Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis)

Similar documents
Corometrics 120 Series

Atlas Monitor Outline Train the Trainer

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

General Skills. yes. Device controls, buttons, indicators, and connectors

Corometrics 250cx Series Monitor

Vitalmax 4000 CL Product Specifications

BeneVision Central Monitoring System. Quick Reference Guide

Propaq LT Outline Train the Trainer

Connex Integrated Wall System 2.2 Software Version

CNAP MONITOR 500 HD QUICK GUIDE. This Quick Guide DOES NOT REPLACE the user manual!

Avalon Fetal Monitor

Configuration Settings Appendix

SPECIFICATION FOR MULTIPARAMETER MONITOR

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

FC1400 Operation Manual

IntelliVue Cableless Measurements

T1 BEDSIDE MONITOR GUIDELINE

INSTRUCTIONS FOR USE. IntelliVue X2. Multi-Measurement Module Release G.0 with Software Revision G.0x.xx. Patient Monitoring

Clinical Information Center Pro v5 (CIC Pro)

Operator s Manual. LifeSense LS1-9R. Vital Signs Monitor. Capnography/Pulse Oximeter

Avalon Fetal Monitor

DPM Summary of Features and Benefits

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

User s Guide. Cardell Touch Veterinary Vital Signs Monitor. For Models:

İndex SUCTION UNIT... PATIENT MONITOR HOLTER SYSTEM... 7

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

The information in this document is subject to change without notice.

MODEL 3X Series User s Manual

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

(Place Logo from Lab here)

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

OMNI TOUCH SCREEN PATIENT MONITOR

Vital Signs Monitor 300 Series

Multiparameter. er Monitor DM

BeneVision TM80 Telemetry Monitor

GIMA VITAL SIGNS MONITORS VITAL PRO-SNET

according to the European standard for medical devices 93/42/EWG, annex IX as amended by 2007/47/EC

PULSE OXIMETER PACKAGE

BEDSIDE MONITORING Dash 3000/4000 V5

Vital Signs Monitor 300 Series

Adult and paediatric ventilators. Quick Setup Guide. English

Avalon Fetal Monitor

SECTION L MONITORING EQUIPMENT

Vital Signs Monitor 300 Series

CREATIVE MEDICAL. PC-3000 Multi-Parameter Monitor

Guide, Quick Start, Short, X-100 System

QAM.L L550 series. Patient Monitor Manual QAM.L

User Guide. Cardell Insight Veterinary Monitor. For Models: 8014 Blood Pressure Blood Pressure, Pulse Oximetry

qube mini Overview

Omni (K) PATIENT MONITOR

INSTRUCTIONS FOR USE. IntelliVue Patient Monitor. MP5 Release G.0 with Software Revision G.0x.xx. Patient Monitoring

Patient Monitoring System YM5500. Service Manual

Operator s Manual. Avant Pulse Oximeter and Noninvasive Blood Pressure (NIBP) Monitor English

OPERATOR S MANUAL. NELLCOR N-200 Pulse Oximeter

Vital Signs Monitor PC-900. User Manual

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

M9500 Patient Monitor User s Manual

PERFUSION APPARATUS MODEL No: PER-5.2 USER MANUAL. Page 1 of 21

Operator s Manual. Avant Pulse Oximeter and NIBP Monitor. English

901-M / 901-ML. Pulse Oximetry System. Technical Information and Service Manual

Model 900. Pulse Oximeter User s Manual

Instructions for Use Vista 120

ARGUS LCM. Patient monitor ARGUS LCM and ARGUS LCM PLUS. Operating Instruction. Art. no.: rev.: d

CARDELL Veterinary Vital Signs Monitor

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

MRI Monitor. All-in-one monitor for the MRI environment. Features. Parameters. Accessories

Syringe Pump. User Manual

SERVICE MANUAL YM6000 Patient Monitor

CASMED 740 Vital Signs Monitor

About this Manual. Statement. Release Date: January, 2014

ANGELUS (Ver 2.03) Patient Monitoring System

THE CLINICAL CONNECTION

Operator s Manual. Avant Pulse Oximeter and NIBP Monitor. English

Central Monitor CNS Shown with options

Vital Signs Monitor. 300 Series. Directions for Use. Software Version 1.0X

About this Manual. Statement. P/N: Release Date: August 2010 Copyright EDAN INSTRUMENTS, INC All rights reserved.

