Preamplifier Power Supply PPS-02 user's guide

Similar documents
Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

IR detection module VPAC-1000F user's guide

IR detectors user's guide

ion Genesis Pump Controller

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Compact Equipment Warranty Policy

6502B RF Distribution

Series: MBC1-TC Mini Benchtop Temperature Controller

OPERATION AND INSTALLATION MANUAL

External Wireless Sounder

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Duct Mount. Installation Instructions

Installation and Operations Manual

External Wireless Sounder

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

VX SERIES Wireless Thermostat with Occupancy Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL

CD6102 / CD6102 OC / CD6102-2

(HSTAT Series) Instruction Manual

Air Pump Up to 800 gallons

Owner s Manual. PIR-1 IR Learner

HotPoly Tote Tank / IBC Heaters (TTH Series)

EQUIPMENT Operation Manual

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

CT2 Retro Box Installation Instruction Manual

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Energedry Elite Eliminator Pest Control Electric Heat System

Operation Manual Vortex mixer unitexer 1

Light Construction Equipment Consumer Warranty Policy

Operation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N

Horizontal Bottle Cooler Installation and Operation Manual

EQUIPMENT Operation Manual

I.D.L. Heaters Thermal Products Ltd. Roll n Warm Installation Manual

CHARGED PLATE DETECTORS

AMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

PIR Sensor. User s Guide

Expanded Backup Control Installation & Operator s Instruction Manual

Environmental Monitoring Card

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Energedry Eliminator 52K

Environmental Monitoring SmartSlot Card

USER S OPERATING AND INSTRUCTION MANUAL

View the expanded manual: GEN5

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

Sound Cover [ , , , ]

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

GETZ MANUFACTURING PART # CYLINDER DRYER

MaxLite LED Vapor Tight Linear Fixture

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Industrial Communications System Page/Party Flush-Mount Subset

A2Z Ozone, Inc. PRODUCT MANUAL

Remote Vehicle Control System

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

Radial 8 Heater For Professional use only

EQUIPMENT Operation Manual

MaxLite LED MICRO-T PANEL

OPERATING INSTRUCTIONS

Reacti-Therm I and III Heating Modules

MN908 No. 282C Replaces 282B LB7013

TrueClean ToteCleaner

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Industrial Vacuums, Inc

Multiple Boilers Electro TS Series Application EB-C-STG5


AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Model NT20e Installation Guide

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

OPERATION & INSTALLATION MANUAL

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

DIGITAL STEEL FIRE & SECURITY

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Spy Jeepmeter ope rati ng instructions

Installation & Operation Manual

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

ALM100 Alarm Module. User s Manual

Heater Installation Kit

Ella Gel Coat Walk In Tub E SERIES OWNER'S MANUAL

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

HEAT ON THE GO CORDLESS HEAT POD TYPE M2701

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

RSA2CL6SS model pictured

Transcription:

Preamplifier Power Supply PPS-02 user's guide 1

Table of contents 1. Warranty... 3 2. PPS-02 overview... 4 2.1. PPS-02 parameters... 4 2.2. Coding the symbol of the power supply...4 2.3. PPS-02 physical dimensions... 5 2.4. PPS-02 supplying... 5 2.5. Connectors... 6 2.6. Sample kit wiring... 7 3. Getting started regards complete IR detection kit...8 3.1. Unpacking... 8 3.2. Installation & connections... 8 3.3. Switching on procedure... 8 4. PPS-02 other related information... 9 4.1. CE Statement of conformity... 9 4.2. Electromagnetic interference... 9 4.3. Operating temperature... 9 4.4. Storage information... 9 5. Safety instructions... 10 2

1. Warranty VIGO System S.A. hereby represents and warrants all Products manufactured by VIGO and sold hereunder to be free from defects in workmanship or material during a period of twelve (12) months from the date of delivery save for products for which a special warranty is given. If any Product proves however to be defective in workmanship or material within the period herein provided VIGO System undertakes to the exclusion of any other remedy to repair or at its own option replace the defective Product or part thereof free of charge and otherwise on the same conditions as for the original Product or part without exten sion to original warranty time. Defective parts replaced in accordance with this clause shall be placed at the disposal of VIGO. VIGO also warrants the quality of all repair and service works performed by its employees to products sold by it. In case the repair or service works should appear inadequate or faulty and should this cause malfunction or nonfunctioning of the product to which the service was performed VIGO shall at its free option either repair or have repaired or replace the product in question. The working hours used by employees of VIGO for such repair or replacement shall be free of charge to the client. This service warranty shall be valid for a period of six (6) months from the date the service measures were completed. This warranty is however subject to following conditions: 1. 2. A substantiated written claim as to any alleged defects shall have been received by VIGO System within thirty (30) days after the defect or fault became known or occurred, and The allegedly defective Product or part shall, should VIGO so require, be sent to the works of VIGO or to such other place as VIGO may indicate in writing, freight and insurance prepaid, properly packed and labeled. This warranty does not however apply when the defect has been caused through 1. 2. 3. 4. 5. 6. 7. 8. 9. normal wear and tear or accident; misuse or other unsuitable or unauthorized use of the Product or negligence or error in storing, maintaining or in handling the Product or any equipment thereof; wrong installation, assembly or failure to service the Product or otherwise follow VIGO's service instructions including any repairs or installation or assembly or service made by unauthorized personnel not approved by VIGO or replacements with parts not manufactured or supplied by VIGO; modifications or changes of the Product as well as any adding to it without VIGO's prior authorization; burned active element by irradiation above damage thresholds electrostatic discharges improper detector bias improper TE cooler bias (TE cooler damage or active element overheating). other factors dependent on the Customer or a third party. Notwithstanding the aforesaid VIGO System liability under this clause shall not apply to any defects arising out of materials, designs or instructions provided by the Customer. This warranty is expressly in lieu of and excludes all other conditions, warranties and liabilities, expressed or implied, whether under law, statute or otherwise, including without limitation any implied warranties of merchantability or fitness for a particular purpose and all other obligations and liabilities of VIGO or its representatives with respect to any defect or deficiency applicable to or resulting directly or indirectly from the Products supplied hereunder, which obligations and liabilities are hereby expressly canceled and waived. VIGO's liability shall under no circumstances exceed the invoice price of any Product for which a warranty claim is made, nor shall VIGO in any circumstances be liable for lost profits or other consequential loss whether direct or indirect or for special damage. RMA Request Instructions: No Product may be returned without first contacting VIGO for a Return Material Authorization ('RMA') number. Please obtain a RMA number at claim@vigo.com.pl before returning any item. When requesting a RMA number, please state your order number, the product you wish to return and the reason for return. We will only accept returns which have a RMA number. Authorized returns are to be shipped according to received instruction from VIGO in appropriate shipping box. An unauthorized return, i.e. one for which an RMA number has not been issued and authorized returns however, shipped with incorrect customs documents - will not be accepted. Please print the RMA number clearly on the return label to avoid any delay in processing. Please send package to: VIGO System S.A. 129/133 Poznanska St., PL 05-850 Ozarow Mazowiecki Poland 3

