The new mains-operated ATMOS respiratory tract suction devices in the reliable 26 l and 16 l class Oversuctionproof and favourably priced reprocessing MedizinTechnik 265
MedizinTechnik Basic device Mains-operated devices l Basic device l Versions ATMOS C 261 Aspirator / DDS l Powerful for particularly viscous secretion l Triple overflow protection due to: - innovative filter technology - integrated overflow protection - Direct-Docking- System (DDS) l Infinitely variable vacuum adjustment and precision indication l Condensate trap for quick visual inspection whether device is oversucked l Secretion container autoclavable up to 1000 x l Sliding cover for protection of the control elements l For use on the ward, for nursing care and clinic Perfect synergy of performance, safety and favourable priced reprocessing! / DDS 313.0100.0 Portable secretion suction device, airflow rate of pump: 26 ± 2 l/min, vacuum: -78 kpa ± 2 kpa / -780 mbar ± 20 mbar / -585 mmhg ± 15 mmhg, infinitely variable vacuum adjustment and precision indication, grad. secretion container 1 l, lid for secretion container with triple oversuction safety by modern filter technology, integrated oversuction protection and DDS, 1 DDS bacterial filter, condensate trap, silicone suction hose Ø 6 mm, L = 1,30 m, fingertip, all hoses and parts of the secretion container are sterilisable up to 134 C, 2 m mains cable for 230 V~/50/60 Hz, dimensions (H x W x D): 250 x 255 x 180 mm / R 313.0101.0 Like / DDS, but with Receptal -container, support and / M 313.0102.0 Like / DDS, but with Medi-Vac container, support and REF We have been certified acc. to EN ISO 9001 and EN ISO 13485 0124 / DDS 313.0300.0 Like / DDS but: with three-step vacuum control (-25 kpa, -55kPa, -75 kpa), with graduated secretion container 1 l, PSU, without vacuum precision indication, without condensate trap, without sliding cover. / R 313.0301.0 Like ATMOS A 261 / DDS, but with Receptal container, support and / M 313.0302.0 Like ATMOS A 261 / DDS, but with Medi-Vac container, support and 266 Please contact us via: Care@atmosmed.de. Phone: +49 7653 689-374. Fax: +49 7653 68986-374
Basic device l Basic device l Versions Mains-operated devices ATMOS C 161 Aspirator / DDS l User-friendly l Triple overflow protection due to: - innovative filter technology - integrated overflow protection - Direct-Docking- System (DDS) l Infinitely variable vacuum adjustment and precision indication l Condensate trap for quick visual inspection whether device is oversucked l Secretion container autoclavable up to 1000 x l Sliding cover for protection of the control elements l For use on the ward, for nursing care and during rehabilitation Safe secretion management for the respiratory tract suction with low follow-up costs! / DDS 313.0000.0 Portable secretion suction device, air-flow rate of pump: 16 ± 2 l/min, Vacuum: -80 kpa ± 2 kpa / -800 mbar ± 20 mbar / -600 mmhg ± 15 mmhg, infinitely variable vacuum adjustment and precision indication, graduated secretion container 1 l, secretion container lid with triple oversuction safety by modern filter technology, integrated oversuction protection and DDS, 1 DDS bacterial filter, condensate trap, silicone suction hose Ø 6 mm, L = 1,30 m, fingertip, all hoses and parts of the secretion container are sterilisable up to 134 C, 2 m mains cable for 230 V~/50/60 Hz, / R 313.0001.0 Like / DDS, but with Receptal -container, support and / M 