Fan Coil Range HYDRONIC TERMINALS
This document can be subjected to variations. Descriptions, performance data, images and diagrams are indicative only. For further information contact Climaveneta Comunications/Marketing Department or visit www.climaveneta.com
Fan Coil Range HYDRONIC TERMINALS i-life 130 640 pg. 4 Professional fan-coils with cabinet or built-in version powered by EC Brushless centrifugal fan 1,7-7,47 kw HWD 602 1104 pg. 38 Ducted type terminal 4,8-15,1 kw a-life 120 840 pg. 12 Fan-coil for professional applications, with cabinet or built-in version 1,14-11,9 kw HWD HP 0071 0121 pg. 42 High head ducted type terminal 16,8-29,8 kw a-life HP 230 840 pg. 26 High head fan-coil for professional application built-in version 2,83-10,2 kw HRD 021 151 pg. 44 Heat recuperator unit 290-4000 m 3 /h NTF 102 603 pg. 30 Residential fan-coils with cabinet or concealed version 0,86-4,25 kw CHD 506-1209 pg. 46 Cassette type terminal 2,11-9,36 kw MHD 30 60 pg. 36 Hi-wall type terminal 2,15-4,7 kw CONTROLLERS pg. 50 The wide range of available wall-mounted and built-in controllers, allows a user-friendly and complete regulation of all the functions, and an easy integration in home automation, centralization, building management systems.
4 HYDRONIC TERMINALS i-life 130 640 VERSION DFI built-in version, front air intake DFU version with cabinet, front air intake DLI built-in version, bottom air intake DLU version with cabinet, bottom air intake FEATURES PROFESSIONAL FAN-COILS WITH CABINET OR BUILT-IN VERSION POWERED BY EC BRUSHLESS CENTRIFUGAL FAN 1,7-7,47 kw Synchronous motor with permanent magnets electronic switches; Modulating centrifugal fan with fine regulation of the air flow; Four pipe system: 3+2 and 4+1 (number of rows for main + additional coil); Cabinet in galvanised steel with prevarnished finish for maximum resistance to rust; Air filter on all models; Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40); NEW i-life fan-coil is powered by modulating speed centrifugal fan. This new generation of fan-coil guarantees air flow regulation from 0% to 100% and energy consumption is reduced by more than 50% respect traditional unit. Furthermore new commands are available to manage all functions offered by this range of terminal units. L P H COMMANDS EK PLUG-IN CONTROL /EKW WALL MOUNTED CONTROL User interface for selection of functioning mode (OFF/summer/winter/AUTO), fan speed (Max/Med/Min/AUTO), temperature set. Control of main coil valve unit (summer/winter - 2 pipes installation) and additional coil (winter - 4 pipes installation). Management of traditional ON/OFF valve unit or modulating valve unit 0-10V or 3 points (supply 230 VAC or 24V). Air and water temperature probe. Multifunction digital input configurable by user. Configuration dip switch. Modbus protocol for installation in Building Management System (e.g. Idrorelax system by Climaveneta). Installation and management of Master-Slave system up to 8 LIFE fan coil units. Easy control installation thanks to 2 wires connection. IK CONTROL WITH LCD SCREEN Interface with LCD screen with user-friendly icons. Control kit for universal installation: wall-mounted as well as plug-in. Selection of functioning mode (OFF/summer/winter/AUTO), fan speed (Max/Med/Min/AUTO), temperature set. Control ik could function manually or with weekly timer regulation configurable by the customer. Control of main coil valve unit (summer/winter - 2 pipes) and additional coil (winter - 4 pipes). Management of traditional ON/OFF valve unit or modulating valve unit 0-10V or 3 points (supply 230 VAC or 24V). Parameters configurable directly by user. Modbus protocol for installation in Building Management System (e.g. Idrorelax system by Climaveneta). Installation and management of Master-Slave system up to 8 LIFE fan coil units. Easy control installation thanks to 2 wires connection. ACCESSORY Hot water coil kit 1 row and 2 rows Kit RS485 - interface for Building Management System Kit control board to manage 0-10V or 3 points modulating valve unit Additional coil valve unit ON/OFF, PWM, 0-10 V, 3 points 3-way or 2-way Main coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-way Kit LIFE BOX
