CASEMENT AIR CONDITIONER USER S MANUAL MODEL: SIN-TC1

Similar documents
Moveable Air-conditioner User s Manual

INDOOR UNIT/OUTDOOR UNIT

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Portable Air-conditioner Use and Care Manual

SPLIT TYPE. Instruction manual

Dual-Hose Portable Air Conditioner User Manual

USER MANUAL TPS-M5/M55/M555

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Operating Instructions Air Conditioner

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

MODEL: DC10RCDH / DC12RCDH

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

INDOOR UNIT/OUTDOOR UNIT

Portable Air-conditioner

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT

Reverse Cycle Split System Air Conditioner

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

Reverse Cycle Portable Air Conditioner with Dehumidifier

AC-12200E Portable Air Conditioner

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Outdoor Beverage Center

5) Do not start or stop the unit by inserting or pulling out the power plug.

Instruction Manual. Model: EPA 16 Portable Airconditioner

Local air conditioner

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Portable Air Conditioner

DEHUMIDIFIER USER MANUAL 95 PINT FOR MODEL: 3PAD95. Quick Start Tips on Page 1 COMFORT...BUILT TO LAST

PC20-AMFII / PC40-AMF USER MANUAL

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

PORTABLE AIR CONDITIONER

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT

Inverter Split-type Room Air Conditioner

IONIZER SS225 SS225. ionizer anti-mite

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

INDOOR UNIT/OUTDOOR UNIT

Using the Remote Control Unit

Owner s Manual Super-Slim Four-Way Cassette

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

WINDOW / WALL-TYPE ROOM AIR CONDITIONER

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

PORTABLE AIR CONDITIONER

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Mobile Type AIR CONDITIONERS (LOCAL AIR CONDITIONERS)

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

REMOTE CONTROL MANUAL

Portable Air Conditioner. Instruction Manual

INDOOR UNIT/OUTDOOR UNIT

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

15,000 BTU Portable Air Conditioner

Instruction Manual. Portable Air Conditioner

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

LG Cassette Multi Type Air Conditioner

FLOOR-STANDING TYPE AIR CONDITIONER USER'S MANUAL

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

INSTRUCTION MANUAL COMPRESSOR DRIVEN WINE COOLER

WA-1240E: 12,000 BTU Cooling only WA-1240H: 12,000 BTU Cooling and Heating WA-1420E: 14,000 BTU Cooling only WA-1420H: 14,000 BTU Cooling and Heating

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

OWNER S MANUAL VMH 09/12/18/24

USER MANUAL. Vino 160 Vino 440. Wine Coolers

ENGLISH REMOTE CONTROL MANUAL

EURO APPLIANCES BY EUROSTYLE GROUP

PORTABLE AIR CONDITIONER OWNER S MANUAL

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

PORTABLE AIR CONDITIONER

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

PORTABLE AIR CONDITIONER


53 KNL / 53 QNL OWNER S MANUAL

PORTABLE AIR CONDITIONER (LOCAL)

Owner's Manual TABLE OF CONTENTS

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

LG Convertible-Type Air Conditioner

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

INDOOR UNIT/OUTDOOR UNIT

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

PORTABLE AIR CONDITIONER (LOCAL)

Whynter Portable Ice Maker 33 lb capacity - White

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Operating Instructions

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

Owner's Manual TABLE OF CONTENTS

Dehumidifier. User Manual

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

OWNER S MANUAL OIL FILLED HEATER MODEL:NY-13A1L READ AND SAVE THESE INSTRUCTIONS

Transcription:

CASEMENT AIR CONDITIONER USER S MANUAL MODEL: SIN-TC1 1

FOREWORD Casement air-conditioners are pieces of high value. In order to ensure your lawful rights and interests, please have the professional technicians to do the installation for you. This instruction manual is the universal-purpose version for the units that you purchase might be slightly different from the ones described in the manual, but it does not affect your proper operations and usage. Please read carefully the sections corresponding to the specific model you choose, and keep the manual properly so as to facilitate your reference at later time. Attention: (1) The appliance is not intended for using by young children or infirm persons without supervision. (2) Young children should be supervised to ensure that they do not play with the appliance. (3) The plug shall be accessible after install the appliance. (4) The appliance shall be installed in accordance with national wiring regulation. (5) The appliance can t be installed in laundry. (6) If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 2