313.0002.0 Like / DDS, but with Medi-Vac container, support and REF We have been certified acc. to EN ISO 9001 and EN ISO 13485 / DDS 313.0200.0 Like / DDS but: with three-step vacuum control (-25 kpa, -55kPa, -75 kpa), with graduated secretion container 1 l, PSU, without vacuum precision indication, without condensate trap, without sliding cover / R 313.0201.0 Like / DDS, but with Receptal container, support and / M 313.0202.0 Like / DDS, but with Medi-Vac container, support and Please contact us via: Care@atmosmed.de. Phone: +49 7653 689-374. Fax: +49 7653 68986-374 C a r e 267
MedizinTechnik Accessories and consumables for ATMOS C 261 / A 261 Aspirator, and ATMOS C 161 / A 161 Aspirator l Accessories l Consumables l Technical data REF Accessories for, and, Grad. secretion container 1 l, PPSU, (ATMOS C-class Asp.) 313.0005.0 Grad. secretion container 1 l, PSU, (ATMOS A-class Asp.) 313.0015.0 Lid for secretion container (incl. 1 spare DDS filter) 313.0006.0 Hose connector 000.0836.0 Hose rewind for suction hoses 313.0007.0 Separate rinsing container set (incl. lid and support) 313.0008.0 Receptal -external container 1 l 312.0464.0 Support for Receptal -external container 1 l 313.0009.0 Medi-Vac -external container 1 l 312.0473.0 Support for Medi-Vac -external container 1 l 313.0010.0 Carrying bag with practical storage pockets for consumables Device support with rotatable holder for attaching the unit to patient s bed, to a stand, wheelchair or standard rail etc. 313.0011.0 313.0012.0 Basket for catheters, L = 340 mm 444.0140.0 Basket with standard rail holder 320.0075.0 Power cable, 3-wire 008.0866.0 Trolley on 4 castors, self-assembly 320.0070.2 Consumables for ATMOS C 261 / A 261 Aspirator, ATMOS C 161 / A 161 Aspirator DDS bacterial filter / oversuction protection, 10 pcs, 50 pcs, 100 pcs, hydrophobic, disposable, not autoclavable Exchange: 1 x per patient, with same patient every 10 days Suction hose, silicone, Ø 6 mm, L = 1,30 m, (134 C); Exchange: after 20 x autoclaving, every 4 weeks Suction hose, disposable, Ø 6 mm, L = 1,30 with integrated funnel and fingertip, sterile, not autoclavable, 10 pcs; Exchange: 1 x per patient Fingertip, sterile, not autoclavable, price for 10 pcs; Exchange: 1 x per patient, with same patient every 2-3 days Fingertip, sterile, not autoclavable, price for 100 pcs; Exchange: 1 x per patient, with same patient every 2-3 days Suction catheter Unomedical, size: CH 12, sterile, not autoclavable, 100 pcs (white, Ø 4 mm) straight, central opening, 2 small lateral openings, L = 50 cm, suction connection Ø 6 mm Suction catheter Unomedical, size: CH 14, sterile, not autoclavable, 100 pcs (green, Ø 4,7 mm) like CH 12 Suction catheter Unomedical, size: CH 16, sterile, not autoclavable, 100 pcs, (orange, Ø 5,3 mm) like CH 12 Receptal -bag 1 l, 50 pcs; not autoclavable; Exchange: 1 x per patient Medi-Vac -internal container 1 l, not autoclavable, 50 pcs; Exchange: 1 x per patient Plak-Vac TM toothbrush with suction mechanism not autoclavable, exchange: 1 x per patient, with same patient every 4 weeks, minimum order quantity 5 pcs. (for further information regarding this product see page 277) 340.0054.0 000.0013.0 006.0057.0 * 000.0347.0 * 000.0347.1 * 000.0294.0 * 000.0295.0 * 000.0296.0 * 312.0463.0 * 312.0474.0 * 000.0821.0 268 Please contact us via: Care@atmosmed.de. Phone: +49 7653 689-374. Fax: +49 7653 68986-374
