Utica H 2 O. There Are Some Things You Can Always Depend On...

Similar documents
Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

Dunkirk H 2 O. Innovative. Efficient. Dependable. Dunkirk.

H 2 HYDRONIC BUFFER TANKS INSTALLATION, OPERATION & MAINTENANCE MANUAL

H 2. Hydronic Buffer Tanks INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS

INSTALLATION AND OPERATING INSTRUCTIONS

Advanced Heating & Hot Water Systems. Stainless Steel Indirect & Storage Tanks

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

INDIRECT FIRED WATER HEATERS

Heat Pumps COMFORT NEED IT. When You

/99 USA. Installation Manual SU Save These Instructions!

Indirect Fired Water Heater

Better Boilers.

Semi-Instantaneous Indirect Fired Water Heater

H 2 INDIRECT-FIRED WATER HEATERS FOR SINGLE WATER HEATER INSTALLATIONS INSTALLATION, OPERATION & MAINTENANCE MANUAL

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

H 2 O MODELS INSTALLATION, OPERATION & MAINTENANCE MANUAL O60D O80D O115D O60E O80E O60DE O80DE O115DE INDIRECT-FIRED WATER HEATERS

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

Warmth, efficiency, and total peace of mind.

INSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS

Stainless Steel Indirect Water Heaters

Versa- Hydro. up to 96% Efficient

ECO1ZN3P, ECO2ZN4P ECO

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job


A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps

Columbia Boiler Company

Stainless Steel Indirect Water Heaters

Packaged Semi-Instantaneous Steam Fired Water Heater

High Capacity Instantaneous Steam Fired Water Heater

Ve r s a - Hyd ro. 96% Efficient. The cost effec t i ve. ersa-hydro

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Caleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)

Indirect Fired Water Heaters

TANKLESS PRODUCT GUIDE

Project Name: Location: Engineer: Contractor: I. GENERAL

Easy Installation & Service

Owner s Manual Therma-Stor II Heat Recovery System

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

H 2. Hot Water Storage/ Booster Tanks INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS OST30 OST40 OST60 OST60L OST80 OST80C OST115 OST115C

Heat Pump Water Heater

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

Tepid Water Delivery System

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Installation & Operation Manual Models: TSU

Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119

Table of Contents. Installation, Operation, and Maintenance Manual V100 Series

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Technical Data Manual Model Nos. and pricing: see Price List

G124X - G234X - G334X Atmospheric Gas Boilers

Commercial Gas Water Heaters

Installation & Operation Manual Models: SIT030 - SIT119

MECHANICAL VENTING VERSATILITY

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Circulators high efficiency ECM Circulators

PART NO. COMBUSTION AIR TERMINATION CAP

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Light Duty Commercial Electric Water Heater

Residential & Commercial Water Heating

Suggested Specifications Prestige Excellence 110

Outdoor Reset IQ Option Card, p/n

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Outdoor Reset IQ Option Card, p/n

Indirect-Fired Water Heaters

Industry Best 10 Year Commercial Warranty

PART NO. THROUGH THE ROOF VENT CAP

Commercial Gas Water Heaters

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Installation & Operation Manual Models:

Technical Data Manual Model Nos. and pricing: see Price List

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Systems and Tanks. 40 H/V 60 H/V 80 V 115 V 139 V Gallon. Applications Sizing System Design

INSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS

Raypak Residential Products

GOLD Plus 30/40/60/80

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

Commercial Hot Water Maker

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Get The Edge Over The Competition with The Summit

ASME Packaged Electric Water Heater

Table of Contents. Installation, Operation, and Maintenance Manual ELBPxx

Marine Coolant Heater Catalog

ASME Packaged Indirect Fired Water Heater

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

OPERATION AND INSTALLATION UTILISATION ET INSTALLATION

Water Heaters. Solar Applications

INSTALLATION AND OPERATING INSTRUCTIONS

AM Rapid Recovery Water Heaters

Wood Boiler Plumbing Schematics

Mini-Combo id. Model MCH. Installation and Operation Instructions. Induced Draft Residential Gas-Fired Space/Water Heater

RESIDENTIAL WATER HEATERS SELECT Power Vent Gas Models (Single Pipe) * Height shown is to top of blower outlet ** All connections 3, increasers or red

Bid Date: Date: Project Name: Model Selected: i200x. Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Accessories: Contractor:

Applications and Piping Strategies for Condensing Boilers - Introduction

Transcription:

There Are Some Things You Can Always Depend On... Utica H 2 O - Stainless Steel Single & Dual Indirect Water Heaters - Storage Tanks - Hydronic Buffer Tanks

Introducing the NEW UTICA H2O Series... A complete line of Stainless Steel, Single and Dual Indirect Water Heaters, Storage Tanks, and Hydronic Buffer Tanks. Need An Easy Domestic Hot Water Solution With A Low Operating Cost and the Longevity Of Stainless Steel? Utica H2O Stainless Steel Single Indirect Water Heaters Need A Hot Water Solution To Balance Input and Storage While Reducing Short Cycling? Utica H2O Stainless Steel Storage Tanks Need A Hot Water Solution For Use With Chillers, Heat Pumps, and Low Mass Boilers? Utica H2O Stainless Steel Single & Dual Solar Water Heaters (Electric Back-Up can heat the tank if solar heat is unavailable) standard features Capacities (Gallons) Si Need A Hot Water Solution For Solar Applications Or Small Zones? ng Sta W le inle at C ss er oi S H l In te ea d el te ir Utica H2O Stainless Steel Hydronic Buffer Tanks 30, 40, 40L, 50, 60, 60L, 80 & 115 316L Stainless Steel Construction Top Connections (For Easy, Neat, Clean Installation) Stainless Steel Dip Tube Thermoplastic Jacket (Won t dent, scratch or corrode) Low Pressure Drop (Ideal For Low Mass Boilers) T & P Valve, Stainless Aquastat Well & Drain Valve (Factory installed-taped and doped). 2.25 EPS Insulation (Provides Less Than.5 F Per Hour Standby Loss) Large Diameter, Smooth Heat Exchangers - Prevent Buildup (Stainless Steel s Are 25 to 30 Long and 1-1/8 in Diameter) Honeywell L4080B (Shipped Loose) Made in the USA warranty Limited Lifetime Warranty (Residential), 5 Yr. (Commercial) Limited Lifetime Warranty OPTIONS Low Profile 40L & 60L Capacities High Output 80 & 115 Capacities Electric Back-Up Commercial Connections (For increased DHW flow) * 60, 80 & 115 Capacities 80 & 115 Capacities ( Dom., Blr.)

S s Bu tain ffe les rt ss an tee ks l S St tai or nle ag ss e St Ta ee nk l 40, 60, 80 & 115 D Sta u W al inle at C ss er o S H il S te ea o el te la r r t er re s c 30, 40, 60, 60L, 80 & 115 60, 80 & 115 * 60L Capacities 60, 80 & 115 Capacities 80 & 115 Capacities ( ) (,, 2 ) All Capacities 40, 60, 80 & 115 Capacities

