eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Similar documents
TopMaster Air Handling unit. Technical data

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

TopMaster Air Handling Unit

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

recooler HP EQKR HEAT PUMP

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

VERSO Air Handling Units

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

KOMFORT EC DB Suspended heat recovery air handling units

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Heat recovery unit RDKS

VERSO Air Handling Units

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

iq Star LYRA II chilled beam cassette

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

VEX100 series Air handling units with cross-flow heat exchanger

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Lo-Carbon Sentinel Kinetic Horizontal

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

The new Xcell EC High Efficiency Range Fresh air pure and simple

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

Small Room Heat Recovery Ventilation

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

TopMaster Air Handling unit. Installation instructions

Air Handling Units. Geniox. Quick guide

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

EC L2. and humidity sensors. All units are supplied tested and ready to install.

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Sentinel Demand Energy Recovery Ventilation

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

TECHNICAL SPECIFICATION

CHILLED BEAM CASSETTE IQ STAR LYRA

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

eco PREMIUM ENERGY RECOVERY UNIT» INSTALLATION AND MAINTENANCE MANUAL

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Topvex SR03, SR04, SR06 Compact Air Handling Unit

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

The Sentinel Kinetic Horizontal Range

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

HOTEL CHILLED BEAM IQ STAR SILENCIA

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

iq Star LYRA II chilled beam cassette

TSEK VHR EC HEAT RECOVERY UNITS

Heat and energy recovery ventilators

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

MRXBOXAB-ECO3 MRXBOX-ECO3

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

MRXBOXAB-ECO2 MRXBOX-ECO2

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Topvex SF02-SF12 Air Handling Unit

UNITES TERMINALES ET MINI CTA FIDJI

COMPACT Air & Heat. Contents

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

AIR HANDLING UNITS MANDÍK

eco TOP INSTALLATION AND MAINTENANCE MANUAL

GLOBAL RX. Ventilation unit with rotary heat exchanger

ROOFMASTER STEF-HT ROOF FAN

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

VORT NRG RANGE COMMERCIAL VENTILATION NEW

Series VENTS VUT R WH ЕС

Air Handling Units. direct drive - belt drive - custom built

CONTENT: VEX308 Decentralised ventilation VEX308

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

GOLDTM. Air Handling Units with Built-in Control Equipment that offer Economical Operation.

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Transcription:

Air Comfort Air Treatment Energy Recovery eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

