DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

Similar documents
Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method.

Fire Test Methods ASTM NFPA UL ISO IEC

Market-Leading Non-Metallic Enclosure Brands

Cleanroom Materials Flammability Test Protocol

Smoke detection in hazardous areas:

SECURITY BLANKET Foam Fire Protection Products

Flexible Heaters. of Silicone Rubber & Kapton

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Time-Tested Fiberglass

DNVGL-CP-0399 Edition March 2016

Test Report: ICL/H18/9039 Rev 1

CHOOSING CORE MATERIALS FOR AEROSPACE APPLICATIONS

Fire Retardant Resins PERFORMANCE THAT TAKES THE HEAT

First Revision No. 6-NFPA [ Section No. 2.2 ]

Appendix: Standards and Specifications for Evaluation of Thermal Management in Electronic Industry

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Fundamentals of Insulation and their effect on buidling sustainability

DNVGL-CP-0401 Edition February 2016

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Flame Retardant Polyethylene Tubing

Pneumatic Tubing POLYTUBING O.D. 5/32"

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Fire Performance of Translucent Systems

FM Approval Standard For Cavity Walls And Rainscreens

Nuclear Power Plant LSZH Cable Overview

fire resistant cables

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

Determination of Fire Exposure Heat Flux in Cable Fire Tests

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

The Importance of Flame Retardant. Jackson Liu, 3M Taiwan

Laboratory Safety Audit

THERMOPLASTIC - NYLON FLAT WASHERS AND SPACERS

Identifying and Preventing Dust Fire and Explosion Hazards

In Search of Standard Reference Materials (SRMs) for ASTM E05 Fire Standards by. Norman Alvares & Harry Hasegawa

Disaster Response Can Composites Prevent This? Construction, Corrosion, & Infrastructure Conference April


NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX

SECTION DUCTWORK

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

Differences Among Screw Plug Immersion Heaters

FUNDERMAX GMBH FIRE TEST REPORT

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

For inspection purposes only.

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FR Veil Provides Low Cost Model to Achieve ASTM E-84 Class A Smoke Index

Public Comment No. 1-NFPA [ Section No ]

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

Building Description Applicable Codes & Standards Prescriptive Requirements. Performance Based Design

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

Model IVSI Positive Pressure Venting Systems

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Ceramic Fiber Heaters

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

FRANCE M & F RANKING ACCORDING TO NF F

Section Specification for Geotextile Used in Permanent Erosion Control Application

Coil Heaters. Design Features: Typical Applications: Coil Heaters

A Study on Safety by Risk Assessment of Clean Room

SEMICONDUCTOR FABRICATION FACILITIES

Significant Changes to the 2012 IFC Semiconductor Fabrication Facilities. Scott Stookey Senior Technical Staff International Code Council, Austin TX

7.1 Smoke Detector Performance

DUCTING & VACUUM HOSE

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

IRceL CH4 Methane (CH 4

PART 2. Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

DNVGL-CP-0402 Edition February 2016

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

Tri-Mer Packed Bed Tower Scrubbers

Steel Casework Acid Storage

Üntel is ready for CPR

OIL AND GAS INDUSTRY

COMPOSITE CHIMNEYS. Géza Kecskeméthy, István Kovácsay, [Balázs Zsigmond]: Kompozitor Co. Ltd., Hungary

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

Custom-designed and standard Multiconductor (Multicore) Cables

Protective & Marine Coatings Europe, Middle East, Africa & India

Enviro International Corporation. WET SCRUBBER

Report on Public Input June 2014 NFPA 101

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

SEMICONDUCTOR FABRICATION FACILITIES

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Circulation Heaters Selection Guidelines

Standard Compared 2012 Changes of the International Building Code and National Fire Protection Association- 101

Transcription:

DG TM DualGuard 2000 Fluoropolymer Barrier FRP Duct C U L LISTED US Fluoropolymer Barrier FRP Duct Composites USA A Critical Process Systems Group Company

Worried about meeting Insurance Underwriter and Building Code Requirements for corrosive fume exhaust? DG TM DualGuard 2000 Fluoropolymer Barrier FRP Duct C US Your worries are over! Insurance underwriters and local building codes routinely require the use of low smoke, fire safe materials in the construction of process facilities. DualGuard 2000 meets these requirements without the use of either internal or external sprinklers making it less expensive to install. Building Codes in the United States, Canada, and many other locations around the globe, including those of B.O.C.A. and the U.B.C./I.B.C. require testing to ASTM E-84 for flame spread and smoke development. Duct must exhibit a flame spread of or less and a smoke development of 50 or less on both the inside and the outside of the duct to be used without sprinklers. DualGuard 2000 has been tested by both Factory Mutual and Underwriters Laboratories. Its flame spread of 5 and smoke development of 10, on both the inside and outside of the duct, assures you that a DualGuard system will meet building codes and insurance requirements. Optical Density 500 400 300 200 100 2 U L LISTED 6 10 14 18 22 Time (Minutes) Epoxy Polyester DualGuard ASTM E-84 Smoke Density Generation Flame Spread of 5 on both the inside and outside of the duct (ASTM E-84) Smoke Development of 10 on both the inside and outside of the duct (ASTM E-84) VeilGuard in the corrosion liner for premium corrosion resistance Built to long established industry guidelines for corrosion resistant fiberglass composites Easy to assemble with a variety of joining techniques Independent 3rd party QA auditing by Factory Mutual and U.L. Factory Mutual Approvals DualGuard 2000 passed Factory Mutual's new, tougher 4922 test procedure for non-sprinkler fume and smoke removal systems - File no. 4B1A5M.AM. DualGuard 2000 passed Factory Mutual's new 4910 test procedure for Clean Room Approved Materials - File No. 3006453. Underwriters Laboratories Listing DualGuard 2000 passed U.L. 181 test procedure, leading to its listing as a Class 1 Duct in accordance with U.L. requirements - File No. MH26567.

