OPERATING INSTRUCTIONS with safety features

Similar documents
Wood logs boiler with a gasication eect IGNIS KW. INSTRUCTIONS MANUAL for usage and maintenance

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance

MANUAL. Page 1/44

INSTALLATION AND OPERATION MANUAL

Boiler Technical Specifications (2013)

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

Manual and installation instructions. Function. Operating phase

WHE 2.24 / WHE 2.24 FF

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE OF AN AUTOMATED PELLET BURNER FROM SERIES GP XX SC.

USER MANUAL 9kW LILLY PELLET STOVE

Instruction manual. GP45 cs. for installation and operation of Automatic pellet burner. p. 1/56

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

Biomass. Biomass solid fuel boiler range

Instruction manual for installation and operation of automatic pellet burner of series GP IV

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

Instruction manual for installation, operation and maintenance of automatic pellet burner of series GP on solid fuel hot water boiler VIADRUS U26

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

ISO 9001 TUV CERT CE

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

PELLET BURNER PV 350

INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

INSTALLATION AND OPERATING INSTRUCTIONS

Importance of a Draught Regulator

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

- 12, , TECHNICAL INSTRUCTIONS

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

BIX B-One 100 kw INSTALLATION GUIDE

AIEA Presentation. Wood pellets heating systems.

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 200

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

Installation and operation manual for pellet boiler TANGRA HP 30. Manufactured in accordance with standard: - EN Rev.

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL MANUAL. CENTROMETAL d.o.o. Glavna Macinec Croatia tel: ; fax :

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

USER MANUAL FOR SOLID FUEL STOVE VOLCANO - 24kW

DEVRON SERIES MULTI FUEL FIRED GASIFICATION HOT WATER BOILERS DEVRON-30, DEVRON-40 OPERATION, USE AND MAINTENANCE MANUAL

Heating with log wood

INSTRUCTION MANUAL. for installation and operation of solid fuel cookers. Victoria and Victoria Lux

TECHNICAL AND OPERATIONAL DOCUMENTATION

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Installation & Manual. Model T-25

ecomax 200 W Boiler regulator FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE:

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE OF PELLET BOILER OF SERIES BISOLID

Rozp.UE2015/ kw kw

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Combined boiler. for solid fuel and pellets

Electronic Pellet Burner Controller NPBC-V3M

PER-EKO type KSW & KSW PLUS Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE. ARITERM SWEDEN AB Installation, Operation & Maintenance /28

NEW LINE BOILER CONTROLLERS

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

PELLET BOILER BIODOM 33. Instructions for use, maintenance and installation

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW. Pellet Boilers. Future of Ecological Heating

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic

User & Installation instruction

W W W. A T T A C K. S K

Eco Angus Wood Pellet Boilers

REV.01 /

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Operating Instructions

PELLETS BURNER 15-60kW MOC

Product catalogue Pleszew, 2015

SERVICE AND INSTALLATION MANUAL FOR CENTRAL HEATING BOILER BENEKOV R100

WOOD CHIP HEATING HPK-RA

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Cm Pelet-set (60-90 kw)

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

BIO-CK P Unit TECHNICAL INSTRUCTIONS. for installation, use and maintenance of hot water boiler and installation of additional equipment

WOOD CHIP HEATING HPK-RA

ENERGY TOP. Condensing boiler solutions

MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40

Smart Fire. pellets burning automatic boiler. Operation manual

USERS MANUAL FOR GAS BOILERS

it warms us up! PRICE LIST

Separate food waste from other plastics/metals-> new material! Best suited for recycling! Crush & separate. PET bottles Cans Vinyl sheets

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER WITH RELAY CONTROL

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER/MODULE WITH THREE STAGE CONTROL

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Pellet burner PV 180a. User manual

THE WOOD GASIFYING BOILER ATTACK SLX, DPX, DP STANDARD / PROFI / LAMBDA TOUCH / COMBI PELLET

CITY OPEN - CITY BOX from 25 to 35 kw

Eligibility criteria

Forced draught gas burner

Heating with wood chips

Transcription:

Solid fuel boiler TKK3 with wood pellet burner TERMEC 70-90 KW OPERATING INSTRUCTIONS with safety features Prhova ka bb 22310 imanovci, Srbija Tel/Fax. +381 22 480404 +381 63 259422 oce@termomont.rs www.termomont.rs June 3, 2011