eco PREMIUM - Technical Instruction REDA 2 Contents Description Applications... 3 Quality & environment... 3 Product data - Main Code... 3 Description of the unit - Design Casing...4 Filter...4 Plate Heat exchanger...4 Fan...4 Unit Versions Water Post Heater (Enhanced & Elite)...4 Electrical Post Heater (Enhanced & Elite)...4 Electric Pre Heater (Elite)...4 Technical Data Size 1... 5 Size 2... 6 Size 3...7 Size 4... 8 Size 5... 9 Size 6... 1 Accessories REDZ-14 Duct mounted Cooling coil...12 REDZ-8 Weather cover Roof...12 REDZ-81 Spare filters...12 REDZ-82 Duct mounted Pre Heater...12 REDZ-84 Drain Trap...13 REDZ-85 Acoustic Silencer...13 REDZ-86 Standard Silencer...13 REDZ-87 Shut off damper with actuator...14 REDZ-88 Mounting feet...14 REDZ-89 Weather Cowl kit...14 Controls General...15 Standard Control Functions...15 Accessories/Open options... 16 Order codes Product code...17 Accesories...17 Dimensions and weight Size 1-6... 11 Minimum Maintenance space... 11 Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 3 Description Applications eco PREMIUM is a compact unit in six sizes that require minimal space and cover a flow range up to,9 m 3 /s. Compact dimensions and low noise data provides great flexibility in the placement of the unit. The unit is supplied with direct drive on both supply and exhaust fans, compact supply and extract air filters and a counterflow heat exchanger. All duct connections are on side of the unit. High efficiency counterflow heat exchanger with Thermo Ice defrosting and % bypass. Built in post-heater (water or electrical) and or preheater as option in colder climate Casing leakage L2 as standard The CURO control Plug & play system is integrated with the unit and is ready for use with a large number of functions. Communication Modbus RS 485 is standard (TCP/IP as option) As an option On Demand ventilation is available via PIR (occupancy) or CO 2 sensors Acoustic version is available when there is a high demand on low sound emission Optional accessories available for installation outside. Quality & Environment All units and components from Fläkt Woods are designed, tested and manufactured in accordance with applicable standards including the quality assurance system ISO 91, the environmental management system ISO 141 and the Energy Directive 29/125/EC (LOT 6) for RVU and NRVU. Product data - Main CODE Size REDA-a-b-cc-d-e-ff The eco PREMIUM unit is available in 6 optimized sizes. Air flow, m 3 /h 2 3 4 5 2 3 eco PREMIUM 2 eco PREMIUM 1 eco PREMIUM 4 eco PREMIUM 3 eco PREMIUM 6 eco PREMIUM 5 3 4 5 2 3 5 Air flow, l/s * Essential version with G4 filters at Pa external pressure. Inspection side and Acoustic Casing REDA-a-b-cc-d-e-ff All casing sizes are available with left and right side inspection side. Size 1-4 are available in acoustic version with left or right inspection side. The Acoustic version is built to minimize the sound emission from the unit (lower break out noise level). Unit versions REDA-a-b-cc-d-e-ff eco PREMIUM range is available in 3 versions: Essential: Standard unit with plate heat exchanger and filters fitted Enhanced: Essential version with Post heater fitted (water or eletric) Elite: Enhanced version with Pre heater (electric), duct to install in ductwork Filters REDA-a-b-cc-d-e-ff Filters are included to provide protection to other components (i.e., exchanger/fans) and are mounted within runners for easy fitting/removal. ECO PREMIUM unit can be equipped with the following filter options. G4 class to the fresh air intake and return air F7 class to the fresh air intake and M5 on the return air Fan speed control REDA-a-b-cc-d-e-ff Different fan speed control is available to individually adjust the airflow for supply and exhaust side. The following variants can be selected and will automatic be handled by the CURO Control. VAV: Variable Air Volume. Fan speeds are set individually between 3-% COP. Constant Pressure CAV. Constant Air Volume VAV+CO 2. Fan speeds are set individually, overrides by the demand ventilation (CO 2 ) when the set PPM value is exceeded. Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 4 Description Essential version unit design Casing The unit is made of self-supporting double skin galvanized sheet steel, insulated with 25 mm mineral wool (35 kg/m 3 ). All panels have plastic handles integrated in the outer panel. The filter panel (service side) has screws with plastic head for easy access (by hand) where other panels has fasteners that requires screwdriver. The unit is supplied on a stable base which can be fitted with feet. Corrosivity class C3 (BSK 94/99 and ISO 12944-2) Leakage class L2 (EN 1886)) Casing components Filter Filter for supply and extract air are made of compact fiberglass optimized for low pressure drop. G4 or F7 class is available on the supply air and G4 or M5 on the extract air. The filters are pressed against the runners inside the casing for tightness and easy fitting/removal. Plate heat exchanger AND SYSTEM THERMO ICE In apartment buildings and hotels, it is important with energy recovery systems which is easy care and keeps the energy costs low, and in some cases avoids cross-contamination. eco PRE- MIUM uses a Eurovent certified counterflow heat echanger and provides over 85% thermal efficiency according EN 38. During normal ventilation there is no need for defrosting but when the relative humidity of the extract air is high and the outdoor temperature lower than 5 C there may be a risk of frosting. eco PREMIUM uses a defrost system Thermo Ice* that has undergone complete laboratory tests and is activated only when the efficiency of the core has been reduced to a certain level due to the frost. The heat exchanger is divided in sections for easy removing and cleaning. UNIT VERSION: ENHANCED AND ELITE Water post heater (Enhanced & Elite) The air heater for water heating consists of copper pipe and aluminum fins. Pipe connection Ø15 mm. Contact sensors for frost protection are included in the control equipment. Recommended for outdoor temperatures down to -5 C. Max. operating pressure 1.6 MPa Electric post heater (Enhanced & Elite) The electric heater has built-in control equipment for power control. The element is made of stainless steel. The heater has two thermal overload protection devices, one with an automatic reset and one with a manual reset accessible from the outside of the unit. Recommended for outdoor temperatures down to 5 C. Electric pre heater (Elite) The electric pre heater is recommended when outdoor temperatures is between 5 C to 15 C, when you don t want to have supply fans stopped due to defrosting. The pre heater is a stand alone device without connection to the Curo control system. The heater has built-in control equipment. The element is made of stainless steel. The heater has two thermal overload protection devices, one with an automatic reset and one with a manual reset accessible from the outside of the cabinet. *Thermo Ice is a demand controlled defrosting function that ensures minimal energy loss and is only activated when there is frost built up inside the core. Fan eco PREMIUM gives you top performance and overall eco nomy combined with low noise levels. The high efficiency fans are powered by energy saving EC motors. The fan speed can be adjusted independently by the unit s CURO control system and have a built in alarm. Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 5 Technical data - size 1 Supply air fan Extract air fan 7 5 9 7 5 9 6 6 5 5 4 4 3 3 75 2 7 8 2 5 6 4 45 6 L wa, db 5 15 2 25 L wa, db 5 15 2 25 SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) System overview The diagrams show the available external pressure for the duct system. The weighted sound power noise levels given in db(a) apply to ducts on the supply fan s outlet side (diagram 1) and extract fans inlet side (diagram 2). The SFP v values for each fan are calculated according to clean filters. SFPv is calculated for the complete unit and includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater. electrical data External fuse: Recommended 1 A. The mains supply cable must be fitted with an external safety switch, which can cut the current to the entire unit. Ambient temperature during operation 2 - +4 C Temperature efficiency η, % 9 8 η Efficiency % dry 2) η Efficiency % wet 3) 7 5 15 2) According to EN38. 3) 5 C/RH 9% Outdoor and +22 C/RH 5% Extract. Filter Supply air: x 37 x 48 mm, G4 alt F7 Extract air: x 37 x 48 mm, G4 alt M5 2 25 Unit fan Motors Post Rated Rated Electrical Version Power, 2 fans Heater Power Current Supply kw kw kw A V/Ph/Hz Essential Enhanced HW.338.358 2.8 23/1/5 Elite HW Enhanced HE Elite HE.338 1. 1.358 7.1 23/1/5 Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 6 Technical data - size 2 Supply air fan Extract air fan 7 2 4 6 8 12 7 2 4 6 8 12 6 6 5 5 4 4 3 3 2 7 L wa, db 2 75 5 6 45 2 3 35 4 L wa, db 2 6 3 35 SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) System overview The diagrams show the available external pressure for the duct system. The weighted sound power noise levels given in db(a) apply to ducts on the supply fan s outlet side (diagram 1) and extract fans inlet side (diagram 2). The SFP v values for each fan are calculated according to clean filters. SFPv is calculated for the complete unit and includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater. electrical data External fuse: Recommended 1 A. The mains supply cable must be fitted with an external safety switch, which can cut the current to the entire unit. Ambient temperature during operation 2 - +4 C Temperature efficiency η, % 9 8 η Efficiency % dry 2) η Efficiency % wet 3) 7 2 3 35 2) According to EN38. 