5 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA i-life
6 HYDRONIC TERMINALS i-life 130 640 TECHNICAL DATA i-life
7 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA i-life
8 HYDRONIC TERMINALS i-life 130 640 TECHNICAL DATA i-life
9 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA i-life
10 HYDRONIC TERMINALS i-life 130 640 TECHNICAL DATA i-life
11 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER
12 HYDRONIC TERMINALS a-life 120 840 VERSION DFI built-in version, front air intake DFU version with cabinet, front air intake DLI built-in version, bottom air intake DLU version with cabinet, bottom air intake FEATURES ow noise centrifugal fan, with double intake and forward blade; Four pipe system: 3+2 and 4+1 (number of rows for main + additional coil); 6-speed autotransformer; Air filter on all models; Cabinet in galvanised steel with prevarnished finish for maximum resistance to rust; Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40); FAN-COIL FOR PROFESSIONAL APPLICATIONS, WITH CABINET OR BUILT-IN VERSION 1,14 11,9 kw a-life fan-coil has been specifically developed to adapt to every ambient thanks to its modern and minimal design, which is a result of the full experience and know-how Climaveneta has in this range of products. H L P COMMANDS NS PLUG-IN/NSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PS PLUG-IN/PSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MT PLUG-IN/MTW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. AT PLUG-IN/ATW WALL MOUNTED Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). CONTROL OF TRADITIONAL OR PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. ACCESSORY Hot water coil kit 1 row and 2 rows Kit RS485 - interface for Building Management System Kit control board to manage 0-10V or 3 points modulating valve unit Main coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-way Additional coil valve unit ON/OFF, PWM, 0-10 V, 3 points 3-way or 2-way Kit LIFE BOX Straight and angular (90 ) plenum kits for air inlet Straight and angular (90 ) plenum kits for air outlet Plenum kit with round air ducts for plenum kit Electric heaters
13 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA a-life / 2 PIPES
14 HYDRONIC TERMINALS a-life 120 840 TECHNICAL DATA a-life / 2 PIPES
15 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA a-life / 2 PIPES
16 HYDRONIC TERMINALS a-life 120 840 TECHNICAL DATA a-life / 2 PIPES
17 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA a-life / 2 PIPES
18 HYDRONIC TERMINALS a-life 120 840 TECHNICAL DATA a-life / 2 PIPES
19 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA a-life / 4 PIPES
20 HYDRONIC TERMINALS a-life 120 840 TECHNICAL DATA a-life / 4 PIPES
21 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA a-life / 4 PIPES
22 HYDRONIC TERMINALS a-life 120 840 TECHNICAL DATA a-life / 4 PIPES
23 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER TECHNICAL DATA a-life / 4 PIPES
24 HYDRONIC TERMINALS a-life 120 840 TECHNICAL DATA a-life / 4 PIPES
25 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL CONTROLLER LIFE BOX MODEL A LIFE BOX 100 693 LIFE BOX 200 883 LIFE BOX 300-400 1073 252 706 786 UNIT DESCRIPTION LIFE BOX is a wall-mounted accessory that allows users to prepare the fan coil water and electrical connections in advance. The fan coil is fitted inside the structure when the work has been completed, thus simplifying the operations to be performed on site. 103 103 43 A 43 The kit consists of a galvanised sheet metal structure, front closing panel and frame with manually adjustable flap. The kit is available in version painted RAL 9003 and also neutral version (raw metal sheet). LIFE BOX can house LIFE fan- coils, DLI version: low air inlet, vertical outlet. H It is available for sizes 100, 200, 300/400. L P
