MYSON ELECTRIC UNDERFLOOR HEATING. INSTALLATION MANUAL. heatingthroughinnovation. APRIL 2013

Similar documents
ELECTRIC UNDERFLOOR HEATING

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

Electrorad Digi-Line. Installation, Operating & Instruction Manual. After Sales Service:

DC Disconnect with remote control and arc fault detection PVREM-...-AF1

Dynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control

Undercounter Dishwasher

Fire Alarm Panel - User Manual

Ceramic insulated band heaters

Underc Dishwasher. IMPORTANT: Read and save these instryctions. 8

SKYSTAR water cassette Main components:

Clean and simple waste water removal

Operating Instructions OPTISWITCH 3100 C with transistor output

Thermo shaker PHMP/ PHMP-4

Undercounter Dishwasher

Operating Instructions OPTISWITCH 3100 C with contactless electronic switch

INSTRUCTION MANUAL AND WARRANTY

Mica insulated band heaters

ANALOGUE FIRE DETECTION SENTRI SYSTEM

Our home standard. Your home is where our heart is...

Thermo shaker PHMP/ PHMP-4

Nexus 1-8 Loop (A1557) Analogue Addressable Control Panel Application Guide

Small is beautiful and useful anywhere... Electric "Point of Use" Water Heaters "Open-Outlet" for single outlet "Unvented" for one or more outlets

BC80A compact product catalog.

INDIA S MOST POWER SAVING INVERTER AC

List of Contents Air Top 2000 NOTE

REFRIGERATOR-FREEZER 8ET17NK 3ET16NK. Use And Care Guide. ~qq

Mica insulated flat heaters

ANCILLARY DEVICES. Contents. Fire System Document Box. EN54-4 Approved Power Supply Units. Transformer Rectifier 24v Door Retainer Power Supply Units

30 and 36 m Sealed Burner

Operating Instructions OPTISWITCH 3100 C with contactless electronic switch

Take control with... Energy Efficient Controls

SSimdex and Power-Limited Fire Alarm Systems Operating and Installation Instructions

Turbosteam iron steam/spray/steam boost

36 Electric Modular Downdraft Cooktop

UseAndCare I 301 Call our Consumer Assistance Center with questions or comments. 22 TO 25 NO-FROST TOP FREEZER REFRIGERATOR

iii. Compatible Loop Devices and Panel Responses 27 IMPORTANT NOTE: Read the instructions carefully before commencing installation and commissioning.

UseAndCare. T&f1 HOme Appliances 01. A Note To You. Important Safety Instructions. Parts And Features. Using Your. Refrigerator. Caring For Your 15

UseAndCare. TLidl Call our Consumer Assistance Center with questions or comments.

UseAndCare. TKYl or 9 lkwtomakeahoml~ I 301 Call us with questlons or comments. MICROWAVE OVEN MODELS MT7076XD Ml7078XD

UseAndCare. Whifl 01 d HOme Appliances. A Note To You 2. Important Safety Instructions 3. Parts And Features 4. Before Using Your Refrigerator 5

Installation and Operating Instructions

ARG 1

Operating Manual. Model Coolant Exchanger

. I w Undercounter Dishwasher. IMPORTANT: Read and save these instructions. 5(43. Part No

General terms and conditions... F-7 Glossary of terms... P.1455~ panasonic.net/id/pidsx/global

UseAndCare. l Call our Consumer Assistance Center with questlons or comments. 18 TO 20 NO-FROST TOP FREEZER REFRIGERATOR

UseAndCare I 301 NO-FROST REFRIGERATOR-FREEZER

ORDER GUIDE. 5 m ft cable length type. Accessories. Robust Photoelectric Sensor RX SERIES

Pilkington Decorative Glass Range. Pilkington Texture Glass Pilkington Oriel Collection Pilkington Optifloat Opal

HAZARDOUS AREA. The very best in high pressure water jetting systems SURFACE PREPARATION/ COATING REMOVAL PIPE CLEANING HEAT EXCHANGER CLEANING

CONVENTIONAL FIRE DETECTION

NO-FROST REFRIGERATOR-FREEZER. Use And Care Guide l!i7-96

UseAndCare. VL#l 01. A Note To You 2. Important Safety Instructions 3. Parts And Features 4. Before Using Your Refrigerator 5

Spray Etching Device

INUI-LEDSDL10 Specification

SELF-CLEANING DESIGNERSTYLE ELECTRIC SET-IN RANGE

UseAndCare. A Note to You 2. Parts and Features 6. Using Your Range 7. Using the Setf- Cleaning Cycle 20. Warranty