CASEMENT AIR-CONDITIONER This casement air-conditioner is a small size appliance, which can adjust the temperature and humidity in a room. Its flexibility characteristics make it easily used on different occasions in different rooms. It also has multiple functions, including cooling, dehumidifying and fanning ventilation. This unit was designed especially to be used in a family house, office, etc. It has a compact design compared to others with the same cooling capacity. Power consumption is low and the noise especially low. Features of heating operation: the machine heating operation, the principle is that the air is heating by the heating pump before sent out. The function is not affected by ambient temperature. Features of cooling operation: Other air conditioning patterns are recommended when the indoor temperature is either below 17 0 C(63 0 F) or above 35 0 C(95 0 F). ATTENTION Before you use your casement air-conditioner, please read this instruction manual carefully so that you get the best from the unit. This instruction manual is used for guidance and does not form part of a contract. We reserve the right to make technical changes without prior notice. 3

PRECAUTION ON INSTALLATIONS Please install the unit 75-150cm above the ground. The intake and discharge vents unit should not be obstructed. The unit be plugged into its own individual outlet that has a voltage rating suitable for normal operation (220V-240V) The unit should not be directly exposed to sunlight or rain. 220-240VAC? The fixing between the mounting kit and window should be secured. The six screws shown below must be well fixed. 1

PARTS IDENTIFICATION OPERATION 2

INSTRUCTION AIR CONDITIONER CONTROLS 1 POWER Press this button for three seconds,the unit will be turned on,and press this button for three seconds again,the unit will be turned off. When the unit running, press this button, you can choose one of the operation modes: AUTO, COOL, DEHUMIDIFYING and FAN. 2 Temperature set control Use for adjusting the temperature. 3

The default display on control panel is setting temperature. When + or - key is pressed, the set temperature is displayed and may be adjusted. OPERATION AND INDICTION SECTIONS OF REMOTE CONTROLLER 1. POWER 2. MODE 3. TIMER 4. SPEED 5. TEMP+ 6. TEMP- 7. SLEEP On/Off switch MODE selector Hourly programming Fan speed selector Temperature selector up Temperature selector down Night operation selector 4

USE OF CONTROL PANEL POWER SOURCE The AC socket must be firm and reliable. Don t connect the casement air-conditioner to a multiply socket outlet which is also being used for other electrical appliances. Inset the AC power plug securely into the AC socket using the unit, when it beeps after two seconds, press ON/OFF button, the unit begins to run. AUTO OPERATION 1. Repeatedly press MODE button to choose the AUTO mode, The AUTO mode LED light and corresponding operation mode light will light up. 2. The product will deliver cooled air when room temperature is above 26 0 C. 3. The product will operate in DRY MODE when room temperature is above 23 0 C to 26 0 C. 4. The product will simply circulate room temperature air when room temperature is 23 0 C or below 5. Press SPEED button to choose a proper fan speed, high, middle, low speed. COOLING OPERATION 1. Repeatedly press MODE button to choose the cooling mode, The COOL mode LED light will light up. 2. Repeatedly press TEMP+ or TEMP- button to set a proper room TEMP. at 16 0 C-31 0 C. 3. Press SPEED button to choose a proper fan speed, high, middle, low speed. NOTE: In order to improve the cooling efficiency, be careful that: a) If your room is directly exposed to the sun, draw the curtains please. b) Do no place near other heat source. DEHUMIDIFYING OPERATION 1. Keep the windows and the doors closed to aid in effectively dehumidifying the room. 2. Repeatedly press the MODE button to choose the dehumidifying mode, The DEHUM mode LED light will light up., the fan speed cannot be adjusted. FAN OPERATION 1. Repeatedly press the MODE button, select the heat mode. The FAN mode LED light will light up.. 2. Press SPEED button to choose the fan speed: high-middle-low. TIME SET FUNCTION To set time to start the machine with the unit off (but power supplied), press TIMER button, the LCD window will show OFF, press the TIME button, set the time to start as you like. The setting range is 1-12 hours. If have set switch on/off after 12 hours, press this key again there could cancel the timing. 5

