. 2016 06L057 ½ Microphone G.R.A.S 40AE 7 Apr. 2016 Apr. 2017 06L042 ½ Microphone G.R.A.S 40AE 21 Jan. 2016 Jan. 2017 09L031 Preamplifier G.R.A.S 26CA 8 Apr. 2016 Apr. 2018 09L043 Preamplifier G.R.A.S 26CA 21 Nov. 2014 Nov. 2016 09L042 Preamplifier G.R.A.S 26CA 21 Nov. 2014 Nov. 2016 09L039 Preamplifier G.R.A.S 26CA 21 Nov. 2014 Nov. 2016 04L008 Ref. Sound Source Brüel & Kjær 4204 23 Apr. 2015 Apr. 2018 14L002 Data aq. card National instruments NI9233 3 Dec. 2014 Dec. 2016 - Multimeter Fluke 179 - - For recording and analysis the program noiselab 3.0 and noiselab Batch Processor 3.1.1.4 from DELTA was used. The measurement set-up was calibrated before and after the measurements. All instruments are calibrated regularly in accordance with our DANAK guidelines.

Annex 3 Sound power levels for reference sound source B&K 4204 Page 10 of 10