CASEMENT AIR CONDITIONER USER S MANUAL MODEL: SIN-TC1 1
FOREWORD Casement air-conditioners are pieces of high value. In order to ensure your lawful rights and interests, please have the professional technicians to do the installation for you. This instruction manual is the universal-purpose version for the units that you purchase might be slightly different from the ones described in the manual, but it does not affect your proper operations and usage. Please read carefully the sections corresponding to the specific model you choose, and keep the manual properly so as to facilitate your reference at later time. Attention: (1) The appliance is not intended for using by young children or infirm persons without supervision. (2) Young children should be supervised to ensure that they do not play with the appliance. (3) The plug shall be accessible after install the appliance. (4) The appliance shall be installed in accordance with national wiring regulation. (5) The appliance can t be installed in laundry. (6) If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 2
CASEMENT AIR-CONDITIONER This casement air-conditioner is a small size appliance, which can adjust the temperature and humidity in a room. Its flexibility characteristics make it easily used on different occasions in different rooms. It also has multiple functions, including cooling, dehumidifying and fanning ventilation. This unit was designed especially to be used in a family house, office, etc. It has a compact design compared to others with the same cooling capacity. Power consumption is low and the noise especially low. Features of heating operation: the machine heating operation, the principle is that the air is heating by the heating pump before sent out. The function is not affected by ambient temperature. Features of cooling operation: Other air conditioning patterns are recommended when the indoor temperature is either below 17 0 C(63 0 F) or above 35 0 C(95 0 F). ATTENTION Before you use your casement air-conditioner, please read this instruction manual carefully so that you get the best from the unit. This instruction manual is used for guidance and does not form part of a contract. We reserve the right to make technical changes without prior notice. 3
PRECAUTION ON INSTALLATIONS Please install the unit 75-150cm above the ground. The intake and discharge vents unit should not be obstructed. The unit be plugged into its own individual outlet that has a voltage rating suitable for normal operation (220V-240V) The unit should not be directly exposed to sunlight or rain. 220-240VAC? The fixing between the mounting kit and window should be secured. The six screws shown below must be well fixed. 1
PARTS IDENTIFICATION OPERATION 2
INSTRUCTION AIR CONDITIONER CONTROLS 1 POWER Press this button for three seconds,the unit will be turned on,and press this button for three seconds again,the unit will be turned off. When the unit running, press this button, you can choose one of the operation modes: AUTO, COOL, DEHUMIDIFYING and FAN. 2 Temperature set control Use for adjusting the temperature. 3
The default display on control panel is setting temperature. When + or - key is pressed, the set temperature is displayed and may be adjusted. OPERATION AND INDICTION SECTIONS OF REMOTE CONTROLLER 1. POWER 2. MODE 3. TIMER 4. SPEED 5. TEMP+ 6. TEMP- 7. SLEEP On/Off switch MODE selector Hourly programming Fan speed selector Temperature selector up Temperature selector down Night operation selector 4
USE OF CONTROL PANEL POWER SOURCE The AC socket must be firm and reliable. Don t connect the casement air-conditioner to a multiply socket outlet which is also being used for other electrical appliances. Inset the AC power plug securely into the AC socket using the unit, when it beeps after two seconds, press ON/OFF button, the unit begins to run. AUTO OPERATION 1. Repeatedly press MODE button to choose the AUTO mode, The AUTO mode LED light and corresponding operation mode light will light up. 2. The product will deliver cooled air when room temperature is above 26 0 C. 3. The product will operate in DRY MODE when room temperature is above 23 0 C to 26 0 C. 4. The product will simply circulate room temperature air when room temperature is 23 0 C or below 5. Press SPEED button to choose a proper fan speed, high, middle, low speed. COOLING OPERATION 1. Repeatedly press MODE button to choose the cooling mode, The COOL mode LED light will light up. 2. Repeatedly press TEMP+ or TEMP- button to set a proper room TEMP. at 16 0 C-31 0 C. 3. Press SPEED button to choose a proper fan speed, high, middle, low speed. NOTE: In order to improve the cooling efficiency, be careful that: a) If your room is directly exposed to the sun, draw the curtains please. b) Do no place near other heat source. DEHUMIDIFYING OPERATION 1. Keep the windows and the doors closed to aid in effectively dehumidifying the room. 2. Repeatedly press the MODE button to choose the dehumidifying mode, The DEHUM mode LED light will light up., the fan speed cannot be adjusted. FAN OPERATION 1. Repeatedly press the MODE button, select the heat mode. The FAN mode LED light will light up.. 2. Press SPEED button to choose the fan speed: high-middle-low. TIME SET FUNCTION To set time to start the machine with the unit off (but power supplied), press TIMER button, the LCD window will show OFF, press the TIME button, set the time to start as you like. The setting range is 1-12 hours. If have set switch on/off after 12 hours, press this key again there could cancel the timing. 5