UALITY ONTROL. Thermal processing equipment for laboratories

NO-FROST REFRIGERATOR-FREEZERS Ell8DK Ell8RK

Motion & Presence Detectors

UseAndCare. -. wh H 01. nawtouua*naur~- I Call our Comumw Aubtmnca Center with quwiion* cf ccmmonb. AIR CONDITIONERS

ComfiGrip iron steam/spray/shot/press

UseAndCare. /z/95. l Call us with questions or comments. NO-FROST REFRIGERATOR-FREEZER ET1 4CKXE ET1 4NKXE

DETERGENT & RINSE AID INJECTION

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output

Take control with... 1

. Ev d & AUTOMATIC WASHER

AUTOMATIC MARINE AND RV TOILETS

UseAndCare. Tikll I 301 Call us with questions or comments. MODEL RF354BXD

Use & Care Guide. SELF-CLEANINGAS RANGE SF370PEW (Shown) SF365BEW. Stop time w Clean indicator light. Oven vent \ Burner grates

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Operating Instructions KSR-TF 633 with transistor output

DESIGN AND APPLICATION GUIDE VISUAL ALARMS

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output

Operating Instructions KSR-TF 611 with transistor output

Globo H. Ball valves Gunmetal ball valve

ACTIVESMART FRIDGE 900MM FRENCH DOOR SLIDE-IN WITH ICE & WATER

Instructions for Installation and Use 50cm Free Standing Electric Cooker

by Honeywell THE VIGILON SYSTEM BROCHURE

ASPIRATING SMOKE DETECTION SYSTEMS

Domestic applications of gas

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS Models: 1000-CH-D SERIES

a guide to watering your garden

INSTALLATION INSTRUCTION

STANDARD-CLEANING ELECTRIC RANGE

VRV T-Series WATER-COOLED SYSTEMS 10.17

AND GAS DRYERS. A Note To You 2. Understanding Safety 3. Knowin Your Dryetis B eatures 5. Operating Your Dryer 6. Laundry lips 19

MANUAL DE INSTALACIÓN

Caleo Neonatal incubator Software 2.n Instructions for Use Emergency Care Perioperative Care Critical Care Perinatal Care Home Care Because you care

A Note To You 2. Understanding Safely 3. Knowin Your Dryer s F eatures 5. Operating Your Dryer 6. Laundry Tips 16. E2tE 22.

Useful tips to keep you safe and save you money

c P UseAndCare I ROPER Call us with questions or comments. J3ome Appliances

Royal Sovereign Brochure

Forest help when you need it To order or for more information visit or call

UseAndCare. lq l 301 Call our Consumer Assistance Center with questions or comments.

Buderus. Quality Doesn t Cost It Saves! Comfortable. Efficient. Intelligent Heating. GA124 GA244 Gas Boilers Sealed Combustion Draft Induced.

We see cooking not as a chore, but a creative act. As more of our lives become virtual and people look for ways to make and create things, we design

Operator s Manual COUNTERTOP CONVECTION OVEN ENGLISH. Item Model Description Shelves

UseAndCare. A Note To You 2. yg~~ ~af61 3. Parts And Features 4. Before Using Your Refrigerator 6. Using Your Refrigerator 8.

KaMo manifold systems

Transcription:

MYSON ELECTRIC UNDERFLOOR HEATING. INSTALLATION MANUAL APRIL 2013 Important: Pease read carefuy on receipt of product and keep in a safe pace. heatingthroughinnovation.

Contents 1.0 Genera Information 03 2.0 Preparation 04 3.0 Measuring the Mat and Instaation 05 4.0 Measuring Vaues/Resistance with the Mutimeter 09 5.0 Connecting the Thermostat 10 6.0 Thermostat User and Instaation Guide 10 7.0 Eectrica Connection 13 8.0 Technica Data 14