You'll share our passion: fire safe and easy to install! Shown below is an example of an engineered solution from Composites USA with DualGuard 2000, a reducing cross with integral dampers. DualGuard 2000 takes the heat when exposed to a direct flame source and will continue to exhaust hazardous chemical process fumes during a fire. DualGuard does not require collapsing sleeves or dampers which would prevent hazardous smoke removal. DualGuard will not generate toxic gases that can endanger employees. The advantages of the DualGuard resin system include corrosion resistance, high temperature resistance, does not readily burn, gives off low smoke, and has low smoke toxicity. DualGuard 2000 duct and dampers are available in almost every conceivable configuration with sizes as small as 1/2 inch and as large as 24 feet in diameter. Fittings include elbows, transitions, tees, reducers, stacks, fume hoods, dampers and more. See our product catalog or visit our web site for a complete product listing. Engineered with confidence - chemical, mechanical and professional engineers on staff. Manufactured with state of the art filament winding, layup, thermoform and resin transfer molding processes. Quality guaranteed with independent audits by Factory Mutual, U.L. and U.S. Government to Mil Spec 45208. DualGuard Meets the Construction Standards for Corrosive Fume Fiberglass Duct! Dual Guard is built to the same standards that have guided the fiberglass corrosion industry for over thirty years. 1. 2. 3. 4. Inner Surfacing Layer - Fluoropolymer surfacing veil resulting in a mil (0.63mm / 0.0 inch) thick reinforced resin-rich surface. Not all FM ducts provide a corrosion veil; none use a premium veil. Interior Layer - reinforced with non-continuous glass strands at 20% - 30% by weight, having fiber lengths from 0.5-2.0 inches. Structural Layer - continuously wound fiberglass to provide optimal strength for a given application. This layer is typically 65% by weight glass. External Layer - woven fiberglass cloth for ease of bonding using either conventional fiberglass joining techniques or proprietary Composites USA bonding systems. 1 2 3 4

FM and U.L. Test Results that will exceed your expectations! Factory Mutual / U.L. Test Criteria Flame Spread Inside Flame Spread Outside Smoke Development Inside Smoke Development Outside Fire Propagation Index (FPI) Smoke Damage Index (FPI) DualGuard 2000 5 5 10 10 1.8 0.04 FM Limits (Max.) n.a. 50 6.0 0.40 U.L. Limits (Max.) 50 50 n.a. n.a About U.L. Testing - U.L. testing involves destructive product tests for flame and smoke generation, strength - pressure, vacuum, tension, bending - impact and puncture resistance, erosion and a number of other criteria including long term stability at low and elevated temperature. In addition to assuring the product will not burn, U.L. Listing assures the customer that the product provided is built to provide years of service in rugged industrial environments. About FM Test Protocols - Factory Mutual has long tested products for flame propagation and smoke generation. Duct products that successfully pass these critical battery of tests are given FM Approval to their 4922 protocol, which allows corrosive fume and smoke exhaust duct to be installed without sprinklers. The key tests for FM 4922: 1. 2. 3. 4. 5. The ASTM E-84 tunnel test, measuring flame spread and smoke generation in a controlled burn chamber. 50 kw-scale FMRC Flammability Apparatus Test to measure the Critical Heat Flux (CHF - a heat flux at which ignition is not expected to occur) and the Thermal Response Parameter (TRP - a measure of ignition resistivity), as well as the ignition and peak Chemical Heat Release Rate (CHRR). The oxygen bomb calorimeter (for heat content) in accordance with D 240-85. Auto-ignition in accordance with ASTM D 1929-77. The Factory Mutual horizontal / vertical burn test which measures flame propagation, temperature rise and strength retention during actual duct fires at temperature over 1000 F. Shown here is a view of the configuration for the FM 4922 horizontal test, with a heptane-fed fire exhausted through 24 feet of duct. Temperatures can reach 1500 F during the minute two stage test. Key criteria include flame and smoke generation, maintenance of structural integrity and limits of the duct temperature rise. Factory Mutual also has a Clean Room Materials Test Protocol, 4910 - The 4910 protocol builds upon the results of the 4922 testing with additional samples and testing to insure suitability for Clean Room product installations. The 4910 test evaluates materials' fire propagation behavior, potential for smoke contamination, and potential for contamination by corrosive products of combustion. The key tests for FM 4910: 1. 2. 3. Ignition tests, during which samples are exposed to increasing heat flux levels up to 60 kw/m2, are used to calculate the thermal response parameter (TRP). Fire propagation tests, in which samples are burned in the presence of 40% oxygen, help generate the fire propagation index (FPI). Combustion tests, similar in nature to the fire propagation tests, run at 21% oxygen are used to generate smoke index (SI) numbers. From the above tests, Factory Mutual calculates a Smoke Damage Index (SDI) which is the total mass of smoke generated to the total mass of the material loss. The 4910 upper limit for the SDI is 0.40. FPI values are used for classification of materials as either non propagating (good) or propagating. The 4910 upper limit for the FPI is 6.0. 24 ft of test duct Exhaust Fan Flame Enclosure 2 1 ft surface of heptane generates 10,000 BTU/minute of heat

