Ruhrpumpen Fire Systems

Similar documents
swp Self-priming pump for solids handling applications

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

GRUNDFOS FIRE PUMP SYSTEMS PEERLESS ENGINEERED SYSTEMS LISTED

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF. Vertical Submersible Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Fire Protection Pumps

FIRE PROTECTION SYSTEMS FULL RANGE EXPERTISE. Vertical Turbine Fire Pumps UL and FM approved GRUNDFOS FIRE PROTECTION SYSTEMS

SECTION FIRE PUMP AND CONTROLS

SECTION Fire Pumps

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

FULL RANGE EXPERTISE FIRE PUMPS FOR EVERY STANDARD

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

RUHRPUMPEN SELECTION GUIDE. Specialist for Pumping Technology I N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

RUHRPUMPEN SELECTION GUIDE. Specialist for Pumping Technology I N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

ROWA -HP High-Pressure Centrifugal Pump

ACCURATE PREDETERMINED COST

Fire Pump Specification

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

Industrial. Solutions brands you trust. Product Overview

Flow Control for Fire Protection

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

Full-line Product Overview

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Flow Control for Fire Protection

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

SECTION FIRE-SUPPRESSION STANDPIPES

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

A. This section includes design and performance information for fire protection and suppression systems.

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

SPRINKLER SYSTEM SOLUTIONS. Water-based Fire-Fighting Sprinkler System PROVEN TECHNOLOGY

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

6-30 Vertical Deep Well. Close Coupled Vertical Turbine Submersible Turbine. Pump Type. Application. Description. Materials

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION STEAM CONDENSATE PUMPS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

DIVISION 21 - FIRE SUPPRESSION

MARINE. High efficiency pumps you can rely on

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

MARLOW PUMPS RECIRCULATION

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

DIVISION 21 - FIRE SUPPRESSION

CLA-VALTM. Fire Protection Solutions: Automatic Control Valves for protecting life and property. For Commercial and Offshore Applications

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Unequaled I Unrivaled I Performance

Flygt centrifugal grinder pumps

CNS CENTRIFUGAL MULTISTAGE WATER DESCALING PUMPS BB4 TYPE API 610 ENGINEERING FLOW SOLUTIONS

SECTION FIRE PROTECTION

Reliable, effective, and powerful fire protection

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

MORE THAN JUST FIRE PROTECTION

Electric Submersible Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SECTION DRY-PIPE SPRINKLER SYSTEMS

Goulds Large Capacity, Single Stage, Double Suction Pump

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

HIGH-RISE RETROFIT ORDINANCES - NO and NO

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y HVN. Double Suction, Heavy Duty API 610 Process Pump (BB2)

IMMERSIBLE PUMPS FOR INDUSTRY

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

Wilo IL Vertical Split-Coupled Inline Pumps

MORE THAN JUST FIRE PROTECTION

Foam Systems U.S. Quick Reference Guide

DIVISION 21 FIRE SUPPRESSION

Multifunction pump for handling gaseous liquids in process engineering

2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Abu Dhabi Conformity Assessment Scheme for Fire Pumps

Tankless On Demand Electric Water Heater

HIGH PRESSURE DOUBLE CASE PUMPS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

Transcription:

FIRE SYSTEMS

RP FIRE SYSTEMS Ruhrpumpen Fire Systems Fire pumps play a vital role as the first response to a fire situation, saving countless lives and property from destruction. They are usually found in manufacturing and industrial facilities, housing complexes, power plants, schools, hospitals, airports, commercial buildings and offshore oil platforms. A fire pump is the component responsible for supplying the adequate water pressure to fire sprinklers and hose standpipes in order to control or contain a fire. Ruhrpumpen s centrifugal pumps combine the latest in hydraulic design with decades of application experience to meet today s fire security requirements. Per NFPA-20, we are able to supply ranges from 25 GPM up to 5000 GPM with net pressures of 40 PSI or more. Our fire pumps are available as single pumping units or complete pre-packaged fire systems (with or without full enclosure). Ruhrpumpen is your single source supplier Original Equipment Spare parts Installation and startup support Repair and maintenance Engineering, training and consulting Benefits of our pumps: Single source responsibility and service Proven reliability High efficiency designs ensure lowest operating cost Robust design allows for long system life with minimal maintenance Optimized total cost of ownership The combination of our engineering team, ISO 9001 manufacturing team, outstanding design, and quality construction, all ensure Ruhrpumpen s fire pumps and systems have strong reliability in case of an emergency. Ruhrpumpen s Global Service Network provides all forms of field services (start-up support, inspection, maintenance, and much more) no matter where your site is located. Time and space saving Our cost-effective packaged fire systems save you time and space as they can be dimensioned to precisely fit the specified area facilitating its installation. The system is delivered on a single shipment, leaving only pipe and power connections to be completed on site. Fully customizable 2 In order to match the specific requirements of any application, our engineering team can design complete pre-packaged fire pump systems that can vary from a fire pump with an electric driver on a skid, to a fully prefabricated unit with environmental enclosures.

Before it s painted red... Nothing is left to chance with a Ruhrpumpen fire pump system. It is completely built, tested and certified in our facility, ensuring that the stringent requirements of of governing bodies such as the National Fire Protection Association (NFPA), Factory Mutual (FM), Underwriter s Laboratories (UL) and Electrical Testing Laboratories (ETL) are met. As per NFPA-20, each pump is tested at our manufacturing facilities to provide detailed performance data and to demonstrate its compliance with the required specifications. During the manufacturing and assembly processes, each pump goes through meticulous production controls, inspections and tests. We inspect all fire suppression equipment through advanced testing techniques and precise calibration instruments that enable us to guarantee that their operation complies with the required standards. Calculations for bearing life, bolt stress, shaft deflection and shear stress must be submitted and approved by UL & FM. Casing hydrostatically tested two times rated maximum working pressure. Performance testing witnessed by UL & FM representatives. Quarterly follow-up audits of product and facilities is conducted by both UL & FM. Drawings of any component on the Primary Materials list must be approved before any change transpires. 3

RP FIRE SYSTEMS Ruhrpumpen Fire Pumps: the heart of your fire protection system Construction materials Our fire pump components such as casing, impeller, shaft and bowls, are available in standard and special metallurgies to address specific applications. Standard materials include: Cast iron Ductile iron Carbon steel Metallurgies available for sea/ brackish water applications and harsh environments: Stainless steel Duplex Super Duplex Nickel-Aluminum-Bronze Split case fire pump Horizontal, single and two stage, split case centrifugal pumps Characteristics Flows from 150 to 5000 GPM Pressures from 40 to 355 + PSI Electric or Diesel driven UL-448 listed FM-1311 approved NFPA-20 design End suction fire pump Horizontal, single stage, end suction centrifugal pumps Characteristics Flows from 150 to 400 GPM Pressures from 40 to 250 + PSI Electric or Diesel driven UL-448 listed FM-1319 approved NFPA-20 design Benefits Ease of installation and maintenance Wide range of applications Construction materials for seawater service are available Benefits Back pull-out design simplifies maintenance and reduces problems associated with pipe strain 4

Vertical turbine fire pump Vertical, single and multi-stage, turbine pumps Characteristics Flows from 250 to 5000 GPM Pressures from 40 to 519 + PSI No priming Adaptability to water level Electric or Diesel driven UL-448 listed FM-1312 approved NFPA-20 design Benefits UL listed and FM approved pump for suction lift conditions Minimal maintenance Can be used where city water is not available and ponds or lakes are the only water supply Construction materials for seawater service are available In-line fire pump Vertical in-line centrifugal pumps Characteristics Flows from 150 to 1000 GPM Only available with electric drive Pending UL Listing and FM Approval NFPA-20 design Benefits Top pull-out design simplifies maintenance Compact, space-saving design Jockey pump Pressure maintenance jockey pumps are available as vertical multi-stage and end suction pumps Characteristics Jockey pumps are normally sized for 1% flow and a 10 to 20 PSI higher pressure of the fire pump Maintains system pressure to prevent the main fire pump from starting when small leaks occur Benefits Versatility in performance and design Low operating cost 5