26 HYDRONIC TERMINALS a-life HP 230 840 VERSION DFI DLI built-in version, front air intake built-in version, bottom air intake FEATURES Four pipe system: 3+2 and 4+1 (number of rows for main + additional coil); High pressure centrifugal fan unit for ducted system; 6-speed autotransformer; Air filter on all models; Structure in hot galvanised steel for maximum resistance to rust; HIGH HEAD FAN-COIL FOR PROFESSIONAL APPLICATION BUILT-IN VERSION 2,83-10,2 kw a-life HP are professional high-head fan coils by Climaveneta. The enhanced motor and the built-in version make these units ideal for ducted systems in tertiary and commercial sectors. H L P COMMANDS NSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW WALL MOUNTED Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. ACCESSORY Hot water coil kit 1 row and 2 rows Kit RS485 - interface for Building Management System Kit control board to manage 0-10V or 3 points modulating valve unit Main coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-way Main coil valve unit ON/OFF, 0-10 V, 3 points 2-way or 3-way Straight and angular (90 ) plenum kits for air inlet Straight and angular (90 ) plenum kits for air outlet Plenum kit with round air ducts for plenum kit Electric heaters
27 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL DUCT CONTROLLER TECHNICAL DATA a-life HP
28 HYDRONIC TERMINALS a-life HP 230 840 TECHNICAL DATA a-life HP
29 2P 4P 2 PIPES 4 PIPES FANCOIL CENTRIFUGAL DUCT CONTROLLER
30 HYDRONIC TERMINALS NFT 102 603 VERSION I U version without cabinet version with cabinet FEATURES Plastic air intake and outlet grille; Very low noise fan unit; 6-speed autotransformer; Air filter on all models; Cabinet in galvanised steel for maximum resistance to rust; Automatically closing flap to cover and protect electric controls from dripping water (in conformity with directive 60335-2-40); RESIDENTIAL FAN-COILS WITH CABINET OR CONCEALED VERSION 0,86-4,25 kw Lockable control covers; Plug-in controls fixing bracket; NFT belongs to residential fan coil range by Climaveneta. This compact fan coil incorporates a tangential low noise fan. They are designed for residential market and small tertiary installation. Wall-mounted LIFE controls: NSW, PSW, MTW, ATW could be connected. NFT participates to EUROVENT certification programme. L P H COMMANDS H NSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW WALL MOUNTED Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. CE PLUG-IN Control for plug-in installation on fan coil. Off/summer/winter/auto selector switch. Three speed/auto selector switch. Thermostat with set point regulation. Air and water probe. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). PCE WALL-MOUNTED Off/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control. L ACCESSORY Pair of decorative and structural feet Air intake grille kit with version cover IR reciver for CE comand with remote control Interface SPB Kit Rear panel for vertical housing Horizontal and vertical fan coil auxiliary tray Hose kit In-line delivery plenum kit Front air intake plenum for built-in version Manual external air intake lock kit Main coil valve unit ON/OFF, PWM Additional coil valve unit ON/OFF, PWM P
31 2P 4P 2 PIPES 4 PIPES FANCOIL TANGENTIAL CONTROLLER TECHNICAL NFT / U DATA NTF
32 HYDRONIC TERMINALS NFT 102 603 TECHNICAL NFT / U DATA NTF
33 2P 4P 2 PIPES 4 PIPES FANCOIL TANGENTIAL CONTROLLER TECHNICAL NFT / U DATA NTF
34 HYDRONIC TERMINALS NFT 102 603 TECHNICAL NFT / U DATA NTF
35 2P 4P 2 PIPES 4 PIPES FANCOIL TANGENTIAL CONTROLLER