Contents 1 Konstrukcija i karakteristike kotla 2 1.1 Dimenzije............................................. 3 1.2 Technical data chart EN 303-5................................. 3 1.3 On Product............................................ 3 2 How It Works 3 3 Recommendations for boiler shipment and storage 5 3.1 Delivery form........................................... 5 3.2 What's in the box........................................ 5 4 Boiler installation 5 4.1 Boiler placement......................................... 5 4.2 Chimney.............................................. 5 5 Connecting the boiler with a central heating system 7 5.1 Closed system........................................... 7 5.2 Closed system combined heating with solar panels...................... 9 5.3 Open system........................................... 10 6 Boiler in function 11 6.1 First operation.......................................... 11 6.2 Burner in operation........................................ 11 6.3 Maintenance and cleaning.................................... 13 7 Safety features 13 7.1 Thermal safety in case of overheat (closed systems)...................... 13 A Declaration Of Conformity 15 1

1 Konstrukcija i karakteristike kotla Parts of the boiler: 1. Combustion chamber 2. Grid 3. Boiler 4. Grid cleaning 5. Return 6. Safety ow pipe 7. Base 8. Primary air ap 9.01 Burner tube 9.02 Internal screw 9.03 Control board 9.04 Fan 10 Opening for burner 11. Lower door 12. Upper door 13. 2nd / 3rd passage ap 14. Insulation 15. Boiler housing 16. Flow 17. Flue 18. Opening for cleaning 19. Grid cleaning handle 20. Pellet tank 2

1.1 Dimenzije Type TKK3 Weight (kg) Weight w/ tank B without tank (mm) B with tank (mm) L without tank (mm) L with tank (mm) H (mm) A (mm) 70 395 506 730 1450 1270 1525 1300 990 180 5/4 90 510 621 750 1470 1270 1525 1300 990 220 5/4 1.2 Technical data chart EN 303-5 1.3 On Product Nominal power TKK3 PELLET (KW) 70 90 Power range (KW) 70-90 90-100 Necessary draught (mbar) 0,27 0,28 Water content (l) 155 178 Output gas temperature at nominal power ( C) 150 150 Chamber Volume (dm 3 ) 0.2 0.23 Mass ow at nominal power (kg/s) 0,08 0,1 Network (V/Hz) 230/50 230/50 IP protection level 30 30 Fuel consumption (kg/h) 13 15 Temp. regulation range (solid fuel) ( C) 60-90 60-90 Minimum temp. return line (solid fuel) ( C) 60 60 Eciency 90% 90% Boiler class 1 1 E (Φ) F (inch) Prescribed fuel declaration for this boiler is wood pellet only with caloric value > 17.5 MJ/kg, diameter 6 mm, length 35 mm, maximum moisture content 8%; Three-pass solid fuel boiler TKK3 PELLET is fully compatible with TERMEC burner for wood pellet combustion (eciency level 91%) and it fullls the requirements of the European norm EN 303/5. Following the norm demands, wall thickness of boiler plates in contact with water is 5 mm. Boiler comes together with stock for pellets with capacity for round 200 kg of pellets, which can be freely positioned near the boiler. Boiler is equipped with a thermometer, removable ash-tray and cleaning kit and also with a thermostat to prevent condensation (caused by low temperature of the return pipe). Upper door of the boiler is covered by re-proof glass with a small opening for secondary air. Pressure test is done at 6 bar pressure. Working pressure is 2.5 bar The burner warranty is 2 years, while the warranty against leakage is 5 years (if following the guidelines given in the operation manual). 2 How It Works Wood pellet burner TERMEC is an integral part of the TKU3 PELLET set and is designated for optimum and complete combustion of wood pellets. The burner itself consists of burner body and feeding auger which connects the pellet storage with the burner body. Burner body is to be mounted on the lower door of the boiler with a help of a specially designed ange adapter (part of the set). Burner function is fully automatic and it can be programmed seven days a week. Automatic control algorithm is based on two input parameters: Water temperature inside the boiler and ue gas temperature. 3