5/ 5i/ 5c/ 7/ 7i/ 7c/ 5 elite/ 5i elite/ 5c elite/ 7 elite/ 7i elite/ 7c elite

V203 HANDHELD PULSE OXIMETER & TEMPERATURE MONITOR OPERATING MANUAL

T1 Patient Monitor. Operator s Manual

Veterinary Portable Multi-parameter Patient Monitor. Operation Manual

CLEO VERSATILITY IN VITAL SIGNS

OMNI. Patient Monitor USER S MANUAL

VITALOGIK= 4000 / 6000 Series Configured Patient Monitors SERVICE MANUAL FDM REV.A

I/A Series A 2 Software FoxAlert Alarm Manager

Operator s Manual. Avant Digital Pulse Oximeter. English

M8000VET /M9000VET Veterinary Monitor User s Manual

Multi-parameter Patient Monitor Operator s Manual

Operator s Manual. Models 8600FO and 8600FOM Pulse Oximeters. English

LifeSense Vet LS1-10R

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Manufacturer s Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of t

DINAMAP PRO Series V2 Monitor. Operation Manual

OMNI Express VS VERSATILITY IN VITAL SIGNS

ENSEMBLE Central Nurse Station USER MANUAL

signal extraction pulse oximeters OPERATOR S MANUAL

EMS Guide. HeartMate 3

Multi-Parameter Patient Monitor

DINAMAP ProCare Monitor. Operation Manual

SureSigns VS4 Vital Signs Monitor

PATIENT MONITORING SYSTEMS

Transcription:

Quick Reference Guide STAN S31 fetal heart monitor Important! Read the STAN S31 User Manual. 1. 2. 3. 1 2 3 4 5 6 Transducer connectors 4. Function buttons Power switch 5. Information panel Fetal ECG (FECG) average 6. Display unit Power ON/OFF Power on the monitor by setting the power switch beneath the display unit to position I. Shut down the monitor by pressing the End function button on the screen. When instructed on the screen, power off the monitor by setting the power switch to position O. Temporary ending You can end the recording temporarily. If you restart the monitor within two hours, you will be able to continue the recording. ST Analysis (Fetal ECG analysis) ST In this document, this symbol indicates information related to ST Analysis function. When monitoring with scalp electrode, the fetal ECG is recorded and ST Analysis is performed, if enabled on your monitor.

Screen layout 1 2 3 STAN S31 fetal heart monitor is available in several versions. Not all functions may be available on your monitor. 1 2 The display area is divided into three sections: 1. Information Panel - instantaneous data 2. Data presentation - trends, changes over time 3. Function buttons - menus and system functions Information panel 3 4 5 6 10 8 7 9 11 12 1. Patient data FECG average Status window Maternal window FECG signal information Maternal uterine activity 2. ST 3. 4. 5. 6. 7. FECG/US1 heart beat 8. US2 heart beat 9. FECG/US1 signal quality 10. US2 signal quality 11. FECG/US1 heart rate 12. US2 heart rate Function buttons Function buttons are located at the bottom row of the display. Depressed button indicates activated function. Shaded (gray) button or text indicates that the function is not enabled. Navigation Operate the function buttons via the LCD touch screen. Press the function button with a finger or a touchpen to activate function. Press and hold the function button to open the pop-up menu.

Data Presentation 1 2 3 4 5 6 7 8 1. Time, date and connected transducers 2. ST Event ST This symbol indicates a significant change in the fetal ECG waveform has occurred. You can find more information regarding this event in the Event Log. See STAN S31 User Manual for more information. 3. Fetal heart rate trace When no transducer is connected or when HR is not detected or out of scale, no line will be drawn. 4. Maternal heart rate trace Discontinuous or intermittent trace, presented as green rings, in order to differentiate from FHR trace. MHR is calculated from the SpO 2 measurements ( in STAN S31 monitors with maternal monitor ). 5. Event marker line (when Event marker button depressed) 6. Uterine activity trace TOCO or IUP values are shown. When no transducer is connected, no line will be drawn. 7. T/QRS ratios ST T/QRS ratios between - 0.125 and + 0.50 are drawn. 8. Biphasic (BP) indications ST Calculated biphasic indications are displayed at the bottom end of the grid. Event Log The Event Log records information about various events. The Event Log is always active, even when hidden. When an ST Event, Fetal Heart Rate Event or Maternal Event occurs, the Event Log is automatically displayed. Press the button to display or hide the Event Log. Press the button to enter an event using the keyboard. Press and hold to select a predefined event. Use the arrows in the Event Log window to move up and down in the Event Log. Important information might be missed when the event log is hidden.

Data Presentation Windows Live EFM Window This is the window you normally use when monitoring. FECG Signal Window When monitoring with scalp electrode, use this window to inspect the fetal ECG signal. This window is always displayed after power ON until STAN S31 is recording with good signal quality. In case of low or poor signal quality it may be necessary to apply a new scalp or skin electrode. The current live recording is still visible in the right side window. Press the button to display or hide the FECG Signal Window. EFM Scroll Window This window permits review of the ongoing recording. The live recording is still visible in the right side window. Press the button to display or hide the EFM Scroll Window. Move finger or touchpen across the scrollbar or across the recording to scroll through the recording. Alarms Do not base patient monitoring solely on the alarm system. Absence of alarm triggering events does not imply the wellbeing of the mother or fetus. The alarms system does not replace personal surveillance and clinical assessment of your patient. You may configure alarms on STAN S31. See STAN S31 User Manual for information on how to configure alarms. Alarm Conditions The alarm triggering conditions are grouped into Clinical Conditions and Signal Loss Conditions. When alarms are enabled, they may be configured for either Clinical Conditions only, Signal Loss Conditions only, or both Clinical and Signal Loss Conditions. See STAN S31 User Manual for more information. Alarm Signal If alarms are enabled, the alarm signal may be visual or both audio and visual. When alarm is triggered, operator confirmation is required in order for the alarm signal to cease.

