FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

Similar documents
Tri-Mer Packed Bed Tower Scrubbers

COMPOSITE MESH PAD (CMP) DRY SCRUBBERS ENFORCER III TM III

Enviro International Corporation. WET SCRUBBER

INSTALLATION OPERATION MAINTENANCE

INSTALLATION OPERATION MAINTENANCE

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Paragon. Induced Draft, Counter Flow Optional Accessories

MODEL NUMBER NOMENCLATURE

TM Series. Induced Draft, Counter Flow Optional Accessories

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

INDUSTRIAL CONDENSATE POLISHERS. LWTCP Series

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

A. Codes and Standards that are Standard at the University:

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

COMPOSITEOMPOSITE MESHESH PADAD (CMP)

SECTION COOLING TOWERS

SECTION COOLING TOWERS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

hinged tops or hinged doors.

Providing State-of-the-Art Fine Particulate Control Through Advanced High Energy Ionization

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

GIRTON TREE, TUB, AND CART WASHER MODEL 80-O

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Effectively clean rubber footwear with a BSX Boot Scrubber

SECTION AIR DUCT ACCESSORIES

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Model GW1020 Laboratory Glassware Washer General Specifications

PROBATCH MODEL H. Optimize Your Polymer Performance

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

3500 CFM TECHNICAL SPECIFICATIONS MIDWEST VACUPAC BIN VENT AND CONVEYOR TRANSFER POINT DUST CONTROL SYSTEM SERIES MBV 43 F MBV 43 C MBV 37 C MBV 54 F

AccuBrine automated brine maker Technical Specifications

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

SPECIFICATIONS GIRTON PALLET WASHER MODEL CW10PS

BASIL 6700 TUNNEL CAGE WASHER

Direct Fired Heater Model AD Specification

InterSeptor Centrifugal Separators Operating & Maintenance Manual

Bulletin FH05 FUME EXHAUST

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Reliable, Compact Systems with Complete Flexibility in Customization and Design

Dual Tower Heat Reactivated Desiccant Air Dryer

DOWNDRAFT BENCH SERIES

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Air Quality Control System

SECTION AIR COMPRESSORS AND ACCESSORIES

SECTION AIR HANDLING UNIT

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Moisture Separator.

Closed Circuit Cooling Towers

T F E

1.1 This section applies to air handling units for HVAC Systems.

Indirect Gas-Fired Make-Up Air

GIRTON CABINET WASHER MODEL 794A

SECTION (15833) - HVAC POWER VENTILATORS

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

BASIL 6000 TUNNEL CAGE WASHER

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Acrison. Polymair. Model 500 Polyelectrolyte Preparation System. For Dry and Liquid Polymers. Industrial and municipal chemical feed equipment.

Modular Supply Make-Up Air Unit

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

TECHNICAL. Series 18. Pump Packages

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Lenntech. Tel Fax

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Clean. Easy. COMPLIANT.

First Revision No. 15-NFPA [ Chapter 2 ]

Screw Compressors SM SERIES. Capacities from: 16 to 54 cfm Pressures from: 80 to 217 psig

QuadraFlow Cooling Tower

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

Type N RotoClone. Hydrostatic Precipitator. Better Air is Our Business

DIVISION 15 MECHANICAL

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

CPVS PRODUCT DESCRIPTION

Installation, Operation and Maintenance Manual

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

IC-45AV Vertical Clean Centrifuge

SECTION DOMESTIC WATER HEATERS

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

Supplying Clean Air to Industry

Our energy efficient experts and engineers have made ground breaking innovations in this field.

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

Direct Gas-Fired Make-Up Air

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

Sterilizer Model LS2020 Series Beta Star Life Science Products of R-V Industries

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

Transcription:

FAN SEPARATOR Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream. FAN / SEPARATOR SPECIFICATIONS Various materials of construction may be used to resist corrosive contaminants and scrubbing liquor that come into contact with the unit. Tri-Mer Corporation holds the U.S. Patent #3,616,604 for and has been manufacturing Fan/ Separator Units since 1966. Our Fan/Separator Units can be fabricated from PVC, Polypropylene, Fiberglass Overlayed PVC, 316 Stainless Steel, 304 Stainless Steel and Mild Steel. All units are Factory Tested. Units are available from 50 to 100,000 cfm. Every Fan / Separator unit is constructed of the most state of the art fabrication techniques using fusion, extrusion welding, and seamless corners wherever possible. Bolted access doors are provided for inspection of the interior and removal of the filter elements. Gasket made from closed cell PVC foam is provided. Hardware is 316 S.S. maximum bolt torque 10#. OPERATING CONFIGURATION The scrubbing liquor wets the contaminant as it enters the fan and allows it to be centrifugally spun out on the fan scroll through a process on dynamic mixing. The centrifugal action, using the fan wheel as part of the scrubbing process, will eliminate approximately 55 percent of all contaminants in the air stream. Scrubber to be of two-stage design with dynamic scrubbing as the first stage and the second stage to be an impingement process. The impingement process causes the air to change direction as it passes across the rigid packing media. The packing media also acts as a mist eliminator section. The packing media is supplied in framed packs and is suitable for 99 percent removal efficiency of 20 micron and larger water droplets under continuous a duty load. The scrubber contains a Venturi evacuation drain for continuous removal of scrubbing liquor. The Fan / Separator is a dry sump system and will contain only residual liquid passing through the scrubber during any phase of operation.