OPERATION PROCEDURES ELECTRICAL CIRCUIT OPERATION FO DEHUMIDIFICATION 1.Press the ON/OFF button. 2.Press the Function button to select the DRY for dehumidification function 3.Press the ON/OFF key again if you wish to stop. 1 25 20 RH 90% RH 80% RH 70% 85 65 DBT line DBT lin e RH li ne 24 16 L/ d ay 15 10 RH 60% (RH) % 45 40 RH line DBT ( ) 5 5 20 24 27 30 (DB ) 1 hr 2 hr 3 hr 4 hr * qua ntity of dehumidification for unit operating * at 24-85% for room area of 16.2m 2 INSTALLTION INSTRUCTIONS Casement air-conditioners are pieces of high value. In order to ensure your lawful rights and interests, please have the professional technicians to do the installation for you. Width: 390mm Height: 840~1370mm Indoors Outdoors MAIN STEPS OF INSTALLATION Unit can be installed on the left or right side of a sliding window. 6
1. Fix the mounting Kit securely 2.Insert the unit on the bottom of kit. in the window. the mounting 7
3. Push the unit forward and screw the Body-Angle (upper) with the mounting Kit. 8
LIST O F THE INSTALLING COMPO NENTS 1 2 3 4 5 6 7 8 No. 1 2 3 4 5 6 7 8 Name of components Mounting kit Insulating material (hard) Insulating material (soft) Pad Sub fixture stopper Seal Screw E4 20 E4 10 E4 12 Piece 1 4 4 2 2 1 1 6 10 2 9
Attaching the Window Panel Material: Fill the gaps between the installing frame and the window post to prevent water leaking indoors Fixing the Mounting Kit: A. To be fixed on the Aluminum Door & Window. 1. Place the mounting kit (lower) on the flange of the aluminum door & window. Push upward and rightward to get close to the window post. 2. Fix the mounting kit (upper & lower) tightly with screws. 3.fix the mounting kit securely with the aluminum window. door & 10
B. Fixing on the wooden window. 1. Put the sub fixtures on the wooden window frame (up and down), and fix them tightly with screws. The up and down fixtures should be at the same vertical position. 2. Place the mounting kit on the sub fixtures. 3. Tighten the screws at both sides after mounting. 4. Fix the mounting kit and fixtures tightly with screws. 11
SPECIAL ATTENTION Must turn OFF the air conditioner first before unplugging. Must insert the plug properly into the wall outlet. DO NOT OPERATE IN THE FOLLOWING STATES Room temperature is below21. Outside temperature is up to 43.(The protective device will stop the air conditioner.) Wait 3 minutes for restarting the air conditioner. MAINTENANCE Before cleaning the air-conditioner, always turn off and disconnect the power supply. 1. Air filter cleaning 12
2. *Remove the filter by pulling it out as shown below. *Wash the filter once every 1-2weeks to maximize the performance of the air conditioner and to keep the air flowing freely. *Use water (under 40 ) or soft cleaning agents to soft the filter (Let it dry first before putting it back.) *Do not use volatile substances such as gasoline, toluene or diluents to clean the filter. 3. Cabinet & Front Panel Cleaning Wipe the cabinet and front panel regularly. Do not use spraying type insecticide directly on the unit. Do not use volatile substances such as gasoline, toluene or diluents to clean the cabinet and front panel. Do not wash the unit directly with running water. 13
BEFORE CALLING FOR SERVICE 1. Air conditioner does not start Whether the power supply plug is loosened or disconnected? Is the fuse blown or circuit breaker tripped? Is the power source correct? 2.Air conditioner does not cool as it should. 14
3. The following conditions are not normal for the product: When the surrounding humidity is at 80% or above, condensation may occur after prolonged operation. In addition, some dripping may occur. Slight of fluid flowing is normal, it is due to coolant flowing in the system. IMPORTANT WARNINGS if the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Repair or replace immediately all electric cords that have become frayed or otherwise damaged. The unit shall be installed in accordance with the national wiring regulations. In high humidity (over 80%) conditions, the unit may experience some splashing of water droplets at the condenser side. The maximum and minimum operating temperature of the hot and cold sides. Indoor: Dry bulb : 21 to 32 Wet bulb : 16 to 23 Outdoor: Dry bulb: 24 to 43 Wet bulb: 21 to 26 Remark: In the interest of product improvement,the specifications may be change without prior notice. All features and specifications are all given by manufacture. 15