T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Similar documents
The T6140A,B Remote Bulb Temperature Controller

T7079A,B Solid State Remote Temperature Controllers

T4098A,B Deluxe Electric Heat Thermostats

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

T4398A,B High Performance Electric Heat Thermostats

C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

Commercial/Industrial Combustion Control Level Three Announcement

C554A Cadmium Sulfide Flame Detector

T4398A,B Precision Electric Heating Thermostat

L8151A Triple Aquastat Relay

T834C Heating-Cooling Thermostat

CR7075 Two-Stage Lighting Controller

C6097A,B Pressure Switches

TC-5231 Series, TC-5232, & TC-5241 Series

IS Series Pressure Sensing Switches

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

T874 Multistage Thermostat and Q674 Subbase

L4188A,B; L4189A,B; L6188A-C; L6189A-C Aquastat Controllers

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

T6984F,G Electronic Floating Control Thermostats

F150E Media Air Cleaner

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

F25F Media Air Cleaner

HE120, HE160 Humidifier Installation Kit

F200E Charged-Media Air Cleaner

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

TP970 Series CONVERTASTAT Kits

T7984 A,B,C Electronic Modulating Control Thermostats

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

Powers TM Controls ET 134 Line Voltage Room Thermostats

C7232A,B Sensor and Controller

M6063A Compact Rotary Mixing Valve Actuator

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

H1008A,D Automatic Humidity Controls

Tubular Industrial Process

RA889A Switching Relay

HE360 Humidifier Installation Kit

Home and Building Control Home and Building Control Helping You Control Your World

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

Powers Controls ET 134 Low Temperature Detection Thermostat

C7004B Flame Rod Holder

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller

temperature Controllers

T6984 A,D,E Electronic Floating Control Thermostats

P7810A-D Pressuretrol Controller

W43A Humidistat. Features and Benefits

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

Q382A,B Pilot Burners

T8411R Electronic Heat Pump Thermostat

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

A19, A28 Series Thermostats for Agricultural Buildings

HE365A,B Powered Flow-Through Humidifier

HE220, HE260 Humidifier Installation Kit

Installation Instructions

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

CT500 Electronic Thermostat

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell

Powers Controls Low Temperature Detection Thermostat

CT1500, CT1501, CT1502, CT1503

XT Series Thermostats

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

TEMPERATURE & PRESSURE CONTROLS

Tubular Industrial Process

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions.

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

! WARNING. Before using product, read and understand instructions.

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

UV100E Ultraviolet Air Treatment System

A99B Series Temperature Sensors

T8011R Programmable Heat Pump Thermostat

TK-1801, TK-1811 TK-1801, TKR-1811

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

L404A-D, F; L604A,L Pressuretrol Controllers

TK-2001, TK-2012, TK-2201, TK-3001, TK-3201, TK-4001, TK-4012, TK-4212 TK

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostat KPU. Data sheet

TK-1001, 1101, 1201, 1301, 1601

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

BC BRONCOS AIR CONDITIONING UNIT

Installation Instructions

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

DS 2001 REVISED Humidifier Assembly and Instruction Manual

7800 SERIES EC7823/RM7823 Relay Module

RA890G Protectorelay Primary Control

T8034C Heating/Cooling Thermostats

A11 Series Low Temperature Cutout Controls

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers

Powers TM Controls TH 188 Unit Mounted Thermostat

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

Installation Instructions

HX Field Replacement Kit

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Transcription:

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers FEATURES PRODUCT DATA Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination. Universal mounting bracket is available for easy replacement of other controllers. Models are available with various control ranges. Control setpoint is dial-knob adjustable. Models are available with fixed or adjustable temperature differentials. Capillary lengths are 5, 8, or 20 ft (1.5, 2.4, 6.1m) depending on model. Reliable snap-acting spst or spdt switch. GENERAL The T4031A,B,P and T6031A,B are temperature controllers used in a variety of cooling applications where remote mounting of the sensing element in the controlled medium is required. Ambient temperature compensated. Insert supplied with TRADELINE models replaces setpoint knob to discourage tampering. Contents General... 1 Features... 1 Specifications... 2 Ordering Information... 2 Installation... 3 Operation and Checkout... 5 Copyright 1995 Honeywell Inc. All Rights Reserved 60-2177-3

SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the specifications listed. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. TRADELINE Models TRADELINE models are selected and packaged to provide ease of stocking, ease of handling, and maximum replacement value. TRADELINE model specifications are the same as those of standard models except as noted below. TRADELINE Model Available: T6031A Refrigeration Temperature Controller-spdt switch, adjustable temperature differential, tamper-resistant insert. Capillary Lengths and Temperature Ranges: a Dial scale markings in degrees Fahrenheit Capillary Length: 8 ft (2.4m) Additional Features: TRADELINE pack with cross reference label and special instructions Standard Models T4031A Refrigeration Temperature Controller-spst switch makes on temperature rise; fixed differential T4031B Refrigeration Temperature Controller same as T4031A but less case T4031P Refrigeration Temperature Controller same as T4031A but uses screw, not knob, to adjust setpoint T6031A Refrigeration Temperature Controller-spdt switch, fixed or adjustable temperature differential T6031B Refrigeration Temperature Controller same as T6031A but less case Switch Action: T4031A,B,P spst switch makes R to W on temperature rise T6031A,B spdt switch makes R to W on temperature rise, R to B on temperature fall Copper Capillary Tube Length Setting Range a Differential Model ft m F C F C T4031A,B 5 1.5-30 to 50-34 to 10 Fixed at 3.5 Fixed at 1.6 20 6.1 T4031P 8 2.4-30 to +90-34 to +32 3.5 to 16 1.6 to 9 T6031A,B 5 1.5-15 to +90-9 to +32 Fixed at 3.5 or Adjust. from 3.5 to 12 Fixed at 1.6 or Adjust. from 1.6 to 7 20 6.1 5 1.5-30 to +50-34 to +10 20 6.1 8 2.4-30 to +90-34 to +32 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE wholesaler or your distributor, refer to the TRADELINE catalog or price sheets for complete ordering number, or specify: 1. Order number. 4. Length of copper capillary tube. 2. Setting range. 5. Accessories, if desired. 3. Fixed or adjustable differential (T6031). If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Home and Building Control Sales office (check white pages of your phone directory). 2. Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. 2

Electrical Ratings: Full Load Amp Locked Rotor Amp Normally Closed a Makes on temperature rise. Pilot Duty: 125 VA Dimensions: See Fig. 1 15/16 (24) 17/32 (13) 4-3/16 (107) 29/32 (23) 3/8 (9) 7/32 (6) 2 (51) 1-3/16 (30) 120 Vac 240 Vac Normally Open a Normally Closed Normally Open a 8 16 5.1 8 48 80 30.6 40 KNOCKOUT FOR 1/2 IN. (13 MM) CONDUIT (2) 7/32 (6) DIA. (3) 3/8 (10) DIA. (3) 5-5/8 (136) 2-1/4 (57) 2-1/8 (54) M4496 Fig. 1. Dimensions of T4031, T6031 in in. (mm). Underwriters Laboratories Inc.: Listed Maximum Ambient Operating Temperature: 125 F (52 C) Accessories: 112622AA Immersion Well short-necked, 1/2 in. NPT, copper 7617ABY Compression Fitting 50 psi water, 15 psi air 107324A Bulb Holder for duct installation 105900 T-strap for strapping bulb to pipe 7617ABZ Bag Assembly for mounting controller to fan coil units 801534 Calibration Wrench 7640HY Standoff Bracket Bag Assembly to mount controller to an insulated duct 130883 Universal Mounting Bracket 194899 Tamper-resisting Insert Button Celsius Scaleplates: 194486 D: -15 C to +35 C replaces (0 F to 100 F) scaleplate 194486H: 15 C to 75 C replaces (55 F to 175 F) 194486F: 75 C to 125 C replaces (160 F to 260 F) INSTALLATION When Installing this Product 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. CAUTION Disconnect power supply before installation to prevent electrical shock and equipment damage. Do not damage or change shape of capsule. Deformed capsule will cause calibration offset. Mounting Install controller in any convenient location. Make sure that the sensing bulb reaches the system to be controlled. The ambient temperature must not exceed 125 F (52 C) in the area where the controller is installed. Install the sensing element where it can sense the average temperature. Avoid sharp bends or kinks in the capillary tubing that can affect the accuracy of the controller. Carefully coil the excess capillary tubing and leave it directly beneath the controller. The 130883 Mounting Plate furnished with TRADELINE models allows the control to be mounted in existing mounting holes. Duct Installation Position the sensing bulb in the duct to sense the average air temperature. Avoid mounting the bulb close to hot pipes, cooling coils, etc. The 107324A Bulb Holder is available for suspending the bulb in a duct. See Fig. 2. 3