Eectric Underfoor Heating 03 1.0 Genera Information The MYSON mat is manufactured from high quaity, durabe materias. To guarantee that your product functions optimay there are a few points of attention which are described in the instaation manua. We can ony offer you the fu guarantee if the mat is correcty instaed in accordance with the instaation manua. Carefuy read the instructions prior to instaation and ensure that you have the correct toos and materias. PLEASE NOTE: The eectrica instaation MUST BE carried out by a quaified eectrician. Before instaing check if the heating mat is the right size for the foor area to be heated and that there is sufficient eectrica capacity (Amps) avaiabe. The mat shoud not be positioned over expansion joints. If mutipe mats are instaed in an area then a shared power point can be instaed so that ony 1 power cabe runs to the thermostat. Maximum capacity of the thermostat is 16 Amps. The thermostat shoud be instaed by a quaified eectrician. The power suppy must be turned off during instaation. The MYSON mat consists of a heating cabe of 8-9 Watts per metre that is equay distributed and connected to a gass fibre net with an inter-oop distance of approximatey 70mm. Each mat is tested at the factory and has a unique inspection card. Every mat is tested at 4000 vot. You must check the mat after each instaation phase, in order to know at which phase any defect occurs (section 4.0). The heating cabe, attached to the grey gass fibre net, must NOT be broken. The mats must NOT be aid over each other and the heating cabes must NEVER cross each other. The cabe junction (where the power suppy cabe joins the heating cabe) is just within the heating mat and is marked. The mat has 1 connecting cabe, which is 5 metres in ength. The connector cabe MUST NOT be shortened by more than 3 metres, there must therefore aways be at east 2 metres of connecting wire eft. The power suppy must be turned off during instaation. The heating mat is 3-4 mm thick and must be incorporated in an adhesive or screed suitabe for foor heating. Check the manufacturer s data. A distance from the wa of 100mm shoud generay be adhered to. The mat may never be instaed under fixed objects ike wa units, kitchen units, baths or showers and must be abe to give off its warmth unimpeded. The MYSON mat may ony be incorporated into the free foor/wa areas. As many bathrooms consist mainy of a sma free foor area the mat may ony be instaed as suppementary heating. Pease contact your heating engineer who wi advise the heating requirement of the room. The sensor MUST be instaed in the midde of a cabe oop for optima temperature registration. Ensure that the sensor is instaed we cear (min. 500mm) of hidden radiator and water pipes, drains and eectrica wiring. The sensor MUST aways remain in the sensor pipe. Cap the end of the pipe to avoid the sensor getting stuck during instaation. If the sensor ever needs to be repaced it can then easiy be removed. A sufficienty strong and thick compression resistant foor, with or without reinforcing, must be appied on wood and insuation. If this is not the case pease contact Customer Services and enquire about our other products. The eectric heating mat is guaranteed for 10 years. The thermostat is guaranteed for 2 years. The guarantee does not appy to damage caused by externa factors and/or incorrect instaation. In compiance with the EU Directive 2006/66/EC, the button ce battery ocated on the printed circuit board inside this product, can be removed at the end of the product ife, by professiona personne ony. MAT 2 2 2 THERMOSTAT

04 Eectric Underfoor Heating 2.0 Preparation Check the contents of the box before starting. A compete set wi consist of: Heating mat with connecting wire Contro card Digita cock thermostat inc. foor sensor Fexibe sensor pipe Mutimeter Instaation manua 2.1 Preparation: Necessary Materias A MYSON mat system. Fexibe tie adhesive or eveing/screed and grout suitabe for foor heating. Fexibe cement and cement gun for expansion joints aong the was. Approx. 2m fexibe eectrica piping (16mm). Pastic gue comb with approx. 6mm teeth. Eectrica junction box (min 40mm deep). Power outet with RCD 30mA. Adhesive or doube sided tape (for screeded foors). 2.2 Preparation: Pacing the Thermostat Determine where the thermostat is to be paced. Pace a standard eectrica junction box*, preferaby at a height of 1.5m for ease of operation. Grind/cut the necessary grooves (fig 1) and mount the junction box and suitabe sheathing/conduit to aow pastering after instaation. Cut a groove in the foor for the foor sensor pipe 20mm deep (fig 2). Feed the sensor through the fexibe pipe (fig 3). The sensor must aways remain in the fexibe pipe. Cap the end of the pipe (fig 4) to avoid the sensor getting stuck during instaation. If the sensor ever needs to be repaced it can then easiy be removed. Ensure that the surface where the mat is worked on is fat, cean, and free of dust and grease. In arger spaces pace the edge strips/expansion joints aong the wa. Fig. 1 Fig. 2 Fig. 3 Fig. 4 PLEASE NOTE: Never pace the sensor in the vicinity of a hidden radiator pipe and never insta it passing under a heating cabe. The sensor MUST aways remain in the fexibe pipe. * See Section 7.0 Eectrica Connection.