Corrosion Resistance that will exceed your needs! VeilGuard is one of the most chemically resistant polymers available today. In addition to its chemical resistance, with a U.L. 94 V-0 rating, VeilGuard also has the advantages of low flammability and low smoke generation. It is resistant to chemical attack from most acids, bases and solvents, has excellent temperature resistance, and better barrier properties than PTFE or FEP. Use of this material in the corrosion liner for DualGuard 2000 series products offers significant advantages compared to systems with glass, polyester or no liner reinforcement. Comparison of Corrosion Liner Veils VEIL MATERIAL FLAME SPREAD SMOKE GENERATION HF or CAUSTIC ATTACK Fiberglass C-veil or MatFM No Burning No Smoking >1000 C Attacked Polyester veil (Nexus) Burns Readily Heavy Smoke 0 C VeilGuard Fluoropolymer No Smoke U.L. 444 Pass 240 C SERIES 2000 Copolymer Resin The resin used in the DualGuard 2000 system offers excellent corrosion resistance in and of itself. And as noted above, the VeilGuard veil used in DualGuard 2000 products offers better corrosion resistance than any other competing veil. Used together, DualGuard 2000 offers an unbeatable combination of properties. The resin system used in DualGuard 2000 is a proprietary copolymer product developed specifically for enhanced corrosion resistance, low flame propagation and low smoke development in pipe and duct applications. In addition to its superior fire performance, very low smoke evolution, and higher temperature performance, Series 2000 resin offers excellent corrosion resistance to a wide variety of acids, solvents and bases. Specifically, this applies to the types of vapors typically found in exhaust streams from laboratory, semiconductor, plating and pharmaceutical operations. Tests of DualGuard resin demonstrated fatigue strengths (cycles to failure) equivalent to epoxy pipe, and better fatigue strength than vinyl ester. ASTM C-581 test results are shown for DualGuard 2000 exposed to a variety of reagents. These measurements reflect flex modulus and strength retention following full liquid immersion for one year - a service much more severe than a duct installation where exposures are typically diluted vapors. As can be seen from the charts, DualGuard 2000 compares very favorably against fire retardant vinyl ester in a variety of exposure conditions. DualGuard 2000 vs FR Vinyl Ester Corrosion Resistance Comparison Full Liquid Immersion 12 Months Dual Guard 15% Hydrocloric Acid Strength 15% Hydrocloric Acid Modulus 15% Nitric Acid Strength 15% Nitric Acid Modulus Alcohol Strength Alcohol Modulus H 2SO 4 10% HCL 15% HNO 3 5% HF 1% NaCIO 3 5.% D.I. Water Caustic ph 10 % Retention Physical Properties 0 20 40 60 80 100 120 140 DualGuard 2000 Corrosion Resistance Full Liquid Immersion 12 Months Flex Strength Flex Modulus % Retention Physical Properties 0 20 40 60 80 100 120 140 Chloroform % Methanol 5%

Other Composites USA products: Dual Laminate Equipment & Structures - Corrstop Specialized Composite Plastic Equipment - FlameGuard Fiberglass Scrubbers & Skid Systems Fiberglass Tanks & Vessels Fiberglass Stacks Services Consulting Design Manufacturing Construction Inspection/Testing For more information visit our website at: www.compositesusa.com Composites USA A Critical Process Systems Group Company Manufactured in the USA solutions critical process Innovative for all your systems We also invite you to explore the countless invaluable resources offered by the CPS Group family of companies listed below: Critical Process Systems Group BioPharm Engineered Systems Composites USA CPS Process Solutions Diversified Fluid Solutions ENGVT, LLC Fab-Tech Inc. NEHP Inc. www.cpsgrp.com www.bpesys.com www.compositesusa.com www.cpsprocess.com www.dfsolution.com www.engvt.com www.fabtechinc.com www.nehp.com Technical information contained in this document is subject to change without notice. COPYRIGHT 2015 COMPOSITES USA