Technical Data Mains-operated devices We have been certified acc. to EN ISO 9001 and EN ISO 13485 0124 Technical Data Airflow rate of pump: 26 ± 2 l/min Max. vacuum at sea level -78 kpa* ± 2 kpa / -780 mbar ± 20 mbar / -585 mmhg ± 15 mmhg Power consumption: ca. 105 VA (230 V~) ca. 72 VA (100 V~) ca. 86 VA (115 V~) ca. 105 VA (127 V~) 230 V~ (+/-10 %) 50/60 Hz; Special voltage: 100/115/127 V~ (+/-10 %) 50/60 Hz Sound level: 50,0 db (A) @ 1 m (nach ISO 7779) Technical Data Airflow rate of pump: 26 ± 2 l/min Max. vacuum at sea level: -78 kpa* ± 2 kpa / -780mbar ± 20 mbar / -585 mmhg ± 15 mmhg Three-step vacuum control: low: - 25 kpa; medium: - 55 kpa; high: - 75 kpa (depending on actual air pressure / ambient conditions) Power consumption: ca. 105 VA (230 V~) ca. 72 VA (100 V~) ca. 86 VA (115 V~) ca. 86 VA (127 V~) 230 V~ (+/-10 %) 50/60 Hz; special voltage: 100/115/127 V~ (+/-10 %) 50/60 Hz Sound level: ca. 53,0 db (A) @ 1 m (nach ISO 7779) Technical Data Airflow rate of pump: 16 ± 2 l/min Max. vacuum at sea level: -80 kpa ± 2 kpa / -800 mbar ± 20 mbar / -600 mmhg ± 15 mmhg Power consumption: ca. 170 VA (230 V~) ca. 200 VA (100 V~) ca. 275 VA (115 V~) ca. 200 VA (127 V~) 230 V~ (+/-10 %) 50/60 Hz; special voltage: 100/115/127 V~ (+/-10 %) 50/60 Hz Sound level: 50,0 db (A) @ 1 m (acc. to ISO 7779) Classifications for all the devices listed here: protection category: IPX0; degree of protection: type BF; protection class: II; class: IIa (acc. to appendix IX, directive 93/42/EEC) Technical Data Airflow rate of pump: 16 ± 2 l/min Max. vacuum at sea level: -80 kpa ± 2 kpa / -800 mbar ± 20 mbar / -600 mmhg ± 15 mmhg Three-step vacuum control: low: - 25 kpa; medium: - 55 kpa; high: - 75 kpa (depending on actual air pressure / ambient conditions) Power consumption: ca. 170 VA (230 V~) ca. 200 VA (100 V~) ca. 275 VA (115 V~) ca. 200 VA (127 V~) 230 V~ (+/-10 %) 50/60 Hz; special voltage: 100/115/127 V~ (+/-10 %) 50/60 Hz Sound level: ca. 53,0 db (A) @ 1 m (acc. to ISO 7779) These technical data are valid at the moment of printing, and are subject to technical change without notice! Please contact us via: Care@atmosmed.de. Phone: +49 7653 689-374. Fax: +49 7653 68986-374 C a r e 269
MedizinTechnik At a glance: Capability characteristics of the new battery-operated ATMOS respiratory tract suction devices Battery-operated devices ATMOS C 161 Battery ATMOS A 161 Battery Atmoport N REF 313.0400.0 REF 313.0500.0 REF 312.0400.0 Suction performance 22 l/min 22 l/min 36 l/min Vacuum adjustment infinitely variable three-step-control* infinitely variable Vacuum display Vacuum gauge - Battery level indication 5-step-LED 5-step-LED 4-(5)-step-LED Power supply Mains operation 100-240 V~ 50/60 Hz 100-240 V~ 50/60 Hz 100-240 V~ 50/60 Hz Battery operation 12 V DC 12 V DC 12 V DC Operating time a) Mains operation by mains connection (with power pack charger REF 312.0439.0) 40 min 40 min ca. 60 min b) Battery operation 40 min 40 min 45 min Charging time (at complete discharge) 1,75 h 2,5 h 2 h Sliding cover Blue cover to protect the control elements - - Condensate trap Quick visual inspection whether device is contaminated - - Secretion container Material PPSU PSU PP autoclavable ca. 1000 x ca. 100 x ca. 30 x Catalogue page 272 272 274 *Three-step control: low: -25kPa medium: -55 kpa high: -75kPa (depending on actual air pressure and ambient conditions) 270 Please contact us via: Care@atmosmed.de. Phone: +49 7653 689-374. Fax: +49 7653 68986-374