Eectric Underfoor Heating 05 3.0 Measuring the Mat and Instaation Preparation Test the mat before commencing instaation to ensure there are no fauts. Aow a distance from the wa of 100mm when roing out the matting. This does not appy to conservatories where extra heating is required. The oose cabes must be ooped at east 40mm from each other. They shoud not touch or cross each other. Retest the mat when it has been aid (section 4.0). If the mat is too ong it can be foded 180 o (fig 5), for exampe, by cutting through the fibre netting without damaging the heating cabe (fig 6). This can be repeated a number of times (fig 7). If the mat is sti too ong the cabe can be cut oose from the fibre netting and instaed in oose strips, pease see section 3.3. Using the System for the First Time Aow the foor sufficient drying time before you turn on the foor heating. The foor s drying time depends on many factors ike room temperature, ventiation and moisture. Generay the drying time for foor cement is 3 to 4 weeks. Pease verify this with the foor cement/screed manufacturer. Tie Cement Unro the MYSON mat with the heating cabe facing down so that ony the gass fibre netting is visibe (fig 8). Fig. 5 Fig. 6 Fig. 7 Screed Unro the MYSON mat with the heating cabe facing up. This prevents the gass fibre netting foating on the eveing screed. If necessary, the mat can aso be attached using doube sided adhesive tape. Fig. 8

06 Eectric Underfoor Heating 3.1 Instaation: Tie Cement Appy a first ayer of cement of 5mm to 10mm thick and approximatey 550mm wide (fig 9). Test the mat again (section 4.0). Smooth it over and aow it to dry. Pu the end of the connecting cabe through the eectrica piping to the thermostat (fig 10). Ro the mat out over the tie cement with the cabe facing downwards (fig 11). Then appy a second ayer of tie cement taking care to avoid air bubbes using a pastic tie cement comb to avoid damaging the heating mat (fig 13). Softy push the mat down with a wooden instrument or goves and spread the tie cement that oozes through the mat (fig 12). Test the mat again (section 4.0). Press down the tie with a ight siding motion (fig 14). Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 Fig. 14

Eectric Underfoor Heating 07 3.2 Instaation: Screed Position the mat as described in section 3.0. Attach the mat to the foor with adhesive or doube sided tape (fig 15-17). Test the mat again with a mutimeter (section 4.0) and write down the readings on the contro card. AT THIS STAGE YOU SHOULD HAVE TESTED YOUR MAT 3 TIMES. Read the instructions of the eveing screed, check that the product is suitabe for foor heating and foow the aying instructions of the manufacturer. Observe the manufacturer s drying time and then appy the foor covering (fig 18). PLEASE NOTE: Appying 2 separate eveing ayers, one on top of the other, is NOT RECOMMENDED because it can cause unnecessary tension in the foor. Fig. 15 Fig. 16 Fig. 17 Fig. 18

08 Eectric Underfoor Heating 3.3 Instaation: Laying Variations The mat can be aid in severa ways, as iustrated in diagram beow: Never cut the heating cabe. PLEASE NOTE: Heating wi ony occur where the mat has been instaed. Never cross the heating cabes. Visit our website to use our Foor Pan Cacuator. 3.4 Instaation: Laying Exampe Pease note that where there is no matting instaed the foor wi not be heated. If the mat is too ong the cabe can be cut oose from the fibre netting and instaed in oose strips. The oose cabes must be ooped at east 40mm from each other. They must not touch or cross each other. See section 3.3 above. The sensor must be instaed in the midde of a cabe oop for optima temperature registration. Ensure that the sensor is instaed we cear (min. 500mm) of hidden radiator and water pipes, drains and eectrica wiring. The mat must never be instaed under fixed objects ike wa units, kitchen units, baths, or showers and must be abe to give off its warmth without being obstructed.

Eectric Underfoor Heating 09 3.5 Instaation: Other Possibiities You can aso use any section that you have eft over within the wa or a step to the bath. You can incude it in the paster ayer or appy it with tie cement. This maximises the effective heating area from your mat. TIP: A MYSON Towe Warmer wi give you the comfort and convenience of warm dry towes, to add to the uxury of your warm foor. This may aso give the benefit of additiona heat. Pease contact Customer Services on 0845 402 3434 for a Design Coection brochure. 4.0 Measuring Vaues/Resistance with the Mutimeter Connect the wires to the mutimeter (fig 19). Turn the knob of the mutimeter to the Ohm 2000 position (fig 20). Connect the red and back probe to the connection wires (fig 21). The connection wires (Phase and Neutra) have a cear insuation sheath. Do not touch the wires when measuring. Check readings according to the contro card which was attached to the heating mat. If readings are not within a 5% margin pease check again to make sure. Pease ca 0845 402 3434 and cease instaation if readings are not within a 5% margin. Connect the RED probe to one of the connection wires and the BLACK probe to the Earth wire (fig 22). Earth wire has no sheath. Repeat this step with the RED probe to the other connection and BLACK probe to the Earth wire. Reading on the mutimeter now shoud be 1. If you read any resistance there is a possibe break in the wires. Pease check again. Pease ca 0845 402 3434 and cease instaation if reading sti shows resistance. Fig. 19 Fig. 20 Fig. 21 Fig. 22