3) 5 C/RH 9% Outdoor and +22 C/RH 5% Extract. Filter Supply air: x 37 x 48 mm, G4 alt F7 Extract air: x 37 x 48 mm, G4 alt M5 Unit fan Motors Post Rated Rated Electrical Version Power, 2 fans Heater Power Current Supply kw kw kw A V/Ph/Hz Essential Enhanced HW.34.36 2.9 23/1/5 Elite HW Enhanced HE Elite HE.34 1. 1.36 7.2 23/1/5 Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 7 Technical data - size 3 Supply air fan Extract air fan 9 5 15 9 5 15 8 8 7 7 6 6 5 5 4 L wa, db 8 4 3 2 7 75 3 2 6 6 2 3 4 45 45 4 5 2 3 L wa, db 4 45 SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) System overview The diagrams show the available external pressure for the duct system. The weighted sound power noise levels given in db(a) apply to ducts on the supply fan s outlet side (diagram 1) and extract fans inlet side (diagram 2). The SFP v values for each fan are calculated according to clean filters. SFPv is calculated for the complete unit and includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater. electrical data External fuse: Recommended 1 A without electrical heater. Recommended 16 A with electrical heater. The mains supply cable must be fitted with an external safety switch, which can cut the current to the entire unit. Ambient temperature during operation 2 - +4 C Unit fan Motors Post Rated Rated Electrical Version Power, 2 fans Heater Power Current Supply kw kw kw A V/Ph/Hz Essential Enhanced HW.77.79 5.1 23/1/5 Elite HW Enhanced HE Elite HE.77 1.5 2.29 11.6 23/1/5 Temperature efficiency η, % 9 8 η Efficiency % dry 2) 7 η Efficiency % wet 3) 2 3 2) According to EN38. 3) 5 C/RH 9% Outdoor and +22 C/RH 5% Extract. Filter Supply air: 2 x 348 x 352 x 48 mm, G4 alt F7 Extract air: 2 x 348 x 352 x 48 mm, G4 alt M5 4 45 Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 8 Technical data - size 4 Supply air fan 5 15 2 25 9 Extract air fan 5 15 2 25 9 8 8 7 7 6 6 5 5 4 4 3 2 7 75 8 3 2 6 6 2 L wa, db 3 4 5 6 7 45 5 2 L wa, db 7 3 4 5 6 7 SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) System overview The diagrams show the available external pressure for the duct system. The weighted sound power noise levels given in db(a) apply to ducts on the supply fan s outlet side (diagram 1) and extract fans inlet side (diagram 2). The SFP v values for each fan are calculated according to clean filters. SFPv is calculated for the complete unit and includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater. electrical data External fuse: Recommended 1 A without electrical heater. Recommended 16 A with electrical heater. The mains supply cable must be fitted with an external safety switch, which can cut the current to the entire unit. Ambient temperature during operation 2 - +4 C Unit fan Motors Post Rated Rated Electrical Version Power, 2 fans Heater Power Current Supply kw kw kw A V/Ph/Hz Essential Enhanced HW 1. 1.2 4.5 23/1/5 Elite HW Enhanced HE Elite HE 1. 2. 3.2 13.2 23/1/5 Temperature efficiency η, % 9 8 η Efficiency % dry 2) η Efficiency % wet 3) 7 2 3 4 5 6 7 2) According to EN38. 3) 5 C/RH 9% Outdoor and +22 C/RH 5% Extract. Filter Supply air: 2 x 348 x 352 x 48 mm, G4 alt F7 Extract air: 2 x 348 x 352 x 48 mm, G4 alt M5 Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 9 Technical data - size 5 Supply air fan 5 15 2 25 9 Extract air fan 5 15 2 25 9 8 8 7 7 6 6 5 5 4 4 3 2 7 75 3 2 5 6 6 8 45 2 L wa, db 3 4 5 6 7 8 2 L wa, db 3 4 5 6 7 8 SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) System overview The diagrams show the available external pressure for the duct system. The weighted sound power noise levels given in db(a) apply to ducts on the supply fan s outlet side (diagram 1) and extract fans inlet side (diagram 2). The SFP v values for each fan are calculated according to clean filters. SFPv is calculated for the complete unit and includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater. electrical data External fuse: Recommended 1 A without electrical heater. Recommended 16 A with electrical heater. The mains supply cable must be fitted with an external safety switch, which can cut the current to the entire unit. Ambient temperature during operation 2 - +4 C Unit fan Motors Post Rated Rated Electrical Version Power, 2 fans Heater Power Current Supply kw kw kw A V/Ph/Hz Essential Enhanced HW 1. 1.2 4.5 23/1/5 Elite HW Enhanced HE Elite HE 1. 2.5 3.52 15.4 23/1/5 Temperature efficiency η, % 9 8 η Efficiency % dry 2) η Efficiency % wet 3) 7 2 3 4 5 6 7 8 2) According to EN38. 