Utica H 2 O Stainless Steel Single Indirect Water Heaters Dimensions/Weights Storage Capacity (Gals.) Heating Surface Sq. Ft. Piping Connections NPT Domestic Water In/Out Boiler Water In/Out H2OI30UB 30 7.0 3/4 1 HOT OUTLET DOM. COLD INLET 3/4" NPT RECIRC. PORT 1 1/2" NPT HOT OUTLET 1 1/4" NPT BOILER SUPPLY 1 1/2" NPT DOM. COLD INLET 9.5 Dimensions & Weights s Height Dia. Shp. Wgt. (Lbs.) H2OI30UB 32 22.5 85 H2OI40UB 42 22.5 100 H2OI40LUB 34 26.0 100 H2OI50UB 52 22.5 110 H2OI60UB 60 22.5 125 H2OI60LUB 44 26.5 120 H2OI80UB 54 26.5 140 H2OI115UB 72 26.5 175 H2OI80CUB 54 26.5 120 H2OI115CUB 72 26.5 175 H2OI80HOUB 54 26.5 155 H2OI115HOUB 72 26.5 190 H2OI80HOCUB 54 26.5 155 H2OI115HOCUB 72 26.5 190 AQUASTAT WELL DRAIN STANDARD UNIT AQUASTAT WELL DRAIN COMMERCIAL UNIT BOILER RETURN BOILER SUPPLY 1 1/4" NPT BOILER RETURN H2OI40UB 40 7.5 3/4 1 H2OI40LUB 42 7.1 3/4 1 H2OI50UB 50 3/4 1 H2OI60UB 60 8.4 3/4 1 H2OI60LUB 60 7.5 3/4 1 H2OI80UB 80 1 1 H2OI115UB 115 8.9 1 1 H2OI80CUB 80 H2OI115CUB 115 8.9 H2OI80HOUB 80 13.5 1 1 H2OI115HOUB 115 14.4 1 1 H2OI80HOCUB 80 13.5 H2OI115HOCUB 115 14.4 Note: Max. Working pressure 150 psi for all capacities. General Information (See Installation, Operation and Maintenance Manual for complete instructions) Max. First Hour Rating Gal./Hr @ Continuous Rating Gal./Hr. @ Boiler Output Required Min. Boiler Water Flow Through Pressure Drop Through 140 F 115 F 140 F 115 F (BTU/Hr.) (Gal./Min.) (Ft. Water) H2OI30UB 182 242 155 215 116,200 10.0 2.7 H2OI40UB 202 266 166 230 124,500 10.0 2.9 H2OI40LUB 193 251 157 215 117,900 10.0 2.8 H2OI50UB 222 290 177 245 132,800 10.0 3.1 H2OI60UB 240 311 186 257 139,400 10.0 3.2 H2OI60LUB 220 284 166 230 124,500 10.0 2.9 H2OI80UB 257 328 185 256 138,600 12.0 3.7 H2OI115UB 309 388 206 285 154,200 12.0 4.0 H2OI80CUB 257 328 185 256 138,600 12.0 3.7 H2OI115CUB 309 388 206 285 154,200 12.0 4.0 H2OI80HOUB 386 507 314 435 235,670 15.0 9.0 H2OI115HOUB 439 568 336 465 251,780 15.0 9.5 H2OI80HOCUB 386 507 314 435 235,670 15.0 9.0 H2OI115HOCUB 439 568 336 465 251,780 15.0 9.5 Note: All ratings are based on 200 F boiler water supply and 50 F cold water inlet. See installation manual for ratings at different temperatures and flow rates. Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. (L) Low profile models for applications with low clearances. (C) Commercial models with larger tappings for higher flow rates. (HO) High Output models available to meet greater demand. H2O I=Indirect Capacity: 30=30 Gals. 40=40 Gals. 50=50 Gals. L=Lowboy C=Commercial HO=High Output HOC=High Output 60=60 Gals. Commercial 80=80 Gals. 115=115 Gals. Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No. 110-94 L UB UB=Utica Boiler

Utica H 2 O Stainless Steel Storage Tanks Piping Connections NPT Dimensions/Weights Storage Capacity (Gals.) Cold/Hot Supply/Return Heat Source Pressure SUPPLY TO HEAT SOURCE RETURN FROM HEAT SOURCE H2OST30UB 30 1 1 H2OST40UB 40 1 1 H2OST60UB 60 1 1 H2OST60LUB 60 1 1 H2OST80UB 80 1 1 COLD WATER INLET HOT OUTLET H2OST115UB 115 1 1 TOP CONNECTIONS ALL 1" NPT H2OST80CUB 80 1 H2OST115CUB 115 1 Note: Max. Working pressure 150 psi for all capacities. 3/4" NPT RECIRC. PORT 1 1/2" NPT HOT OUTLET AQUASTAT WELL DRAIN STANDARD UNITS General Information (See Installation, Operation and Maintenance Manual for complete instructions) Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. (L) Low profile models for applications with low clearances. (C) Commercial models available for applications with larger connections. H2O ST=Storage ST Tank Capacity: L=Lowboy 30=30 Gals. C=Commercial 40=40 Gals. 60=60 Gals. 80=80 Gals. 115=115 Gals. L UB UB=Utica Boiler 1" NPT SUPPLY TO HEAT SOURCE 1" NPT RETURN FROM HEAT SOURCE Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No. 110-94 1 1/2" NPT COLD INLET AQUASTAT WELL Schematic Diagram (Typical Installation) 9.5 DRAIN COMMERCIAL UNITS s Dimensions & Weights Height Dia. Shp. Wgt. (Lbs.) H2OST30UB 34.0 23.5 75 H2OST40UB 44.0 23.5 90 H2OST60UB 62.0 23.5 115 H2OST60LUB 46.0 23.5 110 H2OST80UB 56.0 2 140 H2OST115UB 74.0 2 175 H2OST80CUB 56.0 2 140 H2OST115CUB 74.0 2 175