Unlike other similar products available on the market, TERMEC has an additional screw-transporter inside the burner body which mechanically feeds the pellets into the ame tube, where pellets are blown into the boiler chamber by a fan. The additional transporter is an essential safety feature which protects burner from eventual reverse ame from the boiler. Secondary screw is synchronized with the outter feeding auger - with every cycle of the external motor the inner motor will turn as well; only delayed for several seconds. The ame tube is made of stainless steel (wall thickness 5 mm), it is resistant against deformation at high temperature. Inside the ame tube there is a multi-functional piece called the burner grid or ash-tray (not to be confused with a boiler ash-tray). It is also made of high resistance stainless steel and its main feature is to prevent sedimentation of non-combustible particles. The piece has such a form to redirect the air stream of the fan from lower side in order to blow out the particles toward the heating chamber of the boiler. If however, the low quality pellet is used, which is not pure wood but contains inorganic particles such as soil or sand, the formation of silicate layers is inevitable. This formation can be removed only by frequent cleaning of the tray and on the other hand it will cause the corrosion of the material and negatively aect the combustion process. For that reason we strongly recommend to use high quality CERTIFIED wood pellets with our pellet set. No warranty is taken if the pellet does not fulll the following requirements: caloric value > 17.5 MJ/kg, pellet diameter 6 mm, average length 35 mm, maximum moisture content 8%. Combustion process can be divided in 5 phases: ignition, ame stabilization, main working cycle, modulation and turning o. When burner has reached desired temperature set by user, it will continue working in the modulation cycle - which means minimum power consumption. TERMEC burner has a transformer and its motors and electronic parts use 24 V direct current. Stable operation, lower power consumption and a lower risk against potential damage come as a result. In case of a black-out, the burner will stop itself and than continue according to the program before the interruption occured. For detailled explanation on burner function please refer to burner manual. The user can always switch to the conventional wood or coal fuel. Before that, pellet burner must be removed from the boiler and the burner opening must be closed with a cap (part of the set). It is necessary to obtain and mount a draught regulator in order to operate the boiler in this case (not included in the set). It is not possible to re woodlogs and pellet at the same time. 4

3 Recommendations for boiler shipment and storage 3.1 Delivery form The boiler comes in three parts, boiler chamber, pellet storage and the boiler housing packed separately. Chamber is wrapped with plastic sheet, and upper door containing reproof glass should have a small styrofoam protection sheet. The whole set is transported on wood pallet. The boiler must always stand in its vertical position. The rotation of the boiler during the shipment or installation represents a serious risk and can lead to damaging the boiler. It is forbidden to stack boilers vertically one onto other. The boiler can be stored only in closed rooms with no atmospheric inuence. The humidity in the storing room also must not exceed the critical value of 80%, so as not to create any condensate. The temperature of the storing room must be in the range of +/- 40 C. 3.2 What's in the box The following parts are supplied together with the boiler: Wood pellet burner TERMEC with feeding auger, regulation panel and connecting tube Special ange to mount burner body on boiler lower door opening Cap to close boiler opening in case of using conventional solid fuel Two pieces of boiler ash-tray Cleaning kit Warranty note for both boiler and burner (separately) 4 Boiler installation 4.1 Boiler placement The boiler room should have air-conditioning. The boiler should be mounted in the boiler room permiting access to all its parts as shown below: 4.2 Chimney Boiler connection to the chimney is shown in the gure: 5

Proper dimensioning of the chimney is a very important premise for optimum boiler performance. The purpose of the chimney is to take out the products of combustion but also to secure necessary air draught in the boiler. The graph shows how to chose the necessary height for the chimney as a function of chimney opening. Proper chimney insulation is very important and should be at least 50 mm thick. Depending on the necessary draught of the boiler, the cross section and the height of the chimney are determined. Please advise technical material given by chimney producer. Minimum chimney height for wood boilers is 6 m. Round chimney made of stainless steel modules is recommended in order to keep the condensation inuence low. 6

5 Connecting the boiler with a central heating system 5.1 Closed system The following schemes show how to connect the boiler to the central heating installation with or without a heat accumulator tank: System parts: 1. Boiler 2. Heat accumulator 3. Heat exchanger 4. Non-return valve 5. Mixing valve 6. Pump of the radiator heating 7. Automatic regulation for the radiator heating 8. Expansion vessel 9. Exchanger pump 10.Valve 11.Thermo-manometer 12. Safety valve 13. Four-arm mixing valve 14. Dirt remover 15. Safety valve 7