OPERATION PROCEDURES ELECTRICAL CIRCUIT OPERATION FO DEHUMIDIFICATION 1.Press the ON/OFF button. 2.Press the Function button to select the DRY for dehumidification function 3.Press the ON/OFF key again if you wish to stop. 1 25 20 RH 90% RH 80% RH 70% 85 65 DBT line DBT lin e RH li ne 24 16 L/ d ay 15 10 RH 60% (RH) % 45 40 RH line DBT ( ) 5 5 20 24 27 30 (DB ) 1 hr 2 hr 3 hr 4 hr * qua ntity of dehumidification for unit operating * at 24-85% for room area of 16.2m 2 INSTALLTION INSTRUCTIONS Casement air-conditioners are pieces of high value. In order to ensure your lawful rights and interests, please have the professional technicians to do the installation for you. Width: 390mm Height: 840~1370mm Indoors Outdoors MAIN STEPS OF INSTALLATION Unit can be installed on the left or right side of a sliding window. 6

1. Fix the mounting Kit securely 2.Insert the unit on the bottom of kit. in the window. the mounting 7

3. Push the unit forward and screw the Body-Angle (upper) with the mounting Kit. 8

LIST O F THE INSTALLING COMPO NENTS 1 2 3 4 5 6 7 8 No. 1 2 3 4 5 6 7 8 Name of components Mounting kit Insulating material (hard) Insulating material (soft) Pad Sub fixture stopper Seal Screw E4 20 E4 10 E4 12 Piece 1 4 4 2 2 1 1 6 10 2 9

Attaching the Window Panel Material: Fill the gaps between the installing frame and the window post to prevent water leaking indoors Fixing the Mounting Kit: A. To be fixed on the Aluminum Door & Window. 1. Place the mounting kit (lower) on the flange of the aluminum door & window. Push upward and rightward to get close to the window post. 2. Fix the mounting kit (upper & lower) tightly with screws. 3.fix the mounting kit securely with the aluminum window. door & 10

B. Fixing on the wooden window. 1. Put the sub fixtures on the wooden window frame (up and down), and fix them tightly with screws. The up and down fixtures should be at the same vertical position. 2. Place the mounting kit on the sub fixtures. 3. Tighten the screws at both sides after mounting. 4. Fix the mounting kit and fixtures tightly with screws. 11

SPECIAL ATTENTION Must turn OFF the air conditioner first before unplugging. Must insert the plug properly into the wall outlet. DO NOT OPERATE IN THE FOLLOWING STATES Room temperature is below21. Outside temperature is up to 43.(The protective device will stop the air conditioner.) Wait 3 minutes for restarting the air conditioner. MAINTENANCE Before cleaning the air-conditioner, always turn off and disconnect the power supply. 1. Air filter cleaning 12

2. *Remove the filter by pulling it out as shown below. *Wash the filter once every 1-2weeks to maximize the performance of the air conditioner and to keep the air flowing freely. *Use water (under 40 ) or soft cleaning agents to soft the filter (Let it dry first before putting it back.) *Do not use volatile substances such as gasoline, toluene or diluents to clean the filter. 3. Cabinet & Front Panel Cleaning Wipe the cabinet and front panel regularly. Do not use spraying type insecticide directly on the unit. Do not use volatile substances such as gasoline, toluene or diluents to clean the cabinet and front panel. Do not wash the unit directly with running water. 13

BEFORE CALLING FOR SERVICE 1. Air conditioner does not start Whether the power supply plug is loosened or disconnected? Is the fuse blown or circuit breaker tripped? Is the power source correct? 2.Air conditioner does not cool as it should. 14

3. The following conditions are not normal for the product: When the surrounding humidity is at 80% or above, condensation may occur after prolonged operation. In addition, some dripping may occur. Slight of fluid flowing is normal, it is due to coolant flowing in the system. IMPORTANT WARNINGS if the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Repair or replace immediately all electric cords that have become frayed or otherwise damaged. The unit shall be installed in accordance with the national wiring regulations. In high humidity (over 80%) conditions, the unit may experience some splashing of water droplets at the condenser side. The maximum and minimum operating temperature of the hot and cold sides. Indoor: Dry bulb : 21 to 32 Wet bulb : 16 to 23 Outdoor: Dry bulb: 24 to 43 Wet bulb: 21 to 26 Remark: In the interest of product improvement,the specifications may be change without prior notice. All features and specifications are all given by manufacture. 15