RP FIRE SYSTEMS Packaged Fire Pump Systems Our fire protection pumping solutions can be found all around the world in a variety of industrial, commercial and residential applications. RP s pre-packaged fire systems are tailored and built to the requirements of the customer ensuring that they meet international and local safety regulations. Our pre-packaged systems accommodate any of the RP fire pump models, with drivers, control systems and pipework on a common base for a plug-and-play installation. They can be skid mounted, with or without enclosure, and supplied with electric motor or diesel engine. Pre-packaged fire system, diesel driven, with split case pump 1. UL-142 Double Wall Day Tank 2. UL Listed Jockey Pump Controllers 3. UL/FM Fire Pump 4. FM Flow Meter 5. Throttling Valve 6. Electric Motor 7. UL/FM Electric Control Panel 8. Jockey Pump 9. Tamper Switches 10. UL/FM Listed OS&Y Gate Valves 11. Copper Sensing Lines 12. Schedule 8-CPVC Containment Piping for Fuel Piping 13. UL/FM Listed Diesel Engine 14. ASTM A36 Structural Steel Skid 15. UL/FM Diesel Control Panel 16. Floor Drain System 8

Other (optional) features of Ruhrpumpen s Pre-Packaged Fire Systems: Our marine fire suppression systems offer high performance coating systems for corrosive or coastal environments Stainless piping for seawater or brackish water applications NFPA-20 compliant mobile pre-packaged fire systems are available ABS certification for offshore platform fire pump packages and fire skid units Leveling bolts Custom alarm panels Individual split case pump baseplate with on-skid control panel 9

RP FIRE SYSTEMS NFPA-20 compliant Fire Pump Houses Completely pre-assembled and fully enclosed packages for a trouble-free and quick installation Our packaged systems can be contained on a weatherproof, non-combustible enclosure engineered and constructed per NFPA-20 and including: Heating and ventilation Approved or listed source of heat Normal and emergency lighting Drainage Convenience outlet Optional features: Pre-wired and pre-piped Pre-piped sprinkler systems for pump house interior Exhaust fan Mini power zone Wall or floor access for piping Containment piping Architectural finishes Safety equipment Grating floor deck design Seismic calculations with PE Stamps Open skid design Diamond plate floor deck design UL Listed and FM Approved pumps ETL listed Single shipment delivery, ready for installation Plug-and-play installation Single source responsibililty for complete pump house Engineered to customer requirements 10 General arrangement of a NFPA-20 compliant fire pump house.

Control Panels When there s an emergency, it s better to count on a reliable fire pump controller. Ruhrpumpen can offer electric, diesel and jockey control panels; which are available for configurations with one or more drivers, and programming for fully automatic or manual operation types. Electric and diesel control panels are UL/ULC listed and approved by FM and CSA, as well as meeting or exceeding the requirements of NFPA-20 and NFPA-70. Electric panels Low voltage configurations include: Across the line Soft start Delta open / closed Primary resistor Auto-transformer Part winding Medium voltage configuration: Across the line Diesel panels Diesel control panels are available for 12 volt (120, 220/240 VAC) diesel fire pump engines. Jockey panels Single or three phase jockey fire pump panels designed for 50 & 60 Hz in a variety of voltages. 11

+65 years creating the pumping technology that moves our world Ruhrpumpen is an innovative and efficient pump technology company that offers highly-engineered and standard pumping solutions for the oil & gas, power generation, industrial, water and chemical markets. We offer a broad range of centrifugal and reciprocating pumps that meet and exceed the requirements of the most demanding quality specifications and industry standards such as API, ANSI, UL, FM, ISO and Hydraulic Institute. Ruhrpumpen Plants ARGENTINA, Buenos Aires BRAZIL, Rio de Janeiro CHINA, Changzhou EGYPT, Suez GERMANY, Witten INDIA, Chennai MEXICO, Monterrey RUSSIA, Moscow UK, Lancing USA, Tulsa Manufacturing plant & service center Service center October.2018 www.ruhrpumpen.com