10 Eectric Underfoor Heating 5.0 Connecting the Thermostat Mounting: The controer shoud be mounted in a ocation of the room that is easiy accessibe for operation purposes. Fitting In a conduit box Ø 60 mm (fig 23). Remove the dispay unit Remove the frame Mount it foowing the reverse procedure The pastic tab must be in pace to provide insuation between the terminas/wires and the mounting screw (fig 24). To insert or remove a fexibe wire press pin (fig 25) CAUTION: Mounting in pastic wa boxes ony. Fig. 23 Fig. 24 Fig. 25 6.0 Thermostat User and Instaation Guide For fu operating instructions, pease refer to the instructions suppied with the product. Principe of Operation: The MYSON Programmabe Foor Temperature Controer aows programming switching events and temperatures according to persona needs. After instaation the device automaticay shows the time of day and the foor temperature. In AUTO mode, the heater wi be automaticay activated according to programmed time and temperature. Programme 1 is activated (see page 11). The foor temperature wi be controed according to the temperature measured by the remote sensor. The heater wi be switched on when the temperature drops beow the current set-point. Instaation: CAUTION! This device must be instaed by a quaified eectrician, according to the wiring diagram on the device and in compiance with a appicabe safety reguations. To maintain compiance with Protection Cass II, user access to the rear of the device must be prevented. This device is used to contro the temperature ony in dry rooms, under norma environmenta conditions. This eectronic device conforms to EN 60730, it is an independenty mounted contro and works according to operating principe 1C.

Eectric Underfoor Heating 11 6.0 Thermostat User and Instaation Guide (cont...) Features: One ine text dispay for simpified operation Back ight Rea time cock (setting of year, month, day and time) Automatic Summer - Winter time change over Max 9 events per day (each day independenty) Pre-set and adjustabe programmes Optimum Start Arm chair programming (with dispay unit removed) OFF Function, Key V to be pressed for 10 seconds Hoiday Mode (date from unti can be set) Timer (Party) specific temperature for configurabe duration Energy consumption dispay (heating on time * cost) for ast 2 days, week, month, year Energy cost per hour configurabe Frost protection Range imits for adjusting max and min temperature Access protection Operating anguage can be seected Contro mode PWM or ON/OFF Minimum output ON/OFF time and hysteresis configurabe for ON/OFF contro Foor temperature can be read as a number Pre-set Programmes: There are 3 pre-set time/temperature programmes in the controer. Pre-set programme 1 (as shown beow) is the defaut. Therefore, if pre-set programme 1 is the best programme to suit the appication, there wi be no need to change the time/ temperature settings on the device. To seect another programme choose from the other options beow. PROGRAMME 2 Monday to Friday Events 1 2 3 4 5 6 Time 6:00 8:00 12.00 14.00 19:00 22:00 Temp C 28.0 18.0 28.0 18.0 28.0 15.0 Saturday and Sunday Events 1 2 3 4 5 6 Time 8:00 10:00 12:00 14:00 19:00 22:00 Temp C 28.0 18.0 28.0 18.0 28.0 15.0 PROGRAMME 1 Monday to Friday Events 1 2 3 4 Time 6:00 8:00 19:00 22:00 Temp C 28.0 18.0 28.0 15.0 Saturday and Sunday Events 1 2 3 4 Time 8:00 10:00 19:00 22:00 Temp C 28.0 18.0 28.0 15.0 PROGRAMME 3 Monday to Friday Events 1 2 3 Time 11:00 13:00 22:00 Temp C 28.0 18.0 15.0 Saturday and Sunday Events 1 2 3 4 Time 8:00 10:00 19:00 22:00 Temp C 28.0 18.0 28.0 15.0