3) 5 C/RH 9% Outdoor and +22 C/RH 5% Extract. Filter Supply air: 2 x 398 x 47 x 48 mm, G4 alt F7 Extract air: 2 x 398 x 47 x 48 mm, G4 alt M5 Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 1 Technical data - size 6 Supply air fan 5 15 2 25 3 35 9 Extract air fan 5 15 2 25 3 35 9 8 8 7 7 6 75 6 5 5 4 4 6 3 2 6 2 7 3 2 75 L wa, db 4 6 8 2 5 6 L wa, db 4 6 8 SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) SFPv.75 SFPv [W/(l/s)] 1) SFPv.5 SFPv [W/(l/s)] 1) System overview The diagrams show the available external pressure for the duct system. The weighted sound power noise levels given in db(a) apply to ducts on the supply fan s outlet side (diagram 1) and extract fans inlet side (diagram 2). The SFP v values for each fan are calculated according to clean filters. SFPv is calculated for the complete unit and includes power to both supply and extract fan divided by either the supply or extract volume whichever is the greater. electrical data External fuse: Recommended 1 A. The mains supply cable must be fitted with an external safety switch, which can cut the current to the entire unit. Ambient temperature during operation 2 - +4 C Temperature efficiency η, % 9 8 η Wirkungsgrad % trocken 2) η Wirkungsgrad % nass 3) 7 2 4 6 8 2) According to EN38. 3) 5 C/RH 9% Outdoor and +22 C/RH 5% Extract. Filter Supply air: 2 x 398 x 62 x 48 mm, G4 alt F7 Extract air: 2 x 398 x 62 x 48 mm, G4 alt M5 Unit fan Motors Post Rated Rated Electrical Version Power, 2 fans Heater Power Current Supply kw kw kw A V/Ph/Hz Essential Enhanced HW 1. 1.2 4.4 23/1/5 Elite HW Enhanced HE Elite HE 1. 3. 4.2 8. 4/3/5 Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 11 Dimensions and weight 58 Minimum Maintenance Space Maintenance side.6 x Width Minimum W Services side.5 x Width Minimum L E C H 11.5 45 ØD ØD Unit Size L W H C ØD E W1 W2 1 16 122 38 335 25 198 217 2 16 122 38 335 25 2 219 3 19 152 425 41 25 7 263 294 4 19 152 425 41 25 7 269 3 5 2 172 47 46 315 8 28 6 248 172 685 46 5 8 495 All dimensions in mm. All weights in kg. W1 = Weight for Essential model, Standard W2 = Weight for Essential model, Acoustic Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 12 Accessories Duct mounted Cooling coil - REDZ-14 Spare filters - REDZ-81 Air cooler for cold water with copper tubes and aluminum fins. The air cooler is built into a galvanized sheet steel casing, AZ 185 with 9 mm insulation. The casing has a removable hatch for cleaning and duct connections with rubber ring seals. The air cooler has to be installed so that the distance to the fan or bend upstream of the cooler is at least 6 mm. The cooler is only available in a left-hand configuration. Venting and draining is carried out via the pipe system. The pipe connection, Ø 22 mm, is located on the outlet end, is smooth and is intended for a compression fitting. The drainage tray is in stainless steel and has an R 1/2 connection. Max. Operating pressure 1. Mpa. Max. Operating temperature C. Filter for supply and extract air have the same design and are made of compact fiberglass optimized for low pressure drop and is available in filter class G4, M5 and F7. Duct mounted pre heater - REDZ-82 Weather cover roof - REDZ-8 eco PREMIUM unit can be installed outside when a weather cover roof is fitted. The separate roof made in Aluzink is done to resist outdoor environment and fulfills the C4 class (BSK 94/99 and ISO 12944-2). An optional electric pre-heater (frost heater) is available as part of frost protection strategy and is delivered in the unit version ELITE. The heater is a stand alone device and has no electrical connection with the unit. The heater is made in Aluzink steel plate and its element in stainless steel according EN 1.431. The heater complies with protection class C to EN 15727. Built-in electronic flow switch and regulator via built-in temperature sensor in duct. Set point adjustment is set on the heater cover. Unit size Diameter [mm] Rated Power [kw] Supply voltage [V] Supply phase [nr] 1-2 25 3 23 1 3-4 25 6 4 2 5 315 9 4 3 6 4 1) 12 4 3 1) Needs a dimension change from 5 to 4. Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 13 Accessories Drain trap - REDZ-84 Standard Silencer - REDZ-86 Drain trap to provide air coming in and out from the drainage. Including two adapters. Fits both drop tray and the duct mounted cooling coils. Acoustic Silencer - REDZ-85 The standard silencer is a straight circular duct silencer with mm mineral wool filling. Duct connections have rubber seals. The silencer consists of a perforated sheet metal pipe surrounded by a galvanized sheet steel mantle and end pieces sandwiching mineral wool covered with nonwoven fabric to prevent fibre migration. Fire resistance rating EI3. The available nominal lengths are 6, 9 & 12 mm. Dia A Lenght Dia B Attenuation [db] at Octave band mid-frequency [Hz] [mm] [mm] [mm] 63 125 25 5 1K 2K 4K 8K 25 6 3-2 -7-12 -18-23 -1-5 25 9 3-2 -2-8 -19-25 -32-12 -6 25 12 3-2 -4-11 -25-3 -39-14 -1 315 6 415-2 -7-1 -15-2 -7-4 315 9 415-1 -2-7 -16-22 -24-1 -6 315 12 415-2 -4-1 -22-28 -3-12 -9 5 9 63-1 -1-5 -11-14 -12-9 -6 5 12 63-1 -3-7 -16-2 -15-1 -7 Rectangular version for eco PREMIUM 1-4 and is recommended for areas where no breakout between unit and duct is allowed. The silencer consists of a galvanized sheet metal casing, absorbent material in coated glass wool and end pieces with rubber gaskets. One side consists of female spigot in order to get close to unit without any breakout noise. The available nominal length is mm. Size Way Ø [mm] L [mm] W [mm] H [mm] Attenuation [db] at Octave band mid-frequency [Hz] 63 125 25 5 1K 2K 4K 8K 1, 2 F/E 25 95 38-6 -6-1 -19-3 -27-16 -14 1, 2 S/E 25 95 38-8 -8-13 -23-34 -3-17 -14 3, 4 F/E 25 95 131 425-7 -7-11 -2-31 -28-17 -15 3, 4 S/E 25 95 131 425-9 -9-14 -24-35 -31-18 -15 F/E = Fresh/Extract air S/E = Supply/Exhaust air Ø = Diameter spigot L = Length W = Width H = Height Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 14 Accessories Shut off damper with actuator - REDZ-87 Mounting feet - REDZ-88 Duct mounted damper in leakage class 3 (CEN 3). The damper is made of galvanized sheet steel and has a spring return on/off actuator mounted on it. The actuator is connected to a terminal block in the electrical cabinet. The damper has a duct connection with a rubber ring seal and it can be mounted directly onto the unit or into the duct. It is designed for duct insulation of up to 5 mm. At air speeds below 1 m/s and the damper fully open the sound power level is below 2 db. A spring return shut-off damper should be used for units with a water coil. IP 54. The unit can be mounted directly onto the surface if this is flat and horizontal. The height of the mounting feet can be adjusted between 15-85 mm. Rubber feet are included in the kit. Weather cowl kit - REDZ-89 Outside wall cowl for outdoor air and exhaust air. The cowl comes with bird guard net and is made of Aluzink to resist outdoor environment. It fulfills the C4 class (BSK 94/99 and ISO 12944-2). The size allows to have a shut off damper (REDZ-87) mounted on the unit. Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 15 Controls General eco PREMIUM is delivered with the integrated control platform Curo and the belonging control panel, Curo Touch. All internal components are prewired and the eco PREMIUM is factory tested. The controls are easy to use. The control equipment can communicate via Modbus RS485 or Modbus TCP/IP. For adjustments and settings use the control panel Curo Touch. Standard control functions Fan speed control VAV, Variable air volume (supply and extract) Temperature control Supply air control Communication Modbus RS 485 Fan monitoring Fire Protection system Night cooling Cooling recovery Frost protection, standard with a unit equipped with water heater coil Schedule Demand controlled defrosting (Thermo Ice) Accessories /open options Fan speed control CAV, Constant Air Volume COP, Constant Pressure (supply and exhaust) VAV, Variable Air Volume with CO 2 function Temperature control Extract air control Room control Outdoor air compensation Communication Modbus TCP/IP Filter monitoring Extended and / or forced operation External timer PIR Standard control functions Fan speed control - VAV Fan speeds are set individually between 3-% Temperature control Supply air control Constant supply air temperature is maintained. Communication eco PREMIUM is delivered with BMS communication (MODBUS RS-485) Fan monitoring The controls will stop the unit and generate an alarm if the flow of the fans is too low. Fire protection A separate fire protection system may be connected to the unit. Function: stop the unit. Night cooling (free cooling) Night cooling is used during warm summer nights in order to reduce the indoor temperature. This is done by cooling down the warm indoor temperature with cold outdoor air. Cooling recovery When there is a cooling demand the unit will automatically close the bypass to cool the supply air. It happens when the extract air temperature is lower than the outdoor air temperature and there is a cooling demand. Schedule The controller has three types of internal time schedules, Weekly, Single date and Date period. Defrosting (Thermo ice) eco PREMIUM uses an advanced defrosting function that ensures that the annual heat recovery efficiency is as high as possible. During cold periods if icing has occurred on the counter flow heat exchanger then the defrosting function will stop the supply fan and start the defrosting process. The defrosting function will only be active when necessary, a large part of the counter flow needs to be iced before the defrosting function starts. Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 16 Controls cont. Accessories /open options Safety switch - REDZ-39 Fan speed control REDA-a-b-cc-d-e-ff Different fan speed control is available to individually adjust the airflow for supply and exhaust side. The following options can be selected and will automatic be handled by the CURO Control. COP. Constant Pressure CAV. Constant Air Volume VAV+CO 2. Fan speeds are set individually, overrides by the demand ventilation (CO 2 ) when the set PPM value is exceeded. Temperature control REDZ-1 Extract air control Constant extract air temperature is maintained via cascade regulation of the supply air temperature with min- and max temperature limits. The mains supply cable must be fitted with an external safety switch, which can cut the current to the entire unit. Is available in 16A & 25 A. Extended forced operation - REDZ-4 Room air control Constant room air temperature is maintained via cascade regulation of the supply air temperature with min- and max temperature limits. Outdoor air compensation The function offsets the set point of the supply air temperature. Not available with extract- or room air control. External timer PIR Communication - REDZ-5 eco PREMIUM can be delivered with Modbus TCP/IP via separate Ethernet card. Filter monitors - REDZ-28 External timer (setting -5 hours) or occupancy detector (PIR). Both for external and recessed mounting. Coil control - REDZ-7 Air heater Control signal (-1V) for a valve actuator. Freeze protection: When the unit is not in operation mode the water temperature will be held constant at 25 C. During operation mode the valve will be controlled so that the returned water temperature will not be below 15 C. The unit will be stopped and an alarm will be activated If the returned water temperature is below 7 C. Air cooler Control signal -1 V for air cooler, water. The controls will generate an alarm if the pressure drop over each filter exceeds set value. Valve actuator for air heater/ cooler Valve actuator customized to fit a valve with a 5.5mm and G3/4 thread. Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 17 Product Code Energy recovery unit Accessories eco PREMIUM REDA-a-b-cc-d-e-ff Temperature control REDZ-1-b Size (a) 1 = Size 1 2 = Size 2 3 = Size 3 4 = Size 4 5 = Size 5 6 = Size 6 Control situation (b) 2 = Extract air control 3 = Room control 4 = Supply air control with outdoor air compensation Communication Type (b) 1 = Ethernet Card REDZ-5-b Inspection side (b) 1 = Right standard 2 = Left standard 3 = Right acoustic casing (Only a = 1-4) 4 = Left acoustic casing (Only a = 1-4) Unit variants (cc) = Essential 1 = Enhanced electrical 2 = Enhanced hot water 3 = Elite electrical 4 = Elite hot water Filter (supply / exhaust) (d) 1 = G4 compact/ G4 compact 4 = F7 compact / M5 compact Fan speed control (e) 1 = VAV, Variably Air Volume, (Supply exhaust) 2 = COP, Constant Pressure, (Supply exhaust) 3 = CAV, Constant Air Volume, (Supply exhaust) 4 = VAV+CO2 function (int. as standard) Language (ff) 3 = English Duct mounted cooling coil Size (b) 1 = Size 1 2 = Size 2 3 = Size 3 4 = Size 4 5 = Size 5 6 = Size 6 Type (c) 1 = Water Connection side (d) 1 = Right 2 = Left Filter monitor Function (b) 1 = Filter monitor Safety switch Current (bbb) 16 = 16 A 25 = 25 A Extended/forced operation Variant (b) 1 = External timer, electronic (1-5 h) 3 = PIR Type (c) 1 = Standard REDZ-14-b-c-d REDZ-28-b REDZ-39-bbb REDZ-4-b-c Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 18 ACCESSORIES Coil control Scope of supply (b) 1 = Actuator only 2 = Valve with actuator 3 = Valve only Type of valve (c) = Without (only if b = 1) 2 = 2-way 3 = 3-way Location (d) 1 = Heating 2 = Cooling Kvs-value (eee) = Actuator only (only if b = ) 2 =.25 4 =.4 6 =.63 1 = 1. 16 = 1.6 25 = 2.5 4 = 4. = 1. CURO Touch Extra cable REDZ-7-b-c-d-eee REDZ-76-bb Spare filter Size (b) 1 = Size 1 2 = Size 2 3 = Size 3 4 = Size 4 5 = Size 5 6 = Size 6 Type (c) 1 = G4 (2 pcs) 2 = M5 (2 pcs) 3 = F7 (2 pcs) Pre Heater, duct mounted Size (b) 1 = Size 1 2 = Size 2 3 = Size 3 4 = Size 4 5 = Size 5 6 = Size 6 Drain trap Type (b) 1 = Standard REDZ-81-b-c REDZ-82-b REDZ-84-b Length (bb) 1 = 1 meters 25 = 25 meters Weather cover, roof Size (b) 1 = Size 1 2 = Size 2 3 = Size 3 4 = Size 4 5 = Size 5 6 = Size 6 REDZ-8-b-c Acoustic Silencer Size (b) 1= Size 1 and 2 2= Size 3 and 4 Standard Silencer Diameter (bbb) 25 = 25 mm 31 = 315 mm 5 = 5 mm REDZ-85-b REDZ-86-bbb-ccc Type (c) 1 = Standard Length (ccc) 6 = 6 mm 9 = 9 mm 12 = 12 mm Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