Utica H 2 O Stainless Steel Buffer Tanks Dimensions/Weights Storage Capacity (Gals.) Piping Connections NPT H2OBT40114UB H2OBT40112UB 40 H2OBT402UB 2 H2OBT60114UB H2OBT60112UB 60 H2OBT602UB 2 H2OBT80112UB H2OBT80114UB 80 H2OBT802UB 2 H2OBT115114UB H2OBT115112UB 115 H2OBT1152UB 2 H2OBT40114WCUB H2OBT40112WCUB 40 H2OBT402WCUB 2 H2OBT60114WCUB H2OBT60112WCUB 60 H2OBT602WCUB 2 H2OBT80114WCUB H2OBT80112WCUB 80 H2OBT802WCUB 2 H2OBT115114WCUB H2OBT115112WCUB 115 H2OBT1152WCUB 2 Note: Max. Working pressure 60 psi for all capacities. H2O40BT114UB H2O40BT112UB H2O40BT2UB H2O60BT114UB H2O60BT112UB H2O60BT2UB H2O80BT114UB H2O80BT112UB H2O80BT2UB H2O115BT114UB H2O115BT112UB H2O115BT2UB Dimensions & Weights Height A B C 42.0 31 11 44.0 31.5 11.5 54.0 40.5 11.5 72.0 61.5 11.5 Shp. Wgt. (Lbs.) 87 (97 WC) 115 (125 WC) 125 (135 WC) 160 (170 WC) General Information (See Installation, Operation and Maintenance Manual for complete instructions) Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. (WC) With H2O BT=Buffer BT 40 Tank Capacity: 40=40 Gals. 60=60 Gals. 80=80 Gals. 115=115 Gals. 114 114= NPT WC=With 112= NPT 2=2 NPT WC UB UB=Utica Boiler Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No. 110-94

UTICA H 2 O Stainless steel Buffer tanks Reduces chiller or boiler short cycling (Short cycling results in reduced operating efficiency and shorter equipment life) Used in systems having several low BTU cooling or heating loads calling at different times Full size tappings on buffer tank for peak performance (,, and 2 ) Used in systems operating below the design load condition, which is most of the time. H 2 O hydraulically decoupled To/From Boiler/Chiller/Heat-Pump To/From System Buffer Tanks Buffer Tank Sizing - Calculating Capacity Utica H 2 O buffer tanks are a simple, cost effective way to improve overall system efficiency by reducing unnecessary equipment short cycling. The recommended capacity or volume of a buffer tank is based on four variables. 1) The duration of the heating or cooling source on time (minutes). The desired length of on time for each run cycle depends on the type of equipment used. Heat pump and chiller manufacturers typically recommend a minimum of 5 to 10 minutes on time, and boiler manufacturers may recommend a minimum of 10 minutes on time. Check with your equipment manufacturer. Generally, the longer the on time, the higher the overall operating efficiency. 2) The minimum rate of heat input (BTU/HR). This is based on the heat pump or chiller output, or the boiler output at the minimum firing rate if the boiler has a variable input system that ramps input down as the demand decreases. 3) The minimum system load (BTU/HR). This is the demand placed on the system with the smallest zone calling for heat. 4) The allowable tank temperature rise (deg. F). This varies depending on the type of heating or cooling system used, and on the design of the distribution system. Chillers may require a tight, (6 deg. F), differential to assure good dehumidification and prevent freezing, heat pumps may require a (10 deg. F) differential to maintain a high COP, and boilers with hydronic heating distribution systems may require a differential anywhere between 10 to 40 deg. F depending on the application. The following formula determines the tank volume: V = T X ( Q heat input - Q min. heat load) Tank temp. rise X 500 V = Buffer tank volume (gallons) Q heat source = heat source output (BTU/HR) Tank temp rise (deg. F) T = desired heat source on cycle (min.) Q min. heat load = heat output to minimum load Water to Water Heat Pump Example: Town and Country Mechanical wants a minimum heat pump on time of 10 minutes. The heat pump output is 46,500 BTU/HR. The smallest zone is a 7,000 BTU/HR bathroom. The allowable temperature differential is 90 to 100 deg. F for the radiant heat zones. V = 10 x (46,500-7,000) (100-90) x 500 = 79.0 Gallons minimum volume. Choose the H2O80BT buffer tank.