Schemes for connecting both radiators and oor heating: System parts: 1. Boiler 2. Heat accumulator 3. Heat exchanger 4. Non-return valve 5. Distributor 6. Mixing valve 7. Pump of the radiator heating 8. Pump of the oor heating 9. Regulator of the automatic regulation for the radiator heating 10. Regulator of the automatic regulation for the oor heating 11. Receiver 12. Expansion tank 13. Exchanger pump 14.Valve 15.Thermo-manometer 16. Filth catcher 17. Four-arm 8

mixing valve 18. Safety valve It is not necessary to install the heat accumulator. However, it is recommended.for 1 KW power of the boiler, a capacity of the heat accumulator of 25-50 l is recommended. One must also bear in mind that the power of the boiler must be enough in order to both warm up the water in the accumulator, as well as to provide direct feed to the installation in very cold periods the chosen power of the boiler should be 1.5 higher than the power of an oil-gas boiler for the given squaring. It is recommended that the closed central heating system is supplied with an expansion tank, the capacity of which must amount to at least one tenth of the total capacity of the system (including the water volume in the boiler). The system must also have an automatic aeration valve with the help of which air will be eliminated from the system. The use of a safety valve is obligatory (with a 2-3 bar threshold, depending on the power of the boiler) and it must be mounted near the boiler. It is also necessary that the system has a thermometer and manometer in order to read the temperature and pressure in the system. In case of using conventional solid fuel, the temperature of the return line should not fall below 60 C, so as to avoid leaking, i.e. condensation in the boiler, which can further lead to corrosion. The temperature of the starting line should not fall below 70 C. It is recommended to use a four-arm mixing valve on the return line of the boiler or a regulation group such as LADDOMAT 21. It is also recommended to mount a lth catcher on the return line. Qualied installer should be entrusted with the mounting of the heating and the initial operation. This must be a person who will take over the responsibility and guarantee the correct operation of the boiler and of the complete central heating system. In the case of an incorrectly planned system with manifesting deciencies caused by the respective person's incorrect installation of the system, which can again lead to an incorrect operation of the boiler, the complete liability for the material damage and potential new costs arising in relation to it is borne exclusively by the person who was entrusted with the mounting of the central heating system, and not by the boiler manufacturer, sales representative or seller. 5.2 Closed system combined heating with solar panels The following scheme depicts a heating system connected over a hybrid solar boiler within an accumalation tank: Termomont in its oer of solar boilers also has a 'hybrid' version of a heat accumulation tank and stainless steel solar boiler in one: ATS combined tank. When boiler heats up the 'technical' water inside 9

the boiler - as do the solar panels through the spirale. The drinking water is inside the inner vessel which is heaten indirectly by the technical water. 5.3 Open system The following scheme shows how to connect the boiler to the open central heating system: 10

System parts 1. Boiler TKU3 PELLET 2. Valve 3. Thermo-manometar 4. Boiler circle pump 5. Three-way mixing valve or LADDOMAT 21 6. Heat accumulator tank 7. Three-way mixing valve 8. Automatic three-way mixing valve 9. Circulation pump for radiator heating 10. Open expansion vessel 11. Automatic regulation MRTR Plus (First) 12. Heating circle 13. Sanitary water circulation pump 14. Sanitary water accumulation tank SOLAR I 6 Boiler in function 6.1 First operation When putting the boiler and burner in operation for the rst time (this job can be performed by authorized and qualied person only) it is necessary to check if the factory settings are 6.2 Burner in operation To turn the burner on perform the following steps: 1. Turn the main switch for power supply. 2. By pressing the manual feed button, it is necessary to ll the feeding auger with pellets and the burner itself. Before that make sure that there are enough pellets in the pellet storage and if not please rell it. 3. The burner is tuned on/o by pressing the corresponding button. When all the parameters are set at the time of the initial burner operation, this is all the end-user has to do. Burner operation can be divided into several zones: 11