36 HYDRONIC TERMINALS MHD 30 60 VERSION - base version FEATURES Fan coil in ABS with high mechanical characteristics and resistance to ageing; Adjustable air flow direction; Arrangement for right-left condensate drain pipe; Removable panel; Management of all functions by remote control HI-WALL TYPE TERMINAL 2,15-4,70 kw MHD belongs to hi-wall fan-coils of Climaveneta. The compactness of this model and its exclusive elegance soften the visual impact and make it ideal for residential and small tertiary installations. H L P COMMANDS REMOTE CONTROL Set-point regulation. Selection of functioning mode (cool, heat, dehumidify, fan), fan speed (Max, Med, Min, AUTO). Main available function: Swing, Sleep, Timer. User-sfriendly compact remote control with fine aethetics. ACCESSORY Frame kit Solenoid valve 2 ways 1/2" Solenoid valve kit 3 ways, 4 fits 1/2" with frame Condensate drain pump
37 2P 2 PIPES WALL TANGENTIAL CONTROLLER TECHNICAL NFT / U DATA MHD
38 HYDRONIC TERMINALS HWD 602 1104 VERSION - base version FEATURES DUCTED TYPE TERMINAL 4,8-15,1 kw HWD are Climaveneta ducted hydronic terminal units. The fan units at available working pressures, through internal insulation, ensure excellent acoustic comfort levels. The compactness and ease of installation make HWD a suitable hydronic terminal unit for any type of setting. Unit coils guarantee high efficiency thermal exchange with low pressure drop. Finned unit coils are made of copper tubes and high exchange surface area aluminium fins. Coils are always tested for leaks with dried air at 30 bar; The electrical power and control switchboard includes electronic air flow regulator and terminal blocks for connection to power supply and remote control; Internal insulation in closed cell expanded polyethylene with suitable thick to limit heat loss and noise emission; The fan units, with high available working pressures, are fitted with balanced impellers to guarantee maximum acoustic comfort. Structure and base plate in hot-dip galvanised steel for maximum resistance to rust; Extra modules available as accessories to the standard unit; Remote control to manage main unit functions to provide a total enviroment comfort. Full Auto function; Arrangement for electronic control of two on/off or modulating valve unit in the water circuit; COMMANDS NSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. ATW WALL MOUNTED Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). L P H PSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. PCE WALL-MOUNTED Off/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control. ACCESSORY Interface SPB Kit Hot water coil kit Air purifier module with actived carbon filter Heating element module Humidifier module Delivery and intake plenum Delivery plenum for round ducts Two way intake plenum with air lock Condensate drain pump
39 2P 4P 2 PIPES 4 PIPES CENTRIFUGAL CONTROLLER TECHNICAL HWD DATA HWD
40 HYDRONIC TERMINALS HWD 602 1104 TECHNICAL HWD DATA HWD
41 2P 4P 2 PIPES 4 PIPES CENTRIFUGAL CONTROLLER
42 HYDRONIC TERMINALS HWD HP 0071 0121 VERSION - base version FEATURES HIGH HEAD DUCTED TYPE TERMINAL 16,8-29,8 kw Unit coils guarantee high efficiency thermal exchange with low pressure drop. Finned unit coils are made of copper tubes and high exchange surface area aluminium fins. Coils are always tested for leaks with dried air at 30 bar; The electrical power and control switchboard includes electronic air flow regulator and terminal blocks for connection to power supply and remote control; Internal insulation in closed cell expanded polyethylene with suitable thick to limit heat loss and noise emission; Cabinet in galvanised steel for maximum resistance to rust; Extra modules available as accessories to the standard unit; HWD HP belongs to ducted type fan-coils high head of Climaveneta. The possibility of vertical or horizontal installation, airflow adjustment and attractive external panelling guarantees an ease installation and make the unit adaptable to any type of surroundings. COMMANDS NSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW WALL MOUNTED Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. PCE WALL-MOUNTED Off/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control. L ACCESSORY Interface SPB Kit Hot water coil kit Heating element module Delivery and intake plenum Intake grill Two way intake plenum with air lock Ceiling brackets Auxiliary condensate collecting tray P H