1) INTENT This Specification defines the design requirements, the quality and types of workmanship and materials, and the performance standards and guarantees for equipment, materials and services supplied by Tri-Mer Corporation. 2) SCOPE The vendor (Tri-Mer Corporation) shall furnish Fan / Separator Units complete with auxiliaries and options described herein. Each system shall include but is not limited to the following: The Fan Separator and internals necessary to provide adequate liquid-process stream contact in order to achieve performance. Mist eliminator to achieve entrained liquid separation. Flanged connections for all external water fill, water makeup and drain piping as required and optioned. Controls if optioned, to automatically feed water, and monitor pressure. Complete shop coating of required areas with Epoxy or other resistant paint for external surfaces.

3) SEPARATOR DESIGN REQUIREMENTS Fan / Separator Units shall be of low energy type. Internals shall be designed to prevent the buildup of solids. Fan / Separator Units shall be manufactured of PVC, Polypropylene, Stainless steel or Mild steel. Vendor shall evaluate materials and select the most appropriate material for this service. Scrubber to be complete with Fan and Separator section designed and manufactured together as an integral-operating machine. Separator Section shall be provided with clear view-ports designed for accessibility and inspection of equipment during operational phase. Inspection ports shall be placed in proper positions to facilitate the ease of operation and inspection. Flanged pipe connections shall be provided for the introduction of water as well as drainage. Contaminants shall enter the eye of the fan where they are treated with a fog mist of scrubbing liquor. The fan and motor shall be designed for a static pressure capability of the specified pressure drop through the Fan / Separator plus external pressures for the customers ductwork losses. The sound levels generated by the Vendor furnished equipment during normal operation shall not exceed 85 dba-weighted, slow response, under free field condition, at a horizontal distance of 10 feet from the surface of sound generation. Vendor shall provide electric motor and drives for each unit. Vendor shall be responsible for the selection of the motor characteristics and the motor mounting. All electrical equipment provided by the vendor shall be supplied in NEMA rated enclosures. All equipment manufactured by Tri-Mer Corporation is warranted under the standard Tri-Mer Corporation one-year warranty. All purchased components are warranted under the respective manufacturer warranty. 4) STANDARD SUPPLIED COMPONENTS Standard Purchased components furnished on the Tri-Mer Corporation Whirl/Wet Dust Collectors are as follows: Dwyer Magnehelic differential pressure gage for monitoring pressure across filter pack. ASCO or equal electrically actuated solenoid valve for inlet spray. Schedule 80 PVC plumbing. Hayward or equal valves. Vinyl tubing with traps for differential pressure connections. Fan section with standard EPACT 460/3/60 TEFC Motor. 5) COMPONENTS SUPPLIED BY END USER Tie downs, guy wires, anchor bolts and foundations. Field assembly. Field wiring.

Fresh water and drain piping to supplied 150# flanges. Mating flanges to customer connections, hardware and gaskets. Connecting duct from process. (See Options). Heat tracing and insulation. 6) OPTIONS Electrical Control Panel: An electrical control panel with NEMA rated enclosure and fused main disconnect switch. Designed for 460 volt / 3-phase - 60 hertz electrical supply. Internal components of the control panel are pre-wired and terminal blocks are provided for connection of external control components to be done by contractor. A motor starter to operate the exhaust fan with pushbutton controls mounted on the front of the enclosure. Power lines to the motor must be furnished and installed by the installation contractor. Electrical devices are designed and built in accordance with the National Electric Code (NEC). No other codes, standards, or specifications are followed unless a specific agreement has been obtained in writing. Duct: Tri-Mer Corporation offers design and manufacture of duct systems in PVC, Polypropylene and FRP. Re-circulation Tank: A remote tank with level control and pump, provided for circulation of scrubbing liquor. ph Control System: Control of re-circulation tank ph level. ph Control System consists of ph probe, Controller, and electric or pneumatic metering pump. PLC Interface: A programmable logic controller (PLC) shall mediate control of system functions. The programmable controller shall be mounted within the control panel enclosure. The programmable Logic Controller (PLC) shall be Allen Bradley or equal.