SENSING BULB THREAD M8970 COMPOSITION PACKING (SLIT) Fig. 2. 107324A bulb holder. To install duct: 1. Make a hole in duct wall to admit sensing bulb into holder. 2. Using holder as template, mark and drill mounting holes. 3. Break off bulb holder to required length. (Be sure holder is long enough to hold sensing bulb away from duct wall and in freely circulating air.) 4. Place capillary tubing in bulb holder channel, with bulb at inner end of holder. Pinch together top edges of channel segments. 5. Insert assembled bulb and holder into duct, and fasten to duct wall with screws supplied. PACKING NUT SLOTTED WASHERS ASSEMBLED IN PAIRS: BOILER PLUG Fig. 3. Compression fitting installation. BULB RETAINING CLAMP M4492 IMMERSION WELL Tank Installation The sensing bulb can be inserted directly into a tank using a compression fitting; or the bulb can be inserted into an immersion well (order separately), which is screwed into a tank or boiler. CAPILLARY WELL SPUD M4493 Select a location where liquid of average temperature can circulate freely around the sensing bulb. Using Compression Fitting (Fig. 3) 1. Drain system. Screw boiler plug into properly sized and threaded boiler or pipe tapping. 2. Place packing nut on capillary tubing. 3. Slide sensing bulb completely through boiler plug. 4. Place composition disc and the four slotted brass washers on capillary tubing. 5. Slide assembly into boiler plug and tighten packing nut. 6. Refill system and check for leaks. Neatly coil excess capillary tubing. Using Immersion Well (Fig. 4) 1. Drain system. Screw the well into threaded fitting. 2. Refill system and check for leaks. 3. Insert sensing bulb into well until it bottoms. 4. Fit bulb retaining clamp over immersion well flange and capillary tubing, and tighten screw. Fig. 4. Immersion well installation. Cold Room Installation Locate the bulb in freely circulating air in the controlled area or on the suction side of a refrigerant line, and secure the bulb in position. Wiring (Fig. 5) All wiring must comply with local electrical codes and ordinances. Two knockouts are provided, one at the top and one at the bottom of the case for 1/2 in. conduit. Follow the wiring instructions furnished with the heating or cooling system. For replacement, make sure the new control is wired into the system to operate the same as the old control. 2 TEMPERATURE FALL B-R MAKES TEMPERATURE RISE R-W MAKES 1 B W 1 2 B TERMINAL ON T6031 CONTROLLERS ONLY. AT SETPOINT MINUS DIFFERENTIAL SETTING. R M4494 Fig. 5. Wiring terminals on T4031 and T6031 temperature controllers. 4