eco PREMIUM - Technical Instruction REDA 19 Shut off damper with actuator Size (bbb) 25 = 25 mm 31 = 315 mm 5 = 5 mm REDZ-87-bbb-c Type (c) 2 = On-Off, Spring-return Mounting feet Size (b) 1 = Size 1-4 2 = Size 5-6 Weather Cowl Kit Size (b) 1 = Size 1 2 = Size 2 3 = Size 3 4 = Size 4 5 = Size 5 6 = Size 6 REDZ-88-b REDZ-89-b-c Type (c) 1 = Standard Fläkt Woods 9 GB 217.5.11 Specifications are subject to alteration without notice

FWG-eCO PREMIUM Technical instructions-gb-217.5.11 9GB Copyright 215 Fläkt Woods Group We bring better air to life www.flaktwoods.com eco PREMIUM 9GB 217511 With over a century of innovation and expertise to share with our customers, Fläkt Woods is a global leader in Air Technology products and solutions. We specialize in the design and manufacturing of a wide range of products and solutions for Air Movement, Air Treatment, Air Distribution, Air Management and Air Diffusion with focus on two major benefits Air Comfort and Fire Safety. With market presence in countries we are in a unique position to be a local supplier and an international partner in our customer s projects. Our product brands such as RegAsorp, eq, eq Prime, JM Aerofoil, Econet, Veloduct, Optivent, Optimix, Econovent and Cleanvent are well-known and trusted by customers all over the world to deliver high quality and energy efficient solutions.» To learn more about our offering and get in contact with your nearest sales representative please visit www.flaktwoods.com