12 Eectric Underfoor Heating 6.0 Thermostat User and Instaation Guide (cont...) Notes for Programming Activated settings terminate automaticay 3 minutes after the ast key press, without saving. They return to the mode which was active before entering the settings, e.g. AUTO, MAN, etc. Entering a Code: change vaue with the + or - key then press OK. Refer to the user guide suppied with the product. Troubeshooting Probem Possibe Causes The cock and programme events may not be set correcty It is getting warm too ate The Optimum Start feature may not be switched on - refer to Optimum Start within the user guide (H7) Did the controer have enough time (severa days) to adapt to the room s characteristics? An automatic change between Summer - and Winter time may not be activated - refer to Summer/Winter time changeover within the user guide (G5) The controer does not accept any changes The access protection may not be switched on - refer to Key Lock within the user guide (G6) The range of temperature setting is imited The temperature imits may not be set - refer to temperature imits min/max within the user guide (G7)

Eectric Underfoor Heating 13 7.0 Eectrica Connection CAUTION: DISCONNECT ELECTRIC CIRCUIT FROM SUPPLY. Connect according to Wiring Diagram (fig 26). For fexibe or soid wires 1-2.5mm 2. CAUTION: Maximum ength of removed cabe insuation 8mm. 50 42.5 17.5 N L 230V~ 50Hz Load 80.5 N N L Sensor Dimensions (mm) Fig. 26 Connecting the Remote Sensor CAUTION: The sensor is at mains votage. The MYSON Programmabe Foor Temperature Controer needs a remote temperature sensor. This sensor shoud be mounted in such a way that the temperature which has to be controed can be measured correcty. Lay sensor inside a protective tube (simpifies repacement). The sensor ead can be extended up to 50m by using a cabe and connections suitabe for 230V. Avoid aying sensor cabe aongside power cabes, for exampe inside a conduit. 20 Ø7.8 Dimensions (mm) Fig. 27

14 Eectric Underfoor Heating 8.0 Technica Data Type m 2 Wattage Amps Heat Outputs Ohm 1 150W 1.5 225W 2 300W 2.5 375W 3 450W 3.5 525W 4 600W 4.5 675W 5 750W 6 900W 7 1050W 8 1200W 9 1350W 10 1500W 0.65 0.97 1.30 1.63 1.95 2.28 2.61 2.93 3.26 3.91 4.56 5.22 5.87 6.52 353 235 176 141 117 100 88 78 70 59 50 44 39 35 Order type Suppy votage Temperature setting range Temperature resoution Output reay Switching current Output signa PWM cyce time Hysteresis Minimum programmabe time Power consumption Accuracy of cock Power reserve Programmabe Foor Temperature Controer 230 V AC 50 HZ (195... 253 V) 10 C to 40 C; in 0.5 C steps 0.1 C steps NO contact 10mA... 16(4)A AC*; 230 V~ PWM (Puse Width moduation) or ON/OFF adjustabe adjustabe (ON/OFF ony) 10 Min ~ 1,2 W < 4 Min / year ~ 10 Years Remote sensor F 193 720, ength 4m, can be extended up to 50m Ambient without condensation temperature - Operating 0 C 40 C - Storage -20 C 70 C Rated impuse 4 kv votage Ba pressure test 115 C Votage and 230V, 0,1A Current for the purposes of interference measurements Degree of IP 30 protection Protection cass II (see Caution) of housing Poution degree 2 Software cass A Weight ~280 g (with remote sensor) NB. For current > 14 A do not oop the N-wire through the controer, use a separate termina.

Eectric Underfoor Heating 15 8.0 Technica Data (cont...) Resistance Vaues for Remote Sensor Temperature C 10 20 25 30 40 50 Resistance k 66.8 41.3 33.0 26.3 17.0 11.3 PLEASE NOTE: On a these errors, heating wi be activated with 30% of time. Error Indication: In case of errors, "Err" is binking. The foowing errors can be dispayed: CONFIGURATION Dispay and powermodue do not fit use ony suitabe parts switch off and on power suppy COMMUNICATION Communication between dispay and power unit fais unpug and re-pug dispay unit switch off and on power suppy EXTERIOR SENSOR 1. Error of remote sensor repace sensor 2. Over or under run of vaid dispay range Pease ca customer services on 0845 402 3434 or visit www.myson.co.uk for more information or after saes advice. Scan the QR code to use our Foor Pan Cacuator.

MYSON MYSON Eastern Avenue, Team Vaey, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, saes@myson.co.uk, www.myson.co.uk 01.04.2013 heatingthroughinnovation.