OPERATION AND CHECKOUT When the temperature at the sensing bulb rises above the controller setpoint, a circuit is made between the R-W terminals. During a temperature fall, the R-W circuit breaks at the setpoint temperature minus the switch differential. Controllers with a B terminal break the B-R terminal circuit on a temperature rise to the setpoint. B-R makes again when R-W breaks on a temperature drop. See Fig. 6. For example, if a controller with a 3 F (1.7 C) differential is set at 39 F (3.9 C), R-W makes when the bulb temperature rises to 39 F. Then during a temperature fall, R-W breaks when the temperature drops to 35 F (1.7 C) (39 F minus the 3 F differential [3.9 C minus the 1.7 C differential]). Calibration All controllers are carefully tested and calibrated at the factory under controlled conditions. If the controller is not operating at a temperature corresponding to the scale and differential setting, verify that the bulb senses the average temperature of the medium. If the temperature of the controlled medium is changing rapidly, the differential will appear wider than its setting. TERMINAL SCREWS (3) On models with a B terminal, B-R makes when R-W breaks. Then the temperature has to climb past the control differential to the set point of 39 F (3.9 C) before the B-R circuit breaks and the R-W circuit makes. B R-W B R-W T6031 DIFFERENTIAL ADJUSTMENT M4497 39 F (4 C) B-R MAKES R-W BREAKS B-R W B-R W SWITCH ACTION ON TEMPERATURTE RISE CONTROL SETPOINT 3.5 F (1.6 C) DIFFERENTIAL 39 F (4 C) 35.5 F (2 C) B-R MAKES R-W BREAKS SWITCH ACTION ON TEMPERATURE FALL M4495 Fig. 6. Operation of switch on temperature rise and fall. SETTING Set the controller to the system manufacturer s recommended settings, if available. Temperature Setpoint Knob Turn the knob on the front of the case until the pointer indicates the temperature to be maintained in the controlled medium. Screw Insert a flatheaded screwdriver into the slot on the shaft, which is located in the center of the scaleplate. Turn the screwdriver clockwise to increase the temperature control point. Turn the screwdriver counterclockwise to decrease the temperature control point. Adjustable Differential With the cover off, turn the differential adjustment wheel (marked 3-6-9-12 F) until the desired differential is aligned with the notch in the frame. See Fig. 7. Fig. 7. Internal view showing differential adjustment wheel (applicable models). For calibration, take an accurate temperature reading of the controlled medium. Place an accurate thermometer near the bulb of the controller, or refer to a thermometer installed as part of the system. If the bulb of the controller is installed in an inaccessible area, or if the controlled medium is unstable, remove the bulb and place in a controlled bath for accurate calibration. These controllers are calibrated so the dial setting is the point at which the R-W switch contacts make (B-R contacts break) on a temperature rise. Measure the temperature at the bulb. Rotate the dial counterclockwise from the top of the scale, simulating a temperature rise, until the R-W switch contacts make. Note the dial reading. If it differs from the setpoint, calibrate the dial as follows: 1. Determine the number of degrees difference between the set point and the point at which the contacts make. 2. Remove the dial knob and slip the fingers of the calibration wrench into the slots of the dial. Rotate the dial until the fingers of the wrench drop into the slots of the calibration nut under the dial. Note the dial indication at this point. Turn the dial and the calibration nut up or down scale the number of degrees that the set point differs from the point at which the contacts make (determined in step 1). For example, move the dial from 45 to 65 degrees for a 20 degree change in calibration. 3. Check the calibration adjustment by moving the dial up and down the scale while watching the contacts make and break. If dial is still out of calibration, repeat calibration procedure. 4. To install tamper-resisting insert on TRADELINE model, remove screw from adjustment knob, remove knob, and install insert. Fixed differential models are 3.5 F at midscale. 5

6

7

Home and Building Control Honeywell Inc. 1985 Douglas Drive North Golden Valley, MN 55422 J.H. Rev. 5-95 Printed in U.S.A. Home and Building Control Honeywell Limited-Honeywell Limitée 740 Ellesmere Road Scarborough, Ontario M1P 2V9 8 Helping You Control Your World QUALITY IS KEY www.honeywell.com/building/components