43 2P 4P 2 PIPES 4 PIPES CENTRIFUGAL CONTROLLER TECHNICAL HWD DATA HWD HP
44 HYDRONIC TERMINALS HRD 021 151 VERSION - base version FEATURES HEAT RECUPERATOR UNIT 290-4000 m 3 /h HRD heat recuperator units for residential and commercial application allow maximum room comfort and energy saving. In modern systems is becoming necessary to create forced ventilation, which involves air conditioned expelling; thereby consuming more energy and consequenting increasing costs. HRD heat recuperators have obviated such as problems using an aluminium static recovery unit that saves more than 50% energy, otherwise be lost with expelled stale air. HRD can be integrated in traditional systems with fan coils, chillers and radiators and may operate both in summer and winter. These units are recommended for suspended ceiling installation and may be suitably ducted to allow the fresh air intake and distribution. Removable aluzink plate side panels; Panels insulated and soundproofed with polyethylene/polyester with average thickness of 10 mm (mod. HRD 0021-0051) and 20 mm for the other models; High efficiency aluminium plate static type heat recovery units, with airflow separated by special seals; UE3 efficiency air filters, which may be easily removed from any side of the unit (bottom, side, top) for periodic cleaning; Fan casings on vibration-isolation mountings; Double inlet centrifugal fans for fresh air intake and used air extraction, which may be removed from any side of the unit for periodic maintenance; Multi speed directly coupled electric motor; A terminal block with a relay board is fitted on the unit to aid electrical connections and fan control; Stainless steel condensate collecting tray, with condensate drain directed downwards; COMMANDS NSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. MTW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW WALL MOUNTED Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. PCE WALL-MOUNTED Off/summer/winter/auto selector switch. Room temperature control. Room temperature sensor. Coil temperature sensor. Three speed air flow control + Auto. Automatic summer/winter switching. Automatic ON/OFF valve control. L ACCESSORY Interface SPB Kit Hot water coil kit Cool water coil kit Heating element kit P H
45 PLATE CENTRIFUGAL CONTROLLER TECHNICAL HWD DATA HRD
46 HYDRONIC TERMINALS CHD 506-1209 VERSION U-2T U-4T electromechanical version for 2-pipe system electromechanical version for 4-pipe system FEATURES CASSETTE TYPE TERMINAL 2,11-9,36 kw Unit coils guarantee high efficiency thermal exchange with low pressure drop. Finned unit coils are made of copper tubes and high exchange surface area aluminium fins. Coils are always tested for leaks with dried air at 30 bar; Electrical power and control switchboard, complete with electronic air flow regulator and terminal board for connection to network and available remote controls; Internal insulation in closed cell expanded polyethylene with suitable thick to limit heat loss and noise emission; Availability to have fresh air intake, distribute air flow in four directions and also in different room place thanks to air diffuser present on the unit; Condensate auxiliary tray standard supplied; New CHD fan-coil cassette of Climaveneta, electro-mechanical unit, is available in two version: for two pipe installation (unit with single coil) and for four pipe installation (unit with double coil). Wide range of sizes and easy installation make them suitable for all types of installations. COMMANDS H NSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Setting for minimum temperature thermostat. PSW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Remote water temperature probe. MTW WALL MOUNTED Fan speed slider, mode slider (OFF/summer/winter). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Room temperature probe. Remote water temperature probe. ATW WALL MOUNTED Mode button (OFF/summer/winter/AUTO), fan speed button (Max/Med/Min/AUTO). Thermostat with set point regulation. ON/OFF valve unit control (summer/winter for 2 pipes installation), ON/OFF second valve unit control (winter for 4 pipes installation). Control of traditional or PWM modulating valve units. Room temperature probe and water temperature probe. Digital input configurable as: window contact, economy, heating or cooling remote changeover, periodic ventilation. Configuration dip switch. TTL serial port with Modbus protocol for installation in Building Management System. L ACCESSORY Air duct connection kit Main coil 2-way/3-way valve unit Additional coil 2-way/3-way valve unit P