Visual alarm signal Recording of the uterine activity Set-up, External - TOCO Press button to stop the visual alarm signal. Audible alarm signal Press button to stop the audible alarm signal. Inactivate/restore alarm signal Press and hold the Event Log button to access the Alarm Settings Overview. Press button Alarm Audio Off to silence alarm signal. The visual alarm signal is still active. Press button Alarm Off to inactivate alarm signal completely. All alarm signals are now inactivated. If the alarm signal is either silenced or inactivated, press button Restore Alarms to revert to the initial alarm settings. Place the transducer on the upper part of the maternal abdomen, over the fundus. Fix the transducer in position using the abdominal belt, then connect to STAN S31. Adjust the sensitivity by tightening or loosening the belt. Set-up, Internal - IUP Press the button to set the TOCO value to default value 5. Press and hold button to select sensitivity. Only use recommended cathethers and adapter cables. See STAN S31 User Manual. Follow the application instructions included with the catheter and the IUP adapter cable. Use a sterile IUP catheter of recommended type. Introduce the catheter. Connect the IUP adapter cable to STAN S31 Press the Zero IUP menu button, to zero the IUP signal. Connect the catheter to the IUP adapter cable.

Recording of the fetal heart rate X ST In external monitoring using ultrasound (US), no FECG is obtained and ST Analysis is not performed. External Recording-Ultrasound Reposition the transducer regularly as the fetus moves to improve signal quality. Always use gel for ultrasound. Direct the US transducer towards the fetal heart. Press the button to switch US Sound on/off. Press and hold to select sound volume. Fix the transducer by using the abdominal belt then connect to STAN S31. ST Internal Recording-Fetal ECG (FECG) When monitoring with scalp electrode, the fetal ECG is recorded and ST Analysis is performed, if enabled on your monitor. Only use recommended disposables and follow the instructions for use included with the disposable package. Locate the position for the skin electrode. Prepare the skin properly by rubbing with abrasive device. Clean the area with alcohol. Let dry. Connect the skin electrode to the legplate and apply to the prepared skin area. Read the STAN S31 User Manual on Signal Quality. Apply the recommended sterile scalp electrode. Connect the scalp electrode to the legplate. Connect the legplate to STAN S31 and inspect the FECG signal. The fetal ECG will automatically be displayed in FECG Signal window until a stable signal has been achieved. Press the button to switch FECG Sound on/off. Press and hold to select sound volume.

Monitoring the maternal vital signs-nibp, MSpO2 and MHR For more information see the STAN S31 User Manual. STAN S31 monitor may be equipped with an integrated maternal module. The following maternal vital signs can be monitored directly with STAN S31: non-invasive blood pressure (NIBP), oxygen saturation (MSpO2), and pulse/heart rate (MHR). NIBP is measured with an NIBP cuff, and pulse oximetry with an SpO2 sensor. MHR is derived directly from the MSpO2 measurement. Index Read and follow the NIBP cuff instructions for use. Arterie Artery Arteria Artère Read and follow the SpO 2 sensor instructions for use. Select a cuff of appropriate size.wrap the cuff snugly around the mother s bare arm. Center the arrow on the cuff directly over the brachial artery pointing towards the hand. For optimum accuracy, the mother should keep the cuffed arm in extension, with the cuffed part placed at the same level as the heart, duringthe whole measurement. Apply the sensor on a suitable location (index finger is preferred). Ensure the light emitter is facing the nail, and the finger is inserted right to the end of the sensor. Press NIBP Start button on screen in order to start the measurement. Press and hold NIBP Start button on screen. Select the desired NIBP cycle in the pop-up menu. A measurement will start right away. Press NIBP Stop button on screen in order to stop an ongoing measurement. The values of the latest NIBP measurement are presented in the Maternal Window. When the pulse oximetry sensor is correctly applied, the MSpO2 value and MHR value are presented (and updated) continuously in the Maternal Window. The Event marker The Event marker is used to indicate fetal movements or other events. Each press results in a vertical line marker in the uterine activity curve.

Printout STA P 11 n Different printer types can be connected to the system via network. See STAN S31 Service Manual for compatible printer models. Network Printer Press the button to open Print dialog. Thermal Recorder Press the button to start/stop the recorder. Press and hold to select printing options. Neoventa Medical AB Ågatan 32 431 35 Mölndal SWEDEN Tel.:+46 (0)31-758 32 00 Fax:+46 (0)31-758 32 99 www.neoventa.com www.stancases.com USA Customer Support: Tel: 1-888-777-7856 info.us@neoventa.com PRD 101 007/1 R5A 2009 Neoventa Medical AB. All rights reserved. STAN, Goldtrace and the STAN baby logo are trademarks of Neoventa Medical AB.