2. PPS-02 overview The PPS-02 (Preamplifier Power Supply) is an universal power adapter especially suited to supply IR modules with non cooled detectors. Its modern architecture, compact size and low noise level make the usage simple and convenient. The PPS-02 is powered with power supply adapter converting the mains voltage to the save low voltage. Features: Compact size Modern architecture Low cost Easy to use Low power consumption Low noise level Electrical isolation between input ant output 2.1. PPS-02 parameters Parameter Value Unit Input voltage ± 0,01 V Output voltage ±9, ±12, ±15, +12/-5 V 100 ma Output current 2.2. Coding the symbol of the power supply Sample symbol of the PPS-02 power supply PPS-02 - xx 09 power supply ±9 V / ±100 ma 12 power supply ±12 V / ±100 ma 15 power supply ±15 V / ±100 ma G1 combined power supply ( 5 V, +12 V and +7 V) for VPAC-1000F Preamplifier 4

2.3. PPS-02 physical dimensions Dimension are given in millimeters. 2.4. PPS-02 supplying The PPS-02 module requires external power adapter converting the mains to the 5 V. Currently used type is SA115C-05, manufactured by Nordic Power. More details can be found >> HERE <<. Power supply may be changed without notification. 5

2.5. Connectors The picture below shows the pin configuration of the module. DB9 Pin Symbol 3 GND Power ground 6 -VSUP Power supply output (-) 7 +FAN FAN power supply output (+) 9 +VSUP Power supply output (+) 6

2.6. Sample kit wiring MIPXC-xx module with uncooled detector AMP 2x4 DB9 Power supply adaptor PPS-02 power supply SMA BNC signal cable 7

3. Getting started regards complete IR detection kit 3.1. Unpacking Before unpacking, verify if there are no visible damages of the package. Report them to the manufacturer or the distributor. 3.2. Installation & connections Mount the IR module in the measurement setup, Connect all elements with cables provided in the package, Make sure that all the elements are properly connected. 3.3. Switching on procedure Do not switch on the IR module power supply until ALL elements of the IR detection kit are properly connected with the proper cables. Switch on the thermoelectric cooler controller and wait until detector operating temperature is reached and stabilized. Ready state will be indicated by the LOCK green LED light. Before starting the measurements make sure the load resistance is valid. IR detector module output should be terminated by 50Ω or 1MΩ resistance depending on the bandwidth and is given in the test data provided on the module. Do not manipulate any connectors on the active IR kit this may introduce additional noises to the system or can cause severe damages due to electrostatic discharges. 8

4. PPS-02 other related information 4.1. CE statement of conformity VIGO System declares that IR detection kit is fully compliant with: EU Low Voltage Directives: 73/23/EEC, 93/68/EEC EU Electromagnetic Compatibility Directives: 89/336/EEC, 91/263/EEC, 92/31/EEC, 93/68/EEC 4.2. Electromagnetic interference To avoid the electromagnetic interferences (EMI), please do not put any electromagnetic source close to the IR module. That may cause interference to the input of the preamplifier and disturb the useful signal in the IR track 4.3. Operating temperature Detector parameters are guaranteed for the environment temperature not exceeding 35 OC. 4.4. Storage information To ensure reliable operation and long lifetime of detector, the following conditions should be fulfilled: Storage temperature: -10ºC + 50ºC and 10% to 90% humidity, Avoid exposing to direct sunlight and strong UV/VIS light as this may result in degradation of a detector performance, Avoid electrostatic discharges (ESD), 9

5. Safety instructions To ensure safe and failure-free operation of the PPS-02 power supply, comply with the following precautions: Before connecting the power supply to the mains, make sure it is compatible with the mains voltage and fre quency. The power supply is intended for the indoor use. Do not use the power supply if the temperature and the air humidity extends the values valid for the PPS-02. Use the proper cables to connect elements of the kit, dedicated for specified device only. Never cut or shorten any cable, it may cause damage to your device. Use the cables delivered by VIGO. In case of OEM systems, make sure the the cables match the specifica tion of the controller. Turn off the power supply before plugging / unplugging cables. Avoid static discharges. Important note! If you are setting up own system supplied by the the custom power supply adaptor, please make sure, the voltage/current matches to the values of the supply requirements of the PPS-02. 10