47 2P 4P 2 PIPES 4 PIPES CENTRIFUGAL CONTROLLER TECHNICAL HWD DATA CHD
48 HYDRONIC TERMINALS CHD 506-1209 TECHNICAL HWD DATA CHD
49 2P 4P 2 PIPES 4 PIPES CENTRIFUGAL CONTROLLER
50 HYDRONIC TERMINALS CONTROLLERS THE WIDE RANGE OF AVAILABLE WALL-MOUNTED AND BUILT-IN CONTROLLERS, ALLOWS A USER-FRIENDLY AND COMPLETE REGULATION OF ALL THE FUNCTIONS, AND AN EASY INTEGRATION IN HOME AUTOMATION, CENTRALIZATION, BUILDING MANAGEMENT SYSTEMS. NS plug-in NSW wall mounted Fan speed slider, mode slider, minimum temperature thermostat and command of on/off valves AT plug-in ATW wall mounted Room thermostat, manualand automatic regulation of fan, manualand automatic mode change-over, roomand minimum temperature probes and command of on/off valves. Multifunction digital contact. Configuration dip switch. PS plug-in PSW wall mounted Fan speed slider, mode slider, minimum temperature probe and regulation of on/off valves MT plug-in MTW wall mounted Room thermostat, fan speed slider, mode slider, room- and minimum temperature probes and regulation of on/off valves EK plug-in EKW wall mounted Room thermostat, manualand automatic regulation of fan, manual- and automatic mode, change-over, roomand minimum temperature probes, regulation of electric heater, valves (on/off or modulating), serial connection for mini-network and integration into BMSor Idrorelax systems ik universal Electronic control with LCD display, room thermostat, manual and automatic regulation of fan, manual- and automatic mode change-over, room and minimum temperature probes, regulation of electric heater, valves (on/off or modulating), 0-10 V output for the regulation of the energysaving brushless fan motor, serial connection for mininetwork and integration into BMS or Idrorelax systems Notes Refer to the dedicated product's pages for more information about compatibility between the controllers and the single fan coil. The ik, EK, EKW controllers installed with a-life and a-life HP have to be combined with the 'HB LIFE' power board (cod. 7349051500).
51 MULTIPLE CONNECTION HYDRONIC TERMINALS MODEL SIZE NS-NSW (1) PS-PSW (1) MT-MTW (1) AT-ATW (1) SPB (2) SPB (3) Input * a-life 100 8 8 8 3 15 9 0,29 200 8 8 8 3 15 9 0,3 300 8 8 8 3 15 9 0,31 400 4 4 4 1 15 5 0,56 500 4 4 4 1 15 4 0,6 600 4 4 4 1 15 4 0,6 700 2 2 2 1 15 3 0,87 800 2 2 2 0 15 2 1,2 a-life HP 200 3 3 3 1 15 4 0,64 400 4 4 4 1 15 5 0,56 500 2 2 2 1 15 3 0,95 700 2 2 2 0 15 2 1,1 800 2 2 2 0 15 2 1,25 NFT I - U 102 8 8 8 4 15 12 0,23 202 8 8 8 4 15 12 0,23 302 8 8 8 3 15 11 0,25 402 8 8 8 3 15 11 0,25 502 6 6 6 2 15 8 0,35 603 6 6 6 2 15 6 0,35 CHD 506 5 5 5 2 15 6 0,4 606 4 4 4 1 15 5 0,5 706 3 3 3 1 15 4 0,7 809 3 3 3 1 15 4 0,67 909 3 3 3 1 15 14 0,69 1109 2 2 2 1 15 3 0,92 1209 2 2 2 1 15 3 0,93 HWD 602 1 0 0 0 15 1 1,3 703 1 0 0 0 15 1 1,3 803 1 0 0 0 15 1 1,55 904 1 0 0 0 15 1 1,55 1003 0 0 0 0 0 0 3,5 1104 0 0 0 0 0 0 3,5 HWD-HP 71 0 0 0 0 0 0 2,9 91 0 0 0 0 0 0 2,9 101 0 0 0 0 0 0 7,9 121 0 0 0 0 0 0 9,5 Notes (1) Maximum number of units of the same model that can be connected to a single controller (2) Maximum number of units of different models and sizes that can be connected to a single controller (installing a SPB kit in each unit) (3) Maximum number of units of the same size and model that can be connected to a controller (installing a single SPB kit) (*) Current consumption of each unit in (A)
FAN COIL RANGE_05-2012_EN_00