1. Start-up / Ignition. Burner is put into operation by pressing the corresponding button. Ignition process is controlled automatically by the preprogrammed parameters. When the burner is turned on, the electrical heater starts to heat up pellets (for 4 minutes by default setting) and after that the fan starts to blow. Ignition process lasts until the ue gas temperature reaches 70 C. The burner goes into another phase ("stabilization"). If for some reason, after 15 minutes the 70 C temperature is not reached, the burner will be turned o and the message on the display will tell that the burner ignition did not succeed. 2. Flue gas stabilization. After the ignition process is successfully completed, it is necessary to allow burner some time to stabilize the ame. This period is according to default setting one minute long. After that, the burner is ready to start the feeding process according to adjusted power range and start increasing the water temperature toward the desired one. 3. (Main) working cycle. The burner remains in this state until one of the following conditions is completed: water temperature inside the boiler has reached the set value ue gas temperature has reached 250 C; if one of the conditions is fullled the burner will enter the "modulation" cycle. 4. Modulation. Modulation means the burner operates with minimum power necessary only to retain not to increase the (reached) water temperature. According to factory presets modulation range is set between 2 C below the desired temperature (the lower threshold) and 5 C above the desired temperature (the upper threshold). For instance, if the desired temperature is set at 50 C, between 48 C and 55 C burner will feed minimum amount of pellets. If the temperature exceeds the upper threshold burner will turn o. If it goes below the lower threshold, burner will be in main working cycle (again). 5. Turning o. When the burner is turned o by pressing the button, no pellets are fed to the burner and the fan starts to blow out the remaining pellets through the ame tube until the ue gas temperature is below 60 C. Burner display should indicate the current working zone of the burner. For the cleaning purpose, fan blows out the particles in the ame tube every 60 minutes (by default) and this operation takes 30 seconds. If there is an electricity black-out, and there is no alternative power supply, the burner will be extinguished and after the black-out is over, it will continue its operation automatically. The power consumption of the burner is in the range of a light bulb, except when ignition takes place - then it can reach up to 300W. The ignition itself cannot take longer than 15 minutes. All technical parameters and values mentioned above are preset by the factory, but the authorized person can change them on the spot. Important notes: 1. To turn on/o hold the corresponding button for 3 seconds. 2. Main switch should be always turned on - during the heating season. 3. Manual feed button is situated on the side of the burner and it is important that burner is lled with pellets before start. 12

6.3 Maintenance and cleaning Using wood pellets as a primary fuel means very low level of ashes (less than 1%). The cleaning of the boiler can thus be performed once per week and does not take more than 5 minutes. Burner ash-tray should be however cleaned every day or two - operation which takes less than a minute. Using pellets means also low temperature of the ue gases due to the high eciency of combustion. This means the boiler would last much longer compared to combustion with traditional solid fuels such as wood or coal. 7 Safety features 7.1 Thermal safety in case of overheat (closed systems) Burner has two main safety features: The internal feeeding auger prevents re passing from the boiler to the burner body. The other feature is that if the temperature of the ue gases does not drop below 250 C the burner will be forced to work with minimum power (which means minimum quantity of pellets added every time). For additional hydraulic protection in the closed systems it is necessary to install to safety thermal valve shown on image (to be bought separately, not an integral part of the boiler). If for some reason the temperature of the water inside the boiler should exceed 95 C this valve would release the water from the water supply system to cool down the water temperature inside the boiler. 13

Connection scheme for the thermal safety valve: 1. Cold water entering from the water supply system 2. Cold water entry into boiler 3. Hot water going outside the boiler 4. hot water ending in the sewage water system 5. Thermo-valve sensor To connect the safety valve: Connect the sensor of the valve (outter thread 1/2") at depicted place on the boiler, position 5 (inner thread 1/2") Connect the cold water entry (on valve's input is marked with C) than connect the exit line (valve marked with: ) with the corresponding exit line on the boiler (position 21) Connect position 21 (on the boiler) with the input line on the valve (valve is marked with: ) Connect the valve (marked with S) to the sewage system. 14

A Declaration Of Conformity We, Termomont d.o.o. with legal seat on the address Prhova ka street bb, 22310 imanovci, Republic of Serbia, under sole responsibility declare that: Wood pellet boilers TKK3 PELLET 70, TKK3 PELLET 90 produced 2010. and 2011. as by its construction, design and performances are in accordance with the following norms and directives prescripted by the European Union: 97/23 EEC Pressure device directive EN 303/5 Norm for solid fuel boilers" imanovci, June 3, 2011 Signature of the responsible person.................................... 15