Utica H 2 O Stainless Steel Dual and Single Solar Water Heaters Dimensions/Weights TOP COIL SUPPLY COLD WATER IN BOTTOM SOLAR COIL RETURN Dimensions & Weights s Height SINGLE COIL Dia. Shp. Wgt. (Lbs.) H2OI60EUB 62.0 23.5 135 H2OI80EUB 56.0 2 145 H2OI115EUB 74.0 2 180 DUAL COIL TOP COIL RETURN HOT WATER OUT BOTTOM SOLAR COIL SUPPLY TOP COIL 3/8" ID THERMAL WELL 1/2" NPT RECIRC. RETURN PORT TOP HEATING COIL FOR BACKUP BOTTOM COIL 3/8" ID THERMAL WELL BOTTOM HEATING COIL FOR SOLAR DUAL COIL UNITS H2OI60DUB 62.0 23.5 165 H2OI80DUB 56.0 2 175 H2OI115DUB 74.0 2 205 H2OI60DEUB 62.0 23.5 175 H2OI80DEUB 56.0 2 185 H2OI115DEUB 74.0 2 215 1.5 4" X 10" ELECTRICAL BOX 3/8" ID THERMAL WELL DRAIN VALVE ELECTRIC BACKUP UNITS Storage Capacity (Gals.) Top Heating Surface Sq. Ft. SINGLE COIL Bottom Heating Surface Sq. Ft. Piping Connections NPT H2OI60EUB 60 8.3 1 H2OI80EUB 80 1 H2OI115EUB 115 8.9 1 DUAL COIL H2OI60DUB 60 7.4 8.3 1 H2OI80DUB 80 7.4 1 H2OI115DUB 115 7.4 8.9 1 H2OI60DEUB 60 7.4 8.3 1 H2OI80DEUB 80 7.4 1 H2OI115DEUB 115 7.4 8.9 1 Note: Max. Working pressure 150 psi for all capacities. General Information (See Installation, Operation and Maintenance Manual for complete instructions) Max. First Hour Rating Gal./Hr. @ Continuous Rating Gal./Hr. @ Max. Rec. Top Max. Rec. Bottom Min. Boiler Water Flow Through Pressure Drop Through 140 F 115 F 140 F 115 F (Gal./Hr.) (Gal./Hr.) (Gal./Min.) (Ft. Water) SINGLE COIL H2OI60EUB 45.9 52.0 15.9 22.0 214 10.0 3.5 H2OI80EUB 55.9 62.0 15.9 22.0 214 10.0 3.6 H2OI115EUB 73.9 80.0 15.9 22.0 214 10.0 3.9 DUAL COIL H2OI60DUB 45.9 52.0 15.9 22.0 185 214 10.0 3.5 H2OI80DUB 55.9 62.0 15.9 22.0 180 214 10.0 3.6 H2OI115DUB 73.9 80.0 15.9 22.0 190 214 10.0 3.9 H2OI60DEUB 45.9 52.0 15.9 22.0 185 214 10.0 3.5 H2OI80DEUB 55.9 62.0 15.9 22.0 180 214 10.0 3.6 H2OI115DEUB 73.9 80.0 15.9 22.0 190 214 10.0 3.9 Note: All ratings are based on 180 F boiler water supply and 50 F cold water inlet. For Dual units, continuous ratings shown are for the lower coil only. Specifications subject to change without notice. Equipment Options Certification/ Decoding Factory installed brass drain and relief valves, welded stainless steel cold water dip tube factory installed and pressure tested, Honeywell L4080B aquastat for field installation. Removable thermal well to accept a solar control thermostat or thermistor. Dual coil units equipped with two aquastat wells which control each coil independently and built-in recirculation tapping. Units with Electric Back-Up are provided with 4 x 10 electrical box with pre-wired heating element, thermostat, and hi-limit. All electric back-up units provided with 240 volt AC, 3500 watt element. (E) Electric Back-Up models for supplemental heating. H2O 60 D E UB I=Indirect Capacity: D=Dual E=Electrical UB=Utica Boiler 60=60 Gals. Back up 80=80 Gals. (3500 Watts) 115=115 Gals. Conforms to UL STD 174 Certified to CAN/CSA STD C22.2 No. 110-94 PN 240009329 Rev. 11/13 Contractor Assistance: 800.325.5479 P.O. Box 4729 Utica, New York 13504 tel: 315.797.1310 fax: 315.797.3762 www.uticaboilers.com